TAQA NEYVELI POWER CO. PVT. LTD.

1 x 250 MW Lignite Fired Power Plant


Uthangal, Cuddalore, Tamil Nadu
MANDATORY SPARES - Electrical Date: 10th May 2019
Total Price
Description Quantity to be supplied
Sl.No. in INR

415 V Bus Duct (FOR EACH TYPE, MAKE AND RATING OF


1
415V BUS- DUCT)
1 Bus support insulator 15 Sets. each type and rating 40,100
3 Rigid joint with hardware 05 Nos. each type and rating 13,367
Copper/Aluminum flexible for main run and tap offs bus ducts with
3 1 Set of each type and rating per phase 13,367
hardware
3 Seal off bushing for main run and tap offs bus ducts 1 Set of each type and rating per phase 13,367

2 Jumpers( if applicable) 2 Set. of each type 13,367

2 Rubber bellow for main run and tap offs bus ducts with hardware 1 Set of each type and rating 13,367

2 Silica gel breather 1 No. 26,733

2 6.6 kV Switch Gear (FOR EACH MAKE, TYPE, RATING OF 6.6 KV SWITCHGEAR)
2 Breaker Complete Pole assembly with vacuum interrupter 2 set (1 set consists of 3 nos.) of each rating 2,67,333

20% (rounded off to the next higher integer) of total nos.


2 Aux. Switch assembly, limit switch etc. with complete mechanism. or minimum 5 nos. whichever is higher for each type and 66,833
rating

20% (rounded off to the next higher integer)of total nos.


2 Spring Charging Motor or minimum 5 nos whichever is higher for each type and 2,67,333
rating used in each switchgear.

10% (rounded off to the next higher integer)of total nos.


2 Shunt trip coil or minimum 10 nos. whichever is higher for each type 13,367
and rating used in each switchgear.

10% (rounded off to the next higher integer) of total nos.


3 Closing Coil or minimum 10 nos. whichever is higher for each type 13,367
and rating used in each switchgear.

3 Current transformer of each type, rating & ratio 3 nos of each type, , rating & ratio 40,100

3 Potential transformer of each type & ratio 1 no of each type & ratio 13,367

3 Relays (Other than numerical relay) 20,050

3 each type & rating (anti-pumping relay also included) 1 no of each type & rating 26,733

2 Numerical relays of each type 1 no. 26,733

2 Aux. relays & Lock out relays & TIMERS 2 nos of each type &rating 40,100

2 Interposing relay for PLC each type 1 no. 26,733


2 Check synchronizing relay 1 no. 6,683
2214 Timer each type 1 no. 6,683

20% (rounded off to the next higher integer) of total nos.


2 Vacuum Interrupter with moving and fixed contact assembly or minimum 5 nos. whichever is higher for each type and 40,100
rating used in each switchgear.

2 Bus seal-off bushings 2 nos of each type 2,673

10% (rounded off to the next higher integer)of total nos.


2217 Bus bar support insulators 8,020
for each type and rating used in each switchgear

10% (rounded off to the next higher integer) of total nos.


Limit switches along with mechanism of each type FOR Service and
2 or minimum 5 nos. whichever is higher for each type and 26,733
Test position
rating
2 Closing spring 20% of total no. of breakers 6,683
2 Tripping spring .20% of total no. of breakers 6,683
2 Breaker Control switches 3 nos of each type. 8,020
2 Selector switches 8,020
2 Selector Switch( Local/Remote) 3 nos of each type. 8,020

2224 Selector switches (Switch gear / Trial / Normal Switch) 3 nos of each type. 26,733

2 Ammeter Selector Switch 3 nos of each type. 4,010


2 Voltmeter Selector Switch 3 nos of each type. 4,010

Isolation switch for the control supply (AC Supply On / Off Switch, DC
2 3 nos of each type. 7,352
Supply On / Off Switch, Motor Heater On /Off Switch etc.)
2 Operating mechanism rod for each rating 3 nos
2 Set of gaskets of each rating 2 sets 21,387
2 Ammeter of each type & range 2 no of each type & range 5,347
2 Voltmeter of each type & range 1 no of each type &range 5,347

