Академический Документы
Профессиональный Документы
Культура Документы
B3656M/L R1
PAGE 2
Goulds Water Technology
Commercial Water
FEET
PIES
500
3500 RPM
400
21/2 x 3 — 10
TOTAL DYNAMIC HEAD (CARGA DIN MICA TOTAL)
300
11/2 x 2 — 10
2 1 /2 x 3 — 8
200
21/2 x 3 — 9
3x4—8 3 x 4 — 10
4x5—8
100
0
0 200 400 600 800 1000 1200 1400 1600 1800
GALLONS PER MINUTE (GALONES POR MINUTO) U.S. GPM
FEET
PIES
300
1750 RPM
4 x 6 — 16
250
200
TOTAL DYNAMIC HEAD (CARGA DIN MICA TOTAL)
150
21/2 x 3 — 13
6 x 8 — 13
100 2 1/2
x3 3 x 4 — 13
— 4 x 6 — 13 8 x 10 — 13
10
11/2 x 2 — 10 2 1/
2
x3
—
9
4 x 6 — 10
50
2 1 /2 x 3 — 8
3 x 4 — 10
3x4—8 4x5—8
0
10 100 200 400 1000 1500 2000 3000 4000 5000
GALLONS PER MINUTE (GALONES POR MINUTO) U.S. GPM
PAGE 3
Goulds Water Technology
Commercial Water
Model 8AI/BF / Size (Tamaño) 11/2 x 2 – 10 NOTE: Not recommended for operation beyond Optional Impeller
printed H-Q curve.
RPM 3550 Curve (Curva) CN0207R01 NOTA: No se recomienda para funcionamiento superior
Impulsor optativo
METERS FEET
METROS PIES IMP. DWG. No. 114-51 al impreso en la curva H-Q. Ordering Code Dia.
Código de pedido Diá.
160
500 50 % EFF A 101⁄16"
A
8' 54 12' NPSHR – FEET (PIES) B 93⁄16"
10'
140
58 14' 16' C 83⁄8
B 60 D 7¾
400
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
120 58
E 7¼
54
C F 7
100
300
NOTE: Pump will pass a
D
sphere to 5⁄32" diameter.
40 HP
80 E NOTA: La bomba dejará
F
30 HP pasar una esfera de hasta 5⁄32
200
de pulgada de diámetro.
60
25 HP
20 HP
40
15 HP
100
20
0 0
0 50 100 150 200 250 U.S. GPM 300
0 10 20 30 40 50 60 m3∨hr
CAPACITY (CAPACIDAD)
Model 7AI/BF / Size (Tamaño) 21/2 x 3 – 8 NOTE: Not recommended for operation beyond printed H-Q curve. Optional Impeller
RPM 3500 Curve (Curva) CN208R00 NOTA: No se recomienda para funcionamiento superior al impreso Impulsor optativo
en la curva H-Q.
IMP. DWG. No. 114-50 Ordering Code Dia.
Código de pedido Diá.
METERS FEET
METROS PIES 6' NPSHR – FEET (PIES) 8' A 715⁄16"
7' B 77⁄16
73
300 40% EFF 50 60 10'
65 70 C 73⁄16
A 75 12'
80 78
D 613⁄16
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
250
15' 18' E 63⁄8
B 78
75 F 63⁄16
73
C
NOTE: Pump will pass a
60 200 D sphere to 5⁄16" diameter.
70
NOTA: La bomba dejará
E
F 25 HP pasar una esfera de
hasta 5⁄16 de pulgada de
150 65 diámetro.
40
20 HP
60
100
15 HP
20
50
0 0
0 50 100 150 200 250 300 350 400 U.S. GPM
0 20 40 60 80 100 m3∨hr
CAPACITY (CAPACIDAD)
PAGE 6
Goulds Water Technology
Commercial Water
Model 21BF / Size (Tamaño) 21∨2 x 3 – 9 NOTE: Not recommended for operation beyond Optional Impeller
RPM 3550 Curve (Curva) CN0672R00 printed H-Q curve. Impulsor optativo
METERS FEET NOTA: No se recomienda para funcionamiento
METROS PIES IMP. DWG. No. 279-15 superior al impreso en la curva H-Q. Ordering Code Dia.
Código de pedido Diá.
450
A A 101⁄16"
B 60 % EFF
125 B 97⁄8
400 8' NPSHR – FEET (PIES)
C 65 10' C 9½
D 68 14' D 9¼
350 16'
E
E 815
⁄16
100 70
20' 24'
F 8½
F
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
300 65 G 83⁄16
G
H 60 H 8
75 250 J 56
J 711⁄16
NOTE: Pump will pass a
200 sphere to 5⁄16" diameter.
NOTA: La bomba dejará
50 pasar una esfera de
60 HP
150 hasta 5⁄16 de pulgada de
50 HP
diámetro.
20 HP 40 HP
100
30 HP
25 25 HP
50
0 0
0 100 200 300 400 500 600 700 U.S. GPM 800
Model 11AI/BF / Size (Tamaño) 21∨2 x 3 – 10 NOTE: Not recommended for operation beyond Optional Impeller
RPM 3550 Curve (Curva) CN0085R01 printed H-Q curve. Impulsor optativo
NOTA: No se recomienda para funcionamiento superior
IMP. DWG. No. 121-37 al impreso en la curva H-Q. Ordering Code Dia.
METERS FEET Código de pedido Diá.
METROS PIES
10' NPSHR – FEET (PIES) A 101⁄16"
12' 14' B 97⁄8
16'
150 500 64 % EFF
72 18' C 95⁄8
A 70 74 20' D 9
B
76 22'
C
E 85⁄8
125 76
400 F 8¼
74
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
D
72
G 8
E
H 75⁄8
100 F
G
J 71⁄8
300 75 HP
H NOTE: Pump will pass a
75 J
sphere to 5⁄16" diameter.
60 HP
NOTA: La bomba dejará
200 50 HP pasar una esfera de
50 40 HP hasta 5⁄16 de pulgada de
diámetro.
30 HP
100
25
0 0
0 100 200 300 400 500 600 700 U.S. GPM 800
PAGE 7
Goulds Water Technology
Commercial Water
Model 16AI/BF / Size (Tamaño) 3 x 4 – 8 NOTE: Not recommended for operation beyond printed Optional Impeller
H-Q curve. Impulsor optativo
RPM 3500 Curve (Curva) CN374R00 NOTA: No se recomienda para funcionamiento superior al impreso
METERS FEET
METROS PIES IMP. DWG. No. 277-09 en la curva H-Q. Ordering Code Dia.
Código de pedido Diá.
90 300 45% EFF 58 68 11' 13'
73
A 76 A 81⁄16"
B 77⁄16
80
250 D 6¾
16' 21' NPSHR – FEET (PIES)
76 E 63⁄8
70 B
F 515⁄16
73
27' G 5½
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
60 200 68
D
H 51⁄8
J 45⁄8
E 58
50
NOTE: Pump will pass a
150
F sphere to 3⁄8" diameter.
40 NOTA: La bomba dejará pasar
G una esfera de hasta 3⁄8 de pul-
50
H gada de diámetro.
100
HP
30
40
HP
J 30
20 HP
25
50 20 HP
HP
10 15
10 HP
7 1∨ HP
2
HP
0 0
0 100 200 300 400 500 600 700 800 U.S. GPM 900
Model 3656/3756 M-Group 3500 RPM NOTE: Not recommended for operation beyond Optional Impeller
printed H-Q curve. Impulsor optativo
METERS FEET 12BF / Size (Tamaño) 3 x 4 – 10 NOTA: No se recomienda la operación más allá
Ordering Code Dia.
METROS PIES Imp. Dwg. 118-81 de la curva impresa de H-Q (carga-capacidad).
Código de pedido Diá.
400
60% EFF. 70 G 91⁄8"
10' NPSHR – FEET (PIES)
74 76
11' H 8¾
350 G 78
80 13'
J 89⁄16
100 H
15'
K 81⁄8
300 J L 7¾
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
80
K 78 M 75⁄8
76 18'
74
250 L N 7¼
M 20'
70
P 71
⁄16
N R 6¾
200 P 60
NOTE: Pump will pass a
R
50 sphere to ½" diameter.
150 NOTA: La bomba dejará
pasar una esfera de
75 HP hasta ½ de pulgada de
100 diámetro.
60 HP
50 HP
40 HP
50
30 HP
0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 U.S. GPM
0 50 100 150 200 250 300 350 m3∨hr
CAPACITY (CAPACIDAD)
PAGE 8
Goulds Water Technology
Commercial Water
Model 10AI/BF / Size (Tamaño) 4 x 5 – 8 NOTE: Not recommended for operation beyond printed Optional Impeller
H-Q curve.
RPM 3500 Curve (Curva) CN0078R00 NOTA: No se recomienda para funcionamiento superior al impreso Impulsor optativo
METERS FEET IMP. DWG. No. 120-08 en la curva H-Q. Ordering Code Dia.
METROS PIES
Código de pedido Diá.
% EFF NPSHR – FEET (PIES)
275 20'
A 77⁄8"
50 60
80 70 75
A 78 80 B 7¾
250 B 82
22' C 7½
C
70 D 7¼
225 24'
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
D
E 7
60 200 F 6¾
E 80 26'
175 F 78 G 6½
30'
50 75 H 61⁄16
G
150 70 J 5¾
H
40
125 NOTE: Pump will pass a
J 60
sphere to 5⁄16" diameter.
30 100 NOTA: La bomba dejará
75
HP pasar una esfera de
75 60 hasta 5⁄16 de pulgada de
20 50 HP
HP diámetro.
50 40
HP
10
25 30
HP
0 0
0 200 400 600 800 1000 1200 1400 1600 U.S. GPM
90 48
7'
47 F 7
25 45
80
C 42
NOTE: Pump will pass a
sphere to 5⁄32" diameter.
70 40 NOTA: La bomba dejará
20 D
pasar una esfera de
60 hasta 5⁄32 de pulgada de
35
F diámetro.
15 50
5
HP
40
10
30
20
2
5
3
HP
HP
10
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 U.S. GPM
0 5 10 15 20 25 30 35 m3∨hr
CAPACITY (CAPACIDAD)
PAGE 9
Goulds Water Technology
Commercial Water
Model 7AI/BF / Size (Tamaño) 21∨2 x 3 – 8 NOTE: Not recommended for operation beyond Optional Impeller
printed H-Q curve. Impulsor optativo
METERS FEET
RPM 1750 Curve (Curva) NOTA: No se recomienda para funcionamiento superior
METROS PIES IMP. DWG. No. 120-01 al impreso en la curva H-Q. Ordering Code Dia.
