INTRODUCTION

It measures the forces necessary for


Viscosity is a property that measures the resistance of gradual deformation to occur as a
molecules within a liquid result of shear stresses dependent
on the nature of the fluid.

Viscosity is measured through a


body that is forced to rotate within
a fluid by the external or controlled
force of a rotor, this instrument is
called a rotary viscometer
VISCOSÍMETRO BROOKFIELD

It is a viscosity measurement and control It measures viscosity by capturing the torque


instrument, which is governed by the principle required to rotate a needle immersed in the study
of rotational viscosimetry. fluid at a constant speed.

The torque is proportional to the viscosity


resistance (speed) over the number of the
immersed needle
VISCOMETER BROOKFIELD
The deformation of the spring is observed
The needle rotates by the action of a in an analogical indicator, being the
synchronous motor through a calibrated deformation proportional to the viscosity of
spring.. the fluid.

Being able to measure more than a number of


ranges since, for a given deflection, the viscosity
is directly proportional to the spindle speed and
is related to the size and shape of the spindle
INSTALLATION
CALIBRATION

The calibration of Brookfield


viscometers includes the
determination of the F

It shows the relationship of the sources


of uncertainty with the measurand and
indicates the possible correlations that
can exist between different sources of
uncertainty
EQUIPMENT OVERVIEW

The power consumption


corresponds to 8 W although The operating temperature is from 0°c to 40°
it supports a power supply of C and a relative humidity from 10% to 90%
up to 15 W.

It weighs approximately 9 kg

ts accuracy is +- 1% of a full Has a repeatability of +- 0.2% on a full scale in


scale in use. use
LABORATORY STAND ASSEMBLY
UP: Off
Turn off the engine and stop the rotary dial.
The rubber switch stick on the
viscometer controls the engine and
has three positions On: Medium
Makes the dial to turn at the selected speed

Abajo: Pause
It makes the dial to pause when you turn
EQUIPMENT DESCRIPTION

The equipment consists of a digital Brookfield


rotational viscometer (1) with support (2), spindle
(3), thermocouple (4) and base screws (5).
EQUIPMENT PREPARATION
Place the viscometer in its Connect the thermocouple cable to the
holder, connect to the electric viscometer and secure the thermocouple
current without switching on. to the beaker with the aid of the clip.

Place the chosen spindle by


noting the number indicated at Level the bubble on top of the viscometer
the top of the spindle. by first gently moving the viscometer
head and then turning the screws on the
base
EQUIPMENT OPERATION
If you wish to see on the
Turn the viscometer on by display the value obtained
pressing the ON/OFF button from the viscosity (cP),
on the back. Waiting for the instead of the % of torque,
autozero. press Select display.

If another spindle number appears on Use the arrows if you


the display when placed, press Select want a previous spindle
spindle (SP) and use the UP or DOWN speed. This speed will
arrows to indicate the spindle number, appear to the right of
press SP again. RPM and the current
speed will appear to the
left of RPM.
EQUIPMENT OPERATION

To change the spindle speed press the


Set speed key. The previous speed will
be taken over by the current one, so
you must set another previous speed if
you want to cover the speed range of
the viscometer.

Stop the engine by pressing the engine


ON/OFF button.
SELECTION OF RANGE, COEFFICIENT, SPINDLE AND
SPEED
Table of spindle utilization ranges and speeds

Table of spindle utilization ranges and speeds


NOTE: When viscosity is difficult to predict,
assume a high viscosity and test with the
spindles from highest to lowest and speed
from lowest to highest.
MEASURE OF A LIQUID WITH A DESCONOCIDA
VISCOSITY
If, when taking the reading, the
For samples with high viscosity, select percentage of measurement is
spindle 3 with low rotation speed. between 20% and 90%, the average
viscosity is correct.

If the percentage is not


Remembering that it is necessary to
within this range, the
change the speed and the spindle.
viscometer will give a
warning.
MEASUREMENT CONSIDERATIONS

Viscosity measurement should be accepted within the range % . torque equivalent 20% to 90% for any
combination of spindle rotation - speed

Measurements should be considered in laminar flows

Place the appropriate amount of fluid for the test, this will depend directly on the spindle to be
worked

The container size for viscosities < 30 000 cP should be a 600 ml beaker with a working
volume of 500 ml and for fluids > 30 000 cP use containers that allow a working fluid height
of 8 to 12 cm

The spindle must not be altered by frictional forces with the walls of the vessel or with
the bottom of it and the head must be immersed in the fluid to be worked
NEEDLE (SPINDLE) #3
Generally used for the measurement of
viscosities in fluids that have characteristics
almost related to gelling
POSSIBLE FOODS TO STUDY
➔ Sauces
➔ Honey
➔ Oils
➔ Jams
➔ Chocolates
➔ Creams
➔ Butter
➔ Dips
Conclusions

The viscometer is a system that allows the


determination of viscosity by means of rotational
forces that can be adjusted according to the
nature of the fluid

The determination of the viscosity depends on


properties such as the temperature of the fluid,
the configuration of the equipment, the choice
of speed and the spindle.
Spindle 3 is used for measuring
fluid gelled foods, sauces, honeys,
dips, etc.
REFERENCIAS
● InfoAgro. Manual de instrucciones viscosimetros digitales series 802/807.
Recuperado de:
https://www.infoagro.com/instrumentos_medida/instrucciones/instrucciones_viscosimetro_rotacional_digital_nahita_807.pdf
● InfoAgro. (2011). Viscosímetro rotacional. Manual de instrucciones 50801000.
Recuperado de:
https://www.infoagro.com/instrumentos_medida/instrucciones/instrucciones_viscosimetro_rotacional_analogico_nahita_801.pdf
● Manual viscosimetro Brookfield LVT español (2008) recuperado de:
https://www.academia.edu/35003901/Manual_viscosimetro_brookfield_LVT_espanol
● Trujillo S., Schmid W., Lazos R., Galván M. del C. (2000), Incertidumbre en la
calibración de viscosímetros brookfield, Centro Nacional de Metrología, Laboratorio
de Viscosidad