PATCH' Overhead Model


STRAND CENTURY
zl
ol
tt
-t
)l
PATCH PANEL
ml
rrl
r-l
Custom built for any number of load
al
=l
UI circuits for very large installations.
ol
zl
<l o Plug tip insulated to prevent shock.
ul
ol
o All jacks rated at 50 Amp capacity.
al
ul o Solid brass contact surfaces.
al
..)
o Specially designed counter-weighted
.
(o pulleys retract plug cords automatically. .JF E
:p
nilil
-
-.lF
occ
z)
<F
tz
F LIJ
(/"JO 'li,x,
tifl os o689
9000so
o0n sooo0s
sooooo
€OataoO
@ $tr6sio

oa
m-l
zt
€HHH -l>
c.z

il'
nill
-
-
o)
E

STtrIANtrl
:jy_T_u_"ff"
STRAND CENTURY INC. STRAND CENTURY INC. STRAND CENTURY LIMITED
20 Bushes Lane 5432 West 102nd Street 6334 Viscount Road
Elmwood Park, NewJersey 07407 Los Angeles, California 90045 Mississauga, Ontario, Canada
U.S.A. U.S.A. L4V 1 H3
Tel: (201) 791-7000 (212) 564-6910 Tel: (213) 776-4600 Tel: (416) 677-7130
Telex: 130322 Telex: 653508 Telex:06968646
Strand Century Saf-T-Patch@ Patch Panel Overhead Model
1 Sal-T-Plugs (20 Amp & 50 Amp)
2 Worklights (under hood)
3 50 Amp Saf-T-Jacks
4 Worklight dimmer w/swilch and fuse
5 lnterior light switch and luse
6 Circuit schedule frame
7 Load circuit breakers
8 Hinged access door
I lnput terminals
10 Neutral buss
1'1 Retractable cords & Counterweights
r Contractor'sentryarea
I

T]
tt
ls r-l
tr
Ll

F_ width as req uired __________----{


l-aa, (1118mm) -----

the schedule. Each jack shall be of 50 ampere D. There shall be a boardlight with associated
Specif ications capacity. dimmer which shall evenly illuminate the con-
The cross connect patch panel shall consist of B. The 0.125" (3.2mm) aluminum piug panel trol panel.
a factory finished welded steel free standing shall support an insulating bushing and an E. There shall be a 15 amp 120 volt grounded
assembly containjng all necessary plugs, individual plug and cable for each load circuit. duplex convenience outlet.
jacks and circuit breakers to provide a f lexible Plugs shall be U.L. approved Strand Century F. A circuit schedule and space for a cue
inter-connecting system between load circuits Saf-T-Patcho with solid brass tips. Split tip sheet shall be provided.
and control outputs. The framework shall con- plugs will not be accepted. The plug shall have
sist of welded steel members completely a handle of high impact molded phenolic G. The size of the cross connect panel shall
covered on all exposed surfaces with 0.125" material with circuit identifrcation number en-
notexceed:'98"Hx Wx68"D
(3.2 mm) aluminum panels. Exterior finish (2489 mm H x W x 1727 mm D).
graved at the base; contoured wider at the
shall be baked enamel. base than near the tip. The tip shall be solid H. amp and 50 amp plug
A. The jack panels shall be of 0.125" (3.2 mm) brass with an insulated sleeve to provide 100% and cord sets with associated ci rcu it breakers
aluminum with epoxy finish suitably engraved dead entry. The extra flexible insulated cable of the same rating
-mm shall be provided.
for identification. Jacks shall be Strand Cen- shall be automatically retracted into the board l. l\4atching
-20 receptacle jacks,
- 50 amp capacity
tury Saf-T-Patch@ and U.L. approved, in which when not in use by means of a counterweight- shall be provided as follows:
the contact surface is solid brass and pressure ed pulley. Plug cables shall be of sufficient per 2.4 Kw Dimmer
is maintained by a steel spring. The spring length so that any plug can be connected to
any jack. Each cable shall terminate in a prop-
per 3.6 Kw Dimmer
shall not carry current or create any arc. Split
receptacles will not be accepted. The front of erly identif ied circu it breaker to wh ich the con- per 4.0 Kw Dimmer
the jack shall be an insulating bead which pre- tractor shall connect the load circuit wires. - per 6.0 Kw Dimmer
vents electrical contact except by a plug thrust C. There shall be a circuit breaker panel con- per 7.2 Kw Dimmer
into the jack, the depth of the bead and insu- taining circuit breakers of prope.rsize. ln close per 12 Kw Dimmer
lated portion of the plug tip being such that an proximity to the circuit breakers shall be a
operator cannot receive a shock when insert- neutral bar terminal strip with suff icient screw
- per 20 Amp Non Dim
ing or removing the plug f rom the jack. There lug connections to connect all load neutral per 60,qmp Non Dim
shall be lacks for each dimmer output and for wires. - Total
each constant potential circuit according to -

Copyright 1977 Strand Century Inc


Printed in Canada