70 50% EFF 55 4' 60 NPSHR – FEET (PIES) Código de pedido Diá.
A 6'
64
20 A 7 15⁄16"
65 66 8'
B 7 7⁄16
68
60 B C 73⁄16
9'
66 D 613⁄16
55 C
F 6 3⁄16
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
64 10'
50 D
NOTE: Pump will pass a
15 11' sphere to 5⁄16" diameter.
60
45 NOTA: La bomba dejará
pasar una esfera de
55 hasta 5⁄16 de pulgada de
40 F diámetro.
50
35
10
30 5 HP
25
3 HP
20
2 HP
5
15
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 U.S. GPM
0 10 20 30 40 50 60 70 m3∨hr
CAPACITY (CAPACIDAD)
Model 21BF / Size (Tamaño) 21∨2 x 3 – 9 NOTE: Not recommended for operation beyond Optional Impeller
printed H-Q curve. Impulsor optativo
RPM 1750 Curve (Curva) CN0674R00 NOTA: No se recomienda para funcionamiento
METERS FEET
METROS PIES IMP. DWG. No. 279-15 superior al impreso en la curva H-Q. Ordering Code Dia.
120
Código de pedido Diá.
A 101⁄16"
B 97⁄8
A 64 % EFF 65
B 4' NPSHR – FEET (PIES) C 9½
100 3' 66 68
30
C 70 D 9¼
8'
D E 815
⁄16
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
5'
E 70 F 8½
80 68
66
G 83⁄16
F
G 62 H 8
20 H J 711⁄16
60 J 56
NOTE: Pump will pass a
sphere to 5⁄16" diameter.
NOTA: La bomba dejará
40 2 HP 71∨2 HP pasar una esfera de
hasta 5⁄16 de pulgada de
10
5 HP diámetro.
20
3 HP
0 0
0 50 100 150 200 250 300 350 U.S. GPM 400
0 10 20 30 40 50 60 70 80 90 m3∨hr 100
CAPACITY (CAPACIDAD)
PAGE 10
Goulds Water Technology
Commercial Water
Model 11AI/BF / Size (Tamaño) 21∨2 x 3 – 10 NOTE: Not recommended for operation beyond Optional Impeller
METERS FEET printed H-Q curve. Impulsor optativo
METROS PIES
RPM 1750 Curve (Curva) NOTA: No se recomienda para funcionamiento superior
IMP. DWG. No. 120-04 al impreso en la curva H-Q. Ordering Code Dia.
130 Código de pedido Diá.
35 62 % EFF 6' NPSHR – FEET (PIES) A 10 1⁄16"
120 A 65
70
8' C 9 5⁄8
110 72 D 9
30 C 10'
72
E 85⁄8
100
70
D G 8
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
25 90 J 7 1⁄8
E
65
80 NOTE: Pump will pass a
G
sphere to 5⁄16" diameter.
20 70 NOTA: La bomba dejará
10 HP
pasar una esfera de
60 J 7 ∨2 HP
1 hasta 5⁄16 de pulgada de
15 diámetro.
50
40
5 HP
10
3 HP
30
20
5
10
0 0
0 50 100 150 200 250 300 350 400 U.S. GPM
0 10 20 30 40 50 60 70 80 90 m3∨hr
CAPACITY (CAPACIDAD)
Model 13AI/BF / Size (Tamaño) 21∨2 x 3 – 13 NOTE: Not recommended for operation beyond printed Optional Impeller
H-Q curve. Impulsor optativo
RPM 1750 Curve (Curva) CN0104R00 NOTA: No se recomienda para funcionamiento superior al
IMP. DWG. No. 276-46 impreso en la curva H-Q. Ordering Code Dia.
METERS FEET Código de pedido Diá.
METROS PIES
A 131⁄16"
8' NPSHR – FEET (PIES)
% EFF B 12¾
50
60 200 55 C 117⁄8
A 60
63
12' D 113⁄8
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
180 B 65 E 97⁄8
50 16'
160
F 93⁄8
C
65 NOTE: Pump will pass a
140 D 20' sphere to 5⁄16" diameter.
40 63
60 NOTA: La bomba dejará
120
pasar una esfera de
E 55 hasta 5⁄16 de pulgada de
30 100 diámetro.
F 50
80
40
20
60
40
20
10
HP
15
20
10
HP
HP
0 0
0 100 200 300 400 500 600 700 800 U.S. GPM
PAGE 11
Goulds Water Technology
Commercial Water
Model 16AI/BF / Size (Tamaño) 3 x 4 – 8 NOTE: Not recommended for operation beyond printed Optional Impeller
H-Q curve.
METERS FEET RPM 1750 Curve (Curva) CN375R00 NOTA: No se recomienda para funcionamiento superior al impreso Impulsor optativo
METROS PIES IMP. DWG. No. 277-05 en la curva H-Q. Ordering Code Dia.
100 Código de pedido Diá.
30
A 8 1⁄16"
C 7 7⁄16
D 6¾
25
80 E 63⁄8
NPSHR – FEET (PIES) 4'
45% EFF 58
68 73 F 515⁄16
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
76 6'
A G 5½
20
76
H 51⁄8
8'
60 73 J 4 5⁄8
C 68
58 NOTE: Pump will pass a
15 sphere to 3⁄8" diameter.
D NOTA: La bomba dejará
40 E pasar una esfera de hasta
7
1 2
∨
3
⁄8 de pulgada de diámetro.
H
P
10 F
G
5
H HP
20
5 J
3
HP
2
HP
1H
P
0 0
0 50 100 150 200 250 300 350 400 U.S. GPM 450
0 10 20 30 40 50 60 70 80 90 m3∨hr 100
CAPACITY (CAPACIDAD)
Model 12AI/BF / Size (Tamaño) 3 x 4 – 10 NOTE: Not recommended for operation beyond printed Optional Impeller
RPM 1750 Curve (Curva) CN0096R00 H-Q curve. Impulsor optativo
NOTA: No se recomienda para funcionamiento superior al impreso
IMP. DWG. No. 120-05 en la curva H-Q. Ordering Code Dia.
METERS FEET Código de pedido Diá.
METROS PIES NPSHR – FEET (PIES)
A 10 1⁄16"
% EFF
50 60 6' 8' B 9¾
70 75 78 C 9
110 A 10'
80 12' D 85⁄8
B
30 100 E 81⁄8
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
80
F 7 5⁄8
90 78
C 75
25
15' NOTE: Pump will pass a
80 D sphere to 3⁄8" diameter.
70
NOTA: La bomba dejará
70 E pasar una esfera de
20 hasta 3⁄8 de pulgada de
60 diámetro.
60 F
50
15 50
40
10
30
15
HP
5
20
H
5
P
10
7
1 2
∨
HP
H
0 10
P
0 100 200 300 400 500 600 700 800 U.S. GPM
PAGE 12
Goulds Water Technology
Commercial Water
Model 14AI/BF / Size (Tamaño) 3 x 4 – 13 NOTE: Not recommended for operation beyond printed Optional Impeller
RPM 1750 Curve (Curva) CN0112R00 H-Q curve. Impulsor optativo
NOTA: No se recomienda para funcionamiento superior al impreso
IMP. DWG. No. 276-45 Ordering Code Dia.
METERS FEET Código de pedido Diá.
METROS PIES
A 13 1⁄16"
NPSHR – FEET (PIES) 4' C 12 5⁄16
60 200 5'
E 11¾
60 % EFF 70 G 10¾
6'
75
180 A J 91⁄ 8
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
50 78 L 8
8'
160 78
C
NOTE: Pump will pass a
75
140 E sphere to 3⁄8" diameter.
40 70 10'
12' NOTA: La bomba dejará
120 pasar una esfera de
G hasta 3⁄8 de pulgada de
60
30 100 diámetro.
50
J
80
30
20 HP
60 L
25
40 HP
10 20
HP
20 15
7 1∨ 10 HP
2
HP HP
0 0
0 100 200 300 400 500 600 700 800 U.S. GPM 900
Model 14AI/BF / Size (Tamaño) 3 x 4 – 13 NOTE: Not recommended for operation beyond printed Optional Impeller
H-Q curve. Impulsor optativo
RPM 1750 Curve (Curva) CN0118R00 NOTA: No se recomienda para funcionamiento superior al impreso
IMP. DWG. No. 276-45 en la curva H-Q.
Ordering Code Dia.
METERS FEET Código de pedido Diá.
METROS PIES
B 12 9⁄16"
D 12
60 200
F 115⁄16
4' NPSHR – FEET (PIES)
H 10 1⁄8
60% EFF 5'
180 70
K 8 11
⁄16
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
75 6'
50 B M 7 9⁄16
160 78
8' NOTE: Pump will
D 78
pass a sphere to 3⁄8"
140
40 F
75 10' diameter.
120
70 12' NOTA: La bomba dejará
pasar una esfera de
H 60 hasta 3⁄8 de pulgada de
30 100 diámetro.
50
80
K
20
60 30
M
HP
25
40 HP
10 20
HP
20 71 15
∨2 H 10
P HP HP
0 0
0 100 200 300 400 500 600 700 800 U.S. GPM 900
PAGE 13
Goulds Water Technology
Commercial Water
Model 10AI/BF / Size (Tamaño) 4 x 5 – 8 NOTE: Not recommended for operation beyond printed Optional Impeller
H-Q curve. Impulsor optativo
METERS FEET
RPM 1750 Curve (Curva) NOTA: No se recomienda para funcionamiento superior al impreso
METROS PIES IMP. DWG. No. 120-02 en la curva H-Q. Ordering Code Dia.
70 6' NPSHR – FEET (PIES)
Código de pedido Diá.
50% EFF 60 A 7 7⁄8"
20 70
75
8'
65 A 78 C 7½
80 82 D 7¼
60 C
F 6¾
G 6½
55 10'
D J 5¾
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
82
80 11'
15 50 NOTE: Pump will pass a
78 sphere to 5⁄16" diameter.
F
45 NOTA: La bomba dejará
75
pasar una esfera de
12' hasta 5⁄16 de pulgada de
70
40 G diámetro.
60
35
10
J
30
25
3
10
HP
7
1 2
∨
HP
HP
20
5
5
HP
15
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 U.S. GPM
Model 17BF / Size (Tamaño) 4 x 6 – 10 1750 RPM NOTE: Not recommended for operation beyond Optional Impeller
printed H-Q curve.
