Вы находитесь на странице: 1из 21

Beghelli

Available in 8 - 9PL - 11PL - 18 - 2x18 PROTECTION

24PL / W, SA (Maintained) and SE (Non


Maintained), 1- 3 hours versions, is able
to conduct autonomously (AT version) or
IP 65
D E G R E E

via the CU (CT-CTOC, CTS versions),Self


testing, periodic operational and full dura-
tion tests.
With the interface CTW the monitoring,
control and tests function can be run
via internet.
Reflector and diffuser developed
by Fiat Research Centre
Can be installed even
on flammable surfaces F
Power supply 230V (+10% / -6%)
Recharging time : 12 hours PROTECTION

Patented electronic circuit


“Granluce” range is equipped with
IP 65
D E G R E E

a special PCB allowing a very high


light output on emergency operation
A LED indicates operation and condition.
Possibility of enabling the emergency
function by a single command.
Self-extinguishing plastic (standard
EN 60598-1, UL94).
Fluorescent tube powered by
energy saving electronic ballast
(SA-Maintained versions).
Designed for installation with Ø16 and Ø20
PROTECTION
tubes, for suspended or electrified rail.

IP 65
D E G R E E

cd/1000 lm 626 8W cd/1000 lm 626 11W cd/1000 lm 626 24W


90° 90°
90° 90° 90° 90°

75° 40 75°
75° 50 75° 75° 50 75°

100 80 60° 100


60°
60° 60° 60° 60°

150 120 150

45° 45°
200 200 45°
45° 45° 160 45°

250 250
200
30° 15° 0° 15° 30° 30° 15° 0° 15° 30° 30° 15° 0° 15° 30°
C180 C270 C0 C90 C180 C270 C0 C90 C180 C270 C0 C90

32
Industrial Luce 626 AT- CT - CTOC - CTS - CTW

DIMENSIONS (mm)

W A B C
C

8W-9WPL 400 170 89


11PL-24W 400 170 89
B

A 18W-2x18W 400 170 89

PROVIDED WITH TO BE ORDERED SEPARATELY


• ADHESIVE LEGENDS • ADJUSTABLE BRACKET
• SUSPENSION HOOKS (ONLY FOR PL9PL)
• PG16-PG20 TUBE GLAND • PROTECTIVE GRILLE
• ADDITIONAL ADHESIVE LEGENDS

Ceiling or wall mounting with adjustable bracket ( to be order separately)

Suspended installation using chains Installation on an electrified rail Installation with Ø16 or Ø20mm tubes

Industrial Luce 626 high performance emergency “Granluce” series

AT G R A N L U C E NON MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
8 2098 GL626AT-8SE1P 1h 350 lm 100% 3VA Pb 6V 5Ah II 2.3
8 2100 GL626AT-8SE3P 3h 350 lm 55% 3VA Pb 6V 5Ah II 2.3
11PL 2102 GL626AT-11SE1P 1h 900 lm 90% 6VA Pb 6V 5Ah II 2.3
11PL 2104 GL626AT-11SE3P 3h 900 lm 40% 6VA Pb 6V 5Ah II 2.3
18 2110 GL626AT-18SE1P 1h 1150 lm 58% 5VA Pb 6V 5Ah II 2.3
18 2112 GL626AT-18SE3P 3h 1150 lm 25% 5VA Pb 6V 5Ah II 2.3
24PL 2106 GL626AT-24SE1P 1h 1800 lm 40% 6VA Pb 6V 5Ah II 2.3
24PL 2108 GL626AT-24SE3P 3h 1800 lm 19% 6VA Pb 6V 5Ah II 2.3

AT G R A N L U C E MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
8 2114 GL626AT-8SA1P 1h 350 lm 100% 25VA Pb 6V 5Ah II 2.3
8 2116 GL626AT-8SA3P 3h 350 lm 55% 25VA Pb 6V 5Ah II 2.3
18 2122 GL626AT-18SA1P 1h 1150 lm 58% 24VA Pb 6V 5Ah II 2.5
18 2124 GL626AT-18SA3P 3h 1150 lm 25% 24VA Pb 6V 5Ah II 2.5
24PL 2118 GL626AT-24SA1P 1h 1800 lm 40% 25VA Pb 6V 5Ah II 2.7
24PL 2120 GL626AT-24SA3P 3h 1800 lm 19% 25VA Pb 6V 5Ah II 2.7

33
Industrial Luce 626 high performance emergency “Granluce” series

CT Control unit - accessories PAG. 11 G R A N L U C E NON MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
18 2126 GL626CT-8SE1P 1h 350 lm 100% 3VA Pb 6V 5Ah II 2.3
18 2127 GL626CT-8SE3P 3h 350 lm 55% 3VA Pb 6V 5Ah II 2.3
11PL 2128 GL626CT-11SE1P 1h 900 lm 90% 6VA Pb 6V 5Ah II 2.3
11PL 2129 GL626CT-11SE3P 3h 900 lm 40% 6VA Pb 6V 5Ah II 2.3
18 2132 GL626CT-18SE1P 1h 1150 lm 58% 5VA Pb 6V 5Ah II 2.3
18 2133 GL626CT-18SE3P 3h 1150 lm 25% 5VA Pb 6V 5Ah II 2.3
24PL 2130 GL626CT-24SE1P 1h 1800 lm 40% 3VA Pb 6V 5Ah II 2.3
24PL 2131 GL626CT-24SE3P 3h 1800 lm 19% 3VA Pb 6V 5Ah II 2.3

CT Control unit - accessories PAG. 11 G R A N L U C E MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
8 2134 GL626CT-8SA1P 1h 350 lm 100% 25VA Pb 6V 5Ah II 2.3
8 2135 GL626CT-8SA3P 3h 350 lm 55% 25VA Pb 6V 5Ah II 2.3
18 2138 GL626CT-18SA1P 1h 1150 lm 58% 24VA Pb 6V 5Ah II 2.5
18 2139 GL626CT-18SA3P 3h 1150 lm 25% 24VA Pb 6V 5Ah II 2.5
24PL 2136 GL626CT-24SA1P 1h 1800 lm 40% 25VA Pb 6V 5Ah II 2.7
24PL 2137 GL626CT-24SA3P 3h 1800 lm 19% 25VA Pb 6V 5Ah II 2.7

