Вы находитесь на странице: 1из 4

PROPOSED EARTH RETAINING STRUCTURE USING

WELLGUARD WALL SYSTEM


+ 68.0
1200 1245

CAPPING BEAM + 66.0


150 mm dia. Sub Soil Drain Wrapped
SANDY SOIL
in Geotextile & Laid To Fall
W23 PANEL

3000
Determined
On Site
(2000)
To Be
+ 63.0
BOUNDARY

Road Pavement

900mm Wide
x 450mm ht.
Tie Beam
PT12 POST

9000

TYPICAL SECTION @ HIGHEST BACKFILL LEVEL


1200
610 225 450 225
150 mm dia. Sub Soil Drain Wrapped
in Geotextile & Laid To Fall

W23 PANEL

To Be Determined On Site
COARSE
AGGREGATE

(2000)
WEEP
BOUNDARY

HOLES

2T16
200 + 63.0

250
3T16
R10 @ 200 Links
1stPOUR

900
PT12 POST

TIE BEAM DETAIL


ALL CONCRETE MIX TO
GRADE C 25/30 (Cube
compressive strength of 30
N/mm2 @ 28 days)
G H

6.00m 40.70m 16.00m


TOW +66.00m
TOW +65.00m TOW +65.00m
BOW +63.00m
BOW +63.00m BOW +63.00m
Wall Height 3.0m
Wall Height 2.0m Wall Height 2.0m
W23 Panels
W22 Panels W22 Panels

63.45 64.00 64.00


63.00 63.00

Datum 60.00m

10.20m 27.80m 18.20m 5.50m

0.50m
62.70m

Elevation Of WellGuard Wall System