Вы находитесь на странице: 1из 59

LOAD BANK

r e n ta l s & s e r v i c es

1
GENERAL INFORMATION

ta b l e o f c o n t e n t s

2 GENERAL INFORMATION 42 POWER DISTRIBUTION

10 RESISTIVE — RESIST / REACTIVE 48 CABLES

24 INDUCTIVE — CAPACITIVE 52 ACCESSORIES

29 DC & ELECTRONIC 58 TRANSPORT

38 MEDIUM VOLTAGE

2
COMPANY OVERVIEW
Leading the Load Bank Industry ComRent operates full service offices and inventory
centers across the globe, making rentals more convenient
in Capacity and Expertise. no matter the location of the job site. All international rentals
are managed through our headquarters in Denver, CO with
When you work with ComRent, you are guaranteed a full access inventory in country and out of country.
seamless rental experience.
For more than 20 years, we have developed protocols Equipment
that set the standard for load banking primary and backup
power sources and systems. ComRent has supplied Load banks: AC, DC, resistive and reactive load banks,
equipment for more testing projects than any other load including medium voltage load banks. ComRent® engineered
bank rental company in North America - 75,000 projects in and is the exclusive provider of “direct connect” medium load
past five years alone. banks – no transformers required.
Unlike other service companies with many business
interests, ComRent remains dedicated to our single mission 3,500 Load Banks (up to 50+ MW)
of providing excellence in load bank testing. Our unrivaled Power Cables Power Quality Monitors
customer service and 99% trouble-free performance and I-Line Panels Switchgear TrakMats
safety records are testaments to our commitment. Voltoc® Medium Voltage Transformers
ComRent’s continuing success is also attributable to
our customers. The DayCor® corona camera provides electric utilities
The insight we’ve gained through working with systems with the ability to determine the health of critical systems
development and management customers has directly components. Visualization of corona, corrosion and electrical
influenced our internal operations. We understand the leakage is easily achieved, providing the time to develop an
business objectives of all who are involved in the systems effective maintenance strategy.
testing process, which is why we offer such a wide range The Cx Monitor™ has raised the bar for the monitoring
of equipment and services, including National Accounts. of power quality, temperature and humidity. It also
ComRent’s National Accounts service is a turnkey offers advanced data collection, storage and reporting
rental service for multi-state customers. A National Account capabilities. System assessments and reporting have
simplifies your procurement and offers significant savings never been faster or easier.
across all of your time sensitive projects.

“ …with (ComRent’s) help


we achieved something the
engineer said couldn’t be
done. This level of service is
what keeps us coming back


time and time again…
— Arthur Kuhn,
Rental Manager
for Cummins Atlantic

3
COMPANY OVERVIEW
Locations
Atlanta, GA Los Angeles, CA
Chicago, IL Newburg, MD
Dallas, TX New York, NY
Denver, CO * Toronto,Canada * Headquarters

Services
Project Scope Collaboration Cable Roll-out+Roll-up
Testing Requirements Technical Support (24/7)
Equipment/Safety Education National Accounts
Logistics Coordination Customized Testing Solutions
Test Site Evaluations

Equipment + Systems Tested


Batteries In-rack Cooling & Air Flow
Building Automation Inverters
Chargers + Exciters Rectifiers
Chillers Solar Arrays Substations
Circuit Breakers Switchgear
Computer Room Air Conditioning Transformers
Diesel Generators Uninterrupted Power Supplies
Fuel Cells Utility Feeders
Fuel & Exhaust Subsystems
Gas Turbines

Markets Served
Aerospace Healthcare
Armed Forces & Government High-Tech
Architectural Firms Industrial Manufacturing
Commissioning Companies Laboratories
Communications Maritime
Data Centers Municipal
Energy/Power Generation Transportation
Engineering Firms Utility Wind Farms
Financial
Generator Service Companies
Green / Renewable Energy

“knowledgeable
...The team was extremely efficient, very
and very thorough in the
execution of the testing…Thanks to them,
we are now firing on all 16 cylinders.

—Simon Zielonka, Systems Engineer for Royal Caribbean

4
LOAD BANK
SOLUTION CENTERS

TORONTO, ON
NEW YORK CITY, NY
CHICAGO, IL
NEWBURG, MD

DENVER, CO
LOS ANGELES, CA

DALLAS, TX ATLANTA, GA

International Services National Accounts


ComRent® provides load bank testing services ComRent’s National Accounts are designed to
internationally. South America, Europe, Asia and simplify procurement for companies who are C
India are among the global locations where we’ve managing multiple projects at varying locations.
provided our services. For more information, As a National Account, our customers receive
contact us at 888-881-7118 or email a member consistent levels of service, pricing, and priority
of our International Projects Team. support. Our strategically placed Inventory Centers
and Sales and support personnel are at your
service. In addition, National Accounts can receive
a single point of contact.

Contact National Accounts Manager


for more information:
888-881-7118
NationalAccounts@comrent.com
5
ROLL-OUT + ROLL-UP SERVICE

Roll-out Service: Roll-up Service:


• Equipment delivery to and from job sites. • Verify lock-out tag-out safety and
• Physically roll-out cables, in a professional and planned disconnection of cables from pigtails.
method, from the working location of the load bank(s) directly • Disconnect all cables, roll-up all cables
to the equipment being tested. and remove cable protectors (if required).
• Management of all cable connections to rental equipment • Inventory and load all rental equipment
and cable protector installation (if required for maximum into our truck(s).
safety).
• Once power is applied, operational performance checks on
the load bank(s) prior to testing, and safety monitoring patrols.

6
FORMULAS

POWER INFORMATION:
The kW rating of the engine-generator set is dependent on the horsepower rating of the
prime mover and the electrical rating of the generator. The kVA rating of the generator is de-
pendent on the current rating of the generator (amps).

kW—Kilowatts kW = kVA x pf

kW
kVA—kilo-volt-amperes kVA =
pf

pf—Power Factor pf = kW
kVA

kVAR—kilo-volt-amperes reactive kVAR = √(kVA2—kW2)

Amperes (Resistive) Per Phase kW x 577


Amps =
(3 phase) E

Amperes (Reactive) Per Phase (3 phase) kVAR x 577


Amps =
( E = volts L-L) E

Voltage Derating:
Load banks are designed to provide a specific capacity at a rated voltage. They cannot be
operated at a voltage higher than their rating without risking damage to the load bank.
The load bank can be operated at lower voltages. Load bank derating is calculated as follows:

Voltage Derating For Power (kW)


Applied Voltage2
=D D x Rated Capacity = Reduced Rating
Rated Voltage2

Voltage Derating For Current (amperage)


Applied Voltage
=D D x Rated Capacity = Reduced Rating
Rated Voltage

7
EQUIPMENT Load Bank Rental List

MODEL VOLTAGE TYPE


AC RESISTIVE
4 kW Rack Mountable 120/208 AC
CRLS11.5 kW Rack Mountable 120/208/230/240 AC
K490 10 kW 120/240 AC
K595 55.5 kW 240/480 AC
Liberty 55 k W 240/480 AC
LPH75 kW 208 AC
L69-80 100 kW 208-240/480 AC
LPH 100/105 kW 240/480 AC
LPH100 100 kW 600 AC
LPC 100 480 or 600 AC
LPH200 200 kW 240/480 AC
LPH100: 100 kW Portable Load Bank
LPH250, K696 240/480 AC
LPH400 400 kW 240/480; 600 AC
LPV700 700 kW 240/480 or 300/600 AC
K575 1250 kW / K580 Trailer 480 or 600 AC
K875A 2000 kW 480 AC
K975A 2000, 2100 kW 600 AC
K975 2500 kW 480 or 600 AC
RESISTIVE/REACTIVE
CR1.875MVA (1500 kW, 1125 kVAR) 380–480 AC
CR3.3MVA (2640 kW, 1980 kVAR) 380–480 or 600 AC
CR4.3MVA (3440 kW, 2580 kVAR) 380–480 AC
CR6.0MVA (4800 kW, 3600 kVAR) 380–480 AC
CR6.25MVA (5000 kW, 3750 kVAR) 380–480 or 600 AC
MEDIUM VOLTAGE CR3.3 Resistive/Reactive LoadBank
AC RESISTIVE
CR922 4MW/5MW 4160/13800 AC
REACTIVE/INDUCTIVE
CR3750 MV 3750 kVAR 4160-14400 AC
REACTIVE/INDUCTIVE
R237 kVAR 240/480 AC
K841, R300, CR300 kVAR 240/480 AC
LT378 kVAR 240/480 AC
R450 450 kVAR 240/480/600 AC
K841B 750 & 1125 kVAR 240/480 AC
ELECTRONIC LOADS
RBL 232 150A 800W 0-50 DC
RBL 488 300A 2000W 0-400 DC
RBL 488 600A 4000W 0-600 DC K841B 1125 kVAR Reactive Load Bank
XBL Series 6000 W DC