10% of total nos. or minimum 5 nos whichever is higher


2 Circuit breaker aux. contact assembly:- 33,417
for each type and rating used in each switchgear

2 Indicating LampsClustered type LED of each type/ colour 10% of total number 5,347

2 MCB of each type & rating 5 nos of each. 6,683


2 Fuses of each type and rating 20 Nos. 5,347

2 Maintenance tools and accessories for maintenance (bidder to list) 1 set. 13,367

2 Breaker jaw contact (Bus -end & breaker- end) assembly 2 sets (1 set consists of 3 nos.)of each rating 53,467

2 Non-disconnecting type Terminal blocks 5 nos. of each type and rating 26,733

2 Disconnecting type terminal block for CT wiring 5 nos. 26,733

2 Multiple pin plug contact assy. with cables (male & female) 5 sets 6,683

2 Guide for moving contact set 6 sets (complete) 16,040


2 Interphase barrier 3 nos. for each type 8,020
2 Contactors with HRC fuses 10 % (rounded off to the next 9,357

10 % (rounded off to the next higher integer) of each type


2 Aux. contactors 13,367
and rating

2 Control supply transformers (If applicable) 1 no of each type. 6,683

2 Dash pot complete assembly 1 no. with each type 6,683


2 Surge Arrester 5 nos. of each type and rating 26,733
2 Transducer 2 nos. for each type and Rating 26,733
2 Energy Meter 1 no of each type and rating 13,367
5 HT fuse of PT 3 nos. of each type and rating 8,020

415V System
6.6/0.415KV Transformer (for Each make, type and rating of
3
Transformer)

3 Door Limit Switch complete set 1 set (1 set means total requirement for one Transformer) 66,833

3 CTs of each type and rating 1 no of each type and rating 26,733
3 Temperature scanner 1 no. 2,67,333

3 Thermistor & Temperature surveillance unit 2Sets. 66,833

4 HV Bushing with metal parts, connectors and gaskets 3 No 2,00,500

4 LV Bushing with metal parts, connectors and gaskets 3 No 80,200

4 LV neutral Bushing with metal parts, connectors and gaskets 1 No 26,733

2 sets (1 set means total requirement for one


4 Support Insulator 66,833
Transformer)

4 Limb of complete LT & HT of temperature sensing devices 1 Set (1 set means total requirement for one Transformer) 2,67,333

3 Winding temperature indicating equipment 1Set (1 set means total requirement for one Transformer) 2,67,333

4 PCC (To be repeated for each type & rating)

4 Main power contact (Fixed and moving) Complete assembly 2 sets of each make, type and rating 1,33,667

4 Auxiliary contact assembly of breaker


a. Test position 3 sets of each type 26,733
b. Service position 3 sets of each type 26,733
4 Closing and tripping coil 3 nos. of each type 26,733
4 Spring charging motor 2 nos. of each type 26,733
5 Arc chute for CBs 5 nos. of each type 26,733
5 Arching contacts (for fixed) 3 nos. of each rating 26,733
5 Arching contacts (for moving) 3 nos. of each rating 26,733
5 Main bus bar supporting insulators 10 nos. of each type 26,733
5 Dropper bus bar supporting insulators 5 nos. of each type 26,733
4 CTs 3 nos. for each type and ratio 26,733
4 PTs 3 nos. for each type and ratio 26,733
4 Meters
a. Voltmeter 2 nos. of each type 5,347
b. Ammeter 2 nos. of each type per board 5,347
4 Numerical Protection relays 1 no. of each type per board 8,020
4 Auxiliary relays 2 nos. of each type per board 5,347
4 Interposing relays 2 Nos. of each type 13,367
4 Check synchronizing relay 1no 6,683
4 MCB 1no. of each rating 6,683
4 Timers 2 nos. of each type per board 26,733
4 Misc. items
a. Push button with contact element 5 nos. of each type 13,367
b. Selector switch 5 nos. of each type 13,367
c. Voltmeter selector switch 5 nos. of each type 13,367
d. Ammeter selector switch 5 nos. of each type 13,367
e. Local-remote selector switch 3 nos. of each type 16,040
f. Indicating lamp of LED (LVGP type) 10 nos. 13,367
g. Terminal blocks 10 nos 13,367
h. Breaker Test/Service limit switch 5 sets for each type 26,733
i. Power and control circuit fuses 10 nos. of each type 13,367
j. Control Transformer 1 no. each rating 26,733