CTOC Control unit - accessories PAG. 13 G R A N L U C E NON MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
8 2140 GL626CTOC-8SE1P 1h 350 lm 100% 3VA Pb 6V 5Ah II 2.3
8 2141 GL626CTOC-8SE3P 3h 350 lm 55% 3VA Pb 6V 5Ah II 2.3
11PL 2142 GL626CTOC-11SE1P 1h 900 lm 90% 6VA Pb 6V 5Ah II 2.3
11PL 2143 GL626CTOC-11SE3P 3h 900 lm 40% 6VA Pb 6V 5Ah II 2.3
18 2146 GL626CTOC-18SE1P 1h 1150 lm 58% 5VA Pb 6V 5Ah II 2.3
18 2147 GL626CTOC-18SE3P 3h 1150 lm 25% 5VA Pb 6V 5Ah II 2.3
24PL 2144 GL626CTOC-24SE1P 1h 1800 lm 40% 3VA Pb 6V 5Ah II 2.3
24PL 2145 GL626CTOC-24SE3P 3h 1800 lm 19% 3VA Pb 6V 5Ah II 2.3

CTOC Control unit - accessories PAG. 13 G R A N L U C E MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
8 2148 GL626CTOC-8SA1P 1h 350 lm 100% 25VA Pb 6V 5Ah II 2.3
8 2149 GL626CTOC-8SA3P 3h 350 lm 55% 25VA Pb 6V 5Ah II 2.3
18 2152 GL626CTOC-18SA1P 1h 1150 lm 58% 24VA Pb 6V 5Ah II 2.5
18 2153 GL626CTOC-18SA3P 3h 1150 lm 25% 24VA Pb 6V 5Ah II 2.5
24PL 2150 GL626CTOC-24SA1P 1h 1800 lm 40% 40VA Pb 6V 5Ah II 2.7
24PL 2151 GL626CTOC-24SA3P 1h 1800 lm 40% 40VA Pb 6V 5Ah II 2.7

34
Industrial Luce series

AT NON MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
8 2154 626AT-8SE5P 6h 350 lm 30% 3VA Pb 6V 5Ah II 2,3
9PL 2084 626AT-9SE3P 3h 600 lm 100% 6VA Pb 6V 5Ah II 2,3
11PL 2166 626AT-11SE5P 6h 900 lm 20% 6VA Pb 6V 5Ah II 2,3
18 2182 626AT-18SE3P 3h 1150 lm 25% 5VA Pb 6V 5Ah II 2,3
2 X18 2190 626AT-2x18SE1P 1h 2x1150 lm 45% 5VA Pb 6V 5Ah II 2,5
24PL 2170 626AT-24SE3P 3h 1800 lm 25% 3VA Pb 6V 5Ah II 2,3

AT MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
8 2156 626AT-8SA5P 6h 350 lm 35% 25VA Pb 6V 5Ah II 2,3
18 2184 626AT-18SA3P 3h 1150 lm 25% 24VA Pb 6V 5Ah II 2,5
2x18 2192 626AT-2x18SA1P 1h 2x1150 lm 30% 25VA Pb 6V 5Ah II 2,7
24 2172 626AT-24SA3P 3h 1800 lm 35% 25VA Pb 6V 5Ah II 2,7

CT Control unit - accessories PAG. 11 NON MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
8 2158 626CT-8SE5P 6h 350 lm 30% 3VA Pb 6V 5Ah II 2.3
9PL 2086 626CT-9SE3P 3h 600 lm 100% 6VA Pb 6V 5Ah II 2.3
11PL 2168 626CT-11SE5P 6h 900 lm 20% 6VA Pb 6V 5Ah II 2.3
18 2186 626CT-18SE3P 3h 1150 lm 25% 5VA Pb 6V 5Ah II 2.3
2x18 2194 626CT-2x18SE1P 1h 2x1150 lm 45% 5VA Pb 6V 5Ah II 2.5
24PL 2174 626CT-24SE3P 3h 1800 lm 25% 3VA Pb 6V 5Ah II 2.3

CT Control unit - accessories PAG. 11 MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
8 2159 626CT-8SA5P 6h 350 lm 35% 25VA Pb 6V 5Ah II 2.3
18 2187 626CT-18SA3P 3h 1150 lm 25% 24VA Pb 6V 5Ah II 2.5
2x18 2195 626CT-2x18SA1P 1h 2x1150 lm 30% 25VA Pb 6V 5Ah II 2.7
24PL 2175 626CT-24SA3P 3h 1800 lm 35% 25VA Pb 6V 5Ah II 2.7

CTOC Control unit - accessories PAG. 13 NON MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
8 2160 626CTOC-8SE5P 6h 350 lm 100% 3VA Pb 6V 5Ah II 2,3
9PL 2087 626CTOC-9SE3P 3h 900 lm 32% 13VA Pb 6V 5Ah II 2,3
11PL 2169 626CTOC-11SE5P 6h 350 lm 20% 6VA Pb 6V 5Ah II 2,3
18 2188 626CTOC-18SE3P 3h 1150 lm 25% 10VA Pb 6V 5Ah II 2.5
2X18 2197 626CTOC-2x18SE1P 1h 2X1150 lm 45% 5VA Pb 6V 5Ah II 2.5
24PL 2176 626CTOC-24SE3P 3h 1800 lm 25% 3VA Pb 6V 5Ah II 2.3

CTOC Control unit - accessories PAG. 13 MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
8 2161 626CTOC-8SA5P 6h 350 lm 35% 25VA Pb 6V 5Ah II 2,3
18 2189 626CTOC-18SA3P 3h 1150lm 25% 24VA Pb 6V 5Ah II 2,7
2X18 2198 626CTOC-2x18SA1P 1h 2x1150 lm 30% 25VA Pb 6V 5Ah II 2,7
24PL 2177 626CTOC-24SA3P 3h 1800 lm 35% 25VA Pb 6V 5Ah II 2.7

35
Industrial Luce series

CTS Control unit - accessories PAG. 18

W Ordering code Article Nominal flux Emergency efficiency Insulation Weight kg


8 2088 626CTS-8 350 lm 100% II 2.3
9PL 2090 626CTS-9 600 lm 100% II 2.3
11 2091 626CTS-11 900 lm 100% II 2.3
18 2093 626CTS-18 1150 lm 100% II 4.3
2x18 2094 626CTS-2x18 2x1150 lm 100% II 4.3
24 2092 626CTS-24 1800 lm 100% II 2.3

