CONNECTION GUIDE

IV-H Series

Rockwell
Control Logix
CONTENTS

CHAPTER 1 Used Products


CHAPTER 2 How to Connect
CHAPTER 3 Settings for Communcation
CHAPTER 4 Basic Setting [RSLinx]
CHAPTER 5 Basic Setting [RSLogix]

CHAPTER 1 Used Products


Please prepare the following products.

Contact probe Power IO cable Ethernet cable


Ethernet cable / hub
IV-H Series OP-87440 (2m) OP-87457(2m)

Rockwell
Control Logix

1756-L61 is used to
create this setting guide

CHAPTER 2 How to Connect


OVERALL CONNECTION DIAGRAM
Connect the ControlLogix and the IV series as shown below.

IV-H Series Ethernet hub

Rockwell
Control Logix
Ethernet cable
OP-87457

Signal Color
I/O cable
OP-87440 24V Brown
24VDV Power supply
0V Blue

2
CHAPTER 3 Settings for Communication
Use the Ethernet cable OP-87457 to connect Select “Advanced”  “Environmental”  “Field
1 IV to your PC 4 Network”, and set the “Protocol” to “EtherNet/IP”

IV-H Series PC (IV-Navigator installed)

Ethernet Cable OP-87457

2 Start IV-Navigator

Double click the icon of IV-Navigator 5 Set the IP address of IV (“192.168.0.103”).


on your desktop.

3 Select “Network Connection” and connect to IV-H

Please be sure that your PC’s IP address is fixed, and the IP


address of IV-H is initialized (“----”).
Please refer to the Users Manual for the way how to initialize
the IP address.

3
CHAPTER 4 Basic Setting [RSLinx]
This operation would be necessary only once.
For the following sample, the IP address of the PLC is set to 192.168.0.100

1 Connect the PC installed with RSLinx and 1756-E2NT with 8 Click [OK].
Ethernet cable

2 Open [RSLinx Classic].

3 Select [Configure Driver].

9 Select [Windows Default], and then click [OK].

4 Click [Ethernet devices], and click [Add New].

10 Right click [AB_ETH-1, Ethernet], and then select [Configure Driver].

5 Click [OK].

6 Input the IP address of the PLC (192.168.0.100) to [Station 0], 11 Input the IP address of IV (“192.168.0.103”) to [Station 1],
and then click [Add New]. and click [Add New].

7 Select [EtherNet/IP Driver], and then click [Add New]. 12 IV would be recognized like below.

4
CHAPTER 5 Basic Setting [RSLogix]
Use [RS Logix 5000] and communicate cyclic with IV.

1 Open [RSLogix 5000]. 5 Register the module used for Ethernet/IP communication.
(At this sample, select [1756-EN2T] inside [Communications],
and click [OK].

2 Select [New] inside [File], and create a New Project.

6 Input the module name (“Ethernet”) inside [Name], and input the
IP address (“192.168.0.100”) inside [IP Address], and click [OK].

3 Input a project name (“IV”) inside [Name], and click [OK].

7 If necessary, do the same setting for the other units connected.

8 Register IV as an Ethernet/IP module.


4 Right click [1756 Backplane, 1756-A4], and then select [New Module]. Right click [1756-EN2T Ethernet], and select [New Module].

5
CHAPTER 5 Basic Setting [RSLogix]

9 Select [ETHERNET-MODULE] inside [Communications], 11 Click [OK].


and click [OK].

12 Select [Who Active] inside [Communications].

10 Input the module name (“IV”) to [Name], and input the IP


address of IV (“192.168.0.103”) to [IP Address].
Select [Data-INT(16bit)] at [Comm Format], and input the
following numbers to [Connection Parameters].

The setting for [Connection Parameters] depends on the setting of [Comm Format].
If [SINT(8bit)] or [DINT(32bit)] is selected, refer to below.

If [SINT(8bit)] is selected.

13 Select the connected PLC unit (“00, 1756-L61 LOGIX5561,


IV_2), and click [Go Online].

If [DINT(32bit)] is selected.

* When setting [Comm Format] and [Connection Parameters] please confirm carefully
the specification of your sensor.
If this is not set properly, it might not operate correctly.

6
CHAPTER 5 Basic Setting [RSLogix]

14 Click [Download]. 15 Please confirm that it is in [Run] mode.


Double click [Controller Tags], and display the [Monitor Tag].

Input Data

Output Data

16 You can see the result of the judgment like below.

* If the switch on ControlLogix is set to [Run], the [Download] button could not be
clicked.
Please select [REM] or [PROG].

7
SAFETY INFORMATION
Please visit: www.keyence.com Please read the instruction manual carefully in
order to safely operate any KEYENCE product.

GLOBAL NETWORK CONTACT YOUR NEAREST OFFICE FOR RELEASE STATUS

AUSTRIA CZECH REPUBLIC INDIA MALAYSIA ROMANIA TAIWAN


BELGIUM FRANCE INDONESIA MEXICO SINGAPORE THAILAND
BRAZIL GERMANY ITALY NETHERLANDS SLOVAKIA UK & IRELAND
CANADA HONG KONG JAPAN PHILIPPINES SLOVENIA USA
CHINA HUNGARY KOREA POLAND SWITZERLAND VIETNAM

The information in this publication is based on KEYENCE’s internal research/evaluation at the time of release and is subject to change without notice. WW11-1037
Company and product names mentioned in this catalogue are either trademarks or registered trademarks of their respective companies.
Copyright © 2017 KEYENCE CORPORATION. All rights reserved. IVHControlLogix-WW-TG-GB 1029-2 600N30

Вам также может понравиться