Вы находитесь на странице: 1из 2

Continental PST marine

Injector type
BK2Q-9K546-AG
Reference Number
Old Grading Data
New Grading Data
Date and Time 01/07/2019 14:38:33

Calibration
Test comments ford ranger#num#2

Electrical
Parameter Min. Max. Value Units Status
Capacitance 0.75 2.1 1.36 μF

Flush

Purge
Parameter Min. Max. Value Units Status
Pressure 1584 1616 1598 bar
Response 0 0 401 µS
Delivery 0 0 60.15 mm3/st
Back leak flow 0 0 7.3 mL/min

TP1
Parameter Min. Max. Value Units Status
Pressure 1584 1616 1599 bar
Response 304 456 401 µS
Delivery 55.61 63.73 60.1 mm3/st
Back leak flow 0 80 36.3 mL/min

TP2
Parameter Min. Max. Value Units Status
Pressure 1386 1414 1400 bar
Response 292 438 396 µS
Delivery 37.17 42.72 39.36 mm3/st
Back leak flow 0 55 29.7 mL/min

TP3
Parameter Min. Max. Value Units Status
Pressure 1188 1212 1200 bar
Response 280 420 365 µS
Delivery 1.22 5.65 0.82 mm3/st
Back leak flow 0 45 16 mL/min

TP4
Parameter Min. Max. Value Units Status
Pressure 990 1010 1000 bar
Response 264 396 358 µS
Delivery 7.49 13.06 8.22 mm3/st
Back leak flow 0 45 13.5 mL/min
TP5
Parameter Min. Max. Value Units Status
Pressure 740 760 750 bar
Response 258 386 346 µS
Delivery 5.33 10.13 6 mm3/st
Back leak flow 0 30 8.5 mL/min

TP6
Parameter Min. Max. Value Units Status
Pressure 290 310 302 bar
Response 0 0 0 µS
Delivery 2.51 6.66 3.96 mm3/st
Back leak flow 0 30 3.8 mL/min

Static leak
Parameter Min. Max. Value Units Status
Pressure 990 1010 1000 bar
Response 0 0 0 µS
Delivery 0 0 0 mm3/st
Back leak flow 0 30 8.2 mL/min

NOP
Parameter Min. Max. Value Units Status
Injector pressure 57 157 0 bar
Delivery 0.2 2 0 mm3/st

Grading code

Sv = 4.00 : T v = Issue-11 : F p = A262A902 : F v = 1.25 : Rv = 1.05 : Lv = 2.06 :