5 PMCC (To be repeated for each type & rating)

5 Sliding Main power contact (Fixed and moving) Complete assembly 2 sets of each make, type and rating 2,67,333

5 Auxiliary contact assembly of breaker


a. Test position 3 sets of each type 70,843
b. Service position 3 sets of each type 53,467
5 Closing and tripping coil 3 nos. of each type 53,467
5 Spring charging motor 2 nos. of each type 80,200
6 Arc chute for CBs 5 nos. of each type 26,733
6 Arching contacts (for fixed) 3 nos. of each rating 26,733
6 Arching contacts (for moving) 3 nos. of each rating 26,733
6 Main bus bar supporting insulators 10 nos. of each type 26,733
6 Dropper bus bar supporting insulators 5 nos. of each type 26,733
5 CTs 3 nos. for each type and ratio 26,733
5 PTs 3 nos. for each type and ratio 26,733
5 Meters
a. Voltmeter 2 nos. of each type 13,367
b. Ammeter 2 nos. of each type per board 5,347
5 Numerical Protection relays 1 no. of each type per board 13,367
5 Auxiliary relays 2 nos. of each type per board 8,020
5 Interposing relays 2 Nos. of each type 2,673
5 Check synchronizing relay 1no 8,020
5 MCB 1no. of each rating 8,020
5 Timers 2 nos. of each type per board
5 Misc. items
a. Push button with contact element 5 nos. of each type 13,367
b. Selector switch 5 nos. of each type 13,367
c. Voltmeter selector switch 5 nos. of each type 13,367
d. Ammeter selector switch 5 nos. of each type 13,367
e. Local-remote selector switch 3 nos. of each type 13,367
f. Indicating lamp of LED (LVGP type) 10 nos. 13,367
g. Terminal blocks 10 nos 13,367
h. Breaker Test/Service limit switch 5 sets for each type 13,367
i. Power and control circuit fuses 10 nos. of each type 13,367
j. Control Transformer 1 no. each rating 13,367

5 Electronic overload relays with single phase preventors 1 no. of each type 26,733

5 Auxiliary relay 2 nos. of each type 8,020

5 Indicating Lamp assembly (LED LVGP type) 10 nos. of each type & colour 13,367

5 Phase sequence meter 2 nos. 1,33,667


5 MPCB 1 no of each type and rating 1,06,933
5 MCCB 1 no of each type and rating 1,06,933

5 Single phase control transformer 1 no. of each type 1,337

5 Interposing relay 1 no. of each type 8,020


5 Push button with contact element 1 no. of each type 13,367
5 Meters 1 no. of each type 13,367

6 MCC (To be repeated for each type & rating)


6 Bus bar support insulators 10 nos. of each type 1,33,667
6 Current transformers 1no. of each type & rating 26,733
6 Potential transformers 415/110V 1 no. 26,733
6 Male contact of ACB (main and aux.) 1 set 5,347
7 Female contact of ACB (main and aux.) 1 set 5,347
7 Limit switch of ACB 3 nos. 8,020
7 Spring charging motor of ACB 3 nos. 13,367
7 Closing coil of ACB 2 nos. 8,020
7 Tripping coil of ACB 2 nos. 6,683
6 Breaker control switch 2 nos. 6,683
6 Numerical Protection Relays 1no. of each type 6,683

