Вы находитесь на странице: 1из 4

Client: Mrs.

Sanjeev verma,Prianka verma

PLOT No.JGE-LTV-A-B29
SWIMMING POOL STRUCTURAL DESIGN DUBAI
JUMEIRAH GOLF ESTATES,DUBAI,UAE

TRENDS
POOL&LANDSCAPING LLC
Design Constants
Self Weight of Earth or Soil (W) 18000 N/m3:
Angle Internal friction of earth fill (ø) 30º :
Self BearingCapacity of Soil (very hard) 18000N/m² :
Certificate of Friction between Soil
and concrete (µ) : 0.5
Using M40 Grade of concrete
Compressive Strength of concrete
(¬cbc) : 13 N/mm²
Modular Ratio (M) : 7.17
Using High yield strength Bar
Tensile Strength of steel¬st 230 N/mm²:
Co efficient of active Earth Pressure
1/3
(ka) :
Self weight of concrete 25000 N/m³
:
Self weight of water 10000 N/m³
:
Coefficient of moment of Resistance R 0.91 :
Pool Size - 6m x 3m (maximum), Depth - 1.05 m to 1.65 m
Thick of wall/ floor - 200mm, Covering Block - 40mm
SL MAGNITUDE OF LOAD IN
DESCRIPTION OF LOAD DIST OF CG FROM D IN 'M' MOMENT AT D IN M
NO "N"

1 Self weight of Stem wall 0.2 X 1.65X 25000 = 8250/- 0.2/2 = 0.10 825

2 Self weight of Heel Slab 3.4 X 0.2 X 25000 = 17000/- 3.4/2 = 1.7 28,900

3 Self weight of Water over Heel Slab 3X 1.65 X 10000 = 49500 3/2 =1.5 74,250

Total Vertical Load (€ W) 74750 N Total Moment (Mr) 74250 NM

1
a) Check Against Overturning :

Horizental Earth pressure on the full


height of Retaining
wall tendency to overturn the wall
Passive Earth Presssure Ph 1/2 X Wh² X ka
:
1/2 X 18000 X 1.65² X 1/3=8167.5N
This will acting at h/3 = 1.65/3=0.55 from0.55M
'D' :
Over turning moment Mo Ph X h/3 :
8167.5X 0.55 =4492.125N
Factor of Safety against Verturning Mr/Mo :
74250/4492.125 = 16.52
16.52 > 2
Hence safe Against Overturning
b) Check Against Sliding :
Total Horizental force tendency to slide
the wall
Total force opposing Sliding µ x €W :
Factor of Safety against sliding µ x €W /Ph :
0.5 X 74750/8167.5 = 4.5
4.5 > 1.5
Hence safe Against Sliding
c) Check Against Maximum pressure at 'D'
Mr - Mo = =
74250- 4492.125
= =
69757.8 = =
acting at
Mr - Mo/€W
69757.8/74750
= = 0.93M =
Ecentricity (e ) b/2 - X = =
3/2 - 0.93== 0.4 M =
Intensity of Soil pressure at D (maxi) P1 EW/b (1 + 6e/)b
74750/3.4=(1+6 x 0.5)/3.4
21985 N/m²
=
21985 < 24000 N/m²
which is less than allowable Bearing
capacity of soil
Hence Safe
Intensity of Soil pressure at 'C' (min
pressure)
P2 €W/b ( l - 6e/b)
74750/3.4= (1- 6 x 0.5)/3.4
12932 N/m²
d) Design of Heel Slab:
a) Check for thickness on Depth
Self Weight of Heel Slab 0.2 X3.4X 25000=17000
= N/m²
Acting at h/2 (1.65/2) 0.825 M = =

2
Self weight of Water 3X 1.65 X 10000
= = 49500N/m²
acting at h/2 1.65/2 =0.825
=
Total upward Soil pressure 1/2 (P1 + P2 =) b
1/2 (21985= +12932) 3.4
59358 N.M =

acting at (P1 + 2 X P2/P1


= + P2) X 3.4/ 3
(21985+2x12932)/(21985+12932)x3.4/3
=
1.55 M from
= G

Maximum Bending Moment at 'G'


B.M =
B.M due to down ward pressure
B.M due to up ward pressure
17000
= X 0.825 + 49500X 0.825-
59358 X 1.55
3714
= NM
3714
= X10³ N mm
=

Using 12mm tor Steel Effective depth 'd'√BM /=R X b


=√3714 X 10³ /0.91 X 1000

=64 mm

i) Overall Depth (Covering Block 40mm) 64+ 40 + 6=110


= 110 mm
110mm < 200mm (we given depth) Hence safe
D = 200
Hence effective depth 'd' =110mm

Check for Spacing


ii) Total Area of Steel Ast =B .M/ R X d X √st
3714
= x 10³ / 0.91 X 110 X 230

162mm²
=
12 mmØ Steel bar (area -
113.09X 1000/162
113.09mm2), steel bar Spacing at
698 mm
698 > 200( we given space)

Hence safe
iii) Check for Snear :
V /Tv
bd=
21985/
= 1000 X 110= 0.19 N/mm²
0.18< 0.22 N / mm²
Hence safe
iv) Distribution Bar:
Using 10mm bar
Ast =
1/2 X min. reinforcement as per code
1/2 X 1000 X 0.15/100 X 320
240mm²
=

3
Spacing of Bar 78.53
= X 1000 / 240= 327mm
327>200mm (we are given)
Hence safe
v) Development Length of 'U' Bar (
using 10mm dia)
58
= xØ
58
= X 10 = 580mm (minimum)
We given,
580<600 Shallow end
580<1000 deep end
Hence Safe
e) Design of Stem Wall :
i) Check for thickness or Depth
Height of wall (h) 1.65+0.2=1.85M
=
Maximum BM at 'G' Wh²/6 X 1/3
18000
= X 1.85² /6 X 1/3
3422.5
= NM
Say 3422.5
= X 10³ Nmm
Using 10mm torsteel
Effective depth 'd' √B.M
= /RXb
√3422.5X
= 10³ /0.91 X 1000
Say 61 mm
Overall depth D 61 + =40 +5=106
106mm
=
106 < 200 (we given )
Hence Safe
'd' = 200 - 40 - 40 - 10= 110mm
D = 200mm
ii) Check for spacing of Bar
Ast B.M
= / R X d X st
3422.5X
= 10³ /0.91 X 110 X 230

148 mm²
Using 10mm steel ( Area = 78.5mm² )
Spacing 78.5
= X 1000/ 148=530 mm
817> 200 (we given)
Hence Safe
Result

Gunite(short create) structure 40N/mm2

Gunite mix 460SRC+20kg+0.6kg fibre

Wall/Floor thickness 200mm

covering block 40mm

Reinforcement(Main Bar) 12mm∅ at 200mm c/c (Vertical)

Reinforcement(Distribution bar) 10mm∅ at 200mm c/c (Horizontal)

Supporting Bar 'U'/Chair 10mm at 200mmc/c

U' Bar Length 60cm shallow end at 200 c/c

100cm deep end at 200 c/c