Вы находитесь на странице: 1из 17

APCPCWM_4828539:WP_0000003WP_0000003

APCPCWM_4828539:WP_0000003WP_000000

A Products Code B - 107


B Network solution & S/W Date 2012-12-12
C Installation materials
D
E
Marketing materials
PDB
TECHNICAL Publisher
E-mail
Solution Control Team
jjongmin.lee@lge.com
F Manual(SVC,Install,Owners)
G
H
Competitors & products
Installation&Field engineering
BULLETIN Product

1 PM,SE
ACP
2 MKT
J Regulation & Standard Distribute
3 CAC Team 4 R&D
K Others

ACP (PQCPA11A0 or PQCPB11A0) SW Version : 4.05.3m


Applied Date 12th. December. 2012 ~

Summary

■ ACP v4.05.3m Release

Information
▶Model: ACP (PQCPA11A0 or PQCPB11A0)

▶S/W Version : 4.05.3m


▶ Main Improvements
1. Control & Monitor the AWHP, AHU
- AWHP Max. unit : 256
- AHU Max. unit : 16
2. Interworking with AC Manager Plus
3. Prevent the power data loss when the electricity is off

▶Caution
Do not update except the following purposes
- For interworking with AC Manager Plus
- For control the AWHP
- For control the AHU without AC Manager
- For monitor the PDI data
.
APCPCWM_4828539:WP_0000003WP_0000003
APCPCWM_4828539:WP_0000003WP_000000

ACP SW Release note

No. Information Category Description


1 Date 2012-12-12

ACP (PQCPA11A0 or PQCPB11A0)


2 Product
SW Version : 4.05.3m

3 Region Global
4 Software File Name ACP_upgrade_Softwore_eng.zip
access_nand.o
access_nand_new.o
access_nand_old.o
ACP_upgrade(English)_120227.ppt
5 Package Contents
serviceTool_v3.5.jar
pwrdist_recover
ramdisk-4.05.3m-48MB-acp.gz
zImage.v05
Changes from v3.30.6k
1)Change the way of login
2)Can change the password of Super user
3)Control & Monitor the Eco V DX, AWHP, AHU
4)Change the way of setting schedule
5)Change the way of setting the peak control
(Elimination the Taget Power control, only use the
Taget Operating Rate)
6)Monitor the cycle data of ODU (supported Multi-V
Super3, or later)
6 Version Description / Overview 7)Change the way of setting devices & group
8)Interworking with AC Manager Plus
(will be launched soon)
9)Change the format of power data
10)Can control the cycle of ODU (supported Multi-
V Super3, or later)
11)Emergency Stop
12)Address Locking Function
13)To prevent the power data loss when the
electricity is off.

7 Known Issues / Caveats Not supported

8 Prerequisites / Dependencies PDI Field

9 Installation Instructions Refer to ACP_upgrade(English)_120227.ppt


APCPCWM_4828539:WP_0000003WP_0000003
APCPCWM_4828539:WP_0000003WP_000000

Information

1. Change the way of login

For the first login, selecting “Super User” and setting password to ‘digital21’.

<3.30.6k>

<4.05.3m>
APCPCWM_4828539:WP_0000003WP_0000003
APCPCWM_4828539:WP_0000003WP_000000

Information

2. Can change the password of Super user

For the security reason, you can change Super-User password.


* In any case, you cannot change ID.

<Warning> If you forget the password, you cannot login before doing ID initializa-tion on
ServiceTool)
APCPCWM_4828539:WP_0000003WP_0000003
APCPCWM_4828539:WP_0000003WP_000000

Information

3. Control & Monitor the Eco V DX, AWHP, AHU

ACP Web provides ‘Auto Screen Changer’.


To select all devices, ACP Web provides [Dag & Drop] instead of [Select All] button.

<3.30.6k>

<4.05.3m>
APCPCWM_4828539:WP_0000003WP_0000003
APCPCWM_4828539:WP_0000003WP_000000

Information

4. Change the way of setting schedule

On the version 4.05.3m, ACP Web provides event type scheduler.

Ex) 1. Every Week / Mon ~ Fri / 12:00 / Operation : Off / Lock : On


2. Every Week / Mon ~ Fri / 13:00 / Lock : Off
3. Every Week / Mon ~ Fri / 08:00 / Operation : On / Set Temp. : 26℃

<3.30.6k>

<4.05.3m>
APCPCWM_4828539:WP_0000003WP_0000003
APCPCWM_4828539:WP_0000003WP_000000

Information

5. Change the way of setting the peak control

We do not provides ‘Target Power’ setting anymore. Because ACP calculated and estimated
the power usage based on running time and IDU/ODU spec, so it’s not accurate data.