CTW Control unit PAG. 15

Ordering code Power supply Duration Battery Controlled Luminaires Weight kg


Control rack 9002 230V 3h NiCd 7.2V 1.2 Ah max 1024 4.7

Inibit Conversion table

AT Inibit remot control PAG.9 G R A N L U C E

Ordering code Article Inibit code Article Ordering code Article Inibit code Article
2084 626AT-9SE3P 2085 626AT-9SE3P/RM 2120 GL626AT-24SA3P 2121 GL626AT-24SA3P/RM
2098 GL626AT-8SE1P 2099 GL626AT-8SE1P/RM 2122 GL626AT-18SA1P 2123 GL626AT-18SA1P/RM
2100 GL626AT-8SE3P 2101 GL626AT-8SE3P/RM 2124 GL626AT-18SA3P 2125 GL626AT-18SA3P/RM
2102 GL626AT-11SE1P 2103 GL626AT-11SE1P/RM 2154 626AT-8SE5P 2155 626AT-8SE5P/RM
2104 GL626AT-11SE3P 2105 GL626AT-11SE3P/RM 2156 626AT-8SA5P 2157 626AT-8SA5P/RM
2106 GL626AT-24SE1P 2107 GL626AT-24SE1P/RM 2166 626AT-11SE5P 2167 626AT-11SE5P/RM
2108 GL626AT-24SE3P 2109 GL626AT-24SE3P/RM 2170 626AT-24SE3P 2171 626AT-24SE3P/RM
2110 GL626AT-18SE1P 2111 GL626AT-18SE1P/RM 2172 626AT-24SA3P 2173 626AT-24SA3P/RM
2112 GL626AT-18SE3P 2113 GL626AT-18SE3P/RM 2182 626AT-18SE3P 2183 626AT-18SE3P/RM
2114 GL626AT-8SA1P 2115 GL626AT-8SA1P/RM 2184 626AT-18SA3P 2185 626AT-18SA3P/RM
2116 GL626AT-8SA3P 2117 GL626AT-8SA3P/RM 2190 626AT-2x18SE1P 2191 626AT-2x18SE1P/RM
2118 GL626AT-24SA1P 2119 GL626AT-24SA1P/RM 2192 626AT-2x18SA1P 2193 626AT-2x18SA1P/RM

36
Beghelli Leggera IP65 AT

Available in 6W-8W-11PL-24PL, SA
(Maintained) and SE (Non Maintained),
1 and 3 hours, versions, is able to
conduct Self Testing autonomously
(AT version) .
Can be installed even
on flammable surfaces F
Power supply 230V (+10% / -6%)
Recharging time: 12 hours
Patented electronic circuit
PROTECTION
A LED indicates operation and condition
Possibility of enabling the emergency
function by a single command
IP 65
D E G R E E

Self-extinguishing plastic (standard EN


60598-1, UL94)
DIMENSIONS (mm) PROVIDED WITH
Designed for installation with Ø16 and W A B C • ADHESIVE LEGENDS
Ø20 tubes, for suspended or electrified 6W 280 120 60 • PG16-PG20 TUBE GLAND
C

TO BE ORDERED SEPARATELY,
rail, can be ceiling mounted 8W 400 150 65 • ADDITIONAL ADHESIVE LEGENDS

With the exception of 18W version, 11W 280 120 60


B

18W 660 114 94


Leggera IP65 can be installed to A 24W 400 150 65
meet IP65 by using the appropriate
additional shell
AT NON MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
6 8134 LEGGERA IP65 AT 6SE1N 1h 240 lm 35% 3VA NiCd 3.6V 1.2Ah II 0.9
8 8136 LEGGERA IP65 AT 8SE1N 1h 350lm 26% 3VA NiCd 3.6V 1.2Ah II 1.4
8 8137 LEGGERA IP65 AT 8SE3N 3h 350lm 26% 3VA NiCd 3.6V 1.8Ah II 1.7
11 8144 LEGGERA IP65 AT 11SE1N 1h 900m 24% 3VA NiCd 3.6V 1.2Ah II 0.9
18 8150 LEGGERA IP65 AT 18SE3P 3h 1150lm 25% 5VA Pb 6V 4Ah II 2.6
24 8146 LEGGERA IP65 AT 24SE1N 1h 1800lm 25% 4VA NiCd 6V 1.8Ah II 1.7

AT MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
6 8138 LEGGERA IP65 AT 8SA1N 1h 350lm 32% 3VA NiCd 6V 1.2Ah II 1.4
8 8139 LEGGERA IP65 AT 8SA3N 3h 350lm 35% 3VA NiCd 6V 1.8Ah II 1.7
18 8151 LEGGERA IP65 AT 18SA3P 3h 1150lm 28% 5VA Pb 6V 4Ah II 2.6
24 8148 LEGGERA IP65 AT 24SA1N 1h 1800lm 22% 4VA NiCd 6V 1.8Ah II 1.7

AT INIBIT CONVERSION TABLE G R A N L U C E Inibit remot control PAG.9

Ordering code Article Inibit code Article Ordering code Article Inibit code Article
8134 LEGGERA IP65 AT 6SE1N 8135 LEGGERA IP65 AT 6SE1N/RM 8144 LEGGERA IP65 AT 11SE1N 8145 LEGGERA IP65 AT 11SE1N/RM
8136 LEGGERA IP65 AT 8SE1N 8140 LEGGERA IP65 AT 8SE1N/RM 8146 LEGGERA IP65 AT 24SE1N 8147 LEGGERA IP65 AT 24SE1N/RM
8137 LEGGERA IP65 AT 8SE3N 8141 LEGGERA IP65 AT 8SE3N/RM 8148 LEGGERA IP65 AT 24SA1N 8149 LEGGERA IP65 AT 24SA1N/RM
8138 LEGGERA IP65 AT 8SA1N 8142 LEGGERA IP65 AT 8SA1N/RM 8150 LEGGERA IP65 AT 18SE3P 8152 LEGGERA IP65 AT 18SE3P/RM
8139 LEGGERA IP65 AT 8SA3N 8143 LEGGERA IP65 AT 8SA3N/RM 8151 LEGGERA IP65 AT 18SA3P 8153 LEGGERA IP65 AT 18SA3P/RM
37
Beghelli

Available in 6 - 8 - 11 - 18 - 24PL/W,
SA (Maintained) and SE (Non
Maintained), 1-3 hours, versions, is able
to conduct autonomously (AT version) or PROTECTION
via the CU(CT-CTOC versions) Self
Testing, periodic operational and full
duration tests. With the interface CTW
IP 65
D E G R E E

the monitoring, control and test function


can be run via internet. DIMENSIONS (mm) PROVIDED WITH
Reflector and diffuser developed W A B C
• IP 65 PROTECTIVE SHELL +
PG16-PG20 TUBE GLAND
by Fiat Research Centre
C

