Вы находитесь на странице: 1из 1

KBR Technology

FLUID FLUID Houston, USA AIR FAILURE CODE PAGE: 5 OF 18


CODE UNITS O=OPEN C=CLOSED L=LOCKED JOB NO. H-202
L=LIQUID m³/h INSTRUMENT DATA SUMMARY SHEET TIGHT SHUTOFF CLIENT: Hindustan Petroleum Corporation Limited (HPCL)
S=STEAM kg/h Y = YES N = NO DOC NO. H202-CV-001
V=VAPOR, GAS kg/h CONTROL VALVES HANDWHEEL REV DATE
Y = YES N = NO 3 21-Jan-19
PLANT ATMOSPHERIC PRESSURE = 1.03 kg/cm²(Abs)

TAG NO. LINE SIZE FLOWING FLOWRATE INLET SIZING VAPOR MAX INLET S. G. CRITICAL VISC COMMENTS REV
inches FLUID MAX PRESS DIFF.PRESS PRESS DIFF. PRESS TEMP @ TEMP PRESS cP
FLOW LINE NORMAL kg/cm²(Ga.) kg/cm² kg/cm²(Abs) FOR °C Density kg/cm²(Abs) Cp/Cv
SHEET NO. SPEC MIN Z ACTUATOR @ TEMP VAPOR (k)
kg/cm² kg/m3 MW
FV-71302 6 L Solvent 128 52.4 4.2 19.77 206 0.4692 34.3 0.08 N N FO
504-11713 D9A 99 54.9 6.7 70.0 161 469.2 -
49 57.5 9.3 161
TV-71601 4 L Solvent 74 43.3 0.71 2.37 90 0.5889 34.3 0.17 N N FO
504-11716 D9A 51 47.9 0.35 58.0 63 588.9
25 51.2 0.07 63
FV-71701 10 L Therminol 72 532 8.0 0.70 5.00 0.7619 33.0 0.150 N N FC
504-11717 B1A 203 24.0 370 761.9 -
100

PV-71801B 6 L Solvent 175 41.4 39.6 26.83 51.5 180 0.4187 34.3 0.06 N N FC Downstream of Control valve: 100 % Vapor @ 69 deg C.
504-11719 D9A 418.7 7.5233 kg/m3, 0.008 cP, Cp/Cv 1.087, Z 0.922, MW 72.2

HV-71901A 16 L Solvent 1455 39.7 0.7 20.93 217 0.4525 34.3 0.07 N N FO HV-71901 A & HV-71901 B are reverse acting. 0
504-11719 D9A 1099 40.8 0.9 54 164 452.5 - Control valve min stop flow rate to be determined during detail engineering. 0
540 41.8 1.0 164 REMARK-1 0
HV-71901B 16 L Solvent 1479 40.1 1.1 26.75 220 0.4178 34.3 0.07 N N FC HV-71901 A & HV-71901 B are reverse acting. 0
504-11719 D9A 1190 41.1 1.2 54 180 417.8 - Control valve min stop flow rate to be determined during detail engineering. 0
586 42.1 1.3 180 REMARK-1 0
REMARKS:
1. PROVIDE MINIMUM STOP.

ROSE Technology is Proprietary Information of KBR


TO BE KEPT CONFIDENTIAL

Вам также может понравиться