Академический Документы
Профессиональный Документы
Культура Документы
I) Proportioning of Footing
XC R XO
PULS1= 957.00
P1= 734.12 KN
X’
a'= 0.3 m
b'= 0.3 m
PULS2= 1580
P2= 1179.12 KN
a"= 0.4 m
b"= 0.4 m
Xc= 1.8 m
sall= 430 KN/m
2
R= 1913.23 KN
X'= 1.11 m
a= 2.52 m b’ b" b
b= 1.77 m
a’ a”
sact= 408.81 Ok
s= 735.86
Xo= 0.45
734.12 1179.12
2.6
735.86
700.81
110.38 0.85
478.31
Shear force diagram
623.74
77.64
8.28
Absolute Architects
June 2019
b) Determination of Footing Depth
fck= 25 Mpa
fck= 20
fcd= 11.33 Mpa
fctk= 1.55
fyk= 300 Mpa
fyd= 260.87
rmin= 0.0016667
fctd= 1.032 Mpa
Under Column 1
Vnet= 299.33 Kpa
Vup= 520.47 Kpa Ok
Under Column 2
Vnet= 488.99 Kpa
Vup= 693.96 Kpa Ok
C) Reinforcement
i) Direction X
MMax= 256.07 KNm
Mrd= 1321.92 KNm Ok
ρ= 0.00278
2
Asteel = 2253.50 mm Top reinforcement
Ø 14
S 120 mm
No. of bars 15 Use Ø 14 c/c 120
Cantilever Portion
MMax= 77.64 KNm
Mrd= 1321.92 KNm Ok
ρ= 0.00082
2
Asteel = 1350.00 mm Bottom reinforcement
Ø 12
S 150 mm
No. of bars 12 Use Ø 12 c/c 150
ii) Direction Y
Column 1
s1= 776.84 KN/m
2
M1 = 114.71 KNm
Mrd= 361.94 KNm Ok
ρ= 0.00466
2
Asteel = 1065.59 mm Bottom reinforcement
Ø 20
S 150.00 mm
No. of bars 4 Use Ø 20 c/c 150
Column 2
s2= 770.66 KN/m
2
M2 = 160.49 KNm
Mrd= 586.00 KNm Ok
ρ= 0.00399
2
Asteel = 1478.97 mm Bottom reinforcement
Ø 16
Absolute Architects
June 2019
S 110.00 mm
No. of bars 8 Use Ø 16 c/c 110
Nominal Reinforcement
Direction X
2
As min = 1350.00 mm Bottom reinforcement
Ø 12
S 150.00 mm
No. of bars 12 Use Ø 12 c/c 150
Direction Y
2
As min = 726.67 mm Top reinforcemnt
Ø 12
S 150.00 mm
No. of bars 7 Use Ø 12 c/c 150
Cantilever Portion
As min = 164.25
Ø 12
S 150.00
No. of bars 2 Bottom reinforcement Use Ø 12 c/c 150
D) Development Length
Direction X
ld = 1345.47 mm
Direction Y
ld = 1345.47 mm
Absolute Architects
June 2019
I) Proportioning of Footing
XC R XO
PULS1= 1119.00
P1= 853.93 KN
X’
a'= 0.35 m
b'= 0.35 m
PULS2= 1650
P2= 1233.22 KN
a"= 0.4 m
b"= 0.4 m
Xc= 1.5 m
sall= 430 KN/m
2
R= 2087.15 KN
X'= 0.89 m
a= 2.12 m b’ b" b
b= 2.29 m
a’ a”
sact= 412.48 Ok
s= 948.71
Xo= 0.33
853.93 1233.22
2.2
948.71
735.15
166.02 0.73
498.07
Shear force diagram
687.91
49.96
14.53
Absolute Architects
June 2019
b) Determination of Footing Depth
fck= 25 Mpa
fck= 20
fcd= 11.33 Mpa
fctk= 1.55
fyk= 300 Mpa
fyd= 260.87
rmin= 0.0016667
fctd= 1.032 Mpa
Under Column 1
Vnet= 400.25 Kpa
Vup= 542.16 Kpa Ok
Under Column 2
Vnet= 639.42 Kpa
Vup= 657.82 Kpa Ok
C) Reinforcement
i) Direction X
MMax= 234.88 KNm
Mrd= 1689.12 KNm Ok
ρ= 0.00198
2
Asteel = 2047.41 mm Top reinforcement
Ø 14
S 170 mm
No. of bars 14 Use Ø 14 c/c 170
Cantilever Portion
MMax= 49.96 KNm
Mrd= 1689.12 KNm Ok
ρ= 0.00041
2
Asteel = 1725.00 mm Bottom reinforcement
Ø 12
S 150 mm
No. of bars 16 Use Ø 12 c/c 150
ii) Direction Y
Column 1
s1= 645.70 KN/m
2
M1 = 176.47 KNm
Mrd= 396.41 KNm Ok
ρ= 0.00671
2
Asteel = 1681.32 mm Bottom reinforcement
Ø 20
S 100.00 mm
No. of bars 6 Use Ø 20 c/c 100
Column 2
s2= 630.80 KN/m
2
M2 = 241.95 KNm
Mrd= 586.00 KNm Ok
ρ= 0.00618
2
Asteel = 2290.13 mm Bottom reinforcement
Ø 20
Absolute Architects
June 2019
S 110.00 mm
No. of bars 8 Use Ø 20 c/c 110
Nominal Reinforcement
Direction X
2
As min = 1725.00 mm Bottom reinforcement
Ø 12
S 150.00 mm
No. of bars 16 Use Ø 12 c/c 150
Direction Y
2
As min = 490.50 mm Top reinforcemnt
Ø 12
S 150.00 mm
No. of bars 5 Use Ø 12 c/c 150
Cantilever Portion
As min = 73.00
Ø 12
S 150.00
No. of bars 1 Bottom reinforcement Use Ø 12 c/c 150
D) Development Length
Direction X
ld = 1345.47 mm
Direction Y
ld = 1345.47 mm
Absolute Architects