CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Post-Tensioned Masonry Shear Wall Design Based on TMS 402-16/13 (SD Method)
DESIGN CRITERIA
1. The Post-Tensioned Masonry Shear Wall can be as the Self-Centering Lateral Frame, which is good against to seismic/wind loads.
2. The PT walls use smooth steel rods as the post-tensioned rods, in lieu of soft tendons, so easy construction.
3. The PT walls can be the exterior walls with the energy savings of LEED Gold, because no grouted all cells were required.
INPUT DATA & DESIGN SUMMARY
REBAR YIELD STRESS fy = 60 ksi
MASONRY (CMU) STRENGTH fm' = 3 ksi
LENGTH OF SHEAR WALL L= 12 ft
(within vertical control joints)
EQUIVALENT THICKNESS t= 7.25 in
EFFECTIVE HEIGHT OF WALL h= 16 ft
ANALYSIS
CHECK FLEXURAL & AXIAL CAPACITY
PT + Pu = 325 kips
500
< fPn = 1013 kips, (TMS 402 9.3.4.1.1)
0 Mu = 900 ft-kips
0 500