Operational Performance Standard Table The following switch positions shall be selected and the
hydraulic oil temperature shall be maintained as indicated
The standard Performance values are listed in the table below as the preconditions of performance tests unless
below. otherwise instructed in each performance test procedure:
Refer to the Group T4-3 to T4-5 for performance test Engine Control Dial : Fast Idle
procedures. Power Mode : PWR
Values indicated in parentheses are reference values. Auto-Idle Switch: OFF
Work Mode: Digging Mode
Hydraulic Oil Temperature : 50±5 °C (122±9 °F)
T4-2-1
SECTION 4 OPERATIONAL PERFORMANCE TEST
Group 2 Standard
T4-2-2
SECTION 4 OPERATIONAL PERFORMANCE TEST
Group 2 Standard
T4-2-3
SECTION 4 OPERATIONAL PERFORMANCE TEST
Group 2 Standard
T4-2-4
SECTION 4 OPERATIONAL PERFORMANCE TEST
Group 2 Standard
T4-2-5
SECTION 4 OPERATIONAL PERFORMANCE TEST
Group 2 Standard
Overload Relief Pressure MPa (kgf/cm2, psi) (Reference values at 50 L/min) T4-5-14
Boom Lower, Arm Roll-In, Bucket Roll-In 39.2+1.0-0
(400+10-0, 5680+145-0)
Boom Raise, Arm Roll-Out, Bucket Roll-Out 39.2+1.0-0
(400+10-0, 5680+145-0)
Main Pump Flow Rate L/min Refer to T4-2-6. T4-5-16
Swing Motor Drainage L/min T4-5-24
With constant speed 0.2 to 0.5
With the motor relieved (2 to 5)
Travel Motor Drainage L/min T4-5-26
With the track jacked up Less than 10 Allowable limit: 10
With the motor relieved Less than 15 Allowable limit: 15
T4-2-6
SECTION 4 OPERATIONAL PERFORMANCE TEST
Group 2 Standard
fNOTE:
B 14.7 (150, 2130) [210 (55.4)]
Refer to T4-5-16.
C 16 (163, 2320) 196±6 (51.7±1.58)
D 22.0 (224, 3190) [134 (35.4)]
E 26.0 (265, 3770) 116±6 (30.6±1.58)
F 34.3 (350, 4970) 79±10 (20.8±2.64)
The valve indicated in parentheses is only a reference
valve.
A
L/min B
MPa (kgf/cm2) P
T178-04-05-001
T4-2-7
SECTION 4 OPERATIONAL PERFORMANCE TEST
Group 2 Standard
L/min
C
MPa (kgf/cm2) Pi
T178-04-05-002
T4-2-8
SECTION 4 OPERATIONAL PERFORMANCE TEST
Group 2 Standard
1. Checking Method
T4-2-9
SECTION 4 OPERATIONAL PERFORMANCE TEST
Group 2 Standard
ECF
Item Reference Measured Value Remarks
Value First Second Third Average
Directed Engine Speed (min-1)
No load 1900
When relieving arm roll-in 2000
Actual Engine Speed (min-1)
No load 2050
When relieving arm roll-in 2000
EC Sensor Voltage (V) 3.29
EC Motor Position (step) 353
T4-2-10
SECTION 4 OPERATIONAL PERFORMANCE TEST
Group 2 Standard
MC
Item Reference Measured Value Remarks
Value First Second Third Average
Demand Engine Speed (min-1)
Fast Idle 1900
Fast Idle (When operating a control 2000 When relieving boom
lever) raise
Fast Idle (Travel HP Mode) 2100 When relieving travel
Fast Idle (ECO Mode) 1850 When relieving boom
raise
Auto-Idle 1150
Slow Idle 800 Pilot shut-off lever:
LOCK position
Actual Engine Speed (min-1)
Fast Idle 2050
Fast Idle (When operating a control 2000 When relieving boom
lever) raise
Fast Idle (Travel HP Mode) 2100 When relieving travel
Fast Idle (ECO Mode) 1850 When relieving boom
raise
Auto-Idle 1300
Slow Idle 950 Pilot shut-off lever:
LOCK position
T4-2-11
SECTION 4 OPERATIONAL PERFORMANCE TEST
Group 2 Standard
T4-2-12
SECTION 4 OPERATIONAL PERFORMANCE TEST
Group 2 Standard
T4-2-13
SECTION 4 OPERATIONAL PERFORMANCE TEST
Group 2 Standard
T4-2-14
SECTION 4 OPERATIONAL PERFORMANCE TEST
Group 2 Standard
T4-2-15
SECTION 4 OPERATIONAL PERFORMANCE TEST
Group 2 Standard
T4-2-16
SECTION 4 OPERATIONAL PERFORMANCE TEST
Group 2 Standard
Wiper/Light Controller
Item Reference Measured Value Remarks
Value First Second Third Average
Wiper 1 Input (V) 2.5 Wiper/washer switch:
INT. position
Wiper 2 Input (V) 2.5 Wiper/washer switch:
INT. position
T4-2-17
SECTION 4 OPERATIONAL PERFORMANCE TEST
Group 2 Standard
(Blank)