3.1 Introduction
3.2 Cogeneration
Cogeneration is the term used for the combined generation of work and heat. Any
heat engine must reject a lot of heat to the environment, but this energy has no exergy
(i.e. utility) in the ideal heat engine. Practical engines however reject useful heat in the
exhaust gasses and in the cooling circuit, that could be directly used or the engine
modified to provide more useful heat at a small expense in work output.
Efficiencies of cogeneration plants are high, but care must be paid not to mix
work and heat values because we knows that work is usually two or three times more
expensive than heat, i.e. the output should be consistently measured in exergy, so that the,
instead of W+Q, the output value is W+Q(1-T0/T), where T is the temperature at which
heat is delivered.
The useful heat-to-work ratio is around 2. It does not require changes in the power
plant, it is a versatile cogeneration system, and its use is expanding in most industries:
textile, chemical, food. Because the exhaust gasses are relatively hot (some 700 K), it is
suitable for high temperature applications.
The useful heat-to-work ratio is around 7 (suitable for the iron industry, but still
low for the ceramic and glass industry). It directly provides useful vapour, either by
extracting some of it at an intermediate stage in the turbine, or by not expanding to the
low pressures of ambient temperatures but to higher than atmospheric pressures (it is
called a back-pressure turbine), to render the whole turbine outlet vapour useful.
In 1882 Pearl Street Station was the first commercial power plant in the world
which was made by Thomas Edison who had performed the first modern use of energy
recycling. The plant was so designed that produces both thermal energy and electricity.
With energy recycling, the power plant of Edison had achieved an approximate 50% of
energy efficiency.
Now a day, the European Union generates 11% of its entire electricity by using
cogeneration systems. With this, Europe is able to save for their annual energy source.
Apparently, a huge savings difference still exists between the member states within
Europe because of the variations of energy use. The savings range between 2%-60%. The
region of Europe consists of three countries that are included in the world’s list of most
intensive cogeneration economies. These countries include Finland, Netherlands, and
Denmark.
Outside the United States, the use of energy recycling is more universal just like
in Denmark, which is probable the most active energy recycler in the world as the
country obtains about 55% of its energy efficiency from waste heat recovery and
cogeneration. Other huge countries like India, Russia, and Germany also obtain their
energy efficiency from decentralized sources like cogeneration.
On the other hand, there are also other European countries that make great efforts
to increasing their energy efficiency. One of these countries is Germany in which they
reported to have more than 50% of the total electricity demand in the country that is
provided by cogeneration. The United Kingdom is also supporting actively the
combination of power and heat. Their goal is to achieve reduction of 60% in carbon
dioxide before the year 2050 comes.
The Combined-cycle power plants (CCPP) are those which have both gas and
steam turbine supplying power to the network as shown (Figure 3-1). The idea of
combined cycle has grown to improve the efficiency of simple Brayton-cycle by using
heat recovery boilers to capture heat form the exhaust gases of gas-turbine and used to
produce steam to operate Rankine-cycle.
Figure 3-1 Schematic flow diagram of 300MW Combined Cycle Power Plant
(Reproduced from Google Images Website)
As the combined cycle power plant is an integration of steam turbine power plant
and gas/combustion turbine power plant in which the exhaust gases from the gas turbine
are reused for the steam turbine power plant because the gas turbine is relatively high-
temperature machine operated at about 2000 to 3000°F, 1100 to 1650°C whereas the
steam turbine is a relatively low-temperature machine operated at about 1000 to 1200°F,
540 to 650°C Source [Page310 M.M.EI Wakil]. The heat energy in the exhaust gases of a
gas turbine is enough to produce superheated steam from pure water but it also use
supplementary firing lets the plant respond to fluctuations of electrical load i.e on full
load where the exhaust temperature from gas turbine is not enough to operate steam
turbine.
Figure 3-3 Schematic flow diagram of a Simple-Cycle Gas Turbine (Reproduced from
www.CombinedCyclePowerPlants.com)
• Gas Turbine
• Steam Turbine
• Condensers
3.8 Turbines
The turbines are also known as prime movers and it is a one of the steady flow
device which can operate for long time continuously. It consist of numbers of stages of
blades or vans they may be stationary or moving mounted on a shaft known as periphery,
the function of a turbine is to convert the fluid kinetic energy into a mechanical energy.
