Вы находитесь на странице: 1из 2

RCC COLUMN SIZE CALCULATION

Axial Compressive Load on Column 1000 KN Enter Dia of Steel 16

Factored Load on Column 1500 KN 1206


1500000
Grade of Concrete (Fck) 30 Enter Number of Bars 6

Grade of Steel (fy) 500 Dia of Internal Ties 8

% of Steel in Concrete 1 1) 1 / 4 of Dia of Larger Bar 1.5


Area of Steel in Concrete 0.01 2) 8 mm 8
Area of Concrete 0.99
11.88 3.35
Gross Area of Column 98490 Pitch of Lateral Ties 260

Size of Column 314 314 1) Least Lateral Dimension 320


mm mm 2) 16 x Dia of Smaller Bar 256
Size of Column(Provide) 320 320 3) 300 mm 300
mm mm
Area of Column 102400 mm2
Main Steel 16 Nos.
Area of Steel 1024 mm2 Lateral Ties 8 Pitch @
mm2

Pitch @ 260 mm
mm
mm
mm

Main Steel 16
mm Nos. 6
mm Lateral Ties 8
mm

6
260