Вы находитесь на странице: 1из 4

Company name: -

Created by: -
Phone: -
Fax: -
Date: -

96566576 HYDRO MULTI-E 2 CRE 20-3 50 Hz

H HYDRO MULTI-E 2 CRE 20-3 3* 400 V, 50 Hz


(m) Losses in fittings and valves not included
100 % Q = 19.8 m³/h
98 % H = 34.6 m
n = 98 % / 49.2 Hz
40 switch-on at = 100 %
Pumped liquid = Drinking water
Density = 1000 kg/m³

5 4 3 2 1

30

20

10

25 %
Eta pump = 71.5 %
Eta pump+motor = 59.2 %
0
0 5 10 15 20 25 30 35 40 45 50 55 Q(m³/h)
P
(kW)

P2 = 2.61 kW
0 P1 = 3.15 kW

Printed from Grundfos CAPS 1/4


Company name: -
Created by: -
Phone: -
Fax: -
Date: -
Description Value H 100HYDRO
% MULTI-E 2 CRE 20-3 3* 400 V, 50 Hz
Product name: HYDRO MULTI-E 2 CRE 20-3 (m) 98 % Losses in fittings and valves not included
Product No: 96566576 Q = 19.8 m³/h
EAN number: 5700830314593 H = 34.6 m
5 4 3 2 1 n = 98 % / 49.2 Hz
Technical: 30
switch-on at = 100 %
Actual calculated flow: 21 m³/h Pumped liquid = Drinking water
Min flow system: 0 m³/h Density = 1000 kg/m³
Max flow: 44 m³/h 20
Actual calculated flow: 22 m³/h
Resulting head of the pump: 34.6 m
10
Head max: 57 m
Curve tolerance: ISO 9906 Annex A 25 % Eta pump = 71.5 %
Pump name: CRE20 Eta pump+motor = 59.2 %
0
Number of pumps: 2 0 5 10 15 20 25 30 35 40 45 50 Q(m³/h)
Stages: 3 P
(kW)
Installation:
Maximum operating pressure: 10 bar
Maximum inlet pressure: 10 bar 4
Cut-in pressure PE: 3 bar 2 P2 = 2.61 kW
Cut-out pressure: 3.6 bar 0 P1 = 3.15 kW
Flange standard: DIN 2999-1
Pump inlet: DN 80
Pump outlet: DN 80
Pressure stage: 10

Liquid:
Pumped liquid: Drinking water 1 2

Liquid temperature range: 0 .. 70 °C

1365
Electrical data:
907

Mains frequency: 50 Hz
Rated voltage: 3 x 400 V, PE
Start. method: electronically
150

Rated current: 18 A
Enclosure class (IEC 34-5): 54 700,00 950
Radio interference supression: IEC/CISPR 11-1B 1134

Controls:
Control type: ME

Tank:
Volume of pressure tank: 33 l
Diaphragm tank: Yes

Others:
Basis plant: Y
L1 L1
Gross weight: 222 kg
Shipping volume: 0.88 m3 L2 HFI/FI L2
Language: GB L3 L3
Product range: International
PE

Product name: 50 l diaphragm tank


Product No: 00ID6175 CONTROL CABINET

EAN number: 5708601033544

Installation:
Maximum operating pressure: 10 bar

Tank:
Volume of pressure tank: 50 l

Printed from Grundfos CAPS 2/4


Company name: -
Created by: -
Phone: -
Fax: -
Date: -

96566576 HYDRO MULTI-E 2 CRE 20-3 50 Hz


Input Sizing result
Select Application Type HYDRO MULTI-E 2
Pressure boosting CRE 20-3
Overview mode No Tank 83 l
Select Application Area Supply 3x400 V, PE
Quantity * Motor 2 * 4 kW
Commercial
buildings Flow 19.8 m³/h ( max. -5 %)
Switch-on at 100 %
Your Requirements H total 34.6 m
Allowed undersize 10 % Power P1 3.15 kW
Discharge pressure p 3 bar Power P2 2.61 kW
Flow (Q) 22 m³/h Eta pump 71.5 %
Max. liquid temperature 25 °C Eta motor 82.8 %
Min. liquid temperature 20 °C Eta pump+motor 59.2 % =Eta pump * Eta
Pumped liquid Drinking water motor
Suction lift 4m Flow total 24144.8 m³/year
Tank outlet above booster set No Flow per pump 11 m³/h
Control Mode Nom. pressure 10 bar
Constant Pressure, Max.pressure 3.1 bar =during operation
Speed Control in the load profile
Allow fixed speed No Inlet pressure -0.7 bar .. 5.68 bar (against
Variable speed Yes atmosphere)
Spec. energy 4.76 Wh/m³/m
Edit Load Profile consumption
Consumption Q1 22 m³/h 0.1615 kWh/m³
Consumption Q2 16.5 m³/h Energy consumption 3899 kWh/Year
Consumption Q3 12.1 m³/h Price On request EUR
Consumption Q4 7.7 m³/h Energy cost 585 EUR /Year
Consumption Q5 2.64 m³/h Price + energy costs On request EUR /15Years
Load profile Standard profile
Operation hours per day 9 h/day Be aware that the flow is more than 5 % below the requested
Period Day duty point.
Time T1 0.41 h/day
Time T2 0.82 h/day H
HYDRO MULTI-E 2 CRE 20-3 3* 400 V, 50 Hz
Time T3 1.23 h/day
(m) 100
98 %
%
Losses in fittings and valves not included
Time T4 2.45 h/day
Time T5 4.09 h/day 40
Configuration
Membrane tank size (to be calculated) 5 4 3 2 1
ON/OFF-band 20 %
30
Of these: number of standby pumps 1
Preferred design Booster sets
Tank required on the discharge side Yes
Total number of pumps 2
20
Velocity limitation No
Operational Conditions Q = 19.8 m³/h
Ambient temperature 20 °C H = 34.6 m
Frequency 50 Hz 10 n = 98 % / 49.2 Hz
Max. operation pressure 10 bar switch-on at = 100 %
Min. power limit for SD start 5.5 kW Pumped
25 % liquid = Drinking
Eta pump
water
= 71.5 %
Phase 1 or 3 Density = 1000 kg/m³
Eta pump+motor = 59.2 %
Voltage 1 x 230 or 3 x 400 V 0
0 5 10 15 20 25 30 35 40 45 Q(m³/h)
Hit list settings P
Calculation period 15 years (kW)
Energy price 0.15 EUR/kWh
Evaluation criterion Price + energy costs 6
Increase of energy price 6%
Max. hits per product group 2 4
Max. hits total 8
2
P2 = 2.61 kW
0 P1 = 3.15 kW

Printed from Grundfos CAPS 3/4


Company name: -
Created by: -
Phone: -
Fax: -
Date: -

96566576 HYDRO MULTI-E 2 CRE 20-3 50 Hz


Load Profile
1 2 3 4 5
Flow 90 75 55 35 12 %
Head 100 100 100 100 100 %
P1 3.15 2.69 2.16 1.19 0.397 kW
Time 149 299 448 896 1493 h/Year
Energy consumption 470 803 967 1066 593 kWh/Year
Quantity 1 1 1 1ES 1ES

Printed from Grundfos CAPS 4/4