Turbines are simple but powerful machines that based on Newton’s third law of motion
which states that for every action there is an equal and opposite reaction.
The turbines are available in size from 32 to 173,000bhp and there speed varies from
3600 to 60,000rpm.
3.9.1 Compressor
The various types of compressors are used in gas turbine to decreases the volume
and increases the pressure ratio of air by mechanical means. As the pressure ratio is
increased the air rate firstly decreases to a minimum value (which decreases temperature)
and then starts increasing. With increase of turbine inlet temperature the air rate is
decreased and compressor work increased and the net turbine output is decreased.
1) Centrifugal Compressor
air enter through the eye. The air then flows radially outward through the impellor blades.
After that the air flows through converged passages of diffuser blades and finally the air
flows to compressor outlet or exist. The centrifugal compressors are preferred when the
pressure ratio not more than 4:1 is required
The Axial Compressor consists of a stator which encloses the rotor. Both stator and
rotor are fitted with rings of blades (RB-Rotor Blades, SB-Stator Blade). In this
compressor air flows in an axial direction from inlet to outlet. Air entering at one end and
flows through alternatively arranged rings or blades and get compressed successively.
The axial flow compressors are preferred when the pressure ration more than 6:1 is
required. In the gas turbine power plant of high output and efficiency generally pressure
ratio more than 10:1, therefore to attain such high pressure multi-stage centrifugal
compressor does not prove to be useful as an equivalent axial flow compressor.
In the combustion chamber, combustion of fuel takes place. The combustion chamber
should provide thorough mixing of fuel and air as well as combustion products and air so
that complete combustion and uniform temperature distribution in the combustion gases
may be achieved. Combustion should take place at high efficiency, because the losses
incurred in the combustion process have direct effect on thermal efficiency of the gas
turbine cycle. The combustion chamber should provide sufficient volume and length for
complete combustion of the fuel. The temperature developed inside the combustion
chamber should be at low; this may be achieved by adding satisfactory amount of air to
maintain stable combustion conditions and then introducing secondary air into the
product of combustion for cooling. The sum of primary and secondary air supplied is
total air needed for combustion. Air fuel ratio in the gas turbine is nearly 60:1
Figure 3-4 Schematic flow diagram of a Gas Turbine (Reproduced from Google Images
Website)
Figure 3-5 Schematic flow diagram of a Axial Flow Compressor with Stator and Rotor
Blades (Reproduced from Google Images Website)
The single-shaft turbine has the air compressor, gas-producer turbine, and the
power turbine on the same shaft. They are usually selected when a constant speed drive is
required, as in generator drives, and when the starting torque requires are low. A single-
shaft engine can be used to drive centrifugal compressor, but the starting system and the
compressors match point must be considered.
The split-shaft or dual-shaft turbine has the section required for air compression
on one shaft and the section producing output power on a separate shaft. In a split-shaft
turbine the portion that includes the compressor, combustion chamber, and the first
turbine section is the hot gas producer. The second turbine section is the power turbine.
The split-shaft engines allow for variable speed at full load. It can be started with a high
torque load connected to the power output shaft, and the power turbine can be more
optimally configured to match load requirement.
The steam turbine is that which is operated on steam they are usually impulse type
turbine in which superheated steam from the Heat Recovery Steam Generator (HRSG)
after passing through a row of fixed nozzles impinges on vans or buckets which are
mounted on a periphery with a little or no steam pressure. The vans or blades are
designed in crescent-shaped that extract kinetic energy of fluid i.e. steam and convert it
into mechanical energy.
In the impulse turbine the steam exerts force on the blade due to the velocity of
steam. In this type of turbine the steam is first passed from nozzle so that its velocity
should increase with the drop in pressure and then steam impinges or strikes on the
turbine blades (which are curved like buckets) which are mounted in the form of ring on
shaft.
The action of the jet of steam, impinges on the blades, is said to be an impulse and the
rotation of the rotor is due to the impulse force
In a reaction turbine, the blades sit in a much larger volume of fluid and turn
around as the fluid flows past them. A reaction turbine doesn't change the direction of the
fluid flow as drastically as an impulse turbine: it simply spins as the fluid pushes through
and past its blades.