8
EQUIPMENT Cables, Transformers, Switchgear

MODEL VOLTAGE TYPE


XBL 200A, 6000 W 0-600 DC
XBL 200A, 4000 W 0-600 DC
XBL 600A, 4000 W 0-100 DC
WCL 488 1000A 12000W & Rack 0-400 DC
WCS 488 1000A 12000W 0-400 DC

CABLES (FREE AIR RATING)

4/0 Cam 2 kV, 405 Amps W


1/0 Cam 2 kV, 260 Amps W
1/0 Cable Extensions 50’ 2 kV 260 Amps W
#4 Ground 2 kV, 149 Amps W
Pigtails, Adapters 4/0 2 kV, 405 Amps W L121 250 Amp DC Resistive Load Bank
Pigtails, Adapters 1/0 2 kV, 260 Amps W in case
Power Cords 50’ / 100’ 120 V SO
VOLTLOC® 2/0, 500MCM 15 kV, 300/685 Amps SH
Cable Winder Machine 4/0 or 1/0 Cables
CABLE ADAPTERS
Multi-taps Insulated 400 Amps
Splitters 400 Amps
Cam Three ways
405 Amps
& Adapters
Lugs
DC RESISTIVE
K492 150 Amp 26/52 DC
T242 220 Amp 24/48 DC
L42-500 Amp, L-29 24/36/48, 28 DC
2500/3500 kVA Transformer
L48-500 Amp 48 DC
K576 500 Amp 52 DC
K571 1000 Amp 28/52 DC
L121-250-60 250 Amp 60 / 120 DC
Torkel 860 12 -480 VDC
CR600 600 kW 300/600 DC
CR1000 600 kW 500/1000 DC
K974A 375/750 DC
TRANSFORMERS
5000/7000 kVA 2.4, 4.16/13.8 kV x 480 AC
2500/3500 kVA 2.4, 4.16/13.8 kVx 480/600 AC
2500 kVA 2.4, 4.16/13.8 kV x 480 AC
4000/5000 kVA 208/480/600 AC
5500/6500 kVA 480 x 600 x 690 AC
500 kVA 600 x 480 AC
SWITCHGEAR
5/15 kV Fused Disconnect (1) 5/15 kV – 1200A AC CR922 5MW Resistive Load Bank

9
RESISTIVE
RESIST/REACTIVE

AC RESISTIVE
4 kW Rack Mountable 120/208 AC
K490 10 kW 120/240 AC
K595 55.5 kW 208-240/480 AC
CRLS 11.5 kW 120/208/230/240 AC
L69-80 100/105 kW 208/480 AC
LPH100/105 kW 240/489 AC
LPC100 D 100kW 240 /480 AC
LPC 100 C 100kW 300 / 600 AC
LPH100 100 kW 600 AC
LPH200 200 kW 240/480 AC
LPH250, K696 240/480 AC
LPH400 400 kW 240/480 AC
LPH400 400 kW 600 AC
LPV700 700 kW 240/480 or 300/600 AC
K575 1250 kW / K580 Trailer 480 or 600 AC
K875A 2000 kW 480 AC
K975A 2000, 2100 kW 600 AC
K975 2500 kW 480 or 600 AC
LT4000 kW 480 AC
CR922 4MW/5MW 4160/13800 AC
CR150 Spirit 480 AC
RESISTIVE/REACTIVE
CR1.875MVA (1500kW 1125 kVAR) 480 AC
CR3.3MVA (2640 kW, 1980 kVAR) 480 or 600 AC
CR4.3MVA (3440 kW, 2580 kVAR) 480 AC
CR6.0MVA (4800 kW, 3600 kVAR) 480 AC
CR6.25MVA (5000 kW, 3750 kVAR) 480 or 600 AC

10
resistive

4 kW
Rack Mountable Load Bank for
Data Centers
4 kW Rack Mounted load banks have
a 2 kW load step. Dual channel for A &
B power feeds. Cool air from the “Cold
Aisle” is drawn from the front and hot
air is discharged throughthe back. Units
are equipped to handle any style of plug
connection. 208 and 120 VAC. Available
exclusively from ComRent®

Total Load kW Voltage Load Step Resolution kW


4 kW 120/208V 1KW @ 120 and 2KW @ 208

Length Width Height Weight / Ship


26” 19” 9” 45 lbs. / 58lbs
66 cm 48.3 cm 22.9 cm 20.4 kg / 26.3 kg

K490
10 kW Portable Load bank
• Compact and simple to operate
• Perfect for small generators & UPS
• Reliable load elements and no
“cool-down” period
• Easy to read meters
• Hand-held multimeter compatible
• Over-temperature protected
• Master load control switch

Total Load kW Voltage Load Step Resolution kW


10 120 VAC .25, .25, .5, 1, 2, 3, 3
10 120/240 VAC 1, 2, 2, 2, 3

Length Width Height Weight / Ship


18” 13” 11” 30 lbs / 76 lbs
48.3 cm 33 cm 33 cm 13.6 kg / 34.5 kg

11
resistive

CRLS 11.5
11.5 kW Rack-mounted load unit
The ComRent® CRLS 11.5 is a load unit with 2
channels, 1 input per channel, that can operate
at independent voltages.
CRLS 11.5 kW at full load
4404 watts @ 120VAC
8554 watts @ 208VAC
10,576 watts @ 230VAC
11,592 watts @ 240VAC

Total Load kW Voltage Protection System

11.5 120/208/230/240 Thermal protection, power supply shut-down, wrong voltage detection.

Length Height Weight / Ship


25” 15.75” (9U) 58 lbs. / 82 lbs.
63.5 cm 40 cm 26.3 kg / 37.2 kg

LIBERTY
55 kW Load Bank

• Rated for continuous operation


• Ultra-compact, portable, easy to transport
and operate
• Large load capacity—up to 55 kW
• Enclosure constructed of lightweight
aluminum and aluminized steel
• Convenient operator controls

Total Load kW Voltage Load Step Resolution kW


55 240/480 VAC, 3-Phase 60 Hz 5, 10, 20, 20

Length Width Height Weight / Ship


23” 13” 24” 69 lbs. / 114 lbs
67.3 cm 41.9 cm 81.3 cm 31.3 kg / 51.7 kg

12
resistive

LPH75
Portable Resistive Load Bank
• Rated for continuous operation
• Ultra-compact, portable, easy to transport and operate
• Large capacity- up to 75 kW
• Enclosure constructed of lightweight aluminum
and aluminized steel
• Convenient operator controls

Total Load kW Voltage Load Step Resolution kW


75 208 VAC, 3-phase, 60Hz 5, 10, 20, 20, 20

Length Width Height Weight / Ship


23” 12.75” 23.75” 78 lbs. / NA
58.4 cm 32.4 cm 60.3 cm 35.4 kg / NA

K595
55.5 kW 240/480 VAC Wye Connected Load Bank

• Great for small generators, UPS’s, and other AC


power sources
• 3-phase (55.5 kW) and single-phase (41.6 kW) with neutral
• Mobile, with casters
• Use three units for applying phase imbalance loads

Total Load kW Voltage Load Step Resolution kW


55.5 240 VAC 60 Hz ½, 1, 2, 4, 8, 16, 24
54 480 VAC 60 Hz 2, 4, 8, 16, 24

Length Width Height Weight / Ship


30” 23” 62” 268 lbs / 420 lbs
76.2 cm 58.42 cm 157.48 cm 121.6 kg / 190.5 kg

13
resistive

LPH100
“Freedom” 100 kW Portable Load Bank

• Rated for continuous operation


• Compact, portable, easy to transport and operate
• Large load capacity—up to 100 kW
• Aluminized steel and aluminum enclosure with casters
• Convenient operator controls with digital metering standard

Total Load kW Voltage Load Step Resolution kW


100 480 VAC, 60 Hz 5, 10, 10, 25, 50
93.75 240 VAC, 60 Hz 3.75, 7.5, 7.5, 25, 50
70.4 208 VAC, 60 Hz 2.81, 5.55, 5.55, 18.75, 37.5
100 600 VAC, 60 Hz 5, 10, 10, 25, 50

Length Width Height Weight / Ship


25” 16.25” 29.12” 108 lbs. / 186 lbs.
63.5 cm 41.3 cm 74 cm 49 kg / 84.4 kg

LPH150S
• Rated for continuous operation
• Control up to10 load banks equaling 1500kW with
a single hand held controller
• Large load capacity—up to 150 kW
• Aluminized steel and aluminum enclosure with casters
• Ability to provide 112.5 kW at 208VAC

