Вы находитесь на странице: 1из 9

Project

Table Of Contents Location

Boulevard
Title Sheet 32nd Street

1. Main Level Floor Plan


2. Second Level Floor Plan
3. Basement Floor Plan
4. Building/Wall Sections
5. Exterior Elevations Building Type: R1 Occupancy: 6
6. Interior Elevations Project Data:
SQ Footage: 1st Floor- 1,234.28sqft
7. Door, Materials, and 2nd Floor- 718032sqft

Window Schedule
8. RCP Electrical Sheet

Symbols
Door/Window 621 W. 32nd
Label Renovation

P. Bennett

2/4/2019 12:50:55 PM
Title Sheet
Project number FALL18ART15500
Date 12-10-18
Drawn by KLC
Scale
-Contractor to confirm activity of existing well located under addition.
Well location is approximately 9'-0" from back exterior facade
-Extension should be wood floor joist
-Wood floor plank for patio (Floor joist extended)

A-104
1
-Handrails are 36" tall
-8' Ceiling Height.Refer to RCP and Electrical Sheet for more information
43' - 0 1/2" -All dimensions are from interior face of wall
30' - 4 1/2" 12' - 3 1/2" -Ramp proposal due to ADA
Project Data:

B
8' - 2" 6' - 5 1/2" 5' - 5"
SQ Footage: 1st Floor- 1,234.28sqft
2nd Floor- 718032sqft ADA RAMP

UP
13' - 8"

DN
5' - 9 1/2"

ENTRY

6' - 4"
8' - 0" 6' - 8"
1 3' - 7" 6' - 11"

-
91 SF KITCHEN Project

A-106
22

22

1
Location
4

3' - 1 1/2"
Vent Hood

Boulevard
Range
23
282 SF
10
10' - 6 1/2"

32nd Street

2' - 8"
POWDER ROOM 14 MASTER
24' - 6"

DN

5 MASTER BEDROOM

D
9' - 11 1/2" BATHROOM

A-106
25 SF 7

4 Master
13
8

Elevation
Vanity
Bathroom
LIVING ROOM 182 SF

13' - 10"
70 SF Walk-in Closet
A

9' - 9"
2 Elevation
15

Bedroom
Master
211 SF 24
DINING ROOM LAUNDRY ROOM 24 SF
8' - 2"

3 6

A-104
3
11 SF 4

D
1' - 5"
154 SF

4' - 1 1/2" 10' - 0" 7' - 3 1/2"


7' - 8" 15' - 11"
8' - 3 1/2" 17' - 3 1/2"

D
30' - 7"
B

621 W. 32nd
56' - 8 1/2"

1 FIRST FLOOR
101 Renovation
3/16"= 1'-0"

P. Bennett

2/4/2019 12:50:55 PM
Main Level
Project number FALL18ART15500
Date 12-10-18
Drawn by KLC
Scale 3/16" = 1'-0"
29' - 2"

10' - 2 1/2" 2' - 7 1/2" 15' - 5" 12' - 2 1/2"

CLOSET

6' - 0 1/2"
9

9' - 9"
18 45 SF 17 BEDROOM
Project
14 Location
11

Boulevard
215 SF
GUEST ROOM

7' - 6"
1' - 5"
10
B

32nd Street

1' - 9"
101 SF
24' - 6"

15 21

DN
20 16
BATHROOM
14' - 9"

5
12 CLOSET
BATHROOM

10' - 10 1/2"

10' - 10 1/2"
51 SF 13
11
9' - 5"

50 SF
64 SF

7' - 0" 9' - 6" 7' - 0" 4' - 7"

29' - 2"

-Contractor to confirm activity of existing well located under addition.


621 W. 32nd
Well location is approximately 9'-0" from back exterior facade
-Extension should be wood floor joist
Renovation
1 SECOND FLOOR -Wood floor plank for patio (Floor joist extended)
-Handrails are 36" tall
102 3/16"= 1'-0" -8' Ceiling Height.Refer to RCP and Electrical Sheet for more information P. Bennett
-All dimensions are from interior face of wall
Project Data:

2/4/2019 12:50:56 PM
SQ Footage: 1st Floor- 1,234.28sqft Second Level
2nd Floor- 718032sqft Project number FALL18ART15500
Date 12-10-18
Drawn by KLC
Scale 3/16" = 1'-0"
A-104 I-901
-Contractor to confirm activity of existing well located under addition.

