Subject: Proposal for Implementation of revised standard IS 651: 2007 for Glazed
Stoneware Pipes and Revised STI.
1) Clause 5.3 has been deleted since change in color is not relevant as it does not
effect quality of pipes.
2) Pipes of diameter upto 800 mm have been included . provisions of supply of pipes
in longer lengths has also been made .Tolerances on internal diameters ,length and
straightness have been modified ,keeping in view the current manufacturing
practices.
3) Pipes have been classified into three classes based on their crushing strength.
Additional sizes of the pipes have been introduced in terms of diameter.
4) Provisions have been made for joints by using rubber seal,as agreed between the
manufacturer and the buyer.
Consequent upon revision of IS 651:1992 to IS 651:2007 it has been decided to revise the
Scheme of Test and Inspection as per draft enclosed. We intend to implement revised
Standard IS 651:2007 and revised draft STI w.e.f 01/03/2008 . ROs /BOs Operating the
licences as per IS 651 are requested to send comments if any on revised Draft STI and
date of implementation for revised Standard.
Comments (if any) w.r.t Draft STI may please send to CMD III within 15 days
i.e latest by 30th Dec 2007.
(Nawal Kishore )
Scientist B (CMD-III)
Sc.F&H(CMD-III)
2. TEST RECORDS - All records of tests, inspection and calibration shall be kept
in suitable forms approved by the Bureau.
2.2 Copies of any records and other connected papers that may be required by the
Bureau shall be made available at any time on request.
4.1 MARKING - In addition each pipe and fitting shall be legibly impressed upon
it before firing with the following :
5.2 On the basis of tests and inspection, decision regarding conformity or otherwise
of the control unit to a given requirement shall be made.
5.2.1 All pipes/fitting shall be checked for General Quality (cl.5) & Glazing (cl.6) and
those not conforming to the requirements be rejected & segregated. In case, pipes/fittings
with belemishes as per cl.5.2 is being considered all such pipes shall be checked for Hyd.
Test separately.
5.2.2 HYDRAULIC TEST - All the sample pipes subjected to hydraulic test shall be
found satisfactory otherwise the control unit be rejected or each pipe/fitting be checked *
only those found conforming be considered as passing for purpose of Standard Mark.
5.2.3 ABSORPTION TEST - The mean and the range (difference between the highest
and the lowest value) of the test results obtained shall be calculated and (mean 0.6 range)
shall be less than or equal to the maximum limit specified in cl. 7.3 of specification. In
case of failure the control unit shall be considered unfit for application of Standard Mark.
5.2.4 Acid Resistance Test, Test for Alkali Resistance and Crushing Strength Test -
The samples from each control unit shall satisfy the requirements of the tests. If there is
any failure, the entire control unit shall be considered unfit for the application of Standard
Mark.
In respect of all other clauses of the specification the factory will maintain
appropriate control and checks to ensure that their product conforms to the various
requirements of this specification.
7 SAMPLES – The licensee shall supply, free of charge, the samples required in
accordance with the Bureau of Indian Standards (Certification) Regulations, 1988, as
subsequently amended, from the factory or godowns. The Bureau shall pay for the
samples taken by it from the open market.
10 RODUCTION DATA – The licensee shall send to BIS as per the enclosed
proforma-1 to be authenticated by a Chartered Accountant a statement of quantity
produced, marked and exported by him and the trade value thereof at the end of each
operative year of the licence.
Table 1………
IS 651:2007
GLAZED STONEWARE PIPES AND FITTINGS
TABLE 1 LEVELS OF CONTROL
(Para 5 of the Scheme of Testing and Inspection)
7.2 Hydraulic Test 7.2 -do- 5 % subject Each control (see also para 5.2.2 of
to a min. of unit this scheme)
10
7.3 Absorption Test 7.3 -do- 2 -do- (see also para 5.2.3 of
this scheme)
7.4 Test for Acid 7.4 -do- 2 -do- (see also para 5.2.4 of
Resistance this scheme)
7.5 Test for Alkali 7.5 -do- 2 -do- -do-
Resistance
7.6 Crushing strength 7.6 -do- 2 -do- -do-
test
Section A & B : Dimensions and other requirements.
a) Internal 10,17 -do- 5 % of the -do- i)Gauging would suffice
diameter of pipes pipes/fitting
& fittings s produced ii) None of the
b) Length and 12 -do- subject to a pipes/fittings so checked
straightness of minimum for dimensions shall be
barrels or straight of 10 pipes found defective. In case
and taper pipes any pipe/fittings is
c) Thickness of 11 -do- found-non-conforming
barrels, socket for any one or more
and bends dimensions all
d) Dimensions of 13 -do- pipes/fittings in the
tapers, bends and control unit shall be
13 junctions. checked.
e) Taper and 14, 18 -do-
depth of socket
f) Grooving 15, 19 -do-
NOTE : Samples of pipe/fittings required for tests against 7.3 to 7.6 shall be selected
from those pipes already examined for dimensions and found satisfactory.
FORM NO. 1 – HYDRAULIC TEST
Date Control Unit Size of Control No. of Samples No. of Samples Remarks
Unit Drawn which Passed
the Tests
Date Control Size of Sample Pipes/Fittings Thickness Mass of Mass after Increase Percentage Remarks
Unit Control No. & Size of Dried Immersion in Mass Increase
Unit pipe/fittings Specimen