Total Load kW Voltage Load Step Resolution kW


150 480 VAC, 60 Hz 5 kW
150 240 VAC, 60 Hz 5 kW
112.5 208 VAC, 60 Hz 3.75 kW

Length Width Height Weight


31.9” 21.8” 37.5” 220 lbs.
81 cm 55 cm 95 cm 99 kg

14
resistive

L69-80
100 kW Portable Load Bank
• Used for testing *208, 240 and 480 VAC power
units *(2 hour duty cycle)
• Compact, easy to transport and operate
• Large load capacity—up to 100 kW
• Aluminized steel enclosure
• Ships in a case for convenience and safety

Total Load kW Voltage Load Step Resolution kW


100 480 VAC, 60 Hz 12.5, 12.5, 25, 25, 25
80 *208 VAC, 60 Hz 10, 10, 20, 20, 20

Length Width Height Weight / Ship


23” 9” 22” 62 lbs. / 112 lbs.
58.4 cm 22.9 cm 55.9 cm 28.1 kg / 50.8

LPC100 D
“Minuteman” 100 kW Portable Load Bank
• Rated for Continuous Operation
• Ultra-Compact, Portable, Easy to Transport and Operate
• Large Load Capacity—up to 100 kW
• Lightweight Aluminized Steel Enclosure—only 65 lbs
• Load Cables and Hard Shell Travel Case are Included
• Convenient Operator Controls with Digital Metering and
Data Logging Software included

Total Load kW Voltage Load Step Resolution kW


100 480/240 VAC 3 phase 12.5, 12.5, 25, 25 and 25 kW
80 208 VAC 3 phase 10, 10, 20, 20 and 20 kW
13.3 120 VAC single phase 1.7, 1.7, 3.3, 3.3 and 3.3 kW
52.8 240 VAC single phase 6.6, 6.6, 13.2, 13.2, and 13.2 kW

Length Width Height Weight


22” 11” 24” 65 lbs.
55.8 cm 27.9 cm 61 cm 30 kg

15
resistive

LPH200-400
200–400 kW Portable Load Bank
• Portable for load testing at multiple sites
• Compact—easy to transport and operate
• Large load capacity—up to 400 kW
• Rugged aluminized steel enclosure with casters
• Convenient operator controls with digital
metering standard
• Intelligent Load Bank Remote Operating system is
available on LPH400s upon request.

Total Load kW Voltage Load Step Resolution kW


200 240/480 5, 10, 10, 25, 50, 100
250 240/480 5, 10, 10, 25, 50, 50, 100
400 240/480 5, 10, 10, 25, 50, 100, 100, 100
400 600 5, 10, 10, 25, 50, 100, 100, 100

Length Width Height Weight / Ship


62” 34” 53” 862 lbs. / 1,240 lbs
157.48 cm 86.4 cm 134.6 cm 391 kg / 562.5 kg

CR150 SPIRIT
150 kW Automatic Control Load Bank
• Load controller monitors power system loads
and automatically adds or subtracts load steps
to maintain a minimum load level on the generator
• Built in ADMS Digital Monotoring System allows
Real-Time Data Acqusition and Data Logging
of Voltage, Current, Frequency, and Power
measurements
• Up to 150 kW at 480VAC, 3-phase, 60Hz Dynamic Loading

Rated kW Rated Voltage Load Step Resolution kW


150 480 VAC 5,10,10,25,50,50
* 180A per phase

Length Width Height Weight


51” 27” 35” 500 lbs.
129.5 cm 68.6 cm 89 cm 227 kg

16
resistive
LPH500
500 kW Portable Load Bank
The LPH 500 load bank is ideal for routine testing and maintenance
of AC power sources such as emergency stand-by generators and
UPS systems.
• Portable for load testing at multiple sites
• Easy to transport and operate
• Large load capacity - up to 500 KW
• Rugged Aluminized steel enclosure with casters
• Convenient operator controls with digital metering standard
• Units supplied with Intelligent Load Bank Remote Operating System upon request

Total Load kW Voltage Load Step Resolution kW


500 240/480 5, 10, 10, 25, 50, 100, 100, 200
375 208 3.75, 7.5, 7.5, 18.75, 37.5, 75, 75, 150
347 400 3.47,6.94, 6.94, 17.35, 34.7, 69.4, 69.4, 138.6

Length Width Height Weight / Ship


72.25” 34” 50.25” 785 lbs. / NA
157.48 cm 86.4 cm 134.6 cm 391 kg / 562.5 kg

XS 665
665 kW Portable Load Bank
The XS665 is a powerful load bank offering a continuous
load at various voltages specifically designed for data center
commissioning. The digital meter synced with ComRent’s
patented remote technology allows you to view power, voltage,
current and frequency. Test within minutes of connecting to a
power source, providing options for blower and control power.

Total Load kW Voltage Load Step Resolution kW


665 480 6.7, 13.3,13.3, 33.3, 66.6, 66.6, 199.7, 266.3
500 416 5, 10, 10, 25, 50, 50, 200

Length Width Height Weight / Ship


68”/72” 35.25”/46” 62”/76.25” 1,400 lbs. / 2,000 lbs
157.48 cm 86.4 cm 134.6 cm 391 kg / 562.5 kg

17
resistive

LPV700
“Patriot” 700 kW Portable Load Bank
• Portable, for load testing at multiple sites
• Compact, easy to transport and operate
• Extra large load capacity—up to 700 kW
• Rugged aluminized steel enclosure with casters
• Convenient operator controls
• Protective shipping cage

Total Load kW Voltage Load Step Resolution kW


700 240/480 VAC, 3-Phase, 60 Hz 5, 10, 10, 25, 50, 100, 100, 200, 200
700 300/600 VAC, 3 Phase, 60 Hz 5, 10, 10, 25, 50, 100, 100, 200, 200

Length Width Height Weight / Ship


61” 34” 75” 1,150 lbs. / 2,000 lbs
155 cm 86.4 cm 190.5 cm 522 kg / 907.2 kg

K575/K580
1250 kW Resistive AC Load Bank
The K575 is a great load bank for testing up
to 1250 kW, 480 or 600 VAC. The unit can either
be towed by regular pick-up truck or placed
on a flat bed. They can be rented in pairs to
test up to 2500 kW. The K580 is a trailer-
mounted load bank which consists of a heavy
duty trailer designed for highway travel with a
permanently mounted K575 load bank.

Total Load kW Voltage Load Step Resolution kW


1250 480 V 50, 100, 200, 200, 200, 500 kW
1250 600 V 50, 100, 100, 200, 200, 200, 200, 200 kW

Length Width Height Weight


228” 94” 79” 4,700 lbs.
579.12 cm 238.76 cm 200.66 cm 2,131 kg

18
resistive

K875A
2000 kW Portable Load Bank
• Vertical air discharge
• Portable—for multiple site load testing
• Multiple units can be placed on a trailer
• Use for 1.0 PF test, or with reactive load bank(s)
for 0.8 PF test

Total Load kW Voltage Load Step Resolution kW


2000 480 50, 50,100, 100, 200, 500, 500, 500

Length Width Height Weight


80” 59” 156” 4,000 lbs.
150 cm 203.2 cm 396.2 cm 1,814.4 kg

K975A
K557
2500 kW Portable Load Bank
• Easy operator controls and remote operation available
up to 1000’
• Compact footprint for space-limited areas; horizontal air discharge
• Multiple units can be placed on a trailer
• Use for 1.0 PF test, or with reactive load bank(s) for 0.8 PF test

Total Load kW Voltage Load Step Resolution kW


1000 240 5, 10, 10, 25, 50, 100, 100, 100, 200, 200, 200
2000 480 5, 10, 10, 25, 50, 100, 100, 100, 200,200, 500, 500
2500 480 50, 50, 100, 100, 200, 500, 500, 500, 500
2000 600 5, 10, 10, 25, 50, 100, 100, 200, 500, 500, 500
2100 600 5, 10, 10, 25, 50, 100, 200, 200, 500, 500, 500
2500 600 50, 50, 100, 100, 200, 500, 500, 500

Length Width Height Weight

97” 82” 93” 4,300 lbs.


246.4 cm 208.3 cm 236.2 cm 1,950.45 kg

19
resistive

CR1.875
1875 kVA Load Bank
• Weather-tight construction that allows testing in
all types of weather
• Excellent control options including a laptop
computer or a hand-held controller
• Programmable testing with the option to record
and save test data
• Fully adjustable power factor
480 VAC Models

kVA kW Power Factor


1875 1500 0.8
1666 1500 0.9

Length Width Height Weight


96” 75” 102” 13,000 lbs.
243.8 cm 190.5 cm 259 cm 5,897 kg

CR3.3MVA
Resistive/Reactive—2640 kW & 1980 kVAR
Portable load bank used to test mission critical
power systems including turbines, generators,
switchgear, and UPS systems. Rugged outdoor
enclosure and proven design ensure successful
completion of your testing mission.

