Data Sheet - Design Requirement B-84547-DY-MM2-DSR-ST-20-0001 Rev.1A
Mechanical Data Sheet Inlet Separator (20MBD-301)
Dayung Compression 2 (DC-2) Project
ConocoPhillips (Grissik) Ltd. Page 2 of 10
REVISION SHEET
ConocoPhillips (Grissik) Ltd.
Printed initials in the approval boxes confirm that the document has been signed.
The originals are held within Document Management.
Mechanical Data Sheet for Inlet Separator (20MBD-301)
1 COMPANY : CONOCOPHILLIPS (GRISSIK) LTD. DOC NO. : B-84547-DY-MM2-DSR-ST-20-0001 Rev: 1A
2 PROJECT : DAYUNG COMPRESSION 2 (DC-2) PROJECT SHEET NO. : 4 OF 10
3 DESIGN DATA
6 DESIGN CODE ASME Sect. VIII Div. 1 Latest Edition PAINTING (INTERNAL) N/A
8 CONSTRUCTION CATEGORY ASME CODE STAMPED + MIGAS SHOP HYDROTEST PRESS. (N & C) Yes (ASME VIII, Div 1 Sect. UG-99(b))
21 VISCOSITY cP 0.0156 BASE PLATE & SLIDING PLATE SA 516 Gr 70 N / Teflon slide plates
29 VOLUME FLOWRATE, (Note 3) BPD 1,344 ANCHOR BOLT / NUTS SA-307 B CL-2 / SA 563-A (Hot Dip Galvanized)
30 MASS FLOWRATE, (Note 3) lb/hr 18,478 MATERIAL IMPACT TEST RQD. YES (PER CODE & SPEC.)
36 PRESSURE VESSEL DIA (ID) inch 76" VORTEX BREAKER YES (316L SS)
39 CONSTRUCTION
40 SHELL THICKNESS (min) inch 2.80 (71mm) + 0.125 (3mm) Clad 316L SS TYPE OF HEADS Hemispherical
41 SHELL THICKNESS (nom) inch 2.80 (71mm) + 0.125 (3mm) Clad 316L SS TYPE OF SUPPORT Saddle
42 HEAD THICKNESS (min) inch 1.38 (35mm) + 0.125 (3mm) Clad 316L SS PLATFORM/LADDER/PIPE CLIP Yes
43 HEAD THICKNESS (nom) inch 1.54 (39mm) + 0.16 (4mm) Clad 316L SS INSULATION SUPPORTS N/A
52 CORROSION ALLOWANCE inch 0 / (Cladding 316L SS) FIELD TEST lbs 119770 (54327 kg)
61
Dayung Compression 2 (DC-2) Project
4 Mark No. Size. Rating Facing Type Schedule CL To Flange Face Description Remarks
6 N1 1 16 600 # RF WN-SR 25 mm Thk. 4'-9" (1450mm) Gas Inlet C/W Inlet Device
7 N2 1 16 600 # RF WN-SR 25 mm Thk. 4'-9" (1450mm) Gas Outlet C/W Mist Extractor
37 NOTES
40 3) Vendor to confirm that fabrication, inspection and testing shall follow the referenced Codes, Standards, and Project Specification.
42 5) This Data Sheet shall read together with Process Data Sheet C-84519-DY-PP0-DSR-ST-20-0002. & P&ID C-84519-DY-PP0-PID-ST-20-0003.
43 6) All vessel parts directly exposed to the fluid shall be NACE MR 0175 certified.
45 8) Gasket shall 0.175" thick flexitallic style CGI, spiral wound, fleible graphite filled, 316 SS Windings, per ASME B 16.20.
48 11) Refer to Company Specification Doc. No. ID-N-BU-MM0-STS-GN-00-0001 Preparation and Painting.
52 - Vortex Breaker
53 13) Require a minimum 6 inch between LSHH and bottom of mesh pad (LSHH-BOV = 3'-6")
54 14) Manway to be supplied c/w Davit, Cover, Gasket and Stud Bolts/Nuts.
55 15) All internal shall be bolted to support welded to the vessel and all internals shall be sectionalized to pass through manway for installation and removal ( max. Weight 55 lbs).
56 16) Vendor to provide all required data for MIGAS and ASME U-Stamp certification.
