Вы находитесь на странице: 1из 2

0504187-PRO-DS-001 SHEET 1 OF 2

DATASHEET FOR ON/OFF VALVE (XV-001)

OIL AND GAS DEVELOPMENT COMPANY LTD.


OGDCL House, Plot No.3, Jinnah Avenue, Blue Area, Islamabad, Pakistan.
Telephone: +92-51-9209811-18 + 92-51-2623101-02, 04-06
Fax: +92-51-2623113-18; Website: www.ogdcl.com

PETROCHEMICAL ENGINEERING CONSULTANTS PEC


C-2, BLOCK NO. 17, GULSHAN-E-IQBAL, NEAR NATIONAL STADIUM KARACHI-75300, PROJECT NO.
PAKISTAN
TEL: +92 21 34961088 & 34827780, 'FAX : +92 21 34961089
0504187
E-MAIL: contact@pcec.com.pk WEBSITE : www.pcec.com.pk

PROJECT DESIGN OF PERMEATE GAS SALES SYSTEM AT SINJHORO GAS FIELD

TITLE DATASHEET FOR ON/OFF VALVE (XV-001)

DOCUMENT No. 0504187-PRO-DS-001


PREPARED CHECKED APPROVED DATE REV. DESCRIPTION
SHR MT AJ 13-03-19 0 Issued for Review
MT AJ AJ 01-04-19 1 Comments Incorporated
CLIENT CONSULTANT
DESIGN OF PERMEATE GAS SALES SYSTEM AT SINJHORO GAS FIELD

DOCUMENT TITLE DATASHEET FOR EMERGENCY SHUTDOWN VALVE

DOCUMENT NO. 0504187-PRO-DS-001 REV-1


1 Tag No. Quantity XV-001 1
2 Manufacturer Model VTS VTS
3 Contract No. Requisition Item No. VTS VTS
GENERAL 4 Location -
5 P&ID No. 0504187-PID-001
6 Service Gas
7 Line No. 4"-FG-004-B1
8 Valve Code No. API 6D
9 Body Size Body Form 4" Ball/Rotary
10 Body Material ASTM A216 Gr. WCB
11 Connections Rating RTJ Flanged 300 lb
VALVE BODY 12 Flange Finish 125AARH
13 Packing Lubrication & Isolation Note 1 Note 1
14 Bolting Note 1
15 Trim Material Note 1
16 Leakage Class Tight Shut-Off
17 Model No. Speed (RPM) VTS VTS
18 Size VTS

Single acting piston,


19 Actuator Orientation Actuator Form Horizontal in Line
air to open

20 Ingress Protection Electrical Protection IP65 Note 2


21 Power/Air Supply Instrument air at 60 psig (min) to 135 psig (max)
ACTUATOR 22 Action on Air Failure Action on Power Failure Open Open
23 Fireproofing No
24 Solenoid Valve When De-energizes Qty-1 required (see note 3) Closes
25 Limit Switch Closed Limit Switch Open Qty-1 required (see note 4) Qty-1 required (see note 4)
26 Mounting Position Top
27 Additional Switches / Equipment Test switch (see note 5) + filter reg/gauge + VTA
28 Limit Switch Intermediate Qty-1 required (see notes 4 & 6)
29 Power Cable- N/A
ELECTRICAL
30 Control Cable M20x1.5 ISO for each solenoid valve, test and reset switches.
CONNECTIONS
31 Signalling Cable Qty-2 M20x1.5 ISO for limit switch(s) junction box.
32 Fluid HC
33 Fluid Type Phase Gas Single
34 Flow (lb/hr.) Note-7
35 Mole wt. 24.5
36 Compressibility Factor (z) 0.9942
37 Viscosity (cP) 0.0123
38 Cp/Cv 1.294
PROCESS DATA
39 Operating Pressure/ Max. Pressure / Design Pressure (Psig) 16 / 450 / 600
40 Operating Temperature (°F) 100
41 Design Temperature (°F) 180
42 Max. Diff. Pressure for Actuator Size (psi) 100
43 Line Size and Sch. Inlet Outlet 4in-40 4in-40
44 Design 1 sec per inch of nominal bore size
Speed of Operation (seconds)
45 Actual VTS

NOTES:
VTC = Vendor to Confirm
VTS = Vendor to Specify
1. In accordance with API 6D.
2. Area classification is Class I, Zone-I, Gas Group IIA, Temp.class T3
3. Solenoid valve to be direct acting, continuosly rated for 24vdc and certified EExd.
4. Inductive proximity type certified EExia & Namur (DIN 19234). Wired to junction box terminals.
5. Manually operated switch," certified IP65, encapsulated SPDT contacts for use in an intrisically safe (EExia) circuit.
6. Intermediate limit switch for partial closure (5-10%) test. To be used in Buyer's external test cicuit.
7. Vendor to specify rated capacity of valve at gspecified conditions.