Figure 3-7 Schematic flow diagram of a Reaction Turbine (Reproduced from Google
image Website)
In the reaction turbine the pressure is reduced in the fixed blades as well as in
moving blades and the velocity of steam is increased in the fixed blades, and is reduced
while passing through the moving blades. While in impulse type turbine the steam is first
passed through nozzle in which velocity of steam is increased at the loss of pressure and
then steam with very high velocity impinges on blade at constant pressure where its
velocity decreases.
Figure 3-8 Schematic flow diagram of Pressure and velocity diagram of a Reaction and
Impulse Turbine (Reproduced from Google Images Website)
The axial flow turbines are those in which the working fluid is injected axial to
the peripheral blades of one or more staged turbine wheel.
The Radial in flow turbines are those in which steam enters through center or eye
of the impeller and exits from the periphery.
A steam turbine with an exhaust steam pressure below atmospheric pressure, such
that steam is directly and completely condensed.
A steam turbine designed to operate with an exhaust steam pressure at any level
that may be required by a downstream process, where all condensing takes place.
The scientist and engineers, working in research centers all over the world,
concentrated their attention to produce more power and to improve efficiencies of these
turbines. They have listed numbers a numbers of methods for this purpose, but the
following are important from thesis point of view.
Thus the above difficulty may be removed by reheating of the steam. In this
system the steam is removed from the turbine when it becomes wet. It is then reheated at
a constant pressure by the flue gases, until it becomes superheated steam. It should be
noted that steam with qualities of less than around 85% to 90% to remain in the turbine is
not allowed. The figure( ) shows bellow the reheating system of steam for steam turbine
in which the steam is first expand in the turbine T-1 from 3-4 and then reheated from 4-5
so that quality may improve and then after it is expanded in the turbine T-2 from 5-6 .
Figure 3-8 Schematic flow diagram of Reheating of steam (Reproduced from Google
Images Website)
Multi-stage steam turbines are those in which expansion of steam takes place into
numbers of stages. The stages may be categories according to fixed and moving blades
and also according to the pressure ranges. As we have already discussed in a two-stage
impulse turbine in which steam after leaving the moving blades is made to flow though a
fixed ring and it impinges on the fixed to the secondary moving rings and then steam is
passed from secondary moving rings to the condenser, it is known as two-stage turbine.
But some time we make the steam to pass through a number of stages in order to get
more work. Such turbine is known as multi-stage turbine. As shown in figure() the steam
turbine with three stages according to the pressure ranges High Pressure, Medium
Pressure or Intermediate Pressure and Low Pressure Turbine.
Figure 3-8 Schematic flow diagram of Multistage Steam Turbine (Reproduced from
Google Images Website)
3.7.2.8.3 Bleeding
The process of draining steam from the turbine, at certain points during its
expansion and using this steam for heating the feed water and then supplying it to the
boiler is known as bleeding. A feed water heater is a simple form of heat exchanger
consists of tubes through which feed water flows. These tubes are surrounded by a
casing, containing the heating steam. The steam condenses and transfers its latent heat to
the feed water. By the bleeding we can avoid wet steam at the end of expansion because
we are draining steam from turbine at about dry saturated vapors point
It consist of high pressure (H.P) and low pressure (L.P) stage in which high
pressure steam from boiler enters the H.P stage of the turbine where it expands and
pressure is reduced to such a value as required for processing work. A part of this low
pressure steam leaving the H.P stage is supplied for processing work while remaining
steam expands further in the L.P stage of turbine. The exhaust steam from the processing
plant and low pressure turbine is considered in a condenser and pumped back to the
boiler.
In this the exhaust from the steam turbine is generally supersaturate which is not
suitable for process work due to following reasons. In this type of turbine the control of
temperature is impossible and the rate of heat transfer from the supersaturated steam is
lower than that of saturated steam Thus, the exhaust supersaturated steam is passed
through a de-superheater to make the steam saturated, and then further processed for
condensation.
Some HRSGs include supplemental because the exhaust from a gas turbine
contains large amounts of excess air. This exhaust has oxygen content close to fresh air,
and will be utilized as preheated combustion air for supplementary fuel firing.
Supplementary fuel firing permits increasing steaming of the waste heat boiler. Hence
increases the output of the steam turbine. Generally, Supplementary fuel firing or duct
firing provides electrical output at lower capital cost. It is therefore often utilized for
peaking operations. Supplementary burners also permit generation when the gas turbine
is out of service.
