Вы находитесь на странице: 1из 4

Test Equipment

Test pumps
Type  DA 33 DA 66 DA 118 DA 186 DA-267
3330 psi 6625 psi 11854 psi 18670 psi  26700 psi
Max. pressure 
(230 bar) (457 bar) (817 bar)  (1287 bar) (1841 bar)

Flow at /100 psi inlet / 0 pressure  29 l/min 15,6 l/min  9,3 l/min  6.2 l/min  4,1 l/min

Test pumps
Type DHDA 33 DHDA 66 DHDA 118
6728 psi 13300 psi 23695 psi
Max. pressure
(464 bar) (917 bar) (1634 bar)

Flow at / 100 psi inlet / 0 pressure 31,7 l/min 16,3 l/min. 9,1 l/min.

Test pumps
Type AZ-1-58 AZ-1-86 AZ-1-107

5800 psi 10700 psi


Max. pressure 8600 psi (592 bar)
(400 bar) (738 bar)

Flow at/100 psi inlet / 0 pressure 3,5 l/min 3,03 l/min 1,96 l/min

Tank volume 5 ltr. 5 ltr. 5 ltr.

Type AZ-1-187 AZ-1-275 AZ-1-425


18750 psi 27500 psi (1896 10700 psi
Max. pressure
(1292 bar) bar) (738 bar)

psi
Flow at/100 psi inlet / 0 mottrykk 1,14 l/min 0,72 l/min
(2900 bar)

Tank volume 5 ltr. 5 ltr. 5 ltr.

Hand pumpe for pressure testing 


Type Hi Force 100 Hi Force 150

P max 700 bar 1000 bar

Q max 0,049 litre/stroke 0,049 litre/stroke

Tank volume 10 litre 10 litre


 
Heat Exchanger Test Kit

Name Description   

Dimension : W 250mm, L 460mm, H 250mm / Weight: 15 kg


Type : Curtiss Wright – G-250
 VVT-01
Contents : 1 ea. Air Vacuum Test Gun, 1 ea. T-Handle Support Rod,
2 ea. Support Rod – GSV-S-N 28 – 69” ID

Dimension : B 250mm, L 460mm, H 250mm / Weight: 15 kg


Type : Curtiss Wright – G-250
VVT-02
Contents : 1 ea. Air Injection Test Gun, 1 ea. Plugging Test Gun, 21 ea. Seal and Washer sets, 1 ea. Regulator, 4
ea. Tubing Plugs, 1 ea. Size Sealing Template

Hydraulic dead-weight tester

Name Description   

Dimension : W 490, L 510, H 300mm / Weight: Unit: 22 kg   Weights: 56 kg


Type: Budenberg 580HX Dual range tester
DVT 
Measure range: 1-2000 Bar
Equipment/fuctions: 1 cylinder 1/8"2 measure range, 1 cylinder with  1/160"2 measure range, CD with software
 

Umbilical test-manifold

Name Description   

Dimension : W 394, L 1080, H 300mm / Weight: 30 kg


UTM- Max. temp.: 230˚C
1500- P max.: 21 000 PSI / 1447 bar
XX 
Connection: 10 off. 9/16" Autoclave Female (21G9M)
Available: UTM-1500-01, 02, 03, 04, 05, 06, 07, 08, 09, 10
 
Test jig

Name Description   
Dimension : W, L 4200, H mm / Weight:  kg
Diameter: ID 216mm, OD: 278mm 
Max. temp.: 150˚C
JIG-01 
P max.: 690 bar
Connection inlet top: 11 off. 1/2" NPT Female
Connnection inlet bottom: 3 off. 1/2" NPT Female   

Dimension : W 555, L 2500, H mm / Weight:  kg


Diameter: ID 368,5mm, OD: 404,4mm 
Volume:  266 liter
JIG-03 P max.: 50 bar
Flanges: 1 ea. 16" 300# RF, 1 ea. 16" 1500# SPO
Connection side: 3 ea. 2" NPT Female  

Connection in flange: 1 ea. 2" NPT Female, 1 ea. 1/2" NPT Female  

Additional test equipment

Name Description   

Mechanical pressure- and temperature recorder


 DeWit
Can be use in EX-area

Electric Fuji recorder


FUJI 6ch
Non-Ex
Pressure loggers and manometers can be delivered in the following pressure classes as standard:

2,5 bar                40 bar               250 bar                  1600 bar
6 bar 60 bar 400 bar 2000 bar
10 bar 100 bar 600 bar 2500 bar
25 bar 160 bar 1000 bar 3500 bar