- GENERAL REQUIREMENTS
* must have a Backflow prevention assemby tested by a Certified
Backflow Assembly Tester atleast once a year
* Access and Clearance 305 mm (min.)
bet.assembly and grade floor
* Installations above 1.52 meters requires platform
* Minimum Air Gap for Potable Water 25mm or 1"
* connection may be made to the inlet side of a trap provided an
approved AVB installed not less than 152 mm above the Flood
Level Rim of the fixture
* Backflow prevention for hot water of 43.3 degrees celsius or higher
shall be an approved listed type
- SPECIFIC REQUIREMENT
* Water Closet and Urinal (Flushometer valves)
AVB Critical level atleast 152 mm
Read
Each PRV shall be an approved automatic type with drain and each
such relief valve shall be set at a pressure not more than 1033 kpa
*end of the pipe should be 152 mm to 0.60 m above the ground
and pointing downward, and it shall not be THREADED or CAPPED
Note
Copper Tubing
*Joints Brazed
*Fittings Wrought Copper
*Bitumastic Coating and External Protection
Fiberglass Wrapping
*Split Rigid Casing Underground
- Inspection
shall not be concealed or covered when not tested
- Testing
shall be tested and approved
- Unions
installed within 0.3 meters away from Regulating Equipment,
Water heater, Conditioning Equipment which require removal
Remember
The quantity of water required to be supplied to every plumbing
fixture shall be represented by FIXTURE UNITS
Remember
Water Service Pipe = 19 mm diameter (min.)
- Size of Branches
designed by Taking the Total length of the Supply Piping from
the source of cold water to water heater to the most remote hot water
outlet and assessing the flow values of 75% of the Cold and Hot Water
Demand
- Water Conservation
- Piping installed in Fire Resistive Protection
- Hangers and Supports
*Abrasion
hangers and straps shall not compress, distort, cut, or abrade
the piping and allow free movement of pipe
*Supports
**End of Branches and 4' or 1.219 meters
Change of Directions
** allows free movement but restrict upward movement of
lateral runs to avoid reverse grade
** vertical piping each storey or floor level
** alignment of vertical piping mid storey guide
** trap arms in excess of 3' or 0.914mm
** Closet rings fastened with 1/4" or 6.4 mm above finish
Corrosive resistant fasteners floor
SECTION 614
- Thrust Blocking
*Installations
a.Changes of Directions - Tees and Bends
b. Changes in Sizes - Reducers
c. Stops - Dead ends
d. Valves