Вы находитесь на странице: 1из 4

s Introduction Overview,

Selection guide

SITOP power Single-phase,


output currents up to 2 A
Standard 24 V

Single-phase,
output currents 2.5 to 4 A

SITOP Single-phase,
output current 5 A

Power supplies Single-phase,


output current 10 A
SITOP power
LOGO!Power Single-phase/two-phase,
output current 20 A

Three-phase,
Catalog KT 10.1 · 2002 output currents 10 to 40 A

Supersedes: Catalog KT 10.1 · 1999


Uninterruptible
power supplies

Accessories

The products contained in this


catalog are also available from
CD ROM catalog CA 01 SITOP power
Order No.:
E86060-D4001-A110-B5-7600 Alternative voltages

Please contact
your local SITOP power
Siemens representative Customized

SITOP power
Further information and news on SITOP AS interface power supplies
can also be found on the internet at:
http://www.siemens.com/sitop
LOGO!Power

Technical information
and configuring notes

The products and systems decribed


in this catalog are manufactured
under application of a quality Dimension drawings
management system certified
by DQS in accordance with
DIN EN ISO 9001 (Certificate
Registration No.: 1108).
The DQS Certificate is recog- Appendix Service & Support
nized in all EQ Net countries Indexes
(Reg. No.: 1108). Contact persons
Conditions of sale/delivery
© Siemens AG 2002
SITOP power
Introduction
Power supplies SITOP power

Unstabilized power supplies Features Unstabilized power supply (basic connection diagram)
The AC line voltage is trans- • High efficiency Line isolation Rectification Filtering
formed into a low voltage by The efficiency of approxi-
means of a 50 Hz (60 Hz) mately 90 % keeps current
transformer and rectified. consumption low and the
The DC voltage varies cabinet cool.
+
according to supply voltage • Simple installation 50 Hz Vout
and current load. The low weight and mount- ~
ing assistance allow for rap-
Stabilized power supplies id and inexpensive
(switched-mode) installation.
A rectified and filtered line
voltage is switched at a high • Low space requirement
frequency. With their high power densi-
ty, the units take up little G_KT01_en_00067
The generated pulse train is space in the cabinet or in
then again rectified and fil- machines, etc.
tered. • Precise output voltage
The output voltage can be The precise output voltage
regulated via the duty factor of 24 V DC is available even
or switching frequency. with severe AC supply fluc-
tuations. The loads are pro-
The switching operation takes tected against overload
place either on the mains side peaks. This extends the ser-
(primary switched-mode regu- vice life and reduces down-
lator) or on the low-voltage times.
side (secondary switched- • Low residual ripple
mode regulator). The low residual ripple
of < 0.4 % allows even volt-
The SITOP 24 V DC power
age sensitive loads to be op-
supplies are switched on the
erated.
primary side. The output volt-
age is stabilized via the duty • Integrated short-circuit pro-
factor, the switching fre- tection
quency is constant. Additional protection of the
lines in the 24 V DC circuit is
not required.
• Safe electrical isolation
The Vout output is isolated
from the input galvanically.
This electric isolation en-
sures that no dangerous
voltages can develop at the
output.
• Compliance with national
and international standards,
such as
EMC according to
EN 50081-1/-2 and
EN 50082-1/-2
Output voltage SELV ac-
cording to EN 60950
UL/cUL approval
No release of silicone
FM (American standard for
process engineering sec-
tors)

1/2 Siemens KT 10.1 · 2002


SITOP power
Introduction
Power supplies

Stabilized power supply (basic connection diagram)

Line isolation Rectification Filtering

+
... kHz
50 Hz +
~
PWM
Vout

G_KT01_en_00068

Siemens KT 10.1 · 2002 1/3


SITOP power
Introduction
Selection guide
In order to assist you in finding the right stabilized power supply tained in this catalog sorted according to input voltage, output
for each application as quickly as possible, we have assembled voltage and output current. For more details on each device
the following table as an overview listing all power supplies con- please refer to the cited pages in the catalog.

■ Selection guide
Input voltage Alternating voltage Direct voltage
120 to 230 V 500 to 600 V 400 to 500 V 24 V DC 48 to 110 V 120 to 230 V
Output Output Order No. AC two-phase three-phase DC DC
voltage current AC AC

5 V DC 3A 6EP1 311-1SH01 page 13/2


6.3 A 6EP1 311-1SH11 page 13/6
12 V DC 1.9 A 6EP1 321-1SH01 page 13/2
4.5 A 6EP1 322-1SH01 page 13/6
15 V DC 1.85 A 6EP1 351-1SH01 page 13/2
4A 6EP1 352-1SH01 page 13/6
2 x 3.5 A 6EP1 353-0AA00 page 10/4
24 V DC 0.375 A 6EP1 731-2BA00 page 2/2
0.5 A 6EP1 331-2BA10 page 2/2
1.3 A 6EP1 331-1SH01 page 13/3
2A 6EP1 331-2BA00 page 2/2
6ES7 307-1BA00-0AA0 page 2/3
6ES7 305-1BA80-0AA0 page 2/3
6EP1 732-0AA00 page 2/3
2.5 A 6EP1 332-1SH12 page 3/2 page 3/2
6EP1 332-1SH41 page 13/7
3.5 A 6EP1 332-1SH31 page 3/2
4A 6EP1 332-1SH22 page 3/2 page 3/2
5A 6EP1 333-2BA00 page 4/2
6EP1 333-2AA00 page 4/2
6ES7 307-1EA80-0AA0 page 4/3
6ES7 307-1EA00-0AA0 page 4/2
6EP1 333-1AL11 page 4/3
10 A 6EP1 334-2BA00 page 5/2
6EP1 334-2AA00 page 5/2
6EP1 334-2CA00 page 5/2
6ES7 307-1KA00-0AA0 page 5/3
6EP1 334-1AL11 page 5/3
6EP1 334-1SH01 page 5/3 page 5/3
6EP1 434-2BA00 page 7/6
20 A 6EP1 336-2BA00 page 6/2
6EP1 536-2AA00 page 6/2
6EP1 436-3BA00 page 7/2
6EP1 436-2BA00 page 7/6
30 A 6EP1 437-2BA00 page 7/7
40 A 6EP1 437-3BA00 page 7/2
6EP1 437-2BA10 page 7/7
24 V DC UPS 15 A 6EP1 931-2EC01 page 8/2
6EP1 931-2EC11 page 8/2
40 A 6EP1 931-2FC01 page 8/6
2.5 Ah 6EP1 935-6MD31 page 8/10
3.2 Ah 6EP1 935-6MD11 page 8/11
7 Ah 6EP1 935-6ME21 page 8/12
12 Ah 6EP1 935-6MF01 page 8/13
30 V DC (ASi) 2.4 A 6EP1 632-1AL01 page 12/3
7A 6EP1 354-1AL01 page 12/2
48 V DC 0.65 A 6EP1 351-1SH11 page 13/3
1.25 A 6EP1 352-1SH11 page 13/7
3-52 V DC 10 A/120 W 6EP1 353-2BA00 page 10/2

1/4 Siemens KT 10.1 · 2002

Вам также может понравиться