6 Electronic overload relays with single phase preventors 1 no. of each type 13,367

6 Auxiliary relay 2 nos. of each type 6,683


6 Indicating Lamp assembly (LED LVGP type) 10 nos. of each type & colour
6 Phase sequence meter 2 nos. 2,27,233
6 MPCB 1no of each type and rating 26,733
6 MCCB 1no of each type and rating 26,733

6 Single phase control transformer (415/110V) 1 no. of each type 2,673

6 Interposing relay 1 no. of each type 13,367


6 Push button with contact element 1 no. of each type 10,693
6 Meters 1 no. of each type 26,733

ACDB/PDB/LDB/SLDB/Auxiliary PDB/Distribution Panels (To be


7
repeated for each type & rating)
7 Bus bar support insulators 3 nos. of each type 3,20,800
7 MCCB / SFU 2 nos. of each rating 26,733
7 MCB 2 nos. of each rating 26,733
7 Control switch 2 nos. of each type 26,733

DC Starter Panel ( For each type and rating of DC


8
motor/equipment)
8 DC Power Contactor
a. Power Contactor Complete Assembly 1 no for each make, type and rating NA
b. Power Contactor spare kits 1 no for each make, type and rating NA
c. Power Contactor Coils 1 no for each make, type and rating NA
8 Switch Fuse Unit Complete assembly 1 no for each make, type and rating NA
8 Fuse 5 nos for each make, type and rating NA
8 Selector Switch 1 no for each make, type and rating NA
9 Push Button 1 no for each make, type and rating NA
9 Timer 1 no for each make, type and rating NA
9 Ammeter 1 no for each make, type and rating NA
9 Voltmeter 1 no for each make, type and rating NA
9 Overload Relay 1 no for each make, type and rating NA
8 Transducer 1 no for each make, type and rating NA
8 Aux. Relay 1 no for each make, type and rating NA
8 Control Contactor NA
8 Control Contactor complete 1 no for each make, type and rating NA
8 Control Contactor spare kits 1 no for each make, type and rating NA
8 Control Contactor Coils 1 no for each make, type and rating NA
8 Variable resistor 1 no for each make, type and rating NA
8 Indicating Lamps complete assembly NA
a. Red 1 no for each make, type and rating NA
b. Amber 1 no for each make, type and rating NA
c. Green 1 no for each make, type and rating NA

9 Protective Relaying system


a. 11KV PROTECTIVE RELAYING SYSTEM- NUMERICAL TYPE

Incomer Protection Relay 2 no. for each make, type and rating 5,34,666

Transformer Protection Relay 2 no. for each make, type and rating 2,67,333

Motor Protection Relay 2 no. for each make, type and rating 2,67,333

Out-going feeders Relay 2 no. for each make, type and rating 2,67,333

Bus PT & Line PT Relay 2 no. for each make, type and rating 2,67,333

3.3 KV PROTECTIVE RELAYING SYSTEM-NUMERICAL


b.
TYPE
Incomer Protection Relay 2 no. for each make, type and rating NA
Transformer Protection Relay 2 no. for each make, type and rating NA
Motor Protection Relay 5 no. for each make, type and rating NA
Out-going feeders Relay 2 no. for each make, type and rating NA
Bus PT & Line PT Relay 2 no. for each make, type and rating NA

c. 415V PROTECTIVE RELAYING SYSTEM- NUMERICAL TYPE


Incomer Protection Relay 2 no. for each make, type and rating 2,00,500

Transformer Protection Relay 2 no. for each make, type and rating 2,00,500

Motor Protection Relay 2 no. for each make, type and rating 2,00,500

Out-going feeders Relay 2 no. for each make, type and 2,00,500

Bus PT & Line PT Relay 2 no. for each make, type and rating 66,833
10 NOT USED

11 Actuator

2Nos. for each type, make and rating, 1 no. for H2 cooler
11 Complete set of Actuator Temperature controller and 1 no. for stator water 1,33,667
temperature controller