480 & 600 VAC Models

kVA kW Power Factor


3300 2640 0.8
2933 2640 0.9
2640 2640 unity

Length Width Height Weight


10’ 8’ 8’5” 22,500 lbs.
304 cm 243 cm 259 cm 10,206 kg

20
resistive

PRECISION 18KW NEW


Precision 18kW Resistive Load Bank
The Precision has evolved to be the
most comprehensive, flexible and safe
commissioning load bank in the data center
market. ComRent relied on its more than 20
years of experience to engineer the Precision
to meet a variety of project requirements,
and deliver cost savings that meet your
project needs.

17.5”

23.4

19”

Total Load kW Voltage Load Step Resolution kW


18 kW 240, 208, 120 VAC NA

Length Width Height Weight


23.4” 1926” 17.5” 58 lbs.
59.4 cm 4892 cm 44.45 cm 26 kg
Length (in case) Width (in case) Height (in case) Weight (in case)
31” 26” 28” 117 lbs.
78.7 cm 66 cm 71 cm 53.07 kg

21
resistive /reactive

CR4.3MVA
Resistive/Reactive—3440 kW and 2580 kVAR
Portable load bank used to test mission critical
power systems including turbines, generators,
switchgear and UPS systems. Rugged outdoor
enclosure and proven design ensure successful
completion of your testing mission.
480 VAC Models

kVA kW Power Factor


4300 3440 0.8
4047 3440 0.85
3822 3440 0.9
3621 3440 0.95
3440 3440 unity

Length Width Height Weight


239” 96” 102” 30,900 lbs.
599.4 cm 244 cm 259 cm 14,016 kg

CR6.0/CR6.25
Resistive/Reactive
The CR6.0 and CR6.25 are
great for testing a variety
of equipment in the worst
weather conditions. These
powerful load banks are
best suited for turbines,
generators, switchgear, UPS
systems and Rotary UPS.

480 & 600 VAC Models

22
resistive /reactive

CR6.0 4800 kW & 3600 kVAR


kVA kW Power Factor
6000 4800 0.8
5647 4800 0.85
5333 4800 0.9
5052 4800 0.95
4800 4800 unity

Length Width Height Weight


20’ 8’ 8’5” 36,300 lbs.
609.6 cm 243 cm 259 cm 16,465 kg

CR6.25 5000 kW & 3750 kVAR


kVA kW Power Factor
6250 5000 0.8
5882 5000 0.85
5555 5000 0.9
5263 5000 0.95
5000 5000 unity

Length Width Height Weight


20’ 8’ 8’5” 36,520 lbs.
609.6 cm 243 cm 259 cm 16,556 kg

23
INDUCTIVE
CAPACITIVE

INDUCTIVE
R237 kVAR 240/480 AC
K841, R300 240/480 AC
R378 kVAR 240/480 AC
R450 450 kVAR 240/480/600 AC
K841B 750 & 1125 kVAR 240/480 & 480 AC
CR3750MV 3750 kVAR 2400-14400 AC
REACTIVE—400HZ
K597 40 kVAR 208/450 Wye AC
K843 300 kVAR 240/480 AC
CAPACITATOR BANKS
CR500kVARC 480V AC
CR2000 kVARC 480V AC

K841/K843
K596/K597
CR500

24
inductive /capacitive

K596/K597
40 kVAR, 120/208/240/480 VAC, 50/60
Hz & 400 Hz

• Dual voltage operation


• Four-wire Wye configuration
• Provides 0.8 PF when used with 55 kW
resistive load bank
• Non-saturating iron core reactors
• Single and 3-phase voltages

Load Bank Model Total kVAR/Frequency Voltage Load Steps


K596 41.6 kVAR / 60 Hz 240 0.375, 0.75, 1.5, 3, 6, 12, 18
K596 40.5 kVAR / 60 Hz 480 1.5, 3, 6, 12, 18
K597 41.6 kVAR / 400 Hz 208/450 0.375, 0.75, 1.5, 3, 6, 12, 18

Length Width Height Weight / Ship


37” 23” 54” 1,115 lbs. / 1,200 lbs.
94 cm 58.4 cm 137.2 cm 505.8 kg / 544.3 kg

K841/K843
Reactive Load Banks—300 kVAR
50/60 Hz & 400 Hz

• Portable for rental applications


• Designed for continuous operation
• Non-saturating iron core reactors
• 240/480 voltages

kVAR Voltage Frequency Load Step Resolution


300 kVAR 240/480 50/60 & 400 Hz 0-3.75 TO 37.5

Length Width Height Weight


52” 51” 92” 4,350 lbs.
132.1 cm 129.5 cm 233.7 cm 1973.1 kg

25
inductive /capacitive

R300
300 kVAR Inductive Load Bank
The R300 portable inductive load bank provides
loads which can be used to obtain a lagging power
factor. These units correspond to 500kVA loads,
at 0.8 power factor.
This load bank is designed and built with
a 3.75 kVAR load resolution. The R300 has
300 kVAR capacity.

kVAR Voltage Load Step Resolution


300 kVAR 240/480 VAC 3.75, 7.5, 7.5, 18.75, 37.5, 75, 75, 75 kVAR

Length Width Height Weight


60” 48” 72” 3,371 lbs.
152.4 cm 121.9 cm 182.9 cm 1,529.1 kg

R450
450 kVAR Inductive Load Bank
The R450 portable inductive load bank provides
loads which can be used to obtain a lagging power
factor. These units correspond to 750KVA loads,
at 0.8 power factor.
Each load bank is designed and built with
a 3.75 kVAR load resolution. The R450 has
450 kVAR capacity. 600 VAC also available.

kVAR Voltage Load Step Resolution


450 kVAR 240/480 VAC 3.75, 7.5, 7.5, 18.75, 37.5, 75, 75, 75, 75, 75 kVAR

Length Width Height Weight


60” 48” 72” 3,371 lbs.
152.4 cm 121.9 cm 182.9 cm 1,529.1 kg

26
inductive /capacitive

K841B
750 & 1125 kVAR Reactive Load Bank
• Load step resolution sized to match resistive
load bank steps to obtain 0.8 PF
• Suitable for indoor or outdoor operation
• Designed for continuous operation
• Non-saturating single-phase and 3-phase
iron core reactors
• 750 and 1125 kVAR models

kVAR Voltage Frequency Load Step Resolution


750 240/480 50/60 Hz 37.5, 37.5, 75, 75, 150, 375

1125 kVAR 480 50/60 Hz 3.75, 7.5, 7.5, 18.75, 37.5, 37.5, 75, 187.5, 375, 375 kVAR

Length Width Height Weight


114” 76” 58” 8,500 lbs.
289.6 cm 193 cm 147 cm 3,863.6 kg

CR2000 KVARC
2000 kVARC Capacitive Load Bank
The CR2000 capacitive load bank is used with
a resitive load bank to create a leading power
factor. It can also be used for power factor
correction.
The CR2000 is an outdoor unit designed to
provide 2000 kVARC capacitive.

Total Load kVARC Voltage Load Step Resolution kVARC


2000 480 V, 3-phase, 60 Hz 50,50,100,100,100,200,200,200,500,500
Length Width Height Weight
180” 70.5” 90.5” 6,300 lbs.
457.2 cm 179.1 cm 229.9 cm 2,857.6 kg

27
inductive /capacitive

CR500 KVARC
500 kVARC Capacitive Load Bank
The CR500 kVARC capacitive load
bank is used with a resistive load bank
to create a leading power factor.
This is an outdoor unit designed to provide
500 kVARC capacitive.
Great for meeting that new tough
commissioning specification in a
safe and reliable way.

kVARC Voltage Frequency Load Step Resolution


500 kVARC 480 VAC 60 Hz 50, 50, 100,100,100,100

Length Width Height Weight


30” 83” 89” 1,942 lbs.
76 cm 210.8 cm 226.1 cm 880.9 kg

R378
378.75 KVAR Reactive Load Bank

• Portable, for load testing at multiple sites


• Compact, easy to transport and operate
• 387.75 KVAR @ 240/480V, 3Ø
• 284.06 KVAR @ 208/416V, 3Ø
• Convenient operator controls

kVAR Voltage Frequency Load Step Resolution


378.75 KVAR 240/480 VAC 60 Hz 3.75, 7.5, 15.0, 15.0, 37.5, 75.0, 75.0, 75.0, 75.0 KVAR
284.06 KVAR 208/416 VAC 60 Hz 2.81, 5.63, 11.3, 11.3, 28.1, 56.3, 56.3, 56.3, 56.3 KVAR