6W 300 138 55 TO BE ORDERED SEPARATELY


• PROTECTIVE GRILLE
8W 418 168 62
Can be installed even • ADDITIONAL ADHESIVE LEGENDS
11W 300 138 55
B

on flammable surfaces F 18W 658 118 94


Power supply 230V (+10% / -6%) A 24W 418 168 62

Recharging time : 12 hours


Patented electronic circuit
Available in ecological version with
long life NiMh green batteries
A LED indicates operation and condition.
Possibility of enabling the emergency
function by a single command.
Self-extinguishing plastic (standard
EN 60598-1, UL94)
For 6 and 11 Watt units, especially suit- Wall or ceiling mounting with Ø16 / Ø20
Fluorescent tube powered by energy
able for wall-mounting, the angle of light tubes
saving electronic ballast (SA-Maintained distribution has been specially adjusted
versions) to perform better floor-lighting.
Designed for installation with Ø16 and Ø20
tubes, for suspended or electrified rail

Flush mounted in false ceiling Installation on electrified rail or chain


suspension.
cd/1000 lm Pratica Completa 6W cd/1000 lm Pratica Completa 8W cd/1000 lm Pratica Completa 11W cd/1000 lm Pratica Completa 18W cd/1000 lm Pratica Completa 24W
90° 90°
90° 90°
90° 90° 90° 90° 90° 90°

50 75° 40 75°
75° 75° 50
75° 75° 75° 40 75°
75° 40 75°

100 80
100 60° 60°
60° 60°
60° 60° 60° 80 60°
80 60°
60°
150 150 120
120 120 45° 45°
45° 45° 200
200 45° 45° 45° 45° 45° 160
45°
160 160
250
250 200
30° 15° 0° 15° 30° 30° 15° 0° 15° 30° 30° 15° 0° 15° 30° 30° 15° 0° 15° 30° 30° 15° 0° 15° 30°
C180 C270 C0 C90 C180 C270 C0 C90 C180 C270 C0 C90 C180 C270 C0 C90 C180 C270 C0 C90

38
Pratica Completa 626 IP65 AT - CT - CTOC - CTW

AT NON MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
6 1950 CS626AT-6SE1H 1h 240 lm 35% 3VA NiMH 3.6V 1.2Ah II 0.9
6 1952 CS626AT-6SE1N 1h 240 lm 35% 3VA NiCd 3.6V 1.2Ah II 0.9
8 1987 CS626AT-8SE1H 1h 350 lm 26% 3VA NiMH 3.6V 1.2Ah II 1.4
8 1999 CS626AT-8SE1N 1h 350 lm 26% 3VA NiCd 3.6V 1.2Ah II 1.4
8 1988 CS626AT-8SE3H 3h 350 lm 26% 3VA NiMH 3.6V 1.8Ah II 1.7
8 2000 CS626AT-8SE3N 3h 350 lm 26% 3VA NiCd 3.6V 1.8Ah II 1.7
11PL 1959 CS626AT-11SE1H 1h 900 lm 24% 3VA NiMH 3.6V 1.2Ah II 0.9
11PL 1961 CS626AT-11SE1N 1h 900 lm 24% 3VA NiCd 3.6V 1.2Ah II 0.9
18 2050 CS626AT-18SE3P 3h 1150 lm 25% 5VA Pb 6V 4Ah II 2.6
24Pl 2026 CS626AT-24SE1H 1h 1800 lm 25% 4VA NiMH 6V 1.8Ah II 1.7
24PL 2032 CS626AT-24SE1N 1h 1800 lm 25% 4VA NiCd 6V 1.8Ah II 1.7

AT MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
8 1989 CS626AT-8SA1H 1h 350 lm 32% 13VA NiMH 6V 1.2Ah II 1.6
8 2001 CS626AT-8SA1N 1h 350 lm 32% 13VA NiCd 6V 1.2Ah II 1.6
8 1990 CS626AT-8SA3H 3h 350 lm 35% 25VA NiMH 6V 1.8Ah II 1.7
8 2002 CS626AT-8SA3N 3h 350 lm 35% 25VA NiCd 6V 1.8Ah II 1.7
18 2051 CS626AT-18SA3P 3h 1150 lm 28% 25VA Pb 6V 4Ah II 2.6
24PL 2028 CS626AT-24SA1H 1h 1800 lm 22% 40VA NiMH 6V 1.8Ah II 1.7
24PL 2034 CS626AT-24SA1N 1h 1800 lm 22% 40VA NiCd 6V 1.8Ah II 1.7

CT Control unit - accessories PAG. 11 NON MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
8 2009 CS626CT-8SE1N 1h 350 lm 26% 3VA NiCd 6V 1.2Ah II 1.4
8 2010 CS626CT-8SE3N 3h 350 lm 26% 3VA NiCd 6V 2Ah II 1.7
18 2054 CS626CT-18SE3P 3h 1150 lm 25% 5VA Pb 6V 4Ah II 2.6
24PL 2036 CS626CT-24SE1N 1h 1800 lm 25% 4VA NiCd 6V 1.2Ah II 1.7

CT Control unit - accessories PAG. 11 MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
8 2011 CS626CT-8SA1N 1h 350 lm 32% 13VA NiCd 6V 1.2Ah II 1.4
8 2012 CS626CT-8SA3N 3h 350 lm 35% 25VA NiCd 6V 2Ah II 1.4
18 2055 CS626CT-18SA3P 3h 1150 lm 28% 25VA Pb 6V 4Ah II 2.6

39
Pratica Completa 626

CTOC Control unit - accessories PAG. 13 NON MAINTAINED LIGHTING

W Ordering code Article Autonomy Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
8 2013 CS626CTOC-8SE1N 1h 350 lm 26% 3VA NiCd 6V 1.2Ah II 1,4
8 2014 CS626CTOC-8SE3N 3h 350 lm 26% 3VA NiCd 6V 2Ah II 1,4
18 2056 CS626CTOC-18SE3P 3h 1150 lm 25% 5VA Pb 6V 4Ah II 2,6
24PL 2038 CS626CTOC-24SE1N 1h 1800 lm 25% 4VA NiCd 6V 2Ah II 1,7