11 Power Unit for Modulating Actuator 4Nos. of each type 26,733


11 DC-DC Power Pack Unit 4Nos. of each type 26,733
11 Electronic cards 4Nos. of each type 13,367
12 Position Feed Back Transmitters 4Nos. of each type 13,367
12 Control Unit 4Nos. of each type 13,367
12 Limit Switch Assembly 2 Nos each type and rating 13,367
12 Torque Switch Assembly 2 Nos each type and rating 13,367
12 Power Contactor 5Nos. for each type and rating 13,367
11 Auxiliary Contactor 5Nos. for each type and rating 13,367
11 Thermal Over Load Relay 2Nos. for each type and rating 66,833
11 Motor 1No. each type and rating 2,67,333
11 Complete Seal kit 2Sets for each type and rating 26,733
11 Complete O-Ring Set 2Sets for each type and rating 26,733

12 Illumination
12 Fittings 2 sets of each type 10,693
12 Lamps (LED Type) 10 nos. of each type 13,367

12 MCCB 5 Nos for each make, type and rating . 26,733

12 MCB 20 Nos for each make, type and rating . 26,733

13 Control gear box complete 5 sets of each type 42,773

13 Switches 5 Nos for each make, type and rating . 6,683

13 Timer/photo cell (wherever applicable) 2 nos 20,050

13 Receptacles with plug 5 Nos for each make, type and rating 26,733

13 Lighting Transformer 1 no for each make, type and 26,733


rating .

13 Cable
13 11KV Grade HT Power Cable 2 (Two) Kms. of each type, size & rating of Cables 53,46,660

13 3.3KV Grade HT Power Cable 2 (Two) Kms. of each type, size & rating of Cables NA

2(Two)Kms of each type, size


13 LT Power Cable 26,73,330
& rating of Cables
2(Two)Kms. of each type, size
13 Control Cable 21,38,664
& rating of Cables
14 Fire Survival Cable 1(One)Km of each type, size & rating of Cables 16,03,998

14 Neutral Grounding Registor


14 NGR complete with all accessories 1 set of each make, type and rating NA
14 Insulator 2 nos for each make, type, rating and size NA
14 Neutral CT( if applicable) 1 no of each type and rating NA
15 DG Set
15 Diesel Engine NA
15 Element Corrosion Resistor 8Nos. 26,733
15 Element lub oil Filter 8Nos. 66,833
15 Element lub oil by pass Filter 8Nos. 66,833
16 Element Fuel Filter 16Nos. 66,833
16 Plate corrosion Resistor 16Nos. 66,833
16 Element Air cleaner outer 2Nos. 66,833
16 Element Air cleaner Inner 2Nos. 66,833
16 Fuel Oil Pump 1No. 1,06,933
15 Turbo-charger 2Nos. 66,833
15 Engine - starter Motor 1No. 1,06,933
15 Lub Oil Pump 1No. 66,833
15 Injector 2Nos. 40,100
15 Piston rings & liner set 16Nos. 1,33,667

15 Cooler Pump with motor (complete assembly) 1No. 66,833

15 V-belt for radiator fan 6 Nos. 53,467


15 Alternator and Control panel
a. Rotating Rectifier complete set with diodes, varistors . 1 set. 6,683

b. DG Set Controller complete set 1 no 6,683


c. current transformers 2 no of each type and rating 6,683
d. set of instruments of each range One (1) 6,683
e. set of relays of each type One (1) 6,683
f. set of timers One (1) 6,683
g. sets of indicating light One (1) 6,683
h. sets of fuses of each rating One (1) 6,683
i. set of terminal blocks One (1) 6,683
j. Exciter PCB 2Nos. 6,683

