POWER CONTROL:

 Main turns on Power Supply. Power supply turns on low voltage signals
and PS ON is159 sent to the logic PCB.
 When Logic Board sees PS ON, it sends Vs ON command to the Power
Supply and stayson if no failures in the circuit are detected (1 second
delay).
 The LVDS Cable 10 Bit Digital Video information from the Main Board is
processed by the logic board. The LVDS receiver translates the video
data from the Main Board.
 The Logic Board produces the Set, Scan, & Sustain signals and send it
to the Y Board
 The Logic Board produces the Erase & Sustain Signals to the X-Board
 The Logic Board produces the Address Pulses to the Logic Buffer
Boards determining which cells to light. during the 10 sweeps of Scan
operation per frame.

OPERATION LED STATUS INDICATOR:


 Blinks once per second: When Normal Operation
 Blinks Slower than once per second:When a Circuit Error is Detected
due to a defective y or X Boards or Address Boards)