57 17) Preliminary sizing has assumed a pv2 of 4000 lb/ft.s2 for Inlet nozzle and 2500 lb/ft.s2 for Gas outlet nozzle are met. Vendor to optimise (see Process Data Sheet)
58 18) Water outlet nozzle shall be sized for 2300 bpd. Preliminary sizing has assumed a velocity of 6 ft/s for water outlet nozzle is met. Vendor to optimise (see Process Data Sheet).
59
Dayung Compression 2 (DC-2) Project
4
5
6
7
N7
8 N12 N6B N5B N4B
9
2 HEMISPHERICAL HEADS
10 LIFTING LUGS (2 SETS) N2 N11 N6A N5A N4A N1 N9
(BOTH SIDE)
11
12
13
14
MIST EXTRACTOR
15 HHLL
16 76" (ID) SCHOEPENTOETER
INTERNAL HANDLE
17 NP HLL CL
M1
18 NLL
19
INT. LADDER RUNG LLL
20
VORTEX BREAKER N17
21
LLLL
22
23 TL TL
24
25 N10 N13 N3 N14 N16 N15 N8
26 : EARTHING LUGS
27
28 5'-19" (1450 mm) 3'-9.27" (1150 mm)
20'-0" T/T
29
30 Note : This sketch is min. indication only
31
32
33 LEVEL DIAGRAM
34
35 HHLL 44"
36
37 HLL 38"
38
39 NLL 24"
40
41 LLL 18"
42
43 LLLL 12"
44
45 Bottom (ID) 0"
46
47
48
49 NOTES (CONT.)
50
51 19) Teflon slide plates shall be provided by vendor.
52 20) Vendorshall be design and supply anchor bolts/nuts. Basering template shall be supplied by vendor for construction purpose.
54 22) Basic wind speed 80 km/hr (23 m/sec) in accordance with the following design codes :
56 - ANSI A58.1-1982 : Minimum Design Loads for Building and Other Structures.
58 24) Nozzle 2 inch and 3 inch shall use SS material (SA 182 Gr. F316L) due to difficulty in applying clad/overlay.
60 26) Material anchor bolts/nuts and structural bolt/nuts : SA 307-B / SA 563-A (Hot Dip. Galvanized).
61
Dayung Compression 2 (DC-2) Project
Printed initials in the approval boxes confirm that the document has been signed.
The originals are held within Document Management.
Mechanical Data Sheet for Inlet Separator (73-V-101/102)
