Академический Документы
Профессиональный Документы
Культура Документы
Features
General
Design Direct drive servo valve
Actuation Rotary actuator
Size NG06
Mounting interface ISO 4401-03-02-0-05
Ambient temperature (°C) -20 ... +60
Weight (g) 550
Vibration resistance (g) 30 all axis
Hydraulic
Max. operating pressure (bar) 350P,A,B 250 T, with internal drain 350 T, with external drain 250 Y
Fluid Hydraulic Oil DIN 51524 - 535
Fluid temperature (°C) -20 ... +80
Viscosity (cSt) 5 ... 500
Rated flow
(l/min) 6 ... 60
@ Δp=35 bar per control edge
Flow maximum (l/min) 130
1
Leakage at 100 bar (l/min) <1.2
Filtration ISO 4406 (1999) 18/16/13
Static / Dynamic
Step response at 100% step (ms) <3.5
2
Frequency response (±25% signal) (Hz) 300
Hysteresis (%) <0.1
Threshold (%) <0.05
Null shift (%) <0.02
Electrical Characteristic
Supply voltage (V) 22 ... 30
Current consumption max (A) 4.5
Input signal +- 10 V, 4 ... 20 mA
Enable signal (V) +9 ... +28 Pin C
EMC EN 61000-6-2, EN55011:1998+A1
Connector EN 175201 – 804
Frequency Response
Flow Signal
Mounting Pattern
ISO4401-03-02-0-05
P A B T F1 F2 F3 F4
Ø 8.3 Ø 8.3 Ø 8.3 Ø 8.3 M5 M5 M5 M5
x 21.5 12.7 30.2 21.5 0 40.5 40.5 0
y 25.9 15.5 15.5 5.1 0 -0.75 31.75 31
O-Rings
Bolts