Length Width Height Weight


80” 54” 61” 5,000 lbs.
203.2 cm 137.2 cm 154.9 cm 2,268 kg

28
DC & ELECTRONIC

DC RESISTIVE
K492 150 Amp 26/52 DC
T242 220 Amp 24/48 DC
L29-300 Amp 28 DC
L42-500 Amp 24/36/48 DC
L48-500 Amp 48 DC
K576 500 Amp 52 DC
K571 1000 Amp 28/52 DC
L121-250-60 250Amp 60/120 DC
CR600 600 kW 300/600 DC
CR1000 600 kW 500/1000 DC
K974A 375/750 DC
ELECTRONIC LOADS
RBL 232 150A 800W 0-50 DC
RBL 488 300A 2000W 0-400 DC
RBL 488 600A 4000W 0-600 DC
XBL 200A, 6000 W 0-600 DC
XBL 200A, 4000 W 0-600 DC
XBL 600A, 4000 W 0-100 DC
WCL 488 1000A
0-400 DC
12000W & Rack
WCS 488 1000A 12000W 0-400 DC
TORKEL 860 110 Amp 12 - 480 VDC DC
TEST SETS
HC-2 High Current Test Set

TORKEL CR600 L-121

29
dc & electronic

K492
150 Amp DC Resistive Load Bank
• Flexible and simple operation
• Compact, portable, lightweight
• Easy to read meters
• Over-temperature protected—removes
loads if overheating occurs
• Master load control switch allows for
instant application or removal of loads

Total Amps Voltage Load Step Resolution Amps


150 26/52 1, 2, 2, 5, 10, 10, 20, 20, 20, 20, 20, 20

Length Width Height Weight / Ship


18” 11” 13” 30 lbs. / 75 lbs.
45.7 cm 28 cm 33 cm 15.9 kg / 34 kg

T242
24/48 VDC, 200 Amp DC Load Bank
The T242 load bank is designed to provide convenient,
easily adjustable, low voltage DC load capability. The load
bank is furnished in a portable cabinet and is a forced
convection cooled load bank designed to operate from the
DC test source.
• Load can be adjusted from 0–220 amps
• Portable—can be shipped anywhere
in North America or internationally

Total Amps Voltage Load Step Resolution Amps


1–220 24/48 VDC 1, 2, 2, 5, 10, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20

Length Width Height Weight / Ship


22” 19” 26” 101 lbs. / 178 lbs.
55.9 cm 48.3 cm 66 cm 45.8 kg / 80.7 kg

30
dc & electronic

L121
250 Amp DC Electronic Load Controller

• 120 Volt portable unit


• Load can be adjusted from 0–250 amps
• Capable of 90–130 VDC
• Portable: can be shipped overnight anywhere
in North America or Internationally
• Shown right: the L121 in its shipping case
with cables

Total Amps Voltage Load Step Resolution kW


250 amps 120 VDC 125 amp fixed step; 0–125 amp adjustable step

Length Width Height Weight / Ship


22” 9” 12” 46 lbs. / 90 lbs.
55.9 cm 22.9 cm 30.5 cm 20.9 kg / 40.8 kg

L29
300 Amp Portable Load Bank
The L29 load bank is designed to provide
a temporary load for field servicing and
testing 28 volt ground power units. It is
air-cooled and completely self-contained.
There is a 300A continuous load. A 2000 amp
or 1400 amp load can be selected that
decreases to 0 amps in 35 seconds to simulate
an engine start.

Total Amps Voltage Load Step Resolution kW


300 continuous 28 VDC 2000 amps / 1400 amps (variable Amp)
Length Width Height Weight
22” 8” 12” 46 lbs.
55.9 cm 20.3 cm 30.5cm 20.9 kg

31
dc & electronic

L42
500 Amp DC Load Bank

The L42 load bank is designed to provide a


temporary load for field servicing and testing 24,
36 and 48 volt DC batteries and power supplies.
The L42 is air-cooled and completely self-contained.
The load can be adjusted from 0-500 amps at
48 VDC and 24 VDC. At 36 VDC the load can be
adjusted from 0-375 amps.
*(Note: @36 VDC only capable of 375 amps or 75%)

Total Amps Voltage Load Step Resolution Amps


500 Amps 24/36*/48 VDC 100, 100, 200 Amp fixed steps; 0–100 Amp adjustable

Length Width Height Weight


22” 8” 11” 49 lbs.
55.9 cm 20.3 cm 28 cm 22.3 kg

L48
500 Amp DC Load Bank
The L48 load bank is designed to
provide a temporary load for field
servicing and testing 48 volt DC
batteries and power supplies. The
L48 is air-cooled and completely self-
contained. The load can be adjusted
from 0-500 amps at 48 VDC

Total Amps Voltage Load Step Resolution Amps


0–500 48 VDC 100, 100, 200 Amp fixed load steps, 0–100 adjustable

Length Width Height Weight / Ship


14” 8” 22” 44 lbs. / 84 lbs.
35.6 cm 20.3 cm 55.9 cm 20 kg / 38 kg

32
dc & electronic

TORKEL 860
Battery Load Units
• Unit adjusts the load currents in the
test parameters per IEEE test standard
• User adjustable alarm and shutdown points to
avoid excessive discharge
• Easily save results to a PC for analysis, report
generation and storage
• Can be used in conjunction with other ComRent®
DC load banks
• Comes with 25’ lead sets

Max Amps Voltage Max. power Power supply voltage


110 A 10 - 480 V DC 15 kW 100 – 240 V AC, 50/60 Hz

Length Width Height Weight / Ship


27.6” 8.3” 13.9” 52 lbs. / 94 lbs.
70 cm 21 cm 35.3 cm 23.6 kg / 42.7 kg

K576
500 Amp Portable DC Load Bank
• Lightweight construction
• Durable load elements
• Portable, with lifting handles
• 52 Volt DC operation
• No “cool-down” period
• Load step toggle switches for load control

Total Load kW Voltage Load Step Resolution Amps


0–500 52 VDC 100, 100, 200 Amp fixed load steps, 0–100 adjustable

Length Width Height Weight / Ship


28” 22” 28” 162 lbs. / 312 lbs.
71.1 cm 55.9 cm 71.1 cm 73.5 kg / 141.5 kg

33
dc & electronic

K571
1000 Amp DC Load Bank, 28 & 52 VDC
The K571 load bank is a portable, self-contained unit
for electrically loading and testing 28 VDC generators.
Notable features include:
• Portable—with casters, for multiple site load testing
• Rugged aluminized steel enclosure
• Terminal board connectors are provided for metering

Total Amps Voltage Load Step Resolution


1,000 28 VDC 5, 10, 10, 25, 50, 100, 100, 200, 500
1,000 52 VDC 50, 50, 100, 100, 100, 200, 200, 200

Length Width Height Weight / Ship


34” 23” 63” 308 lbs. / 462 lbs.
86.4 cm 58.4 cm 160 cm 139.7 kg / 209.6 kg

CR600 / CR1000
High Capacity Portable DC Load Bank
• 300/600 VDC model
• 500/1000 VDC model
• Easy operator controls and digital metering
• Portable—for multiple site load testing
• Rugged aluminized steel enclosure with casters
• Unit requires external 480 VAC control power

Total Load kW Voltage Load Step Resolution


300 kW 300 VDC .5, 1, 1, 2.5, 5, 10, 10, 30, 60, 60, 120 kW
600 kW 600 VDC 1, 2, 2, 5, 10, 20, 20, 60, 120, 120, 240 kW
300 kW 500 VDC .5, 1, 1, 2.5, 5, 10, 10, 30, 60, 60, 120 kW
600 kW 1000 VDC 1, .2, 2, 5, 10, 20, 20, 60, 120, 120, 240 kW

Length Width Height Weight / Ship


61” 33” 75” 1,108 lbs. / 1,908 lbs
154.9 cm 83.8 cm 190.5 cm 502.58 kg / 865.5 kg

34
dc & electronic

RBL488
Electronic Load Bank, up to 600 VDC, 200A, 4 kW
Rental Units available include:
• 2000 Watt (19”W x 5.25”H x 22”D)
• 4000 Watt (19”W x 8.75”H x 22”D)
• Operation below 0.5V at 1000 amps
• Easily test with constant current, constant kW, and
constant resistance features
• Ratings from 0-100, 0 - 400V, 0-600 amps, up to
4000 watts in a single unit, paralleled capacity of
up to 8, 16 or 20 kW

