IV-H Series
Rockwell
Control Logix
CONTENTS
Rockwell
Control Logix
1756-L61 is used to
create this setting guide
Rockwell
Control Logix
Ethernet cable
OP-87457
Signal Color
I/O cable
OP-87440 24V Brown
24VDV Power supply
0V Blue
2
CHAPTER 3 Settings for Communication
Use the Ethernet cable OP-87457 to connect Select “Advanced” “Environmental” “Field
1 IV to your PC 4 Network”, and set the “Protocol” to “EtherNet/IP”
2 Start IV-Navigator
3
CHAPTER 4 Basic Setting [RSLinx]
This operation would be necessary only once.
For the following sample, the IP address of the PLC is set to 192.168.0.100
1 Connect the PC installed with RSLinx and 1756-E2NT with 8 Click [OK].
Ethernet cable
5 Click [OK].
6 Input the IP address of the PLC (192.168.0.100) to [Station 0], 11 Input the IP address of IV (“192.168.0.103”) to [Station 1],
and then click [Add New]. and click [Add New].
7 Select [EtherNet/IP Driver], and then click [Add New]. 12 IV would be recognized like below.
4
CHAPTER 5 Basic Setting [RSLogix]
Use [RS Logix 5000] and communicate cyclic with IV.
1 Open [RSLogix 5000]. 5 Register the module used for Ethernet/IP communication.
(At this sample, select [1756-EN2T] inside [Communications],
and click [OK].
6 Input the module name (“Ethernet”) inside [Name], and input the
IP address (“192.168.0.100”) inside [IP Address], and click [OK].
5
CHAPTER 5 Basic Setting [RSLogix]
The setting for [Connection Parameters] depends on the setting of [Comm Format].
If [SINT(8bit)] or [DINT(32bit)] is selected, refer to below.
If [SINT(8bit)] is selected.
If [DINT(32bit)] is selected.
* When setting [Comm Format] and [Connection Parameters] please confirm carefully
the specification of your sensor.
If this is not set properly, it might not operate correctly.
6
CHAPTER 5 Basic Setting [RSLogix]
Input Data
Output Data
* If the switch on ControlLogix is set to [Run], the [Download] button could not be
clicked.
Please select [REM] or [PROG].
7
SAFETY INFORMATION
Please visit: www.keyence.com Please read the instruction manual carefully in
order to safely operate any KEYENCE product.
The information in this publication is based on KEYENCE’s internal research/evaluation at the time of release and is subject to change without notice. WW11-1037
Company and product names mentioned in this catalogue are either trademarks or registered trademarks of their respective companies.
Copyright © 2017 KEYENCE CORPORATION. All rights reserved. IVHControlLogix-WW-TG-GB 1029-2 600N30