<3.30.6k>

<4.05.3m>
APCPCWM_4828539:WP_0000003WP_0000003
APCPCWM_4828539:WP_0000003WP_000000

Information

6. Monitor the cycle data of ODU control

ACP Web provides monitoring for ODU cycle information.


When you clicks [Refresh] button, ACP Web displays the current cycle data. It might take
maximum 1 minute.
(Up to Multi-V Super3 provides cycle information)

<4.05.3m>
APCPCWM_4828539:WP_0000003WP_0000003
APCPCWM_4828539:WP_0000003WP_000000

Information

7. Change the way of setting devices & group

Separate ‘Device Setting’ and ‘Group Setting’ menu.


ACP Web provides [Drag & Drop] to edit devices when moving group to group.
ACP Web provides ‘Auto Search’ to find all devices. (Using only for the first installation)
Please, checking the detail edit method in manual.

<3.30.6k>

<4.05.3m>
APCPCWM_4828539:WP_0000003WP_0000003
APCPCWM_4828539:WP_0000003WP_000000

Information

8. Interworking with AC Manager Plus

ACP supports a function of connecting ACP and AC Manager Plus from ACP S/W version
4.05.3m.

< AC Manager Plus >


APCPCWM_4828539:WP_0000003WP_0000003
APCPCWM_4828539:WP_0000003WP_000000

Information

9. Change the format of power data

<3.30.6k>

<4.05.3m>

ACP changed the way of accumulated power usage.


When exporting energy data, energy data is converted to Excel file.
APCPCWM_4828539:WP_0000003WP_0000003
APCPCWM_4828539:WP_0000003WP_000000

Information

10. Can control the cycle of ODU

In this version, ACP provides two type of ‘Peak Control’.

Peak Control
1) Air Conditioner Sequence Control
2) ODU Cycle Control(new)

<4.05.3m>
APCPCWM_4828539:WP_0000003WP_0000003
APCPCWM_4828539:WP_0000003WP_000000

Information

11. Emergency Stop (Fire Alarm)

ACP provides Fire Alarm function.


After connecting the fire sensor to ACP DI1, if the fire sensor detects fire, it stops the
operations of all connected equipments except the Chiller.

[Caution] Fire Alarm interface


•To use the Fire Alarm function, fire sensor needs to be connected to ACP DI1.
• Please refer to each fire sensor product manual for detail usage of fire sensors.

When you press the ‘SET’ button of the ACP, menu screen will be displayed.
Use up and down (▲, ▼) buttons to select [Contents], and press ‘SET’ button again.
While [FireAlarm] is selected, if you press ‘SET’ button, you can set whether to use the Fire
Alarm.0
APCPCWM_4828539:WP_0000003WP_0000003
APCPCWM_4828539:WP_0000003WP_000000

Information

12. Address Locking Function

1. Use Guide

※ When you check the box it will be operated.

2. How to do when PCB IDUs are changed.

(Warning)
To change IDU addresses, you should uncheck “Indoor Address Lock” and
click [Save & Send].

To use this function, you should check devices are supported or not.
APCPCWM_4828539:WP_0000003WP_0000003
APCPCWM_4828539:WP_0000003WP_000000

Information

13. To prevent the power data loss when the electricity is off

ACP backup power data every 1 hours. If a power supply is out during update, there is possibility
to fail the backup process. The problem of power usage does not accumulate after fail is reported.
In this S/W version 4.05.3m, we restore power usage data as last succeed even after the data
backup is fail.
APCPCWM_4828539:WP_0000003WP_0000003
APCPCWM_4828539:WP_0000003WP_000000

Appendix

Appendix 1. DB Download

1. Set the information of ACP what you want to down DB.


- Ver. And IP
2. Click the DB Upload Button.
3. Set the path (folder).

As-is To-Be

odu_info.db, sch_pat.db, sch_info.db, sch_except.db 1. path : in the ‘DBbackup’ folder


: We don’t use it anymore after 3.30.6k verstion. 2. File Information
- 1st Copied PDI File : pwr_dist.db
(save it every 1 hour in Flash)
- 2nd Copied PDI File : pwr_dist_new.db
If pwr_dist.db file is fine,
the file is optimized except hourly accumulated energy data.
- Device&Group File : grp_info.db
- Schedule File : schedule.db
- Error History : errhistory.db
APCPCWM_4828539:WP_0000003WP_0000003
APCPCWM_4828539:WP_0000003WP_000000

Appendix

Appendix 2. Matters that require attention


1. You can change Super User(admin) password from now.
However, if you can not log in after update with Super User / digital21, using [Init Account] button
on Service Tool to initialize your account information.

When the account is initialized, you can see info like this.
Role : 1(Admin), 0(User)
Grant : Granted control groups (999 means all groups)

Super User log in fail.

2. Every time before you work, please backup ACP DB.

3. If your ACP doesn’t have energy DB Zip function (pwr_dist compact), It is mandatory.