INDUSTRIAL DEHUMIDIFIER
FVB-Jr SERIES
FVB DEHUMIDIFIER-SERIES WITH FLUTED VERTICAL BEDS (ROTOR)
ALL FVB-Jr. SERIES UNITS HAVE THE FOLLOWING OUTSTANDING FEATURES
High efficiency and reliability Easy to operate
* A totally self contained unit * Suitable for continuous operation
* Robust structural steel frame construction * Auto / manual selector switch.
* CNC fabricated unit(s) with powder coated finish * Reactivation cool down safety device.
* Highest moisture removal efficiency at lowest energycost * Digital display of status, faults, waring, and
* In-built heat recovery segment within rotor media. temperature RH/ display options
* Air intakes thru EU-3 grade leak tight filters * Volume control dampers for both (P&R) air flow
* Multiple choice of reactivation heat source:- Easy to install
electrical, steam, thermic fluid, direct/indirect fired gas * Versatile, easy to package and handle
* Easy addition of pre/after cooler, higher grade filter * Small footprints; low volume/weight per CMH
* In-built process bypass for custom designing of process Easy to maintain
air flow or process tempreture control * Quick and easy to service
* Rotor incorporates robust internal structure with * Rotor is water washable
perimeter flange for industrial quality and durability. * Easy, tool-free access to all major components
* Rotor perimeter flange extends media and seal life * Quick serviceability and maintenance free operation
* Rotor is non-flammable with organics < 2%. Options
* Hard face coating on rotor edge ensures long life and * Humidity control by humidistat on/off
good sealing for media and seals. * Stainless steel construction
* Process and reactivation air flow sectors are insulated
* Unique PTFE bonded bulb seal design;minimized air leakage
,
,
3
,
,
1
1
8
166 1,930
800
250
4
REACTIVATION AIR OUTLET
340x 244 W/40
732 FLANGE AND FILTER
300
2
1
1
1
1
1
4
3
FLANGE AND FILTER
550 240
1,100
1,100
OVERLOAD
REACT. IN DB° C (DEFALULT) TRIPPED
REACT. OUT DB° C
PROCESS. IN DB° C
PROCESS OUT DB° C
SYSTEM ON PUSH
TO READ PROCESS IN RH % (OPTIONAL)
PROCESS OUT RH % (OPTIONAL)
HEATER ON
AUTO
PROCESS AIR OUT
THERMOSTAT
BLOCKED FILTER
OPTIONAL TRIPPED
REACT. AIR IN
MANUAL
PROCESS FAN
REACT AIR OUT ON
REACT FAN
ON BED DRIVE
ON BED DRIVE
FAILURE
BLOCKED FILTER
PROCESS AIR IN OPTIONAL
AUXILIARY ON
30°C
0.5 4
15°C
0
2 4 2
10°C
0
0 2 4 6 8 10 12 14 16 18
00
0 Example :-
-4
FVB
ru
Th
00
15 Model FVB-4000
B-
FV
25 Process air volume = 3200 m3/h
Air volume = 80%
DP (Process) = 23.4 mm w.c.
20
15
50% 60% 70% 80% 90% 100% 110% 120%
1050
FV B - 1 5
00 T
FVB - 400 O
0 REA
900 CT
FVB - 3 0 0 0
FVB - 1 5 0 0 AND F
750 AND F VB -
4 000
VB - PRO
2 100
PRO CE
SS
600 CE
SS
450
300
150
FEATURE OVERVIEW
Items Standard Optional