RPM 1750 Curve (Curva) CN0452R00 NOTA: No se recomienda para funcionamiento superior
Impulsor optativo
METERS FEET IMP. DWG. 277-78 al impreso en la curva H-Q. Ordering Code Dia.
METROS PIES Código de pedido Diá.
NPSHR – FEET (PIES)
35 A 101⁄16"
8'
110 60 B 99⁄16
70 75
A C 91⁄8
30 100 80 82 D 811⁄16
83
B
E 81⁄8
10'
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
90 F 7¾
83
25 C 14'
NOTE: Pump will pass a
80 82 sphere to 7⁄16" diameter.
D
80 NOTA: La bomba dejará
70 pasar una esfera de
20 E 18' hasta 7⁄16 de pulgada de
75
diámetro.
60 F
25
HP
15 50
20
HP
40
15
10
HP
10
30
HP
0 0
0 200 400 600 800 1000 1200 U.S. GPM
PAGE 14
Goulds Water Technology
Commercial Water
Model 15AI/BF / Size (Tamaño) 4 x 6 – 13 NOTE: Not recommended for operation beyond printed Optional Impeller
H-Q curve. Impulsor optativo
METERS FEET RPM 1750 Curve (Curva) CN0664R00 NOTA: No se recomienda para funcionamiento superior al impreso
METROS PIES IMP. DWG. No. 276-44 Casing Dwg. : 279-19 en la curva H-Q. Ordering Code Dia.
200 Código de pedido Diá.
6' NPSHR – FEET (PIES)
A 76 % EFF
A 12 7⁄8"
8' 80 82 C 12¼
175
10'
12' E 113⁄8
50
C 82 80 G 107⁄8
84
150 16' 76 J 10¼
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
E
20' L 9 3⁄8
40 G
125 72 NOTE: Pump will pass a
J sphere to 7⁄16" diameter.
68 NOTA: La bomba dejará
30 100 L pasar una esfera de
hasta 7⁄16 de pulgada de
diámetro.
75
20
15 HP
50
50 HP
40 HP
10
25 30 HP
25 HP
20 HP
0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 U.S. GPM
Model 15AI/BF / Size (Tamaño) 4 x 6 – 13 NOTE: Not recommended for operation beyond printed Optional Impeller
H-Q curve. Impulsor optativo
METERS FEET RPM 1750 Curve (Curva) CN0665R00 NOTA: No se recomienda para funcionamiento superior al impreso
METROS PIES IMP. DWG. No. 276-44 Casing Dwg. : 279-19 en la curva H-Q.
Ordering Code Dia.
200 Código de pedido Diá.
M 6' NPSHR – FEET (PIES) M 131⁄16"
76 % EFF
8' 80 B 12½
175 82
10' D 11 7⁄8
B 12' 82
50 F 111⁄16
D 80
150 16' 76 H 10½
84
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
20'
K 9 7⁄8
F
40 72 NOTE: Pump will pass a
125 H
sphere to 7⁄16" diameter.
K 68 NOTA: La bomba dejará
pasar una esfera de
30 100
hasta 7⁄16 de pulgada de
diámetro.
75
20
15 HP
50
50 HP
10
30 HP
25 40 HP
20 HP 25 HP
0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 U.S. GPM
PAGE 15
Goulds Water Technology
Commercial Water
Model 18BF / Size (Tamaño) 6 x 8 – 13 NOTE: Not recommended for operation beyond Optional Impeller
printed H-Q curve. Impulsor optativo
METERS FEET RPM 1780 Curve (Curva) CN0445R00 NOTA: No se recomienda para funcionamiento superior
Ordering Code Dia.
METROS PIES IMP. DWG. No. 278-10 al impreso en la curva H-Q.
Código de pedido Diá.
250
4' NPSHR – FEET (PIES) A 13"
70 B 12½
200
60% EFF. 70 5' C 125⁄16
74 78 82 7'
A D 117⁄8
60 175 84
B 85 E 115⁄8
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
9'
C
F 111⁄8
50 150 D 85 11'
G 107⁄8
E 84
H 10½
F 82
125 J 10
40 G
H K 9½
J 75
100 HP NOTE: Pump will
K
30 60 pass a sphere to 7⁄8"
HP diameter.
75 50
HP
NOTA: La bomba dejará
20 40 pasar una esfera de
HP hasta 7⁄8 de pulgada de
50 30
HP diámetro.
10
25
0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 U.S. GPM
0 50 100 150 200 250 300 350 400 450 500 m 3∨hr
CAPACITY (CAPACIDAD)
C
140 86 F 11¼
86 20'
40 D G 107⁄8
85
120 H 913⁄16
E 24'
F 80 NOTE: Pump will
30 100 pass a sphere to 7⁄8"
G 15 diameter.
0H
P
80 NOTA: La bomba dejará
H pasar una esfera de
12
20 5H hasta 7⁄8 de pulgada de
60 10 P
0H diámetro.
P
75
40 HP
10
60
20 HP
0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 U.S. GPM 5000
0 100 200 300 400 500 600 700 800 900 1000 m 3∨hr 1100
CAPACITY (CAPACIDAD)
PAGE 16
Goulds Water Technology
Commercial Water
Model 20BF / Size (Tamaño) 4 x 6 – 16 NOTE: Not recommended for operation beyond printed Optional Impeller
H-Q curve. Impulsor optativo
METERS FEET RPM 1780 Curve (Curva) CN0447R01 NOTA: No se recomienda para funcionamiento superior al
METROS PIES
IMP. DWG. No. 278-14 impreso en la curva H-Q. Ordering Code Dia.
350 Código de pedido Diá.
70 A 16"
60% EFF. 5' NPSHR – FEET (PIES)
65
B 155⁄8
A
300 70
60 B 73 C 153⁄16
6' 74
C
74
D 14½
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
8' 73
250 E 3¾
50 D
10' NOTE: Pump will
E pass a sphere to 5⁄8"
200 10 diameter.
40 0H
P NOTA: La bomba dejará
pasar una esfera de
150 75 hasta 5⁄8 de pulgada de
30 HP diámetro.
60
100 HP
20
10 50
0 0
0 200 400 600 800 1000 1200 U.S. GPM 1400
0 100 200 300 400 500 600 700 800 900 m3∨hr
CAPACITY (CAPACIDAD)
20 P E 115⁄8
4' F 111⁄8
60 E 84
F 25 G 107⁄8
H
80 P H 10½
15 50 G
J 10
H
70 K 9½
40 J 20
HP
K NOTE: Pump will
10 pass a sphere to 7⁄8"
30 15 diameter.
HP
NOTA: La bomba dejará
20 pasar una esfera de
5 10
HP
hasta 7⁄8 de pulgada de
7.5 diámetro.
HP
10
0 0
0 200 400 600 800 1000 1200 1400 U.S. GPM 1600
0 50 100 150 200 250 300 350 m 3∨hr
CAPACITY (CAPACIDAD)
PAGE 17
Goulds Water Technology
Commercial Water
Model 19BF / Size (Tamaño) 8 x 10 – 13 NOTE: Not recommended for operation beyond Optional Impeller
printed H-Q curve. Impulsor optativo
METERS FEET
RPM 1180 Curve (Curva) CN0448R02 NOTA: No se recomienda para funcionamiento
Ordering Code Dia.
METROS PIES IMP. DWG. No. 278-36 superior al impreso en la curva H-Q.
Código de pedido Diá.
80
3' NPSHR – FEET (PIES)
J 60% EFF. J 13"
70 5'
80 K 12¾
70 K
85 L 123⁄8
L
20 8' M 1115⁄16
86
60 N 1111⁄16
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
M
85
P 11¼
N
50 Q 107⁄8
15 P 80
10' R 913⁄16
Q
NOTE: Pump will
40
pass a sphere to 7⁄8"
R 40 diameter.
HP
10 NOTA: La bomba dejará
30 30
HP pasar una esfera de
hasta 7⁄8 de pulgada de
25 diámetro.
20 HP
20
5 HP
15
HP
10
0 0
0 500 1000 1500 2000 2500 3000 U.S. GPM 3500
51
F 7
50
C 48 NOTE: Pump will pass a
45% EFF sphere to 5⁄32" diameter.
D NOTA: La bomba dejará
60 200 pasar una esfera de
E hasta 5⁄32 de pulgada de
F diámetro.
25
HP
20
HP
15
30 100
H
10
P
HP
0 0
0 50 100 150 200 250 300 U.S. GPM
0 10 20 30 40 50 60 70 m3∨hr
CAPACITY (CAPACIDAD)
PAGE 18
Goulds Water Technology
Commercial Water
Model 7AI/BF / Size (Tamaño) 21∨2 x 3 – 8 NOTE: Not recommended for operation beyond printed H-Q curve. Optional Impeller
NOTA: No se recomienda para funcionamiento superior al impreso Impulsor optativo
RPM 2900 Curve (Curva) CN0298R00 en la curva H-Q.
IMP. DWG. No. 114-50 Ordering Code Dia.
METERS FEET Código de pedido Diá.
METROS PIES
NPSHR – FEET (PIES) A 7 15⁄16"
5' 6' 7' 8'
A
40 50 60 10' B 7 7⁄16
60 200 65 68 70 73 75
C 73⁄16
12'
14' D 613⁄16
75
B E 63⁄8
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
73
50 F 6 3⁄16
C
20
150 NOTE: Pump will pass a
HP
D 70 sphere to 5⁄16" diameter.
68
40 NOTA: La bomba dejará
E pasar una esfera de
F hasta 5⁄16 de pulgada de
diámetro.
15
65
H
100
P
30
60% EFF
20 10
HP
7
1 2
∨
H
P
50
10
25
0 50 100 150 200 250 300 350 U.S. GPM
0 10 20 30 40 50 60 70 80 m3∨hr
CAPACITY (CAPACIDAD)
Model 21BF / Size (Tamaño) 21∨2 x 3 – 9 NOTE: Not recommended for operation beyond Optional Impeller
RPM 2900 Curve (Curva) CN0673R00 printed H-Q curve. Impulsor optativo
METERS FEET NOTA: No se recomienda para funcionamiento
METROS PIES IMP. DWG. No. 279-15 superior al impreso en la curva H-Q. Ordering Code Dia.
Código de pedido Diá.
300
90 A A 10 1⁄16"
B 6' NPSHR – FEET (PIES) B 9 7⁄8
64 % EFF
80 C 66 8' C 9½
250 D 68
70 D 9¼
10'
70 12' E 815⁄16
E
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
70 F 8½
F
60 200 68 66
G 83⁄16
G
H
H 8
62
50 J 56
J 7 11⁄16
150 NOTE: Pump will pass a
sphere to 5⁄16" diameter.