Emissions controls may also be located in the HRSG. Some may contain a
Selective Catalytic Reduction system to reduce nitrogen oxides (a large contributor to the
formation of smog and acid rain) and/or a catalyst to remove carbon monoxide. NOx
catalyst performs best in temperatures between 650 °F (340 °C) and 750 °F (400 °C)
source [encyclopedia]. This usually means that the evaporator section of the HRSG will
have to be split and the SCR placed in between the two sections. Some low temperature
NOx catalysts have recently come to market that allows for the SCR to be placed
between the Evaporator and Economizer sections (350 °F - 500 °F (175 °C - 260 °C)).
The Superheater Section of the HRSG is used to dry the saturated vapor being
separated in the steam drum. In some units it may only be heated to little above the
saturation point where in other units it may be superheated to a significant temperature
for additional energy storage. The Superheater Section is normally located in the hotter
gas stream, in front of the evaporator.
It is desirable that there should be a close control over the final temperature of
steam over a reasonably wide range of load. The various methods employed to achieve
this are as given.
1) Desuperheater
2) Tilting Burners
Tilting burners in the furnace are used to regulate the temperature of gases
leaving the furnace.
3) Damper
Dampers are provided to control the direction of hot combustion gases in order to
control to vary the quantity of gas passing through superheater.
It is desirable that the water to be used in the boiler should be free from various
impurities. The impure water is chemically treated in different ways depending upon the
nature and concentration of impurities, these water treatment processes are carried under
the supervision of a chemical engineer. The different types of water treatment process are
enlisted bellow which may be carried to remove the various impurities.
1. Mechanical Treatment
2. Thermal Treatment
3. Chemical Treatment
4. Demineralization
5. Blow down
Figure 3-7 Schematic flow diagram of a Heat Recovery Seam Generator (Reproduced
from Google image Website)
3.7.4 Condenser
The condenser is one of the important equipment of a Power Plant. The purpose
of condenser is to condense the exhaust steam from the steam turbine to recover the high-
quality feed water for reuse in the cycle. If the circulating cooling-water temperature in
the condenser is low enough it creates low back pressure (vacuum) for the turbine to
exhaust. This pressure is equal to the saturation pressure that corresponds to the
condensing steam temperature. As we know that, the turbine work per unit pressure drop
is much greater at the low-pressure than the high-pressure at the end of turbine, so by
lowering the back pressure by only a few Psi will increase the work output.
Figure 3-7 Schematic flow diagram of a Heat Recovery Seam Generator (Reproduced
from Google image Website)
Surface Condensers
Direct-Contact Condensers
Surface condensers are the most common types used in power plants. It is much
like heat exchanger which consists of series of tubes and a shell. In which the steam from
exhaust of the steam turbine is allowed to pass through series of tubes where it exchange
its heat with the cold water circulating around the tubes in the shell and get hot, the
The tubes are rolled into the tube sheet at both ends to prevent leakage of the
circulating water into the steam. An expansion joint allows for the different rates of
expansion between the tubes and shell. The tube sheets are usually made of Muntz metal,
which is similar to brass.
Another distribution problem is the result of the undesired unequal steam flow
from the turbine exhaust duct to the condenser tubes. Thus special attention must be paid
to the design of the connection between turbine and condenser called exhaust neck, such
as adding a well-tapered steam dome above the tube bundle to minimize the problem. An
expansion joint is usually provided between the turbine exhaust and the condenser steam
inlet. This permits the condenser to be rigidly mounted on the floor and also to bolt the
condenser directly to the turbine exhaust duct and support it on springs that allow a
certain vertical movement and reduce the strain on the turbine casing.
The condensers are designed one, two, or four cooling-water passes. The numbers
of passes determines the size and effectiveness of a condenser. Four passes condenser are
seldom used in utility installations.
A single-pass tube is that in which cooling water passes through all tubes at once,
from one end to the other end. In this condenser, with the same total number and size of
tubes, i.e. (the same heat transfer area and with the same water velocity), flow of water
requires twice as much water flow but results in half the water temperature rise and thus
lower condenser pressure. Thus such a single-pass condenser is good for plant thermal
efficiency and reduces thermal pollution, but requires more than twice the water and
hence four times the pumping power.