CTOC Control unit - accessories PAG. 13 MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
8 2015 CS626CTOC-8SA1N 1h 350 lm 32% 13VA NiCd 6V 1.2Ah II 1,4
8 2016 CS626CTOC-8SA3N 3h 350 lm 35% 25VA NiCd 6V 2Ah II 1,4
18 2057 CS626CTOC-18SA3P 3h 1150 lm 28% 25VA Pb 6V 4Ah II 2,6

CTW Control unit PAG. 15

Ordering code Power supply Duration Battery Controlled Luminaires Weight kg


Control rack 9002 230V 3h NiCd 7.2V 1.2 Ah max 1024 4.7

Inibit Conversion table

AT Inibit remot control PAG.9 G R A N L U C E

Ordering code Article Inibit code Article Ordering code Article Inibit code Article
1950 CS626AT-6SE1H 1951 CS626AT-6SE1H/RM 2000 CS626AT-8SE3N 2004 CS626AT-8SE3N/RM
1952 CS626AT-6SE1N 1953 CS626AT-6SE1N/RM 2001 CS626AT-8SA1N 2005 CS626AT-8SA1N/RM
1959 CS626AT-11SE1H 1960 CS626AT-11SE1H/RM 2002 CS626AT-8SA3N 2006 CS626AT-8SA3N/RM
1961 CS626AT-11SE1N 1962 CS626AT-11SE1N/RM 2026 CS626AT-24SE1H 2027 CS626AT-24SE1H/RM
1987 CS626AT-8SE1H 1991 CS626AT-8SE1H/RM 2028 CS626AT-24SA1H 2029 CS626AT-24SA1H/RM
1988 CS626AT-8SE3H 1992 CS626AT-8SE3H/RM 2032 CS626AT-24SE1N 2033 CS626AT-24SE1N/RM
1989 CS626AT-8SA1H 1993 CS626AT-8SA1H/RM 2034 CS626AT-24SA1N 2035 CS626AT-24SA1N/RM
1990 CS626AT-8SA3H 1994 CS626AT-8SA3H/RM 2050 CS626AT-18SE3P 2052 CS626AT-18SE3P/RM
1999 CS626AT-8SE1N 2003 CS626AT-8SE1N/RM 2051 CS626AT-18SA3P 2053 CS626AT-18SA3P/RM

40
Beghelli Pratica Tuttovetro 626
AT-CT-CTOC- CTW

Available in 6 - 8 - 11PL - 18 - 24PL / W,


SA (Maintained) and SE (Non
Maintained), 1 and 3 hours versions, is
able to conduct autonomously (AT ver-
sion) or via the CU (CT-CTOC versions)
Self Testing, periodic operational and full
duration tests.
With the interface CTW the monitoring,
control and tests function can be run via PROTECTION

internet.
Can be installed even
IP40-IP65
D E G R E E

on flammable surfaces F
Power supply 230V (+10% / -6%) DIMENSIONS (mm) PROVIDED WITH
• ADHESIVE LEGENDS
Recharging time : 12 hours W A B C TO BE ORDERED SEPARATELY
6W 304 142 49
C

• SUSPENSION HOOKS
Patented electronic circuit 8W 380 142 49 • PROTECTIVE GRILLE
• IP 65 PROTECTIVE SHELL + PG16-PG20
Available in ecological version with 11W 304 142 55 TUBE GLAND
B

18W 660 165 51 • ADDITIONAL ADHESIVE LEGENDS


long life NiMh batteries 24W 380 142 63
• ADAPTOR FOR MOUNTING IN 3-ENTRY
A RECESSEED BOX
Designed for installation with Ø16 and
Ø20 tubes, for suspended or electri-
fied rail, the IP40 version is designed 1
with a quick-fit fixing bracket to
minimize installation time.
With the exception of 18W version,
Pratica tuttovetro 626 can be installed 2
to meet IP65 version by using the
appropriate additional shell
A LED indicates operation and condition.
Possibility of enabling the emergency Additional IP65 protective shell
function by a single command (Beghelli patent)
3
Self-extinguishing plastic (standard EN 4
60598-1, UL94)
Fluorescent tube powered by energy
saving electronic ballast (SA-Maintained
Installation with the additional IP65 protective shell does not alter the photometric
versions) characteristics or the termal equilibrium of the luminaires (IEC 64-8).
The luminaire + shell combination is certified IP65 by the IMQ (standard EN 60598-1)

cd/1000 lm Pratica Tuttovetro 6W cd/1000 lm Pratica Tuttovetro 8W cd/1000 lm Pratica Tuttovetro 11W cd/1000 lm Pratica Tuttovetro 18W cd/1000 lm Pratica Tuttovetro 24W
90° 90° 90° 90° 90° 90° 90° 90°
90° 90°

75° 40 75° 75° 40 75° 75° 75° 75°


75° 40 75° 40 75°
40

80 80 60°
60° 60° 60° 60° 60° 80 60° 60° 60°
60°
80 80
120 120
120
45° 45° 45° 45° 120 45° 120 45°
45° 45° 45° 45°
160 160
160

200 160 160


200
30° 15° 0° 15° 30° 30° 15° 0° 15° 30° 30° 15° 0° 15° 30° 30° 15° 0° 15° 30° 30° 15° 0° 15° 30°
C180 C270 C0 C90 C180 C270 C0 C90 C180 C270 C0 C90 C180 C270 C0 C90 C180 C270 C0 C90
41
Pratica Tuttovetro 626

AT NON MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
6 1484 TV626AT-6SE1H 1h 240 lm 35% 3VA NiMH 3.6V 1.2Ah II 1
8 1500 TV626AT-8SE1H 1h 350 lm 26% 3VA NiMH 3.6V 1.2Ah II 1,6
8 1502 TV626AT-8SE3H 3h 350 lm 22% 4VA NiMH 6V 1,8Ah II 1,8
8 1687 929AT-8SE1N 1h 350 lm 33% 4VA NiCd 6V 0.8Ah II 1,2
8 1686 929AT-8SE3N 3h 350 lm 35% 5VA NiCd 6V 1.8Ah II 1.4
11PL 1540 TV626AT-11SE1H 1h 900 lm 20% 4VA NiMH 3,6V 1,8Ah II 1.2
18 1548 TV626AT-18SE1H 1h 1150 lm 25% 6VA NiMH 6V 1,8Ah II 2,7
18 1705 930AT-18SE3N 3h 1150 lm 30% 7VA NiCd 6V 4Ah II 2,8
24PL 1558 TV626AT-24SE1H 1h 1800 lm 25% 4VA NiMH 6V 1,8Ah II 1,8
24PL 1737 957AT-24SE1N 1h 1800 lm 25% 5VA NiCd 6V 1.8Ah II 1,8

