The manual
-1-
Power failure relief installation
Dangerous
• Please check whether the ARD has been damaged in the transportation process
before the ARD unpacking, installation, wiring and operation. If you have any contact
with the Marketing Department or technical department of the department.
• Before installation, please carefully read the instructions of this product. Please
strictly follow the content requirements of the instructions, and standardize the
installation measures. Failure to comply with these matters may result in death or
serious injury, damage to the product, and the original elevator system.
• Do not directly touch the input/output terminals, the components on the control
panel, the danger of electric shock and damage control panel.
• Before the connection, please confirm that the input power is disconnected, and
the electric operation has the hazard of electric shock and fire.
Attention
• Do not connect the three-phase power input line to the output U, V, W terminal,
and the voltage on the output terminal will cause the internal damage of ARD.
• When connecting the power line, use the specified screwdriver to tighten the
terminal.
• In order to explain the details of the product, the principle diagram of the
device is sometimes used as the state of the outer cover (door) or the security
covering; When running this product, please make sure to pack the outer cover (door)
or cover, and use the content of the instruction to carry out the operation.
-2-
Power failure relief installation
DIRECTORY
-3-
Power failure relief installation
ARD profile
To improve the reliability of elevator running, avoid because of external power
grid blackout, lack of phase, fault phase caused by the elevator people phenomenon,
and therefore the passengers of physical and mental damage, the company's research
and development series elevator power automatic emergency rescue equipment,
hereinafter referred to as ARD.
ARD is a backup emergency power system outside the original elevator control
and frequency conversion system. ARD has the features of simple installation wiring,
convenient debugging and high cost performance. When the power outage of the
three-phase power grid, ARD will automatically put into work in the setting time,
slowly move the elevator car to the nearest platform, open the door, and release the
passengers. Thus the maximum mitigated personnel ladder injury.
(1) The installation, connection and commissioning of ARD shall be carried out by
relevant technicians in elevator industry.
(2) Prior to the installation, connection and maintenance of ARD, please ensure that
the power switch of ARD and the total power supply of the elevator are turned off,
otherwise the ARD will start to power supply, which will cause the danger of electric
shock.
-4-
Power failure relief installation
(4) Please follow the instructions or warnings in the manual to prevent damage to
the installation or maintenance personnel, while avoiding damage to the elevator
equipment.
(5) Please confirm that the connection between ARD and the elevator system is
correct before switching on the three-phase power supply.
4. This manual introduces the installation and fixing of ARD, the description of the
connection steps, the debugging and use, the failure and elimination methods, etc.,
and introduces the external signal terminal of ARD.
-5-
Power failure relief installation
2. ARD terminal
A. Communication terminal(ZA01)
1 2 3 4 5
10 9 8 7 6
-6-
Power failure relief installation
One of the dialing switches is used to control the start delay time:ON:15S;OFF:30S。
The two bits of the dial switch are used to control the reverse output time :
ON:180S;OFF:360S。
connection. Check and confirm wiring correctly. Please ensure that the three-phase
power supply RI SI TI and RO SO TO have no fault, otherwise it will cause ARD
irreparable damage.
3. First connect the normal three-phase power supply, then the control switch
ON ARD panel ON the ARD panel, the yellow indicator ON ARD panel flashes,
ARD is in standby mode, and the battery group is automatically charged.
4. The blue indicator on ARD panel lights up when the three-phase power fails,
and the blue indicator on the rear panel flashes, the ARD is in contravariant mode,
and the elevator system is supplied with power. After the 180S or 360S, ARD will
automatically stop running and wait for the three-phase power supply to return to the
standby mode automatically.
5. The product has the function of output short circuit protection, overcurrent
protection and battery protection. Battery charging has overpressure, under pressure
and overcurrent protection function, which can prevent the battery from being
damaged by overpressure, under voltage and overcurrent charging.
6. There is no need for internal debugging after the product leaves the factory.
Please contact us if you need to adjust the internal adjustment.
-8-
Power failure relief installation
“ON” “0FF”
-9-
Power failure relief installation
The fault
Failure analysis countermeasure
phenomenon
ARD can't start (1) Check whether the (1) Correction wiring.
Indicator light wiring is correct (2) ARD switch should be ON
(2) The ARD power
switch is closed
After the power (1) Check whether the (1) Connect the internal wiring
outage output connection of the (2) Recharge the battery or replace
ARD can't invert inverter 220V is good. the battery
(2) The battery is too low (3) Please contact the supplier to
(3)The motherboard could replace the new motherboard
be damaged
ARD run time (1) The load is too large. (1) Please replace the high power
output, add load (2) The battery is too low ARD
ARD shut off (3) Overcurrent (2) Recharge the battery or replace
output protection the battery
(3) Please contact the supplier.
Replace the new mainboard
- 10 -
Power failure relief installation
The general
See selection table
standard
overloading)
voltage 3P AC230V/AC380V±15%
The power input
Frequency 50HZ Or 60HZ
normal 3P AC230V/AC400V±15%
The power voltage
Power outages See selection table
output
Rated current See selection table
temperature 0℃ 〜45 ℃
environment
humidity 30%〜90%
- 11 -
Power failure relief installation
ARD Selection list (1P AC220V output) Ladder type with emergency operation
function.
Charging
27.5V 55V 55V 55V
voltage
Charging
0.75A 0.75A 1A 1A
current
The output 1P AC230V 1P AC230V 1P AC230V 1P AC230V
voltage
50H 50H 50H 50H
Frequency
(60Hz) (60Hz) (60Hz) (60Hz)
power <=7.5KW <=11KW <=15KW <=22KW
Size (mm) 380*105*490 410*155*510 410*155*510 460*190*540
ARD Selection list (1P AC380V output) Ladder type with emergency operation
function.
Charging
27.5V 55V 55V 55V
voltage
Charging
0.75A 0.75A 1A 1A
current
1P 1P 1P 1P
The output AC400V±15 AC400V±15 AC400V±15 AC400V±15
voltage % % % %
- 12 -
Power failure relief installation
ARD Selection list (3P AC230V output) Ladder type with emergency operation
function.
ARD Selection list (3P AC380V output) Ladder type with emergency operation
function.
- 13 -