A4 Hilti Wall Chart 7/5/04 11:04 AM Page 1

Medium and Heavy Duty


Anchoring Systems

CHEMICAL ANCHORS
HVU adhesive anchor
Base material:
■ Concrete, hard natural stone (also in wet or damp conditions)
Applications:
HVU capsule ■ Where high loading capacity, small distance from edge and between
anchors is needed and no expansion force is allowed.
Material:
■ Styrene-free vinylurethane resin (HVU)
HAS anchor rod ■ HAS rod, steel zinc plated (grade 5.8, M8-M24. grade 8.8,
M30 & M36), hot-dipped galvanised, 316 grade stainless steel
■ HIS-N internally threaded sleeve, steel zinc plated, 316 grade
stainless steel
HIS-N internally threaded sleeve Use:
■ Capsule with anchor rod (HAS) or int. threaded sleeve (HIS-N)

For external thread HAS


Thread Hole Hole Max thickness Nrec Vrec Edge dist.min. Spacing min. Tightening Foil capsule Threaded rod,
size diameter depth fastened (kN) (kN) (tension) (tension) torque designation or sleeve
(mm) (mm) (mm) fc,cyl = 25 MPa fc,cyl = 25 MPa (mm) (mm) (Nm) designation
M8 10 80 14 9.3 5.6 80 160 18 HVU M8 x 90 HAS M8
M10 12 90 21 12.5 9.0 90 180 35 HVU M10 x 90 HAS M10
M12 14 110 28 17.9 13.1 110 220 60 HVU M12 x 110 HAS M12
M16 18 125 38 26.0 24.7 140 250 120 HVU M16 x 125 HAS M16
M20 24 170 48 47.2 38.6 180 340 260 HVU M20 x 170 HAS M20
M24 28 210 54 67.9 55.6 210 420 450 HVU M24 x 210 HAS M24
M30 35 270 70 109.2 142.4 270 540 950 HVU M30 x 270 HAS M30
M36 40 330 90 152.5 208.2 330 660 1500 HVU M36 x 330 HAS M36

Loads are based on HAS rod grade 5.8 steel ( M 8 - M 24) and grade 8.8 ( M 30 - M 36)
For internal thread HIS - N
Thread Hole Hole Thread Nrec Vrec Edge dist.min. Spacing min. Tightening Foil capsule Threaded rod,
size diameter depth length (kN) (kN) (tension) (tension) torque designation or sleeve
(mm) (mm) (mm) fc,cyl = 25 MPa fc,cyl = 25 MPa (mm) (mm) (Nm) designation
M8 14 90 8 - 20 8.7 6.3 90 180 15 HVU M10 x 90 HIS-N M8
M10 18 110 10 - 25 13.8 9.9 110 220 28 HVU M12 x 110 HIS-N M10
M12 22 125 12 - 30 20.1 14.5 140 250 50 HVU M16 x 125 HIS-N M12
M16 28 170 16 - 40 37.4 26.9 180 340 85 HVU M20 x 170 HIS-N M16
M20 32 205 20 - 50 58.6 42.0 210 410 170 HVU M24 x 210 HIS-N M20

Tensile values are for HIS-N (derived using grade 5.8 bolts)
Shear (steel failure):rod or bolt of steel grade 5.8

IMPORTANT INFORMATION FOR ALL ANCHORS


Edge distance min. and spacing min. refer to the minimum edge distance and spacing to
Nrec = Recommended safe working tensile load (static)
retain full load capacity in tension. For shear loads and closer edge dist. or spacing refer to the
Vrec = Recommended safe working shear load (static)
Hilti Fastening Technology Manual or contact your Hilti Field Engineer.
Loads stated are safe working loads under nominal conditions.

“TOOLS THAT MAKE YOU MONEY!”