Length Width Height Weight


40” 30” 16” 142 lbs.
101.6 cm 76.2 cm 40.6 cm 64.1 kg

XBL SERIES
Electronic Load Bank: up to 6000 watts, 600 VDC

• Test constant current, resistance, power


and voltage operation modes
• 16-bit digital control, offering excellent
accuracy and performance
• Remote-controllable monitoring via
Ethernet (TCP), Telnet and online
• High-speed programmable slew rate
• Closed-case calibration, minimizes downtime

Volts Amps Watts


600 200 4000
100 600 4000
400 200 4000
1000 600 6000

Length Width Height Weight


22” 19” 10.5” 112 lbs.
58.9 cm 48.3 cm 26.7 cm 50.8 kg

35
dc & electronic

WCL488
Water Cooled Electronic Loads—Master 12 kW

• A complete 36 kW system only 62’’ tall (shown)*


• Synchronized paralleling creates larger systems
controlled as a single unit
• Automated flow regulation to prevent condensation
• Modular design using standard building blocks
• Low water flow (3gpm @ 10° C / 12 kW)
• Constant current, power, voltage and resistance modes
• Self-configuring based on the number of slave
load banks in use
• Range switching for increased resolution and accuracy

(Including Rack) Length Width Height Weight


27” 34” 64” 608 lbs.
68.6 cm 86.4 cm 161.3 cm 275.8 kg

The WCL488 water cooled


electronic load 12 kW Master unit.

36
dc & electronic

K974A
High Capcity DC Load Bank
• 375/750 VDC - 2300 kW
• Unit provides DC resistive loading up to 6133 amps
@ 375 VDC and 3066 amps @ 750 VDC for a total
of 2300 kW @375/750
• Easy Operator control and digital metering
• Unit requires external 480 VAC control power

Volts Amps Load Step Resolution


375 6133 5,10,25,50,100,100,200,200,400,400,400 kW
750 3066 5,10,25,50,100,100,200,200,400,400,400 kW

Length Width Height Weight


95.38” 83.25” 93.12” 3,600 lbs.
242.3 cm 211.5 cm 236.5 cm 1,633 kg

37
MEDIUM VOLTAGE

AC RESISTIVE
CR922 A&B Units 4160/13800 AC

CR922 I 3MW/5MW 3300/6600 & 11500 AC

REACTIVE/INDUCTIVE
CR3750 MV 3750 kVAR 4160-14400 AC

CR922 units
38
medium voltage

CR922A
Medium Voltage
Resistive
5 MW Load Bank
ComRent®’s CR922 A
is a custom engineered
load bank designed
to meet the testing
requirements of medium
voltage generators at a
power factor of 1.0

Product Details Great for Testing up


● The CR922 A load bank is an outdoor unit designed for to 100 MW
portable use to specific test sites. Once on site, load bank
easily off-loads from truck using telescoping leg extensions
Medium-Voltage Generators
and struts.
Substations
● The CR922 A load bank is designed to absorb a balanced
Wind Farms
resistive load at a unity power factor. The total load
capacity of the load bank is 5 MW, 13,800V, 3-phase, 60 Ship Engines
Hz and 4 MW, 4160V, 3-phase, 60 Hz. Unit will operate at
Medium-Voltage Switchgear
lower voltages with standard voltage derating.

● The frame is fabricated using heavy gauge hot-rolled


steel, welded together, making a rigid weatherproof
structure. Thermal conditions of -40 F to +120 F.
Dimensions
● The CR922 A operates from an external 480V, 3-phase, Length (790 cm) 311”
60 Hz power source. The CR922 A requires 180 amps per
Width (358.1 cm) 141”
unit; two CR922 A load banks can be powered from one
400 amp source. Height (416.6 cm) 164”
Wt. (7484.2 kg) 16,500 lbs.
● N + 1 Manual and Remote control system.

Total Load MW Voltage Load Step Resolution kW


5 13,800 VAC, 60 Hz, 3-phase 500, 1000, 1500, and 2000 kW
4 4160 VAC, 60 Hz, 3-phase 400, 800, 1200, and 1600 kW

39
medium voltage

CR3750
3750 kVAR 5/15 kV Reactive Load Bank
• Easy operator controls and digital
metering that are N + 1
• Remote operation and monitoring
• Portable, for multiple site load testing
• Rugged 20’ ISO enclosure

Product Details Great for Testing


● The CR3750 MV is ideal for tests requiring a power factor
of 0.8 at 5 and 15 kV class voltages. The reactors are Turbines
housed in an 20’ ISO Container equipped with a fused Generators
disconnect, forced ventilation, operator control station
Switchgear
manual with metering, and a networked capable PLC with
remote touch screen, in a small but rugged protective Utility Grids
case provides N + 1 redundancy on HMI. Substations

● The CR3750 MV reactive load bank is designed to be


used in parallel with the CR922 resistive load bank to
achieve a 0.8 power factor load.
Dimensions
Length (609.6 cm) 240”
● Rugged designed iron core reactors, utilizing features from
all severe duty and transport applications. Temperature Width (243.8 cm) 96”
rating 130º C rises, with internal thermal monitoring on Height (256.5 cm) 101”
the center phase/core. A re-connectable tap board is
integrated with each reactor. Wt. (13,127 kg) 28,940 lbs.

● Every ComRent® load bank is built to enable customers


to successfully complete their testing, on time and with-
in budget.

● Capable of load testing from 4,160 VAC - 14,400 VAC. All


voltages 100% except , 4,160 is @ 80%.

Total Load kVAR Voltage Load Step Resolution kVAR


3000 4,160 300, 600, 900, 1200 kVAR
3750 13.8 kV 375, 750, 1150, 1500 kVAR

40
medium voltage

CR922 I
Medium Voltage Resistive 5 MW
Load Bank
ComRent®’s CR922 I is a custom
engineered load bank designed to meet
the testing requirements of medium
voltage generators at a power factor
of 1.0

Product Details Great for Testing up


● The CR922 I load bank is an outdoor unit designed for to 5MW
portable use to specific test sites.
Medium-Voltage Generators
● The CR922 I load bank is designed to absorb a balanced Substations
resistive load at a unity power factor. The total load
capacity of the load bank is 5 MW, 11,500V, 3-phase, 50 Wind Farms
Hz and 3 MW, 3300V, 3-phase, 50 Hz. Unit will operate at Ship Engines
lower voltages with standard voltage derating.
Medium-Voltage Switchgear
● The frame is fabricated using heavy gauge hot-rolled
steel, welded together, making a rigid weatherproof struc-
ture. Thermal conditions of -40 F to +120 F.
Dimensions
● The CR922 I operates from an external 480V, 3-phase,
50 Hz power source. The CR922 I requires 180 amps per Length (1,219 cm) 480”
unit; two CR922 I load banks can be powered from one Width (243.84 cm) 96”
400 amp source.
Height (259.1 cm) 102”
Wt. (19.853.7 kg) 43,770 lbs.

Total Load MW Voltage Load Step Resolution kW


5 11,500 VAC, 50 Hz, 3-phase 500, 1000, 1500, and 2000 kW
5 6600 VAC, 50 Hz, 3-phase 500, 1000, 1500, and 2000 kW
3 3300 VAC, 50Hz, 3-phase 500, 1000, and1500 kW

41
POWER
DISTRIBUTION

TRANSFORMERS
750 kVA 13.8 kV x 480 AC
2500/3500 kVA 2.4, 4.16/13.8kV x 480/600 AC
2500 kVA 2.4, 4.16/13.8 kV x 480 AC
4000 kVA 480/600 AC
4000/5000 kVA 208 x 240 x 480/600 AC
5500/6500 kVA 480 x 600 x 690 AC
5000/7000 kVA 2.4, 4.16/13.8 kV x 480 AC
SWITCHGEAR
5/15 kV Fused Disconnect (1) 5/15 kV – 720A AC
5/15 kV Fused Disconnect (3) 5/15 kV – 720A AC
5/15 kV Fused Disconnect (6) 5/15 kV – 720A AC
5/15 kV Circuit Breakers 3000A AC
600V Circuit Breaker 4000A AC
PANEL BOARDS/SWITCHBOARDS
I-Line Panel 600V 1200A AC

7000kVA
Transformers
on site

42
power distribution

750 KVA TRANSFORMER


750 kVA / 13.8 kV —480 V

ComRent® International, LLC’s new 750 kVA / 13.8 kV


480 Volt, Delta/Wye-configured dry-type transformer
has a small footprint and are both rugged and easy to
transport. The 750 kVA transformer has a NEMA 3R
type enclosure, access on both sides of the unit, and
has both forklift pockets and lifting eyes. Has variable
primaries: 13800, 13110, 13455, 13800,14145, 14490.