40
NOTA: La bomba dejará
pasar una esfera de
30 100 30 HP hasta 5⁄16 de pulgada de
25 HP diámetro.
20 HP
20
15 HP
50
10
0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 U.S. GPM
0 50 100 m3∨hr
CAPACITY (CAPACIDAD)
PAGE 19
Goulds Water Technology
Commercial Water
Model 11AI/BF / Size (Tamaño) 21∨2 x 3 – 10 NOTE: Not recommended for operation beyond Optional Impeller
printed H-Q curve.
METERS FEET RPM 2900 Curve (Curva) CN0301R00 Impulsor optativo
NOTA: No se recomienda para funcionamiento superior al
METROS PIES IMP. DWG. No. 121-37 impreso en la curva H-Q. Ordering Code Dia.
400 Código de pedido Diá.
120
A 10 1⁄16"
NPSHR – FEET (PIES) B 9 7⁄8
8'
% EFF 50 10' C 95⁄8
60 12'
14' D 9
A 63
90 300 E 8 5
⁄8
65
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
B 18'
C 70 F 8¼
65 22'
G 8
D 63
72 H 75⁄8
26'
E 60 J 7 1⁄8
60 200 F
G NOTE: Pump will pass a
sphere to 5⁄16" diameter.
H 50
NOTA: La bomba dejará
J
pasar una esfera de
hasta 5⁄16 de pulgada de
diámetro.
30 100 40
HP
30
25 HP
20 HP
15 HP
HP
0 0
0 100 200 300 400 500 600 700 U.S. GPM
Model 16AI/BF / Size (Tamaño) 3 x 4 – 8 NOTE: Not recommended for operation beyond Optional Impeller
printed H-Q curve. Impulsor optativo
METERS FEET RPM 2900 Curve (Curva) CN376R00 NOTA: No se recomienda para funcionamiento superior
METROS PIES Ordering Code Dia.
IMP. DWG. No. 277-09 al impreso en la curva H-Q.
250 Código de pedido Diá.
A 8 1⁄16"
70
NPSHR – FEET (PIES) 9' B 7 7⁄16
10'
45% EFF 58 D 6¾
A 68 12'
73
60 200 E 63⁄8
76
F 515⁄16
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
15'
76 G 5½
50 B
19'
H 51⁄8
73
150 J 4 5⁄8
D 68
40 NOTE: Pump will pass a
E sphere to 5⁄16" diameter.
58
F
NOTA: La bomba dejará
30 100 pasar una esfera de
G hasta 5⁄16 de pulgada de
30
25
diámetro.
H
P
H
H
P
20
20
H
J 15
P
50 10 HP
HP
71
10 ∨2
HP
5
HP
0 0
0 100 200 300 400 500 600 700 800 U.S. GPM
PAGE 20
Goulds Water Technology
Commercial Water
Model 10AI/BF/ Size (Tamaño) 4 x 5 – 8 NOTE: Not recommended for operation beyond Optional Impeller
METERS FEET RPM 2900 Curve (Curva) CN0319R00 printed H-Q curve. Impulsor optativo
METROS PIES NOTA: No se recomienda para funcionamiento superior
IMP. DWG. No. 120-08 al impreso en la curva H-Q. Ordering Code Dia.
60 200 Código de pedido Diá.
NPSHR – FEET (PIES)
50 15'
60 70 A 7 7⁄8"
75 78
A 80 B 7¾
B 81
50 18' C 7½
C
20' D 7¼
150 81
D 22' E 7
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
80
E
24' F 6¾
40 78
F 26'
G 6½
75
H
6 1
⁄16
G 70
J
5¾
30 100
H
NOTE: Pump will pass a
60% EFF
J sphere to 5⁄16" diameter.
NOTA: La bomba dejará
20 pasar una esfera de
hasta 5⁄16 de pulgada de
40
diámetro.
HP
50 30
HP
25
10 HP
20
HP
15
HP
0 0
0 200 400 600 800 1000 1200 1400 U.S. GPM
F 9 3⁄8
C
62 NOTE: Pump will pass a
30
D 12' sphere to 5⁄16" diameter.
60 NOTA: La bomba dejará
80 pasar una esfera de
E 55 hasta 5⁄16 de pulgada de
20
50 diámetro.
F
40% EFF
40
15 HP
10
10
7 ∨2
HP
1
5
HP
HP
0 0
0 100 200 300 400 500 600 700 U.S. GPM
PAGE 21
Goulds Water Technology
Commercial Water
Model 12AI/BF / Size (Tamaño) 3 x 4 – 10 NOTE: Not recommended for operation beyond Optional Impeller
printed H-Q curve. Impulsor optativo
METERS FEET RPM 1450 Curve (Curva) CN0315R00 NOTA: No se recomienda para funcionamiento superior
METROS PIES IMP. DWG. No. 120-05 al impreso en la curva H-Q. Ordering Code Dia.
Código de pedido Diá.
NPSHR – FEET (PIES) 5' A 10 1⁄16"
25 6' B 9¾
80 50 60 68 70
73 7' C 9
A 75
77 8' D 85⁄8
B
E 81⁄8
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
20 77 10' F 7 5⁄8
60 75
C 73 NOTE: Pump will
D 70 12' pass a sphere to 3⁄8"
68 diameter.
15 E
NOTA: La bomba dejará
60
pasar una esfera de
hasta 3⁄8 de pulgada de
F
40 diámetro.
50% EFF
10
10
20 HP
3
7
1 2
H
∨H
P
5
P
5
HP
10
0 100 200 300 400 500 600 U.S. GPM
Model 14AI/BF / Size (Tamaño) 3 x 4 – 13 NOTE: Not recommended for operation beyond Optional Impeller
RPM 1450 Curve (Curva) CN0317R00
printed H-Q curve. Impulsor optativo
METERS FEET NOTA: No se recomienda para funcionamiento superior
METROS PIES IMP. DWG. No. 276-45 al impreso en la curva H-Q. Ordering Code Dia.
160 Código de pedido Diá.
A 13 1⁄16"
NPSHR – FEET (PIES) 3' B 12 9⁄16
60
70
C 125⁄16
40 73
4'
D 12
A 5'
120 75 F 115⁄16
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
B 6'
76
C 75
G 10¾
7'
D 73
H 101⁄8
30 8'
70 J 91⁄8
F
K 811⁄16
80 G 60 L 8
H M 7 9⁄16
20 30% EFF
J NOTE: Pump will pass a
K sphere to 3⁄8" diameter.
L NOTA: La bomba dejará
40 M pasar una esfera de
20
HP
diámetro.
10
HP
71
∨2
HP
5H
0 P
0
100 200 300 400 500 600 700 800 U.S. GPM
PAGE 22
Goulds Water Technology
Commercial Water
Model 17BF / Size (Tamaño) 4 x 6 – 10 NOTE: Not recommended for operation beyond Optional Impeller
printed H-Q curve. Impulsor optativo
RPM 1450 Curve (Curva) NOTA: No se recomienda para funcionamiento superior
IMP. DWG. 277-78 al impreso en la curva H-Q. Ordering Code Dia.
Código de pedido Diá.
METERS FEET
METROS PIES A 101⁄16"
100 B 99⁄16
30
C 91⁄8
NPSHR – FEET (PIES)
D 811⁄16
6' E 81⁄8
80
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
F 7¾
59% EFF. 69
74 79 NOTE: Pump will
A 81 82 7'
20 pass a sphere to 7⁄16"
10' diameter.
60 B 15 HP
82 NOTA: La bomba dejará
81 pasar una esfera de
C 13'
D 79 hasta 7⁄16 de pulgada de
diámetro.
E 74
40
F
10
10 HP
71/2 HP
20 5 HP
0 0
0 100 200 300 400 500 600 700 800 900 U.S. GPM
Model 15AI/BF / Size (Tamaño) 4 x 6 – 13 NOTE: Not recommended for operation beyond Optional Impeller
printed H-Q curve. Impulsor optativo
METERS FEET
RPM 1450 Curve (Curva) CN0322R00 NOTA: No se recomienda para funcionamiento superior
METROS PIES IMP. DWG. No. 276-44 al impreso en la curva H-Q. Ordering Code Dia.
150 Código de pedido Diá.
M 131⁄16"
140
72 % EFF 6' NPSHR – FEET (PIES) A 12 7⁄8
40 130 M 78 7' 8'
82 B 12½
A 10'
120 C 12¼
B
110
82
12' D 117⁄8
C
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
D
78 E 113⁄8
100 14'
30 E
72 F 11 1⁄16
F
90 G 107⁄8
G
80 H
H 10½
J 62 J 10¼
70 K
20
K 97⁄8
60 L L 9 3⁄8
0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 U.S. GPM
CAPACITY (CAPACIDAD)
PAGE 23
Goulds Water Technology
Commercial Water
Model 18BF / Size (Tamaño) 6 x 8 – 13 NOTE: Not recommended for operation beyond Optional Impeller
printed H-Q curve. Impulsor optativo
METERS FEET RPM 1450 Curve (Curva) CN0451R00 NOTA: No se recomienda para funcionamiento superior Ordering Code Dia.
METROS PIES IMP. DWG. No. 278-10 al impreso en la curva H-Q.
Código de pedido Diá.
140
A 13"
40 2' NPSHR – FEET (PIES)
60% EFF. B 12½
A 70
120 80 4'
C 125⁄16
35 B 84 D 117⁄8
85
C 85 6' E 115⁄8
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
100 D F 111⁄8
30 84 8'
E G 107⁄8
80
F H 10½
25 80
G J 10
40
H HP K 9½
70
20 J
60 NOTE: Pump will
K
30 pass a sphere to 7⁄8"
HP
15 diameter.
15
HP NOTA: La bomba dejará
40 pasar una esfera de
10 25 hasta 7⁄8 de pulgada de
HP
diámetro.
20
20 HP
5
0 0
0 200 400 600 800 1000 1200 1400 1600 U.S. GPM 1800
0 50 100 150 200 250 300 350 m 3∨hr 400
CAPACITY (CAPACIDAD)
Model 19BF / Size (Tamaño) 8 x 10 – 13 NOTE: Not recommended for operation beyond Optional Impeller
printed H-Q curve. Impulsor optativo
METERS FEET RPM 1450 Curve (Curva) CN0449R00 NOTA: No se recomienda para funcionamiento
METROS PIES Ordering Code Dia.