AT MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
8 1508 TV626AT-8SA1H 1h 350 lm 25% 13VA NiMH 6V 1.2Ah II 1.8
8 1510 TV626AT-8SA3H 3h 350 lm 25% 13VA NiMH 6V 1.8Ah II 2,2

CT Control unit - accessories PAG. 11 NON MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
8 1516 TV626CT-8SE1H 1h 350 lm 26% 3VA NiMH 6V 1,2Ah II 1,6
8 1517 TV626CT-8SE3H 3h 350 lm 22% 4VA NiMH 6V 1,8Ah II 1,8
8 1680 929CT-8SE1N 1h 350 lm 33% 4VA NiCd 6V 0.8Ah II 1,2
8 1678 929CT-8SE3N 3h 350 lm 35% 5VA NiCd 6V 1.8Ah II 1,8
18 1552 TV626CT-18SE1H 1h 1150 lm 25% 6VA NiMH 6V 1,8Ah II 2,7
24PL 1566 TV626CT-24SE1H 1h 1800 lm 25% 4VA NiMH 6V 1,8Ah II 1,8
24PL 1735 957CT-24SE1N 1h 1800 lm 25% 5VA NiCd 6V 1.8Ah II 1,8

CT Control unit - accessories PAG. 11 MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
8 1520 TV626CT-8SA1H 1h 350 lm 25% 13VA NiMH 6V 1.2Ah II 1,8
18 1521 TV626CT-8SA3H 3h 350 lm 25% 13VA NiMH 6V 1.8Ah II 1,8
24PL 1569 TV626CT-24SA1H 1h 1800 lm 25% 5VA NiMH 6V 1.8Ah II 1,8

42
Pratica Tuttovetro 626

CTOC Control unit - accessories PAG. 13 NON MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
8 1524 TV626CTOC-8SE1H 1h 350 lm 26% 3VA NiMH 3,6V 1,2Ah II 1,6
8 1525 TV626CTOC-8SE3H 3h 350 lm 22% 4VA NiMH 6V 1,8Ah II 1,8
8 1684 929CTOC-8SE1N 1h 350 lm 33% 4VA NiCd 6V 0.8Ah II 1,2
8 1682 929CTOC-8SE3N 3h 350 lm 35% 5VA NiCd 6V 1.8Ah II 1,8
18 1554 TV626CTOC-18SE1H 1h 1150 lm 25% 6VA NiMH 6V 1,8Ah II 2,7
24PL 1570 TV626CTOC-24SE1H 1h 1800 lm 25% 4VA NiMH 6V 1,8Ah II 1,8
24PL 1738 957CTOC-24SE1N 1h 1800 lm 25% 5VA NiCd 6V 1.8Ah II 1,8

CTOC Control unit - accessories PAG. 13 MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
8 1528 TV626CTOC-8SA1H 1h 350 lm 25% 13VA NiMH 6V 1,2Ah II 1,8
8 1529 TV626CTOC-8SA3H 3h 350lm 25% 13VA NiMH 6V 1.8Ah II 2,2
24PL 1573 TV626CTOC-24SA1H 1h 1800 lm 25% 5VA NiCd 6V 1.8Ah II 1,8

CTW Control unit PAG. 15

Ordering code Power supply Duration Battery Controlled Luminaires Weight kg


Control rack 9002 230V 3h NiCd 7.2V 1.2 Ah max 1024 4.7

Inibit Conversion table

AT Inibit remot control PAG.9 G R A N L U C E

Ordering code Article Inibit code Article Ordering code Article Inibit code Article
1484 TV626AT-6SE1H 1485 TV626AT-6SE1H/RM 1510 TV626AT-8SA3H 1511 TV626AT-8SA3H/RM
1500 TV626AT-8SE1H 1501 TV626AT-8SE1H/RM 1540 TV626AT-11SE1H 1541 TV626AT-11SE1H/RM
1502 TV626AT-8SE3H 1503 TV626AT-8SE3H/RM 1548 TV626AT-18SE1H 1549 TV626AT-18SE1H/RM
1508 TV626AT-8SA1H 1509 TV626AT-8SA1H/RM 1558 TV626AT-24SE1H 1559 TV626AT-24SE1H/RM

43
Beghelli

Available in 2X6W and 2X8W, SA


(Maintained) and SE (Non Maintained),
versions, is able to conduct auto-
nomously (AT version) or via the CU (CT PROTECTION

version) Self Testing, periodic operational


and autonomy tests.
With the interface CTW the monitoring,
IP 40
D E G R E E

control and test function can be run


via internet. DIMENSIONS (mm) PROVIDED WITH
TO BE ORDERED SEPARATELY,
Can be installed even W A B C D E F •.SIGNALLING SCREENS
on flammable surfaces F B
C 2x6W 276 276 358 358 110 60
2x8W 390 276 358 472 110 60
Power supply 230V (+10% / -6%) A

Recharging time : 12 hours


E

D
Patented electronic circuit
Available in ecological version
with long life NiMh batteries
Designed with a quick-fit fixing bracket SA devices with
to minimize installation time and for high energy-saving
ceiling mounting and wall mounting . electronic ballast

A LED indicates operation and condition.


Possibility of enabling the emergency
function by a single command
Self-extinguishing plastic (standard
EN 60598-1, UL94)
Fluorescent tube powered by energy
saving electronic ballast (SA-Maintained
versions)

Installation system alllowing for wall or ceiling mounting with quick-fit fixing and
44 electrical connection system (Beghelli patent)
Pratica Bandiera AT - CT - CTW

AT NON MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
2X6 2309 9166ATSE2P 3h 2x240 lm 60% 10VA Pb 6V 6.5Ah II 2,9
2X8 2321 9188ATSE2P 3h 2x350 lm 45% 10VA Pb 6V 6.5Ah II 3,2

AT MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
2X6 2314 9166ATSA3P 3h 2x240 lm 45% 22VA Pb 6V 6.5Ah I 3
2X8 2326 9188ATSA3P 3h 2x350 lm 45% 24VA Pb 6V 6.5Ah I 3,3

CT Control unit - accessories PAG. 11 NON MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
2X6 2310 9166CTSE2P 3h 2x240 lm 60% 10VA Pb 6V 6.5Ah II 2,9
2X8 2322 9188CTSE2P 3h 2x350 lm 45% 10VA Pb 6V 6.5Ah II 3,2