Conductor Phase Frequency Type Rise Class H


Aluminum 3 60 Hz AA 150o C 220o C Ins
Primary Primary Amps Bil—60 Secondary Secondary Amps Bil—10
13,800 Delta 31 kVA 750 480/277 Wye 902 kVA 750
Approximate impedance Taps primary
5.0% + 2 x 2.5%

Length Width Height Weight


123” 45” 90” 7,400 lbs.
312.4 cm 114.3 cm 228.6 cm 3,356.6 kg

TRANSFORMER
5/15kV / 2500 / 3125 / 3500 kVA
• Wye—Wye
• Delta—Wye
• Input Voltage: 2400–14400
• Output voltage: 480 VAC and 480/600 VAC
• 50 and 60 Hz voltage taps

Length Width Height Weight


120” 81” 91” 18,000 lbs.
304.8 cm 205.7 cm 231 cm 8,164.6 kg

43
power distribution

4000 KVA TRANSFORMER


4000 kVA / 600-480 VAC
ComRent® International’s new 4000 kVA/ 600-480VAC
Wye-configured dry-type transformer has a small
footprint and is both rugged and easy to transport.

Conductor Phase Frequency Type Rise Class H


Aluminum 3 60 Hz AA 150o C 220o C Ins
Primary Primary Amps Bil—60 Secondary Secondary Amps Bil—10
600 Y 3849 kVA 4000 480 Y 4811 kVA 4000
Approximate impedance Taps primary
+ 0.5% None

Length Width Height Weight


123” 45” 80” 7,900 lbs.
312.4 cm 114.3 cm 203.2 cm 3,583.4 kg

TRANSFORMER
600:480 VAC—4000/5000 kVA

• Multi-Tap configuration, dry type autotransformer


• 50/60 Hz core steel
• Input voltages: 600 (60 Hz)
• Output voltage: 480 (60 Hz)

kVA Voltage Taps 50 Hz Voltage Taps 60 Hz Amps 50 Hz Amps 60 Hz


4000/5000 480Y/277 600Y/346 4811/6014 4811/6014
4000/5000 380Y/220 480Y/277 4811/6014 4811/6014
2000 198Y/110 240Y/138 4811/6014 4811/6014
2000 173Y/100 208Y/120 5551/6980 5551/6940

Length Width Height Weight


118.5” 84” 91” 7,900 lbs.
301 cm 213.36 cm 231.1 cm 3,583.4 kg

44
power distribution

TRANSFORMER
5/15 kV—5000/6000/7000 kVA
• Multi-tap configuration
• Wye—Wye
• Delta—Wye
• Input voltages: 2400/14400 VAC
• Output voltages: 480 VAC
• 50 and 60 Hz voltage taps

Length Width Height Weight


140” 95” 94” 30,000 lbs.
355.6 cm 241.3 cm 238.76 cm 13,607.8 kg

Voltage Taps
2400 Delta 4160GRDY/2400
8320 Delta 14400GRDY/8320
7970 Delta 13800GRDY/7970
7620 Delta 13200GRDY/7620
7200 Delta 12470GRDY/7200
6640 Delta 11,000 or 11500GRDY/6640

5/15 kV FUSED DISCONNECTS


Versatile Vacuum Type “CM” Load Interrupter
Our 5/15 kV fused disconnects are excellent for
medium voltage load bank tests, generators, or
temporary power generation and distribution.
• (3) Modules 600 amp capacity
• (6) Modules 1200 amp capacity
• 150 amp frame expulsion fuses
• 400 amp frame expulsion fuses
• Max amps per module: 720 amps (fused)

Length Width Height Weight


4’3” 10’7” 8’2” 27,000 lbs.
129.5 cm 322.6 cm 248.9 cm 12,247 kg

45
power distribution

MULTI-PANEL
1200 Amp I-Line Panelboard System
The I-Line Panelboard system is a flexible power distribution
system that allows you to add and subtract circuit breakers in
the field to fit your particular application without a great deal of
difficulty. A screwdriver is all that is required to mount a 15
amp—800 amp circuit breaker. The circuit breakers ratchet
firmly onto the I-Line bus stack, and then captive retaining
screws secure the circuit breaker to the back panel.

Power Input Power Outlets Input Cable

Hardware via Circuit


3 Sets - 400 amp, 480V 3Ø, Cam Type Male Cam-Type
Breaker or Cam-type female
Length Width Height Weight
51” 38” 87” 524 lbs.
129.5 cm 96.5 cm 221 cm 237.7 kg

TRANSFORMER
5500/6500 kVA
• Multi-tap configuration
• Dry Type
• Operating Voltages: 690:600:480 (60Hz)
• 50 and 60 Hz voltage taps
• Can perform at 480 to 600, 600 to 690,
or 480 to 690

Length Width Height Weight


118” 84” 91” 13,900 lbs.
299.7 cm 213.4 cm 231 cm 6,304.9 kg

VOLTS AMPS
690Y/398 4602/5439

600Y/346 5292/6255

46
power distribution

3000 AMP MVCB + FUSED


DISCONNECTS
Excellent for medium voltage load bank
tests, generators, or temporary power
generation and distribution.
• Multiple Modules of 600 Amp Fused Air Brake
Switches
• Meets ANSI, IEEE, and NEMA standards
• 3,000 amp breaker
• 351S Relay System
• Combined Current & Potential Transformer

Length Width Height Weight


319” 50” 110” 14,000 lbs.
810.3 cm 127 cm 279.4 cm 6,350 kg

47
CABLES

CABLES
4/0 Cam 2 kV 405 Amps W
1/0 Cam 2 kV 260 Amps W
1/0 Cable Extensions 50’ 2 kV 260 Amps W
2/0 35 kV 300 Amps SH
#4 Ground 2 kV 149 Amps W
15KV Voltloc M.V. 2/0 & 500MCM 300 / 685 Amps SH
Pigtails, Adapters 4/0 2KV 405 Amps
Pigtails, Adapters 1/0 2KV 250 Amps
Cam three ways & Adapters 4/0
Power Cords 50’ / 100’
Cable Winder Machine 4/0 or 1/0 Cables W

CABLE ADAPTERS
Multi-taps Insulated 4/0 x 1/0, 4 barrel
Splitters 1/0 to 2 x #2
Lugs

CABLE ROLL-OUT / ROLL-UP


Up to 12 cables
13-24 cables Call for more details about our
roll-out and roll-up services
25 – 60 cables 888-881-7118
60+ cables

48
power cables

VOLTLOC®
Medium Voltage Power Cable System

• Adapter for indoor / outdoor copper


bus, 200 load break elbow, and
200/600 amp dead break elbow
• Pre-terminated and tested to save you
time and labor
• 15 kV Class, 100% type SH EPR Insulation
• Single-core flex stranded 2/0 (300 amp)
and 500 MCM (695 amp)
• Copper braided shield; Rubber jacket C.P.E.
• Portable safe load bank cable system

Cable Construction Great for Testing


Portable Substations
Temporary Generator
Switchgear
Temporary MV Feeders
Load Bank Testing

Available Lengths
50’ and 100’
Cable system can be set-up in
portable segments/ lengths to
1000’ or more
Pigtails are 15’

49
power cables

CAMLOC CABLES
2000 V UL Listed 90oC, 1/0 and 4/0

• Premium-grade 90° EPDM insulation


• Cable reinforced with an open polyester
braid applied between the insulation and
jacket for mechanical strength
• 1/0 cable rated at 265 amps-in free air
• 4/0 cable rated 405 amps-in free air
• PVC jacket
• Designed to withstand severe
environmental conditions. Meets or
exceeds flame test requirements of MSHA
and UL
• Available in 50’ lengths

50
power cables

35 kV CABLES
Type SH Termed Power Cabling System

• 35 kV Class, 100% type SH EPR Insulation


• Ultra flexible style cable that allows for remote
installations and testing
• Continuous conductor temperature 90° C
• Cables are pre-terminated with compression lugs and
Raychem stress cones
• Jacket - CPE meeting ICEA S-75-381/NEMA WC58
• Portable and rugged cable design can be used in
extreme conditions
• Available Crimp Lugs or Terminals: CLND 3/0 12-134

Great for Testing


Substations
Utility Transformers
High Voltage Utility Systems
Load Bank Testing

Available Lengths
100’ 200’ and 300’

51
ACCESSORIES

UV AND CORONA DEVICES


OFIL Corona Camera UV and Corona detection camera

BATTERY ANALYZER
Midtronics
Midtronics CTU-6000 Ultra 0-20000Ω

52
test and measurement equipment

CORONA CAMERA
DayCor® Superb - Detecting your future voltage failures

• Pinpoints and visualizes the corona location


and detects electrical leakage
• Excellent for daytime work
• Provides you with early warnings of
potential equipment failures
• Helps you prioritize your maintenance
tasks by determining the health of your
mission critical power system components

Product Details
• The DayCor® Superb has an outstanding UV
sensitivity of 3x10-18 watt/cm2 which enables the
detection and display of corona emission as weak Great for Testing
as 1.5 pC at a distance of 26’. Predictive maintenance
• Equipped with built-in memory card storage, the tasks in OH transmission
lines, substations, and for
DayCor® Superb records high resolution video clips
other non-foot patrol functions.
and still images with optional text annotation and
GPS data. Recorded data can be viewed at any time
through the playback button.
Dimensions
• The integrated reflective, high-brightness, adjustable
color 5” LCD viewer is designed with safety in mind Length (23 cm) 9.1”
and is large enough for a team to view. Width (18 cm) 7.1”

• The Daycor® Superb features straight forward, Height (15 cm) 5.9”
intuitive controls with on-screen indication of Weight (3.6 kg) 8 lbs.
selected functions.
• Ergonomic form factor designed to accommodate
long continuous use.