In a two-pass condenser the water enters half the tubes at one end of a divided
inlet water box, passes through these tubes to an undivided water box at the other end,
reverses direction, and passes through the other half of the tubes back to the other side of
the divided water box.
Water boxes are often divided beyond the divisions required by the number of
passes. A divided water box single-pass condenser allows condenser to operate while
other half is being cleaned or repaired. In case of divided two-pass condenser, the water
boxes are divided into four quarters. Divided water boxes have duplicate inlet and outlet
connections, each with its own circulating water circuit. Valves in the division plates
permit back washing by reversing water flow for cleaning purpose.
Figure 3-7 Schematic flow diagram of Single-Pass tube Condenser and Two-Pass Tube
condenser (Reproduced from Google image Website)
As the large power plants usually have two or ore low-pressure turbine sections in
tandem. The condenser may be divided into corresponding sections or shells, situated
below the low-pressure turbine sections. If the turbine exhaust pressure in all sections is
the same, i.e. when the exhaust ducts are not isolated from each other, we would have a
single-pressure condenser. If the exhaust ducts are isolated from each other, these
individual condenser shell pressures will increase because the circulating water
temperature will increase as it flows from shell to shell called multi-pressure condenser.
The main purpose of feed water heater is to improve cycle efficiency by heating
the condensate and feed water before returning it to the steam generator. The heating
could be as high as 400 to 500°F (200 to 260°C) in a fossil-fueled power plant but it is
lower in a water-cooled nuclear-reactor power plant. There are two basic types of feed
water heaters
3.8 Fuel and Fuel System for Combined Cycle Power Plant
The ability to burn almost any combustible fluid is the key advantage of the gas
turbine. Natural gas (CH4) is most preferable fuel than other fuels because it is readily
available, has good combustion characteristics, and is relatively easy to handle. Other
fuel gas include liquefied petroleum gases, which are considered wet at normal gas
turbine operation condition and most a wide range of refinery waste and coal-derived
gases, which have relatively high friction of hydrogen. Both of these features lead to
problem in fuel handling and preparation, as well as in gas turbine operation.
Distillate oil is the most common liquid fuel and used where natural gas is not
available, it is the primarily used as backup and alternative start-up fuel where as the
crude oil and residual are also available in abundant in oil-producing country and can also
be used but it required treatment for sodium salts and vanadium contamination.
A typical fuel gas control system is a two stage system that uses pressure control
in combination with flow control to achieve turndown ration from 60:1 to 100:1.
The Steam turbine which is only operated with the steam formed by heat recovery
steam generator, the heat recovery steam generator may be waste HRSG or it may require
supplementary heating to avoid fluctuation in the quality of steam formed.
The supplementary fuel may be natural gas, fuel oil, or coal. Integrated solar
combined cycle power stations are currently under construction at Hassi R'mel, Algeria
and Ain Beni Mathar, Morocco.
The gas turbine requires an affective lubricating system to overcome the friction
in the rotating parts and to serve the purpose of cooling these elements for that filtered
and cooled lubrication is provided to the gear reducer, gas turbine bearings, and to the
other driven equipments. The lubrication system is carried out by a motor-driven, start-
up/coast-down oil pump, a primary oil pump mounted on and driven by the gear reducer,
filters, an oil reservoir, an oil cooler, and automatic control.
The start-up/coast-down oil pump circulates oil until the gas turbine reaches a
speed at which the primary pump can takeover, Oil filters serves the full flow of the
pumps, The oil reservoir is mounted in the base of the gas turbine and with that cooling
and heating system is also provided to get required viscosity of lubricating oil due to
climate change.
Starting system can be pneumatic, hydraulic, or electric motor starter. All systems
uses a one way clutch to couple the starter motor to the gas engine so that as the engine
accelerates above the start speed, the starter can shut down.
Unlike the combustion turbine, steam turbine do not require auxiliary starting
system, Steam turbines are stared through controlled opening of the main steam valve,
which is controlled by governing system. Larger turbines with multiple stages and/or
split-shaft arrangements are stared in gradual manner to allow for controlled expansion
and thermal stressing. Many of these turbines are provided with electrically power
turning gears that slowly rotate the shaft during initial stage of start-up.