CT Control unit - accessories PAG. 11 MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
2X6 2315 9166CTSA3P 3h 2x240 lm 45% 22VA Pb 6V 6.5Ah I 3
2X8 2327 9188CTSA3P 3h 2x350 lm 45% 24VA Pb 6V 6.5Ah I 3,2

CTW Control unit PAG. 15

Ordering code Power supply Duration Battery Controlled Luminaires Weight kg


Control rack 9002 230V 3h NiCd 7.2V 1.2 Ah max 1024 4.7

45
aa
aaa
a
aa
a
a
a a
aaaaaaa
aa
a a
aaaaaaBeghelli

Power supply 230V (+10% / -6%)


Recharging time : 12 hours
Patented electronic circuit
Available in ecological version
with long life NiMh batteries
a
control and tests function can be
run via internet.
Can be installed even
on flammable surfaces F

Designed with a quick-fit fixing


aa
a
aaaaaa
Available in 8W, SA (Maintained) and SE
(Non Maintained), 1 and 3 hours, ver-
sions, is able to conduct autonomously
(AT version) or via the CU (CT-CTOC-CTS
versions) Self Testing periodic operational
and full duration tests.
With the interface CTW the monitoring,

bracket to minimize installation time


Tuttovetro bandiera can be installed in
IP65 version by using the appropriate
additional shell (Beghelli patented
system)

A LED indicates operation and condition.


Possibility of enabling the emergency
function by a single command
Self-extinguishing plastic (standard EN
60598-1, UL94)
Fluorescent tube powered by energy sa
ving electronic ballast (SA-Maintained
versions)
Designed for ceiling mounting, suspen-
ded installation with hooks or wall instal-
lation with brackets supplied.
B

IP40
A

with the unit

IP65
DIMENSIONS (mm)

C
W
8W

Wall mounting with bracket supplied


A

Ceiling mounting with IP65 protective


shell supplied with the unit
B C
380 194 142

IP40




Ceiling mounting

IP65
PROTECTION

IP40-IP65
D E G R E E

PROVIDED WITH
ADHESIVE LEGENDS
IP65 PROTECTIVE SHELL
PG16-PG20 TUBE GLAND
SUSPENSION HOOKS
BRACKET FOR WALL MOUNTING

Suspended installation with suspension


hooks and IP65 protective shell supplied
with the unit

IP65
a
Wall mounting with bracket and IP65 pro- IP65 protective shell supplied with the
tective shell supplied with the unit. device (Beghelli patent)
46
Tuttovetro Bandiera AT- CT - CTOC - CTS - CTW

AT NON MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
8 1574 TVB626AT-8SE1H 1h 350 lm 20% 3VA NiMH 3,6V 1,2Ah II 1.6
8 1576 TVB626AT-8SE3H 3h 350 lm 20% 3VA NiMH 3,6V 4Ah II 1.6
8 1934 967AT-8SE1N 1h 350 lm 33% 4VA NiCd 6V 0.8 Ah II 1.6
8 1933 967AT-8SE3N 3h 350 lm 33% 7VA NiCd 6V 1.8 Ah II 1.8

AT MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
8 1578 TVB626AT-8SA1H 1h 350lm 25% 13VA NiMH 6V 1.2Ah II 1.8

CT Control unit - accessories PAG. 11 NON MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
8 1582 TVB626CT-8SE1H 1h 350 lm 20% 3VA NiMH 3,6V 1,2Ah II 1,6
8 1932 967CT-8SE1N 1h 350 lm 33% 4VA NiCd 6V 0.8 Ah II 1,6
8 1931 967CT-8SE3N 3h 350 lm 35% 7VA NiCd 6V 1.8 Ah II 1,8

CT Control unit - accessories PAG. 11 MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
8 1584 TVB626CT-8SA1H 1h 350lm 25% 13VA NiMH 6V 1.2Ah II 1,8

CTOC Control unit - accessories PAG. 13 NON MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
8 1585 TVB626CTOC-8SE1H 1h 350 lm 20% 3VA NiMH 3,6V 1,2Ah II 1,6
8 1936 967CTOC-8SE1N 1h 350 lm 33% 4VA NiCd 6V 0.8 Ah II 1,6
8 1935 967CTOC-8SE3N 3h 350 lm 35% 7VA NiCd 6V 1.8 Ah II 1,8

CTOC Control unit - accessories PAG. 13 MAINTAINED LIGHTING

W Ordering code Article Duration Nominal flux Emergency efficiency Max absorption Battery Insulation Weight kg
8 1587 TVB626CTOC-8SA1H 1h 350 lm 25% 13VA NiMH 6V 1,2Ah II 1,8

CTS Control unit - accessories PAG. 18

W Ordering code Article Nominal flux Emergency efficiency Insulation Weight kg


8 1588 TVB626CTS-8 350lm 100% II 2,3

CTW Control unit PAG. 15

Ordering code Power supply Duration Battery Controlled Luminaires Weight kg


Control rack 9002 230V 3h NiCd 7.2V 1.2 Ah max 1024 4.7

AT Inibit remot control PAG.9 G R A N L U C E

Ordering code Article Inibit code Article Ordering code Article Inibit code Article
1574 TVB626AT-8SE1H 1575 TVB626AT-8SE1H/RM 1578 TVB626AT-8SA1H 1579 TVB626AT-8SA1H/RM
1576 TVB626AT-8SE3H 1577 TVB626AT-8SE3H/RM
47
Beghelli
New, High efficiency LED technology,
available in SA (Maintained) versions, is
able to conduct autonomously (AT ver-
sion) or via the CU(CT-CTOC, CTS ver-
sions) Self Testing, periodic operational PROTECTION

and full duration tests, ensuring a lamp


life cycle of 100.000 hours (more than
10 years). With the interface CTW the
IP 40
D E G R E E

monitoring, control and test function can


be run via internet. DIMENSIONS (mm)
A C

Zero maintenance costs :


due to long life LEDs lamp and
battery quick change system .

B
Reduced installation costs .
Can be installed even
on flammable surfaces F A B C
Power supply 230V (+10% / -6%) 380 240 58

Recharging time : 12 hours Ceiling support.