IMP. DWG. No. 278-12 superior al impreso en la curva H-Q. Código de pedido Diá.
120
9' NPSHR – FEET (PIES) A 13"
A
60% EFF.
70 B 12¾
B
80 12'
30 C 123⁄8
100 C 85 15' D 1115⁄16
86 E 1111⁄16
TOTAL DYNAMIC HEAD (CARGA DINÁMICA TOTAL)
D
25 F 11¼
85
80 E 18' G 107⁄8
F
80
H 913⁄16
20 G
NOTE: Pump will pass a
60 75 sphere to 7⁄16" diameter.
HP
H
NOTA: La bomba dejará
15 70 60 pasar una esfera de
HP
hasta 7⁄16 de pulgada de
40 60 50 diámetro.
HP
10
40
HP
30
20 HP
5
0 0
0 500 1000 1500 2000 2500 3000 3500 U.S. GPM 4000
0 100 200 300 400 500 600 700 800 m 3∨hr 900
CAPACITY (CAPACIDAD)
PAGE 24
Goulds Water Technology
Commercial Water
Model 8BF Variable Speed NOTE: Not recommended for operation beyond
printed H-Q curve.
Size (Tamaño) 11/2 x 2 – 10 (Velocidad variable) NOTA: No se recomienda para funcionamiento
FEET
PIES
101/16 Dia. Impeller (Diá. Impulsor) Curve (Curva) CN0453R01 superior al impreso en la curva H-Q.
30
400 0
35 40
45
3200 RPM
50
3000 RPM
300 45
2800 RPM
2600 RPM
30
HP
2400 RPM
200
25
HP
2200 RPM
20
2000 RPM
HP
1800 RPM
15
HP
100 1600 RPM 10
HP
5
HP
0
0 25 50 75 100 125 150 175 200
CAPACITY (CAPACIDAD) U.S. GPM
Model 7BF Variable Speed NOTE: Not recommended for operation beyond
printed H-Q curve.
Size (Tamaño) 21/2 x 3 – 8 (Velocidad variable) NOTA: No se recomienda para funcionamiento
FEET 715/16 Dia. Impeller (Diá. Impulsor) Curve (Curva) CN0454R01 superior al impreso en la curva H-Q.
250
3200 RPM
30
3000 RPM HP
200 25
2800 RPM HP
2600 RPM 20
HP
150
2400 RPM 15
HP
2200 RPM
100 2000 RPM 10
HP
1800 RPM 7.5
HP
1600 RPM
5H
50 3H P
P
0
0 50 100 150 200 250 300 350 400 U.S. GPM 450
CAPACITY (CAPACIDAD)
PAGE 25
Goulds Water Technology
Commercial Water
60% EFF. 66
3000 RPM 70
300
2800 RPM
250
2600 RPM 66
Model 11BF Variable Speed NOTE: Not recommended for operation beyond
printed H-Q curve.
Size (Tamaño) 21/2 x 3 – 10 (Velocidad variable) NOTA: No se recomienda para funcionamiento
FEET 101/16 Dia. Impeller (Diá. Impulsor) Curve (Curva) CN0455R01 superior al impreso en la curva H-Q.
68
300 2800 RPM
2600 RPM 65
250
2400 RPM
60
200
HP
2200 RPM
50
2000 RPM 60
HP
150
1800 RPM
40
30
HP
20 25
15 HP HP
50 HP
10
HP
0
0 100 200 300 400 500 600 700 U.S. GPM 800
CAPACITY (CAPACIDAD)
PAGE 26
Goulds Water Technology
Commercial Water
63
2200 RPM
300 65
2000 RPM
250 63
1800 RPM 60
200
50
1600 RPM HP
150 50
1400 RPM 40
HP
100 30
25 HP
20 HP
15 HP
50 HP
10
HP
0
0 100 200 300 400 500 600 U.S. GPM 700
CAPACITY (CAPACIDAD)
Model 16BF Variable Speed NOTE: Not recommended for operation beyond
printed H-Q curve.
Size (Tamaño) 3 x 4 – 8 (Velocidad variable) NOTA: No se recomienda para funcionamiento superior
FEET 81/16 Dia. Impeller (Diá. Impulsor) Curve (Curva) CN0457R01 al impreso en la curva H-Q.
PIES
58% EFF.
20
3600 RPM (MAXIMUM) 68 10
73
300 0
3400 RPM 76
1800 RPM 30
HP
25 HP
20 HP
50 1600 RPM 15 HP
5 10 HP
HP 7.
5 HP
HP
0
0 100 200 300 400 500 600 700 800 U.S. GPM 900
CAPACITY (CAPACIDAD)
PAGE 27
Goulds Water Technology
Commercial Water
Model 12BF Variable Speed NOTE: Not recommended for operation beyond
printed H-Q curve.
FEET
Size (Tamaño) 3 x 4 – 10 (Velocidad variable) NOTA: No se recomienda para funcionamiento superior
PIES
91/8 Dia. Impeller (Diá. Impulsor) Curve (Curva) CN0458R01 al impreso en la curva H-Q.
500
30
400 (MAXIMUM) 70 0
75
78
3400 RPM
350 80
3200 RPM 78
300 75
3000 RPM
70
250 2800 RPM
60
2600 RPM
200
2400 RPM
Model 14BF Variable Speed NOTE: Not recommended for operation beyond
printed H-Q curve.
FEET Size (Tamaño) 3 x 4 – 13 (Velocidad variable) NOTA: No se recomienda para funcionamiento
PIES 131/16" Dia. Impeller (Diá. Impulsor) Curve (Curva) CN0459R01 superior al impreso en la curva H-Q.
500
(MAXIMUM) 70
400 75 0
78
350 2400 RPM
75
60
250 2000 RPM
50
200 1800 RPM
12
1600 RPM
0
150
HP
1400 RPM
10
0
100
HP
75
60 HP
50 HP
50 40 HP
30 HP
20 HP
HP
0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400
CAPACITY (CAPACIDAD) U.S. GPM
PAGE 28
Goulds Water Technology
Commercial Water
Model 10BF Variable Speed NOTE: Not recommended for operation beyond
printed H-Q curve.
Size (Tamaño) 4 x 5 – 8 (Velocidad variable) NOTA: No se recomienda para funcionamiento superior
FEET
PIES
77/8 Dia. Impeller (Diá. Impulsor) Curve (Curva) CN0460R01 al impreso en la curva H-Q.
30
50% EFF.
3200 RPM (MAXIMUM) 60 70
75
80
200 3000 RPM 82
2800 RPM
Model 17BF Variable Speed NOTE: Not recommended for operation beyond
printed H-Q curve.
FEET
Size (Tamaño) 4 x 6 – 10 (Velocidad variable) NOTA: No se recomienda para funcionamiento superior
PIES 101/16 Dia. Impeller (Diá. Impulsor) Curve (Curva) CN0461R01 al impreso en la curva H-Q.
200
83
80
125
1800 RPM
75
100
1600 RPM
50
HP
75 1400 RPM 40
HP
30
HP
50
20
15 HP
HP
25 10
HP
0
0 200 400 600 800 1000 1200 1400 U.S. GPM 1600
CAPACITY (CAPACIDAD)
PAGE 29
Goulds Water Technology
Commercial Water
Model 15BF Variable Speed NOTE: Not recommended for operation beyond
printed H-Q curve.
FEET Size (Tamaño) 4 x 6 – 13 (Velocidad variable) NOTA: No se recomienda para funcionamiento
PIES 131/16" Dia. Impeller (Diá. Impulsor) Curve (Curva) CN0462R02 superior al impreso en la curva H-Q.
400 30
82
300 2200 RPM 78
72
250 2000 RPM
1800 RPM
200
60
1600 RPM
150
12
5
HP
100
10
0
HP
60 75
50 50 HP HP
40 HP
HP
0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
CAPACITY (CAPACIDAD) U.S. GPM
Model 18BF Variable Speed NOTE: Not recommended for operation beyond
printed H-Q curve.
FEET Size (Tamaño) 6 x 8 – 13 (Velocidad variable) NOTA: No se recomienda para funcionamiento superior
PIES
13" Dia. Impeller (Diá. Impulsor) Curve (Curva) CN0463R01 al impreso en la curva H-Q.
550
450 0
60% EFF.
70 75
400 2600 RPM (MAXIMUM) 82
84
85
350 84
2400 RPM
82
300
2200 RPM
25
250 2000 RPM 0H
P
20
0H
200 1800 RPM P
15
1600 RPM 0H
150 12 P
5H
P
10
100 75 0H
HP P
50
0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200
CAPACITY (CAPACIDAD) U.S. GPM
PAGE 30
Goulds Water Technology
Commercial Water
Model 19BF Variable Speed NOTE: Not recommended for operation beyond
printed H-Q curve.
FEET Size (Tamaño) 8 x 10 – 13 (Velocidad variable) NOTA: No se recomienda para funcionamiento superior
PIES 13" Dia. Impeller (Diá. Impulsor) Curve (Curva) CN0464R01 al impreso en la curva H-Q.
350
85
275 86
2200 RPM
250
35
0H
225 P
2000 RPM
30
200 0H
P
25
175 1800 RPM 85 0H
P
150 80
1600 RPM
20
125 0H
P
1400 RPM
100
15
0H
75 P
50 10
HP 0H
50 75 P
HP
25
0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000
CAPACITY (CAPACIDAD) U.S. GPM
Model 20BF Variable Speed NOTE: Not recommended for operation beyond
printed H-Q curve.
FEET Size (Tamaño) 4 x 6 – 16 (Velocidad variable) NOTA: No se recomienda para funcionamiento superior
PIES
16" Dia. Impeller (Diá. Impulsor) Curve (Curva) CN0465R00 al impreso en la curva H-Q.
