Вы находитесь на странице: 1из 4

L250

The Domin L250 is a single stage DDV which


combines high flow, excellent dynamics, strong
chipshear, and low power consumption.

A single stage valve has the advantage of being


able to position the spool independent of supply
pressure and without wasting high pressure fluid.
The L250 has been designed to sustain high
bandwidth operation at exceptional flows without
significant limitation of operating pressures or duty
cycles.

Where DDVs have been employed to control high


flows there is a clear trade with packaging size and
weight. The L250 valve is packaged to be lower
weight and more compact than the best of EHSVs.
This represents a weight saving of approximately
80% over competitor DDVs.

Features

Rated flow of up to 250 lpm (at 70 Bar ΔP)


Maximum flow of up to 475 lpm
Bandwidth of >100 Hz (-3 dB, up to ± 25% FS)
Chipshear capability of >700 N
Low power consumption of <10 W at rated flow
Valve mass 1.5 kg
Defined spool position at power-down optional
Spool position feedback

Web www.domin.co.uk Tel +44 (0)1761 252650 Email info@domin.co.uk


1
L250

General
Design Direct drive servo valve
Actuation Rotary actuator
Size NG10
Mounting interface ISO 4401-05-04-0-05
Ambient temperature (°C) -20 ... +60
Weight (g) 1.5
Vibration resistance (g) 30 all axis
Hydraulic
Max. operating pressure (bar) 350 P, A, B 250 T, with internal drain 350 T, with external drain 250 Y
Fluid Hydraulic Oil DIN 51524 - 535
Fluid temperature (°C) -20 ... +80
Viscosity (cSt) 5 ... 500
Rated flow
(l/min) 50 ... 250
@ Δp=35 bar per control edge
Flow maximum (l/min) 475
1
Leakage at 100 bar (l/min) 3
Filtration ISO 4406 (1999) 18/16/13
Static / Dynamic
Step response at 100% step (ms) ≤7
2
Frequency response (±25% signal) (Hz) >100
Hysteresis (%) <0.2
Threshold (%) <0.1
Null shift (%) <0.5
Electrical Characteristic
Supply voltage (V) 22 ... 30
Current consumption max (A) 4
Input signal +- 10 V, 4 ... 20 mA
Enable signal (V) +9 ... +28 Pin C
EMC EN 61000-6-2, EN55011:1998+A1
Connector EN 175201 – 804

1) Axis cut valve


2) Measured with load (70 bar pressure drop / two control edges)

Web www.domin.co.uk Tel +44 (0)1761 252650 Email info@domin.co.uk


2
L250

Step Response Pressure Gain

Frequency Response

Flow Signal

Web www.domin.co.uk Tel +44 (0)1761 252650 Email info@domin.co.uk


3
L250

Mounting Pattern

P A B T T1 F1 F2 F3 F4
Ø 11.2 Ø 11.2 Ø 11.2 Ø 11.2 Ø 11.2 M6 M6 M6 M6
x 27.0 37.3 16.4 3.2 50.8 0 54 54 0
y 6.3 21.4 21.4 32.5 32.5 0 0 46 46

O-Rings

5 pieces ID 12.4 x Ø 1.78


NBR 70 Shore A

Bolts

M6 x 60 DIN EN ISO 4762-10.9


Required torque 13 Nm

Web www.domin.co.uk Tel +44 (0)1761 252650 Email info@domin.co.uk