Coronal discharge
as seen with the
Corona Camera

53
DAYCOR® TECHNICAL SPECIFICATIONS
UV - Optical Properties
Minimum UV Sensitivity 3x10-18 watt/cm2
Minimum Discharge Detection 1.5 pC @ 8m (26’)
Minimum RIV Detection 15dBm(RIV)@1MHz
Field of View (H x V) 5” x 3.5”
Detector Lifespan No degradation
Full auto-focus for UV and visible channels
Focus
Simultaneous manual focus adjustment for both channels
Focus Distance 0.5m (1.6’) – infinity (with optional close-up lenses)
Digital UV / Combined Zoom X2 and X4
Visible - Optical Properties
UV/Visible Overlay Accuracy Better than 1 miliradian
Minimum Visible Light Sensitivity 0.1 Lux
Video Standard Full PAL or NTSC standards
25 optical x 12 digital
Rapid Visible Zoom Max visible zoom reached within 1sec on button push
Return to normal value within 1sec on button release
Display
Type Integral color LCD, adjustable
Brightness 450 cd/m2 reflective, adjustable
Resolution 640 x 480 pixels, color, 5” display
Modes Combined (UV & Visible) UV only, Visible only
External Display Composite PAL or NTSC via BNC jack
Controls & Operation
Method Keyboard
Functions Activation One touch button
Rapid Zoom Continuous push button
System Status Indicator LCD shows low battery
Environmental
Storage and Operations Temp -20oC up to +550C
Internal Data Storage
Media ASF, WMV compatible
Video Format AVI
Storage Capacity Up to 2GB
Image Format JPEG
Playback Video & pictures
Power Source
Nominal Power Source 12V DC, 16 Watts
Rechargeable NiMH battery, 2.5+ hours continuous operation Universal AC/12V
Power Source
DC adapter

54
test and measurement equipement

CX™ MONITOR
Power Quality Monitor
The Cx Monitor has raised the bar for
systems power quality monitoring. It
offers advanced data collection, storage
and reporting capabilities. System
assessments and reporting have never
been faster or easier.

Smart Operations
Live-View™ & U-View™ software make it
possible to easily observe live data, similar to
a scope with high speed transient detection.

Advanced documentation and report writing


capabilities are at your fingertips. With an
open protocol platform, data can also be
Simple Set -up
transferred to your preferred program, such There is no real “set-up,” only 2 decisions to
as Microsoft Excel. be made:

Wi-Fi provides convenient downloads from 1. Decide logging increments— 1 second up


to 30 minutes.
multiple monitors – faster than Bluetooth
technologies. 2. Select connectivity—USB, Ethernet or Wi-Fi.

5 current channels ensure maximum data


acquisition.

Data is converted to binary transient files to


save memory and download time.

10 voltage channels eliminate the need for


cross triggers.

R-Sync™ is the application used for critical


timing monitoring. Real-time clock with
remote atomic time synchronization ensures
reporting within 1 millisecond of multiple
components.

Self-diagnosing calibration system.

Internal UPS for emergency backup.


AC flexible 3-phase current probe
All data is archived on Rx Monitoring Services’
Up to 6000 Amps
servers; never lose data again.

55
test and measurement equipement

CX™ TECHNICAL SPECIFICATIONS


Voltage Measurements Temperature
Channels 10 (internal) channels Range 0 – 122o Fahrenheit

Range 0–600 VRMS Resolution 0.02o Fahrenheit

Accuracy 0.5V Accuracy + 1o Fahrenheit

Transients 4,000V (peak to peak)


Humidity
Load disconnect @ 105% of selected
Analog Models
Current measurements full scale voltage
Range (IEEE) 0 – 105% of selected full scale
Channels 5 channels
Resolution
Range + 0 – 6,000ARMS 0.4% of selected full scale
(IEEE)
Accuracy 1 Amp
AC Current Probes
ACP 3,000
Frequency Measurements
Accuracy + 1% Reading (3kA)
Frequency 50, 60 Hz
Max Safe Voltage 1,000VRMS
Storage Data Storage 512MB – 2GB
Dynamic Range 100mA – 6,000A ACRMS
Expanded memory up to 10GB
Programmable amount of weeks up Linearity + 0.2% of Reading
Running Time
to 18 months
Frequency Range 10 Hz – 10 kHz

Phase Shift < 1o


Communication Protocols: ACP 6,000
USB 2.0 Host and Slave
Accuracy + 2.5% (6kA)
Ethernet 10/100 TCP/IP
Max Safe Voltage 1,000VRMS
FTP, HTTP, HTTPS, SMS
Dynamic Range 100mA – 6,000A ACRMS
Wi-Fi Wireless options available
Linearity + 0.2% of Reading

Frequency Range 10 Hz – 10 kHz

Phase Shift < 1o

56
test and measurement equipement

CELLTRON ULTRA
Universal Stationary Battery Analyzer
• Tests individual lead acid cells or monoblocs
( up to 16 Volts) in any common configuration
• 1.5—20.0 Volts DC
• 32 megabyte card stores data up to 500
battery strings/locations
• Versatile features allow for the measurement of
AC and DC voltage and current
• Scope mode displays AC ripple current and more

Length Width Height Weight / Ship


11” 4” 3” 2.6 lbs. / 24 lbs.
280 mm 105 mm 80 mm 1.2 kg / 10.9 kg

Technical Specifications
Model Power Requirements Internal swappable battery & charger
CTU-6000
Number LCD - FSTN
Tests individual lead acid cells or monoblocs 2.619 “ x 1.309”, 128 x 64 pixels, 40
Applications (up to 16 Volts) in any common Display
degree viewing angle, contrast ratio 8,
configuration, approximately 10-6000 Ah. Green LED backlight
Voltage 1.5 - 20.0 Volts DC Stainless-steel dome, polycarbonate
Keypad
Conductance 100 - 19,990 Siemens overlay, 1,000,000 actuations
Test Data 500 string locations of 480 Infra-red HP protocol, Infra-red,
Storage test results stored internally Data Transfer half-duplex IRDA protocol, RS-232
Accuracy + 2% across test range printer, Secure digital card
Voltmeter Environmental 0 to +40°C, 95% relative humidity,
5 mV Operating Range
Resolution non-condensing
USER PROGRAMMABLE FUNCTIONS Storage Temperature -20 to 82°C
Preset values for over 250 battery types OVER-VOLTAGE PROTECTION
Low voltage alarm setting Auto-reset disconnect
Low conductance warning Reverse Polarity Protected
Low conductance failure Acid resistant ABS plastic santo-
Housing Material
Test mode (push button/auto start) prene overmold
CONNECTORIZED TEST CABLE OPTIONS 11” x 4” x 3”
Analyzer Dimensions
280 mm x 105 mm x 80 mm
Dual contact clamps
19” x 15.5 “ x 7”
Dual contact probes Case Dimensions
485 mm x 395 mm x 180 mm
Custom cables by quotation Analyzer Weight 2.6 lbs.
Auto-calibration prior to every test,
Calibration Shipping Weight Approximately 11 lbs.
no future calibration required

57
TRANSPORT

TRAILERS FOR TRANSPORTATION


Single Axle
Two Axle
35’ Step Deck
40’ Step Deck
48’ Flat Bed
20’ Chassis
40’ Chassis with container

CABLE ROLL-OUT / ROLL-UP

Call for more details about our roll-out and roll-up services
888-881-7118

PORTABLE ROADWAY SYSTEMS


TrakMats® 44½” x 8’ x ½”

58
ComRent International Headquarters
10901 W 120th Ave, Suite 150
(888) 881-7118 • www.comrent.com

59

Вам также может понравиться