Patented electronic circuit
Available in ecological version
with long life NiMh batteries
A LED indicates operation and condition.
Possibility of enabling the emergency
function by a single command
Self-extinguishing plastic
(standard EN 60598-1, UL94)
Designed for ceiling mounting,
suspended installation with hooks or Suspended installation with suspension Wall installation with supplied bracket
wall installation with brackets supplied. hooks

AT MAINTAINED LIGHTING

Ordering code Inibit code Duration Max absorption Battery Insulation Weight kg
LED 3926 3930 1h 8VA 6V 1.2Ah NiMH II 1,5
LED 3927 3931 3h 8VA 6V 1.2Ah NiMH II 1,5
LED 3924 3928 1h 8VA 6V 0.75Ah NiCd II 1,5
LED 3925 3929 3h 8VA 6V 1.2Ah NiCd II 1,5

AT MAINTAINED LIGHTING

Ordering code Inibit code Duration Max absorption Battery Insulation Weight kg
LED 3946 3950 1h 8VA 6V 1.2Ah NiMH II 1,5
LED 3947 3951 3h 8VA 6V 1.2Ah NiMH II 1,5
LED 3944 3948 1h 8VA 6V 0.75Ah NiCd II 1,5
LED 3945 3949 3h 8VA 6V 1.2Ah NiCd II 1,5
48
Led Exite Sign 626 AT-CT-CTOC-CTS-CTW

CT Control unit - accessories PAG. 11 MAINTAINED LIGHTING

Ordering code Duration Max absorption Battery Insulation Weight kg


LED 3934 1h 8VA 6V 1.2Ah NiMH II 1,5
LED 3935 3h 8VA 6V 1.2Ah NiMH II 1,5
LED 3932 1h 8VA 6V 0.75Ah NiCd II 1,5
LED 3933 3h 8VA 6V 1.2Ah NiCd II 1,5

CT Control unit - accessories PAG. 11 MAINTAINED LIGHTING

Ordering code Duration Max absorption Battery Insulation Weight kg


LED 3954 1h 8VA 6V 1.2Ah NiMH II 1,5
LED 3955 3h 8VA 6V 1.2Ah NiMH II 1,5
LED 3952 1h 8VA 6V 0.75Ah NiCd II 1,5
LED 3953 3h 8VA 6V 1.2Ah NiCd II 1,5

CTOC Control unit - accessories PAG. 13 MAINTAINED LIGHTING

Ordering code Duration Max absorption Battery Insulation Weight kg


LED 3938 1h 8VA 6V 1.2Ah NiMH II 1,5
LED 3939 3h 8VA 6V 1.2Ah NiMH II 1,5
LED 3936 1h 8VA 6V 0.75Ah NiCd II 1,5
LED 3937 3h 8VA 6V 1.2Ah NiCd II 1,5

CTOC Control unit - accessories PAG. 13 MAINTAINED LIGHTING

Ordering code Duration Max absorption Battery Insulation Weight kg


LED 3958 1h 8VA 6V 1.2Ah NiMH II 1,5
LED 3959 3h 8VA 6V 1.2Ah NiMH II 1,5
LED 3956 1h 8VA 6V 0.75Ah NiCd II 1,5
LED 3957 3h 8VA 6V 1.2Ah NiCd II 1,5

CTS Control unit - accessories PAG. 18

Ordering code Insulation Weight kg


LED 3940 II 1,5

CTS Control unit - accessories PAG. 18

Ordering code Insulation Weight kg


LED 3960 II 1,5

CTW Control unit PAG. 15

Ordering code Power supply Duration Battery Controlled Luminaires Weight kg


Control rack 9002 230V 3h NiCd 7.2V 1.2 Ah max 1024 4.7
49
Beghelli Conversion kit AT-CT-CTOC-CTW

Electronic conversion kit for fluorescent


lamps, with the ability to conduct peri-
odic operational and full duration tests
following a pre-installed program.
Test results are displayed via the colour
LED of the unit. With the interface CTW
the monitoring, control and test function
can be run via internet..
Easy installation in fittings
Complete with sealed rechargeable
battery packs (patented connection
system)
Duration and emergency power
supply automatically adjusted to suit
the connected lamp
Power supply : 230 V
Recharging time : 24 hours DIMENSIONS (mm)
323 33
A LED indicates operation
and condition 263 40 36
400
270 Art. 935.4
Operationg temperature : 0-40° C Lamp 18W 36W 58W
Control temperature : TC 55° C Power factor 0,30 0,21 0,15
Autonomy 2h30 1h30 1h
Quick-fit electrical connection

AT MAINTAINED LIGHTING

Ordering code Article Tube Duration Max absorption Battery Weight kg


2571 935.4AT 18-58SA 18÷58 1÷2h30min 7VA NiCd 6V 4Ah 1,6

CT Control unit - accessories PAG. 11 MAINTAINED LIGHTING

Ordering code Article Tube Duration Max absorption Battery Weight kg


2573 935.4CT 18-58SA 18÷58 1÷2h30min 7VA NiCd 6V 4Ah 1,6

CTOC Control unit - accessories PAG. 13 NON MAINTAINED LIGHTING

Ordering code Article Tube Duration Max absorption Battery Weight kg


2574 935.4CTOC 18-58SA 18÷58 1÷2h30min 7VA NiCd 6V 4Ah 1,6

AT Inibit remot control PAG. 9 MAINTAINED LIGHTING

Ordering code Article Tube Duration Max absorption Battery Weight kg


2572 935.4AT 18-58SA/RM 18÷58 1÷2h30min 7VA NiCd 6V 4Ah 1,6

CTW Control unit PAG. 15

Ordering code Power supply Duration Battery Controlled Luminaires Weight kg


Control rack 9002 230V 3h NiCd 7.2V 1.2 Ah max 1024 4.7
50
Beghelli CTS Conversion Kit

CTS conversion kit is a device designed


to integrate a standard mains lighting
fixture with the Beghelli CTS.
Additionally the CTS Conversion kit per-
forms checks of the lighting fixture
efficiency by a photodiode.
Depending on the type of CTS kit elec-
trical connection, the fixture can be used
either as a SE (Non Maintained) or SE
(Maintained) fitting. With a specific pro-
gram it’s also possible to set the lighting
fixture’s full duration as 1h or 3h.
SA permanent input: 230 VAC
DIMENSIONS (mm)
Relay input : 230VAC

D
W A B C
Current : Max output 4A 8W 400 170 89
Two coloured LEDs indicate C
power supply and fault condition
B
Operationg temperature : 0-40° C A

Photodiode for checking the


proper fixture operation

CTS Control unit - accessories PAG. 18 NON MAINTAINED LIGHTING

Ordering code Article Max output Insulation Weight kg


3015 9428CTS 3A 230V I 0,5