700
15
500 0
60% EFF. 65
2200 RPM (MAXIMUM) 70 73
74
400 2000 RPM 73
17
1800 RPM 5H
300 15 P
0H
12 P
1600 RPM 5H
10 P
200 1400 RPM 0H
P
75
HP
50
100 HP
0
0 200 400 600 800 1000 1200 1400 1600
CAPACITY (CAPACIDAD) U.S. GPM
PAGE 31
Goulds Water Technology
Commercial Water
108
ANSI 1045 steel motor 105 106 107
shaft extension (typical)
101
ANSI 1045 extensión del 126
eje del motor de acero
178 (típica)
198
353
199
126 355
103
383
Packed Box Arrangement
408 Caja prensaestopas
370 371
Item Description Materials, Materiales Material Code Engineering Standard
Código de material Norma de ingeniería
No. Descripción All Iron Bronze Fitted
No. Todo Accesorios Cast iron ASTM A48 CL30
1003
Hierro fundido ASTM A48 CL20
Ítem hierro de bronce
Bismuth Bronze – Lead Free,
100 Casing, Carcasa 1003 1618
Bismuth Bronze – Lead Free
101 Impeller, Impulsor 1101 Cast iron ASTM A48 CL20
1001
Casing wear ring, Hierro fundido ASTM A48 CL20
103 1001 1618
Anillo de desgaste de la carcasa ASTM B584, Modified C87500 – Lead Free
1101
Adapter/seal housing, ASTM B584, modified C87500 – Lead Free
108 1001 Packed Box Arrangement, Caja prensaestopas
Adaptador/Cubierta del sello
126 Shaft sleeve, Camisa del eje Item No. Description Materials
No. Ítem Descripción Materiales
178 Impeller key, Chaveta del impulsor AISI Type 300 Series SS
Acero inoxidable serie Lantern ring
198 Impeller bolt, Tornillo del impulsor 105 Teflon®
AISI tipo 300
Aro de linterna
199 Impeller washer, Arandela del impulsor Packing, 5 rings Teflon Impregnated
106
Empaquetadura, 5 aros Impregnado de Teflon
Hex head cap screw (adapter to case), Tornillo
370 107 Gland, Casquillo AISI 316SS
de cabeza hexagonal (del adaptador a la cubierta)
Steel Zinc Platted Grade 5 Shaft sleeve
Hex head cap screw (adapter to motor), 126
Acero SAE 1200 grado 5 Camisa del eje
371 Tornillo de cabeza hexagonal
(del adaptador al motor) Gland stud AISI Type 300 Series Stainless Steel
353
Perno del casquillo Acero inoxidable serie AISI tipo 300
383 Mechanical seal, Sello mecánico See seal chart, Ver tabla del sello
Gland nut
Pipe plug ¼" or 3⁄8", Tapón de tubos de Zinc Platted Steel 355
408 Tuerca del casquillo
¼ de pulgada ó 3⁄8 de pulgada Zinc Platted Steel
BUNA-N – Standard, NOTE: NOTA:
513 O-ring, Anillo en O EPR – Optional Seal housing wear ring (item El anillo de desgaste del compartimiento
Viton – Optional number 203) not shown. See repair de sello (ítem número 203) no se muestra.
parts page for detail. (Required for Consulte la página de piezas de repuesto
all models except 3 x 4 – 10.) para mayor detalle. (Se requiere para todos
los modelos con excepción del 3 x 4 – 10).
Mechanical Seal Chart, Type 21, Tabla para sello mecánico, tipo 21
Item Part No., Pieza Número
No., M-Group, Grupo-M L-Group, Grupo-L Rotary, Stationary, Elastomers, Metal Parts, Intended Duty,
No. 250JM-360TCZ All motors, Rotativo Estacionario Elastómeros Partes Metálicas Servicio previsto
180JM-210JM 210JP-360TCZ* Todos los motores
Ítem M Bearing Frame, L Bearing Frame,
180JP-210CZ* Bastidor de cojinetes M Bastidor de cojinetes L
10K13 10K16 10K84 Ceramic, Cerámica BUNA-N Standard, Estándar
Consult Factory, Carbon, High Temp, Caustic,
10K19 10K20 EPR
Consultar con la fábrica Carbone Sil-Carbide, 316 SS, Alta temp/Caustic
383 Carburo de 316 Acero inoxidable
10K27 10K45 10K112 Abrasive,
silicona Viton Abrasivo
10K64 10K65 10K144 Sil-Carbide
15K17 15K3 15K4 Packed Box Design with BUNA O-Ring, Diseño de prensaestopas empacado con anillo en O de BUNA
* All Packed Box units use JP style motors. Todas las unidades de prensaestopas empacado utilizan motores estilo JP.
PAGE 32
Goulds Water Technology
Commercial Water
108
105 106 107
100
134 112 126
101
178
353
198
199 355
103
333A
L-Group Arrangement
126 Arreglo de grupo en L
382 Packed Box Arrangement
Caja prensaestopas
383
178
353
*
198
355
103 112
PAGE 35
Goulds Water Technology
Commercial Water
J F F H - 4 HOLES
E E L
N A B 4 ORIFICIOS
M NPT DRAIN ADAPTER FOOT
ADAPTER FOOT DRENAJE NPT BASE ADAPTADORA
BASE ADAPTADORA
Pump Dimensions and Weights, Peso y dimensiones de la bomba
Pump Suction Discharge CP DC NPT Drain Wt. (lbs.) Motor Frame, Bastidor del motor
Bomba Succión Descarga Max. Max. DD J K M N R Drenaje W X Y Z Pesos L
NPT (libras) 210 250/280 320 360 400 440
1½ x 2 –10 2* 1½* 341⁄8 6¾ 57⁄8 — — — — 1¼ 77⁄8 3 5½ 105 163⁄8 12¾ — — — —
¼ 6
2½ x 3 – 8 3* 2½* 345⁄8 6¼ 5¼ — — — — 113⁄16 8 33⁄8 5 90 167⁄8 13¼ — — — —
2½ x 3 – 9
373
⁄ 8 7 ⁄8 6 — — — —
1
7½ 2¾ 5½ 95 16 1
⁄ 8 12½ 157
⁄8 16½ — —
2½ x 3 – 10 3 2½ 3½ 3
⁄8 7 ⁄8
7
■ 6 x 8 – 13 8 6 457⁄8 12¾ 10½ 23⁄8 7½ 6½ 5½ 5½ 83⁄8 11 37⁄8 8¾ 290 16¾ 17¼ 17¾ 183⁄8 187⁄8 19¾
■ 8 x 10 – 13 10 8 481⁄8 14¾ 13 23⁄8 7½ 6½ 5½ 6¾ 85⁄8 12¾ 4 10 520 171⁄8 175⁄8 181⁄8 18¾ 19¼ 201⁄8
*Denotes NPT connection. All other connections are for use with ANSI class 150 mating flanges. * Indica conexión NPT Las demás conexiones deben usarse con bridas de contacto ANSI clase 150.
■ Indicates “L” Group pump (dimensions valid for packed box or mechanical seal)., ■ Indica una bomba Grupo “L” (dimensiones válidas para caja empacada o sella mecánico).
Motor Dimensions and Weights (may vary with manufacturer)*, Peso y dimensiones del motor (pueden variar de acuerdo al fabricante) *
Horsepower
Motor Frame
3500 RPM 1750 RPM
A AB B D E F G H P Wt.
Bastidor
Max. Max. 1 Phase 3 Phase 1 Phase 3 Phase Max.
del motor
ODP TEFC ODP TEFC ODP TEFC ODP TEFC
213JP 2¾ 7½ — 10 — 5 — 7½ 7½ 125
9½ 73⁄8 8 5¼ 4¼ ¼ 13
⁄32 95⁄8
215JP 3½ 10 — 15 10 & 15 7½ & 10 — 10 10 155
254JP 41⁄8 — — 20 — — — 15 15 255
11¼ 9 11¾ 6¼ 5 11½
256JP 5 — — 25 20 — — 20 20 280
¼ 17
⁄32
284JP 4¾ — — 30 25 — — 25 25 410
12¼ 12¼ 12¼ 7 5½ 13¼
286JP 5½ — — 40 30 — — 30 30 425
324JP 5¼ — — 50 40 — — 40 40 560
13¼ 13¼ 13½ 8 6¼ 5
⁄16 151⁄8
326JP
6
— — 60 50 — — 50 50 590
21
⁄32
364TCZ 5 5
⁄8 — — 75 60 & 75 — — 60 60 775
17½ 143⁄8 151⁄8 9 7 1 183⁄8
365TCZ 61⁄8 — — — — — — 75 75 1005
404TCZ 61⁄8 1 — — — — — — 100 100 1110
19½ 17½ 165⁄8 10 8 1 20 ⁄8
405TCZ 67⁄8 — — — — — — 125 — 1163
13
⁄16
444TCZ 1 7¼ — — — — — — 150 125 1600
21½ 19 ⁄8 19½ 11 9 1 22½
445TCZ 8¼ — — — — — — — 150 1708
NOTE: NOTA:
1. All pumps shipped in vertical discharge position. For other orienta- 1. Todas las bombas se embarcan con la descarga en posición vertical. Para
tions, remove casing bolts, rotate to desired position, and tighten otras orientaciones, retire los pernos de la carcasa, haga rotar la descarga
3
⁄8 - 16 casing bolts to 37 ft./lbs. torque., ½ - 13 casing bolts to 90 hasta la posición deseada y ajuste los 16 pernos de 3/8 de pulgada a una
ft./lbs. torque. torsión de 37 pies/libra, y los 13 pernos de ½ pulgada a 90 pies/libra.
2. Dimensions in inches, weight in pounds. 2. Dimensiones en pulgadas, peso en libras.
3. Not to be used for construction purposes. 3. No utilizar con fines de construcción.
PAGE 36
Goulds Water Technology
Commercial Water
CP
DISCHARGE
Z R DESCARGA Y W
37⁄8
PUMP X
CENTER- SUCTION
LINE 1.625DIA.
SUCCIÓN 1.624
LÍNEA
CENTRAL
DE LA KEYWAY
BOMBA 3
⁄16 x 3⁄8
2 HOLES DCDD CHAVETERO
.62 DIA. K MAX 3
⁄16 x 3⁄8
6¼ 4 HOLES
9
⁄16 DIA.
4 ORIFICIOS
DRAIN ½
PLUG J
N 3½ 3½ TAPÓN DE
M DRENAJE L 6½ 1
8½
ADAPTER FOOT ADAPTER FOOT
BASE ADAPTADORA BASE ADAPTADORA
NOTE: NOTA:
1. All pumps shipped in vertical discharge position. For other orientations, remove casing 1. Todas las bombas se embarcan con la descarga en posición verti-
bolts, rotate to desired position, and tighten 3⁄8 - 16 casing bolts to 37 ft./lbs. torque., cal. Para otras orientaciones, retire los pernos de la carcasa, haga
½ - 13 casing bolts to 90 ft./lbs. torque. rotar la descarga hasta la posición deseada y ajuste los 16 pernos
2. Dimensions in inches, weight in pounds. de 3/8 de pulgada a una torsión de 37 pies/libra, y los 13 pernos de
3. Not to be used for construction purposes. ½ pulgada a 90 pies/libra.
2. Dimensiones en pulgadas, peso en libras.
3. No utilizar con fines de construcción.
PAGE 37
Goulds Water Technology
Commercial Water
CP
R DISCHARGE
Z Y W
DESCARGA
37⁄8
PUMP
CENTER- X
LINE SUCTION 1.625DIA.