2
Well location is approximately 9'-0" from back exterior facade

A-104
I-901
-Extension should be wood floor joist

2
1
-Wood floor plank for patio (Floor joist extended)
31' - 4 1/2" -Handrails are 36" tall
-8' Ceiling Height.Refer to RCP and Electrical Sheet for more information
-All dimensions are from interior face of wall
Project Data:
14' - 4" 16' - 8 1/2" SQ Footage: 1st Floor- 1,234.28sqft
2nd Floor- 718032sqft

UP
Project
Location

Boulevard
32nd Street

1' - 9"
23' - 11 1/2"

23' - 11 1/2"
1' - 5"

A-104
3
31' - 4 1/2"
621 W. 32nd
Renovation

1 BASEMENT PLAN P. Bennett


103

2/4/2019 12:50:56 PM
3/16"= 1'0" Elevation 2 - a Basement

-
Project number FALL18ART15500
Date 12-10-18

-
Drawn by KLC
Scale 3/16" = 1'-0"
-Refer to Int. Elevations Sheet for further Dimensions
-Refer to Ext. Elevations Sheet for further Dimensions

Second Floor
12' - 7 1/4"

2
I-901

First Floor
2' - 10 1/4"
Grade Project
0' - 0" Location

Boulevard
Building Section 2
3
3/16" = 1'-0"
32nd Street

TOP SILL
Roof
18' - 0"
3 Roof 3/4" SIDING
1/8" WOOD A-104 18' - 0" BATT. INSULATION
FLOORING 2X4 WOOD STUD
3/8" TILE FLOORING
2X8 WOOD JOIST WOOD FLOORING Second Floor
12' - 7 1/4"
3/8" GYP. Second Floor GYPSUM BOARD

BAORD CEILING 12' - 7 1/4" CEILING

1/2" GYP BOARD

2X4 WOOD STUD 1/2" PLYWOOD


SHEATHING

WOOD FLOORING

2X8 WOOD JOIST


First Floor
3/4" WOOD FLOORING HEADER
2' - 10 1/4"
BOTTOM SILL
First Floor

8" FOUNDATION
2' - 10 1/4" FINISH GRADE
Grade
0' - 0"
621 W. 32nd
Grade
0' - 0" 8" FOUNDATION WALL Renovation
4" CONCRETE SLAB
Basement
Basement
FOOTER -4' - 9" P. Bennett
FOOTER -4' - 9" T.O. Footing

2/4/2019 12:50:57 PM
T.O. Footing -5' - 1" Building/Wall Section
-5' - 1"
B.O. Footing B.O. Footing Project number FALL18ART15500
-5' - 9" -5' - 9" Date 12-10-18
Drawn by KLC
Building Section Copy 1 Wall Section Copy 1
1 2 Scale 3/16" = 1'-0"
3/16" = 1'-0" 3/16" = 1'-0"
Roof Roof
18' - 0" 18' - 0"
-Refer to D & W Schedule for more information.
(Door and Window)
-Existing siding and shingle materials will remain.
Home addition will have similar siding and
Second Floor Second Floor shingle materials.
12' - 7 1/4" 12' - 7 1/4" -Refer to Basement, Main, and Second Floor Plan
for further Dimensions

Project
Location
First Floor First Floor

Boulevard
2' - 10 1/4" 2' - 10 1/4"
Grade Grade
32nd Street
0' - 0" 0' - 0"

Basement Basement
-4' - 9" -4' - 9"
T.O. Footing T.O. Footing
-5' - 1" -5' - 1"
South B.O. Footing North
1 2 B.O. Footing
3/16" = 1'-0" -5' - 9" 3/16" = 1'-0"
-5' - 9"

Roof
18' - 0"

Second Floor
12' - 7 1/4"
621 W. 32nd
Renovation
First Floor
2' - 10 1/4"
Grade
0' - 0"
P. Bennett

2/4/2019 12:50:58 PM
Basement Ext. Elevations
-4' - 9"
Project number FALL18ART15500
East T.O. Footing Date 12-10-18
3 -5' - 1"
1/8" = 1'-0" Drawn by KLC
B.O. Footing Scale As indicated
-5' - 9"
1
3 A-104

0' - 10 1/2" A-104

-Refer to D & W Schedule for more information.


