Вы находитесь на странице: 1из 1

Meadows – 1 Villa

Existing Scenario
Indoor Ac Unit CFM Tonnage Location Room Name Cfm
GAC-01 Family Room 964
1294 3.23
Kitchen 330
Servant Room 300
Ground Floor
GAC - 02 700 1.75 Utility 200
Corridor 200
Living Room 900(450*2)
GAC -03 2137 5.34
Dining 1240(620*2)
Master bedroom 1044(522*2)
FAC-04 1294 3.23
Dressing Room 250
Bedromm03 954(477*2)
FAC -05 1294 3.23
First Floor Lobby 400
FAC -06 670 1.67 Bedroom01 670
Bedroom02 670
FAC -07 670 1.67 Washroom 50
corridor

Tonnage = CFM/400 - Thumb Rule


------------------------------------------------------------------------------------------------------------------------------------------------ --------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- ------------------------------------
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Spectro+ Solar Duct Units


Indoor Ac CFM Tonnage Solar AC Solar Ac Location Room Name Cfm (indoor throw)
Unit Tonnage Max. Rated
kW
GAC-01 - Family Room 964
Solar 1294 3.23 3.5 3.3 Kitchen 330
Ground
Servant Room 300
Floor
GAC – 02 - 700 1.75 Utility 200
Solar 3.5+3.5 3.3+3.3 Corridor 200
Living Room 900(450*2)
2137 5.34
Dining 1240(620*2)
Master 1044(522*2)
FAC-03- bedroom
1294 3.23 3.5 3.3
Solar Dressing 250
Room
FAC -04- First Floor Bedromm03 954(477*2)
1294 3.23 3.5 3.3
Solar Lobby 400
670 1.67 Bedroom01 670
FAC -05-
Bedroom02 670
Solar 3.5 3.3
670 1.67 Washroom 50
corridor