LÕNEA SUCCIÓN 1.624
CENTRAL
DE LA
BOMBA KEYWAY
3
⁄16 x 3⁄8
2 DC DD CHAVETERO
HOLES K MAX 3
⁄16 x 3⁄8
.62 DIA. 6¼ 4 HOLES
9
⁄16 DIA.
4 ORIFICIOS
DRAIN PLUG ADAPTER ½
TAPÓN DE FOOT, BASE J
N 3½ 3½ ADAPTADORA
M DRENAJE L 6½ 1
8½ 8½
ADAPTER FOOT
BASE ADAPTADORA
NOTE: NOTA:
1. All pumps shipped in vertical discharge position. For other orientations, remove casing 1. Todas las bombas se embarcan con la descarga en posición verti-
bolts, rotate to desired position, and tighten 3⁄8 - 16 casing bolts to 37 ft./lbs. torque., cal. Para otras orientaciones, retire los pernos de la carcasa, haga
½ - 13 casing bolts to 90 ft./lbs. torque. rotar la descarga hasta la posición deseada y ajuste los 16 pernos
2. Dimensions in inches, weight in pounds. de 3/8 de pulgada a una torsión de 37 pies/libra, y los 13 pernos de
3. Not to be used for construction purposes. ½ pulgada a 90 pies/libra.
2. Dimensiones en pulgadas, peso en libras.
3. No utilizar con fines de construcción.
PAGE 38
Goulds Water Technology
Commercial Water
CP 3¾ C MAX.
SPACER COUPLING, ACOPLAMIENTO ESPACIADOR
Z R DISCHARGE COUPLING GUARD, PROTECTOR DE ACOPLAMIENTO
AB MAX. Y W 3 ⁄8
7
DESCARGA
1.625 DIA.
1.624 SINGLE PHASE ONLY
MONOFÁSICO SOLAMENTE
X SUCTION
SUCCIÓN
P
MAX.
DC DD (4) HOLES
* MAX.
5
⁄8 DIA.
KEYWAY 3⁄16 x 3⁄8
HD CHAVETERO 3⁄16 x 3⁄8 4 ORIFICIOS
HG NPT
DRAIN
HE HE DRENAJE L HF 1¾
NPT
HA HB
* Dimension will include any special shims required to match pump centerline to motor.
NOTE:
* La dimensión incluye cualquier cuña especial que se requiera para hacer coincidir la
1. All pumps shipped in vertical discharge
línea central de la bomba con el motor. position. For other orientations, remove
casing bolts, rotate to desired position,
and tighten 3⁄8 - 16 casing bolts to 37 ft./
Pump Dimensions and Weights, Peso y dimensiones de la bomba lbs. torque., ½ - 13 casing bolts to 90 ft./
NPT Weight lbs. torque.
Pump Suction Discharge CP DC Drain (lbs) 2. Dimensions in inches, weight in pounds.
Bomba Succión Descarga Max. Max. DD L R W X Y Z
Drenaje Pesos 3. Not to be used for construction purposes.
NPT (libras)
1½ x 2 –10 2* 1½* 217⁄8 6¾ 57⁄8 93⁄8 1¼ 5 3 5½ 155 NOTA:
1¼ 6 1. Todas las bombas se embarcan
2½ x 3 – 8 3* 2½* 223⁄8 6¼ 5¼ 97⁄8 113⁄16 51⁄8 33⁄8 5 140
2½ x 3 – 9 con la descarga en posición
215⁄8 71⁄8 6 91⁄8 7½ 2¾ 5½ 147 vertical. Para otras orienta-
2½ x 3 – 10 3 2½ 3½ 3
⁄8 5
ciones, retire los pernos de la
2½ x 3 – 13 21 ⁄8 8 ⁄8 7 ⁄8 9 ⁄8
7 7 5 3
9 3 7½ 201
3 x 4 – 8 223⁄16 6¼ 53⁄8 97⁄16 ¼ 55⁄16 7 55⁄8 144 carcasa, haga rotar la descarga
hasta la posición deseada y
3 x 4 – 10 4 3 22 7 3⁄8 6½ 9½ 3¾ 51⁄8 7½ 5½ 161
3 ajuste los 16 pernos de 3⁄8 de
3 x 4 – 13 217⁄8 9½ 81⁄8 93⁄8 5 9 7½ 217
pulgada a una torsión de 37
4 x 5 – 8 5 223⁄8 67⁄8 5¾ 97⁄8 3
⁄8 5½ 8 5 161
pies/libra, y los 13 pernos de ½
4 x 6 – 10 4 22½ 85⁄8 7½ 10 4½ 5½ 8½ 31⁄8 7 200
6 pulgada a 90 pies/libra.
4 x 6 – 13 221⁄8 9¾ 81⁄8 95⁄8 5¼ 9 3 7½ 233
2. Dimensiones en pulgadas,
*Denotes NPT connection. All other connections are for use with ANSI class 150 mating flanges. peso en libras.
* Indica conexión NPT Las demás conexiones deben usarse con bridas de contacto ANSI clase 150. 3. No utilizar con fines de cons-
trucción.
Motor and Bedplate Dimensions and Weights (may vary with manufacturer.)
Peso y dimensiones del motor y la placa de asiento (pueden variar de acuerdo al fabricante)
Motor HP @ 1750 RPM - Bedplate Data, Datos de la placa de asiento
Wt.
Frame HP @ 3500 RPM T- Frame Only, Basti- AB C P (lbs.) Weight Motor Bearing Frame
Bastidor dor T únicamente (lbs) Shim Shim, Cuña
Max. Max. Max. Pesos HA HB HD HE HF HG
del Three phase, Trifásico Pesos Cuña del del bastidor
(libras) (libras)
motor ODP TEFC ODP TEFC motor de cojinetes
184T — —
5 5 57⁄8 18 8 95 13⁄4 —
213T — —
7 1⁄2 71⁄2 18 116
73⁄8 95⁄8 1 —
215T 15 —
10 10 191⁄8 136 13 42 101⁄4 51⁄4 381⁄2 4 111
254T 20 15 15 15 215⁄8 266
101⁄8 13 — —
256T 25 20 20 20 233⁄8 264
284TS/T 30 25 25 25 24 ⁄8 392
7
125⁄8 15 15 44 101⁄2 53⁄4 401⁄2 31⁄2 124 — 3
⁄4
286TS/T 40 30 30 30 265⁄8 422
324TS/T 50 40 40 40 1 283⁄4 592
14 ⁄8 173⁄8 12 — 13⁄4
326TS/T 60 50 50 50 301⁄4 634 1
18 48 7 ⁄4 44 ⁄2 4
1
183
364TS/T 75 60 60 60 1 315⁄8 834
15 ⁄8 187⁄8 13 — 23⁄4
356TS/T 100 75 75 75 325⁄8 1000
PAGE 39
Goulds Water Technology
Commercial Water
CP 3¾ C MAX.
SPACER COUPLING, ACOPLAMIENTO ESPACIADOR
Z R DISCHARGE COUPLING GUARD, PROTECTOR DE ACOPLAMIENTO
AB MAX. Y W 37⁄8
DESCARGA
1.625 DIA.
1.624 SINGLE PHASE ONLY
MONOFÁSICO SOLAMENTE
X SUCTION
SUCCIÓN
P
MAX.
DC DD
* MAX. (4) HOLES
KEYWAY 3⁄16 x 3⁄8
HD CHAVETERO 3⁄16 x 3⁄8
5
⁄8 DIA.
4 ORIFICIOS
HG NPT
DRAIN
HE HE DRENAJE L HF 1¾
NPT
HA HB
* Dimension will include any special shims required to match pump centerline to motor.
* La dimensión incluye cualquier cuña especial que se requiera para hacer coincidir la línea NOTE:
central de la bomba con el motor. 1. All pumps shipped in vertical discharge
position. For other orientations, remove
Pump Dimensions and Weights, Peso y dimensiones de la bomba casing bolts, rotate to desired position,
and tighten 3⁄8 - 16 casing bolts to 37 ft./
NPT Weight lbs. torque., ½ - 13 casing bolts to 90 ft./
Pump Suction Discharge CP DC Drain (lbs) lbs. torque.
Bomba Succión Descarga Max. Max. DD L R W X Y Z
Drenaje Pesos 2. Dimensions in inches, weight in pounds.
NPT (libras)
3. Not to be used for construction purposes.
1½ x 2 –10 2* 1½* 24¾ 6¾ 57⁄8 12¼ 1¼ 77⁄8 3 5½ 165
¼ 6
2½ x 3 – 8 3* 2½* 25¼ 6¼ 5¼ 12¾ 113⁄16 8 33⁄8 5 150 NOTA:
2½ x 3 – 9 1. Todas las bombas se embarcan
24½ 71⁄8 6 12 7½ 2¾ 5½ 160
2½ x 3 – 10 3 2½ 3½ 3
⁄8 77⁄8 con la descarga en posición ver-
2½ x 3 – 13 24¾ 87⁄8 75⁄8 12¼
9 3 7½ 215 tical. Para otras orientaciones,
3 x 4 – 8 221⁄16 6¼ 53⁄8 125⁄16 ¼ 83⁄16 7 55⁄8 155 retire los pernos de la carcasa,
4 3
3 x 4 – 10 247⁄8 7 3⁄8 6½ 123⁄8 3¾ 8 7½ 5½ 170 haga rotar la descarga hasta la
3
3 x 4 – 13 24¾ 9½ 81⁄8 12¼ 77⁄8 9 7½ 230 posición deseada y ajuste los 16
4 x 5 – 8 5 25¼ 67⁄8 5¾ 12¾ 3
⁄8 8 5 170 pernos de 3⁄8 de pulgada a una
83
⁄8
torsión de 37 pies/libra, y los 13
4 x 6 – 10 4 253⁄8 85⁄8 7½ 127⁄8 4½ 8½ 31⁄8 7 210
6 pernos de ½ pulgada a 90 pies/
4 x 6 – 13 25 9¾ 81⁄8 12½ 81⁄8 9 3 7½ 245
libra.
*Denotes NPT connection. All other connections are for use with ANSI class 150 mating flanges. 2. Dimensiones en pulgadas, peso
* Indica conexión NPT Las demás conexiones deben usarse con bridas de contacto ANSI clase 150. en libras.