(Door and Window)
-Refer to Basement, Main, and Second Floor Plan
for further Dimensions

3' - 11 1/2"
4' - 1 1/2"

1 1/2" THICK
LIMESTONE
COUNTERTOP

Project
1' - 8" 1' - 4 1/2"

Location

4' - 3"
OAK CABINET BASE

Boulevard
2' - 2 1/2"

2' - 7"
2' - 7"
32nd Street
First Floor
2' - 10 1/4"
Master Bedroom Elevation Guest Bathroom
2 3
3/8" = 1'-0" 1/2" = 1'-0"

Second Floor
12' - 7 1/4"
1' - 0 1/2"

Existing Brick
Mirror
5' - 0 1/2"

2' - 6"

621 W. 32nd
0' - 1 1/2"
2' - 3 1/2"

8' - 0 1/2"

Renovation
DOUBLE VANITY AND SINK
1' - 6"

KOHLER JACOOZIE
TUB

0' - 1"
4' - 0 1/2"
P. Bennett
2' - 6 1/2"
3' - 0 1/2"

2' - 6"
0' - 3 1/2"

1' - 3 1/2"

2/4/2019 12:50:59 PM
Int. Elevations

0' - 4"
First Floor
2' - 10 1/4" Project number FALL18ART15500
Date 12-10-18
Kitchen Elevation Master Bathroom Vanity Elevation Drawn by KLC
1 4
3/8" = 1'-0" 3/8" = 1'-0" Scale As indicated
Door Schedule 2
Frame
Width Height Door Type Type Mark Thickness

2' - 6" 6' - 8" 4 0' - 1 3/8"


2' - 6" 6' - 8" 5 0' - 1 3/8"
5' - 11" 6' - 10" Integrity Wood 10 0' - 1 3/4"
Wood Ultrex
Ultrex
Outswing
French
Door
5' - 11" 6' - 10" Integrity Wood 11 0' - 1 3/4"
Wood Ultrex
Ultrex
Outswing
French
Door
1' - 11 5/8" 6' - 10 13 Window Examples
11/16" 3/16" = 1'-0"
2' - 6" 6' - 8" 14 0' - 1 3/8"
1' - 11 5/8" 6' - 10 15
11/16" Door Examples
2' - 6" 6' - 8" 16 0' - 1 3/8" 3/16" = 1'-0"
4' - 0" 6' - 8" 17 0' - 2"
4' - 0" 6' - 8" 18 0' - 2"
Window Schedule 2
1' - 11 5/8" 6' - 10 20
11/16" Mark Count Sill Height Width
2' - 6" 6' - 8" 21 0' - 1 3/8"
3' - 6" 7' - 3" 22 8 1 3' - 2" 2' - 4"
5' - 11" 6' - 10" Integrity Wood 23 0' - 1 3/4" 9 1 3' - 2" 2' - 4" 621 W. 32nd
Wood
Ultrex
Ultrex 12
15
1
1
3' - 0"
3' - 0"
2' - 4"
2' - 0"
Renovation
Outswing
French 16 1 3' - 2 1/2" 6' - 6 3/4"
Door 17
19
1
1
2' - 7 1/2"
-0' - 11 1/2"
6' - 6 3/4"
8' - 6 15/16"
P. Bennett
2' - 6" 6' - 8" 24 0' - 1 3/4"
0' - 0" 0' - 0" 26 20 1 2' - 7 1/2" 6' - 6 3/4"

2/4/2019 12:50:59 PM
0' - 0" 0' - 0" 27 21 1 2' - 7 1/2" 6' - 6 3/4"
D,M, & W Schedule
Project number FALL18ART15500
Date 12-10-18
Drawn by KLC
Scale 3/16" = 1'-0"
-8' Ceiling Height.Refer to RCP and Electrical Sheet for
more information

$$
UP

GFCI
- Refer to Floor Plan for Room Tags and Dimensions

LEGEND:
Pendant Light $ Switching Intent

Recess Can Light Outlet

GFCI

Vent Hood
GFCI Ground Fault

Range
Fan w/ Light Circuit Interuptor
$$$

GFCI

$$
GFCI
DN

$
$$
$$

$$
Project
Location

Boulevard
32nd Street

$$
$

621 W. 32nd
Renovation

$
$$

$$
DN
$$
$$

P. Bennett
$

2/4/2019 12:50:59 PM
RCP Electrical
Project number FALL18ART15500
Date 12-10-18
Drawn by KLC
Scale 3/16" = 1'-0"

Вам также может понравиться