15 AMF Panel
a. Protective relay 1 No of each type 26,733
b. Auxiliary relay 2 No of each type 40,100
c. Timer 1 No of each type 13,367
d. Meters 1 No of each type 13,367
e. Transducer 1 No of each type 26,733
f. Selector Switch 1 no of each type 13,367
g. Control Switch 1 no of each type 13,367
h. Current transformer(if applicable) 1 no of each type and rating 13,367
i. Power and Aux. Contactor 1 no of each type and rating 13,367

j. Converter/Solid state potentiometer complete set 1 no of each type 26,733

k. Level Controller complete set 1 no of each type 26,733


l. Push button complete set 1 no of each type 13,367
m. Temperature Scanner 1 no. 93,567
n. Annunciation window 1No. 13,367
o. Indicating Lamps complete assembly 2 Nos of each type. 13,367
16 NOT USED
Motor
17 6.6 KV Motor

Motor of each type and rating (Note : motors covered in mechanical 10% of the installed quantity or minimum 1 number
17 13,36,665
spare items need not to be included here again) whichever be higher

17 Neutral End Terminal Bushing with Fasteners 1 no. for each type and rating of Motor 5,34,666

17 Bearing Temperature Gauge Driving & Non-Driving End 1 set for each type and rating of Motor 8,01,999

17 Phase segregated terminal boxes 2 Nos. for each type and rating of Motor 10,69,332

18 Heaters 2 sets for each type and rating 6,68,333

18 Complete Set of Coupling 1 set for each type and rating of Motor 1,33,667

18 Bearings (DE) for each type and rating of motors 2 sets for each type and rating of Motor 3,60,900

18 Bearings (NDE) for each type and rating of motors 2 sets for each type and rating of Motor 5,34,666

18 Cooling Fan Internal & External 1 set for each type and rating of Motor 10,69,332

17 Neutral CT for differential protection (For motor rating >1000 KW) 2 no of each type and rating. 2,67,333

17 End Termination kits 2 Nos. of each type and rating 5,34,666

Indicating Instruments/gauges other then Bearing temperature gauge


17 1 set for each type and rating of Motor 8,01,999
(as applicable)

17 Phase side Bushing and Insulator 1Set for each type and rating of Motor 1,06,933

17 Oil Seal Ring (as applicable) 1Set for each type and rating of Motor 66,833

18 415 Volt Motor

Motor of each type and rating (Note : motors covered in mechanical


10% of the installed quantity or minimum 1 number
18 spare items need not to be included here again) 10% of the installed 2,00,500
whichever be higher
quantity or minimum 1 number whichever be higher

18 End Shield Cover Driving & Non-Driving End 1 set for each type and rating of Motor 40,100

18 Heaters 2 sets for each type and rating of motor 40,100

18 Bearings (DE and NDE) for each type and rating of motor 2 sets 80,200

19 Cooling Fan for all type and rating of LT motors One (1) set 53,467

19 Dust seals and gaskets for each type of motors 1 Set 26,733

19 Motor Terminal Block 1 no. for each type and rating of Motor 26,733

19 Complete Set of Coupling 1 set for each type and rating 66,833

19 DC Motor
Motor of each type and rating (Note : motors covered in mechanical 10% of the installed quantity or minimum 1 number
19 NA
spare items need not to be included here again) whichever be higher
19 Carbon brushes 2 sets for each type and rating of Motor NA
19 Brush assemblies 2 sets for each type and rating of Motor NA
19 Terminal blocks 1 set for each type and rating of Motor NA
19 Heaters 1 set for each type and rating of Motor NA
20 Complete Set of Coupling 1 set for each type and rating of Motor NA
20 Bearings (DE and NDE) for each type and rating of motor 1 set for each type and rating of Motor NA
20 Cooling Fan 1 set for each type and rating of Motor NA
20 Local Control Station
20 Local Control Station Complete Set for all type of drives 2 nos for each make, type and rating 40,100

20 Push button complete set 5 nos for each make, type and rating 12,698

Sub. Total - B 3,12,91,328