3. No utilizar con fines de cons-
trucción.
Motor and Bedplate Dimensions and Weights (may vary with manufacturer.)
Peso y dimensiones del motor y la placa de asiento (pueden variar de acuerdo al fabricante)
Motor HP @ 1750 RPM - Bedplate Data, Datos de la placa de asiento
Wt.
Frame HP @ 3500 RPM T- Frame Only, Basti- AB C P (lbs.) Weight Motor Bearing Frame
Bastidor dor T únicamente (lbs) Shim Shim, Cuña
Max. Max. Max. Pesos HA HB HD HE HF HG
del Three phase, Trifásico Pesos Cuña del del bastidor
(libras) (libras)
motor ODP TEFC ODP TEFC motor de cojinetes
184T — —
5 5 57⁄8 18 8 95 13⁄4 —
213T — —
7 1⁄2 71⁄2 18 116
73⁄8 95⁄8 1 —
215T 15 —
10 10 191⁄8 136 13 42 101⁄4 51⁄4 381⁄2 4 111
254T 20 15 15 15 215⁄8 266
101⁄8 13 — —
256T 25 20 20 20 233⁄8 264
284TS/T 30 25 25 25 24 ⁄8 392
7
125⁄8 15 15 44 101⁄2 53⁄4 401⁄2 31⁄2 124 — 3
⁄4
286TS/T 40 30 30 30 265⁄8 422
324TS/T 50 40 40 40 1 283⁄4 592
14 ⁄8 173⁄8 12 — 13⁄4
326TS/T 60 50 50 50 301⁄4 634 1
18 48 7 ⁄4 44 ⁄2 4
1
183
364TS/T 75 60 60 60 1 315⁄8 834
15 ⁄8 187⁄8 13 — 23⁄4
356TS/T 100 75 75 75 325⁄8 1000
PAGE 40
Goulds Water Technology
Commercial Water
CP 3¾ C REF.
SPACER COUPLING, ACOPLAMIENTO ESPACIADOR
AB REF. Z R DISCHARGE COUPLING GUARD, PROTECTOR DE ACOPLAMIENTO
Y W 3 ⁄8
7
DESCARGA
1.625 DIA.
1.624 SINGLE PHASE ONLY
MONOFÁSICO SOLAMENTE
X SUCTION
SUCCIÓN
P
REF.
DC DD
MAX. KEYWAY 3⁄16 x 3⁄8 ¾“ DIA.
HD
CHAVETERO 3⁄16 x 3⁄8 4-PLACES
6 NPT ▼
DRAIN ▼
HE HE DRENAJE L HF 2 ⁄8
1
NPT ⁄8
3
HA HB
3756 M & L-GROUP SAE DRIVE DIMENSIONS AND WEIGHTS PACKED BOX
DIMENSIONES Y PESOS DEL MANDO SAE GRUPO L Y 3756 M CAJA PRENSAESTOPAS
CP
Z R DISCHARGE Y W V1 V2
DESCARGA
X
1.625DIA.
SUCTION 1.624
SUCCIÓN
KEYWAY
3
⁄16 x 3⁄8
DD CHAVETERO
3
⁄16 x 3⁄8
K DC
MAX.
* See box below SAE #1 – 5
* Vea el rectángulo abajo
N N NPT DRAIN
2 HOLES DRENAJE NPT J SAE drive number is determined by
.56 DIA. M
the engine flywheel housing size.
2 ORIFICIOS
El número del mando SAE se determina
por el tamaño de la caja del volante del
Dimensions and Weights motor.
Pesos y dimensiones
NPT Drain Weight (lbs.)
Pump Suction Discharge DC
CP DD J K M N R Drenaje W X Y Z Pesos
Bomba Succión Descarga (Max.)
NPT (libras)
1½ x 2 –10 2* 1½* 257⁄16 6¾ 57⁄8 — — — — 1¼ 77⁄8 3 5½ 235
¼ 6
2½ x 3 – 8 3* 2½* 2515⁄16 6¼ 5¼ — — — — 113⁄16
8
33⁄8 5 220
2½ x 3 – 9
253⁄16 71⁄8 6 — — — — 7½ 2¾ 5½ 230
2½ x 3 – 10 3 2½ 3½ 3
⁄8 77⁄8
*Denotes NPT connection. All other connections are for use with ANSI class 150 mating flanges.
Dimensions in inches, weights in lbs. Do not use for construction purposes.
* Indica conexión NPT Las demás conexiones deben usarse con bridas de contacto ANSI clase 150.
* SAE # V1 V2
1, 3, 5 13¼ 1½
Dimensiones en pulgadas, peso en libras. No utilizar para fines de construcción.
2, 4 13 1¾
■ Indicates “L” Group pump., ■ Indica una bomba Grupo “L”.
ción.
PAGE 42
Goulds Water Technology
Commercial Water
3756 M & L-GROUP SAE DRIVE DIMENSIONS AND WEIGHTS MECHANICAL SEAL
DIMENSIONES Y PESOS DEL MANDO SAE GRUPO L Y 3756 M SELLO MECÁNICO
CP
Z R DISCHARGE Y W V1 V2
DESCARGA
X
1.625DIA.
SUCTION 1.624
SUCCIÓN
KEYWAY
3
⁄16 x 3⁄8
DD CHAVETERO
3
⁄16 x 3⁄8
K DC
MAX.
* See box below SAE #1 – 5
* Vea el rectángulo abajo
N N NPT DRAIN
2 HOLES DRENAJE NPT J SAE drive number is determined by the
.56 DIA. M
engine flywheel housing size.
2 ORIFICIOS
El número del mando SAE se determina
por el tamaño de la caja del volante del
Dimensions and Weights motor.
Pesos y dimensiones
NPT Drain Weight (lbs.)
Pump Suction Discharge DC
CP DD J K M N R Drenaje W X Y Z Pesos
Bomba Succión Descarga (Max.)
NPT (libras)
1½ x 2 –10 2* 1½* 229⁄16 6¾ 57⁄8 — — — — 1¼ 5 3 5½ 235
¼ 6
2½ x 3 – 8 3* 2½* 231⁄16 6¼ 5¼ — — — — 113⁄16
51⁄8
33⁄8 5 220
2½ x 3 – 9
225⁄16 71⁄8 6 — — — — 7½ 2¾ 5½ 230
2½ x 3 – 10 3 2½ 3½ 3
⁄8 5
NOTE: NOTA: SAE drives have a splined shaft option - see price
1. All pumps shipped in horizontal 1. Todas las bombas se em- book for ordering information. Spline size is 10T, 1½"
discharge position. For other orienta- barcan con la descarga en diameter.
tions, remove casing bolts, rotate to posición horizontal. Para Los mecanismos impulsores del SAE hacen que una op-
desired position, and tighten 3⁄8 - 16 otras orientaciones, retire los
ción ranurada del eje - considere el libro del precio para la
casing bolts to 37 ft./lbs. torque., ½ - pernos de la carcasa, haga
13 casing bolts to 90 ft./lbs. torque. rotar la descarga hasta la información el ordenar. La talla de la tira es 10T, diámetro
2. Dimensions in inches, weight in posición deseada y ajuste los de 1½”.
pounds. 16 pernos de 3/8 de pulgada a
3. Not to be used for construction una torsión de 37 pies/libra, y Spline Diameter
purposes. los 13 pernos de 1/2 pulgada a Diámetro de
la tira
90 pies/libra.
2. Dimensiones en pulgadas, SPLINE SHAFT OPTION -10T
peso en libras. (Spline Count)
OPCIÓN DEL EJE DE LA TIRA (Cuenta de la tira)
3. No utilizar con fines de cons-
trucción.
PAGE 43
SPECIFICATIONS ESPECIFICACIONES TYPICAL APLICACIONES
APPLICATIONS TÍPICAS
Capacities to: Capacidad hasta: • Booster service • Servicio de refuerzo
1600 GPM (363 m3/hr) at 1600 GPM (363 m 3/hr) a
3500 RPM 3500 RPM
• Spraying systems • Sistemas de rociado
4500 GPM (1020 m3/hr) at 4500 GPM (1020 m 3/hr) a
1750 RPM 1750 RPM
• Irrigation • Sistemas de riego
Heads to: Cargas hasta:
490 feet TDH (150 m) at 490 pies (150 m) carga
3500 RPM dinámica total a 3500 RPM • Water circulation • Circulación de agua
300 feet TDH (90 m) at 300 pies (90 m) carga
1750 RPM dinámica total a 1750 RPM • Liquid transfer • Transferencia de líquidos
Working pressure to: Presión de operación
200 PSIG (14 bars) hasta: • General purpose • Aplicaciones de bombeo
200 PSIG (14 bars) pumping en general
Suction pressure to:
100 PSIG (7 bars) Presión de succión hasta:
100 PSIG (7 bars)
Maximum temperature to:
212°F (100°C) with standard Temperatura máxima:
seal or 250°F (121°C) with 212 °F (100 °C) con sello
optional seal. estándar o
250 °F (121 °C) con sello
Motor:
optativo.
NEMA standard JM frame
for 3656 or T-frame for 3756 Motor:
mechanical seal, JP or T- NEMA JM estándar en el
frame for packed box. Open modelo 3656 y bastidor
drip proof, totally enclosed NEMA T estándar en el
fan cooled and explosion modelo 3756 con sello
proof enclosures available. mecánico, bastidor JP o T
Single phase (115/230 V), para caja prensaestopas.
2-5 HP and three phase Las cubiertas disponibles
(208 – 230/460 V) 2 – 150 son: abierta a prueba
HP are available at 1750 or de filtración, totalmente
3500 RPM. encerrada con enfriamiento
por ventilador y a prueba
Direction of Rotation:
de explosiones. Motores
Clockwise viewed from
monofásicos (115/230 V),
motor end.
2-5 HP y trifásicos (208
– 230/460 V) 2 – 150 HP
disponibles a 1750 ó 3500
RPM.
Dirección de rotación:
Dextrorsa (sentido de las
agujas del reloj) cuando se
mira desde el extremo del
motor.
Xylem, Inc.
2881 East Bayard Street Ext., Suite A
Seneca Falls, NY 13148
Phone (Teléfono): (800) 453-6777
Fax: (888) 322-5877
www.gouldswatertechnology.com
Goulds is a registered trademark of Goulds Pumps, Inc. and is used under license.
Goulds es una marca registrada de Goulds Pumps, Inc. y se utiliza bajo licencia.
© 2011 Xylem Inc. B3656M/L R1 November (Noviembre) 2013