Features
General
Design Direct drive servo valve
Actuation Rotary actuator
Size NG10
Mounting interface ISO 4401-05-04-0-05
Ambient temperature (°C) -20 ... +60
Weight (g) 1.5
Vibration resistance (g) 30 all axis
Hydraulic
Max. operating pressure (bar) 350 P, A, B 250 T, with internal drain 350 T, with external drain 250 Y
Fluid Hydraulic Oil DIN 51524 - 535
Fluid temperature (°C) -20 ... +80
Viscosity (cSt) 5 ... 500
Rated flow
(l/min) 50 ... 250
@ Δp=35 bar per control edge
Flow maximum (l/min) 475
1
Leakage at 100 bar (l/min) 3
Filtration ISO 4406 (1999) 18/16/13
Static / Dynamic
Step response at 100% step (ms) ≤7
2
Frequency response (±25% signal) (Hz) >100
Hysteresis (%) <0.2
Threshold (%) <0.1
Null shift (%) <0.5
Electrical Characteristic
Supply voltage (V) 22 ... 30
Current consumption max (A) 4
Input signal +- 10 V, 4 ... 20 mA
Enable signal (V) +9 ... +28 Pin C
EMC EN 61000-6-2, EN55011:1998+A1
Connector EN 175201 – 804
Frequency Response
Flow Signal
Mounting Pattern
P A B T T1 F1 F2 F3 F4
Ø 11.2 Ø 11.2 Ø 11.2 Ø 11.2 Ø 11.2 M6 M6 M6 M6
x 27.0 37.3 16.4 3.2 50.8 0 54 54 0
y 6.3 21.4 21.4 32.5 32.5 0 0 46 46
O-Rings
Bolts