1 COMPANY : CONOCOPHILLIPS (GRISSIK) LTD. DOC NO. : B-84547-DY-MM2-DSR-ST-20-0001 Rev: 1A
2 PROJECT : DAYUNG COMPRESSION 2 (DC-2) PROJECT SHEET NO. : 8 OF 10
3 DESIGN DATA
6 DESIGN CODE ASME Sect. VIII Div. 1 Latest Edition PAINTING (INTERNAL) N/A
8 CONSTRUCTION CATEGORY ASME CODE STAMPED + MIGAS SHOP HYDROTEST PRESS. (N & C) Yes (ASME VIII, Div 1 Sect. UG-99(b))
21 VISCOSITY cP 0.0156 BASE PLATE & SLIDING PLATE SA 516 Gr 70 N / Teflon slide plates
29 VOLUME FLOWRATE, (Note 3) BPD 1,344 ANCHOR BOLT / NUTS SA-307 B CL-2 / SA 563-A (Hot Dip Galvanized)
30 MASS FLOWRATE, (Note 3) lb/hr 18,478 MATERIAL IMPACT TEST RQD. YES (PER CODE & SPEC.)
36 PRESSURE VESSEL DIA (ID) inch 76" VORTEX BREAKER YES (316L SS)
39 CONSTRUCTION
40 SHELL THICKNESS (min) inch 2.80 (71mm) + 0.125 (3mm) Clad 316L SS TYPE OF HEADS Hemispherical
41 SHELL THICKNESS (nom) inch 2.80 (71mm) + 0.125 (3mm) Clad 316L SS TYPE OF SUPPORT Saddle
42 HEAD THICKNESS (min) inch 1.38 (35mm) + 0.125 (3mm) Clad 316L SS PLATFORM/LADDER/PIPE CLIP Yes
43 HEAD THICKNESS (nom) inch 1.54 (39mm) + 0.16 (4mm) Clad 316L SS INSULATION SUPPORTS N/A
52 CORROSION ALLOWANCE inch 0 / (Cladding 316L SS) FIELD TEST lbs 119770 (54327 kg)
61
Dayung Compression 2 (DC-2) Project
4 Mark No. Size. Rating Facing Type Schedule CL To Flange Face Description Remarks
6 N1 1 16 600 # RF WN-SR 25 mm Thk. 4'-9" (1450mm) Gas Inlet C/W Inlet Device
7 N2 1 16 600 # RF WN-SR 25 mm Thk. 4'-9" (1450mm) Gas Outlet C/W Mist Extractor
37 NOTES
40 3) Vendor to confirm that fabrication, inspection and testing shall follow the referenced Codes, Standards, and Project Specification.
42 5) This Data Sheet shall read together with Process Data Sheet C-84519-DY-PP0-DSR-ST-20-0002. & P&ID C-84519-DY-PP0-PID-ST-20-0003.
43 6) All vessel parts directly exposed to the fluid shall be NACE MR 0175 certified.
45 8) Gasket shall 0.175" thick flexitallic style CGI, spiral wound, fleible graphite filled, 316 SS Windings, per ASME B 16.20.
48 11) Refer to Company Specification Doc. No. ID-N-BU-MM0-STS-GN-00-0001 Preparation and Painting.
52 - Vortex Breaker
53 13) Require a minimum 6 inch between LSHH and bottom of mesh pad (LSHH-BOV = 3'-6")
54 14) Manway to be supplied c/w Davit, Cover, Gasket and Stud Bolts/Nuts.
55 15) All internal shall be bolted to support welded to the vessel and all internals shall be sectionalized to pass through manway for installation and removal ( max. Weight 55 lbs).
56 16) Vendor to provide all required data for MIGAS and ASME U-Stamp certification.
57 17) Preliminary sizing has assumed a pv2 of 4000 lb/ft.s2 for Inlet nozzle and 2500 lb/ft.s2 for Gas outlet nozzle are met. Vendor to optimise (see Process Data Sheet)
58 18) Water outlet nozzle shall be sized for 2300 bpd. Preliminary sizing has assumed a velocity of 6 ft/s for water outlet nozzle is met. Vendor to optimise (see Process Data Sheet).
59
Dayung Compression 2 (DC-2) Project
4
5
6
7
N7
8 N12 N6B N5B N4B
9
2 HEMISPHERICAL HEADS
10 LIFTING LUGS (2 SETS) N2 N11 N6A N5A N4A N1 N9
(BOTH SIDE)
11
12
13
14
MIST EXTRACTOR
15 HHLL
16 76" (ID) SCHOEPENTOETER
INTERNAL HANDLE
17 NP HLL CL
M1
18 NLL
19
INT. LADDER RUNG LLL
20
VORTEX BREAKER N17
21
LLLL
22
23 TL TL
24
25 N10 N13 N3 N14 N16 N15 N8
26 : EARTHING LUGS
27
28 5'-19" (1450 mm) 3'-9.27" (1150 mm)
20'-0" T/T
29
30 Note : This sketch is min. indication only
31
32
33 LEVEL DIAGRAM
34
35 HHLL 44"
36
37 HLL 38"
38
39 NLL 24"
40
41 LLL 18"
42
43 LLLL 12"
44
45 Bottom (ID) 0"
46
47
48
49 NOTES (CONT.)
50
51 19) Teflon slide plates shall be provided by vendor.
52 20) Vendorshall be design and supply anchor bolts/nuts. Basering template shall be supplied by vendor for construction purpose.
54 22) Basic wind speed 80 km/hr (23 m/sec) in accordance with the following design codes :
56 - ANSI A58.1-1982 : Minimum Design Loads for Building and Other Structures.
58 24) Nozzle 2 inch and 3 inch shall use SS material (SA 182 Gr. F316L) due to difficulty in applying clad/overlay.
60 26) Material anchor bolts/nuts and structural bolt/nuts : SA 307-B / SA 563-A (Hot Dip. Galvanized).
61