Features
PL-P
PL-P
CEILING
CEILING
Series
PC-P
PC-P
OUTDOOR
CASSETTE
SERIES
SERIES
SUSPENDED
Auto-swing
Features Summary
PL-P18BAK
PC-P18KAK
PU-P18VAKD
Computerized Dehumidifier
Auto-fan Speed
PC-P24KAK
High Ceiling Mode
PU-P24VAKD
(Up To 3.5m P18/24, 4.5m P30/36/42)
I-see Sensor (Optional)
Compact Design
3.0HP
PL-P30BAK
Flockless Vanes
Self-diagnosis Function
PL-P36BAK
PC-P36KAK
PU-P36YAKD
CPAC - Ceiling-Concealed
Error Code & Filter Indicator
(For Wired Remote Controller)
PC-P42KAK
PL-P42BAK
PU-P42YAKD
Auto Restart
VRF System
Wireless Type (Optional For PC-P)
Remote
Controller
(Optional)
(Optional)
CEILING CASSETTE
PL-P SERIES
PL-P18/24/30/36/42BAK
(Optional)
a fan speed reduced by 20% compared to concentional models also aesthetic installation even in narrow PL-P30/36/42BAK
(Optional)
PC-GAKD PC-P**KAK
With optional i-see Sensor
corner panel sensor
The i-see Sensor temperature-sensing technology Optional drain pump for full-capacity
improves energy efficiency & enhances room comfort models
The “i-see Sensor” is an innovative Mitsubishi Electric
The pumping height of the
technology that uses a radiation-based sensor to monitor
optional drain pump has been
temperature throughout an entire room. When connected
increased from 400mm to
to the air conditioner control panel, the i-see Sensor works
600mm, expanding flexibility
to maximize room comfort.
in choosing unit location
i-see Sensor Operation during installation work.
The “i-see Sensor” rotates 90° at
intervals of 5sec, accurately measuring Equipped with automatic air-speed
the temperature throughout the room
(covering entire floor space).
adjustment
In addition to the conventional 4-speed setting, units are now
90° 90° 90°
equipped with an automatic air-speed adjustment mode. This
rotation rotation rotation setting automatically adjusts the air-speed to conditions that
5sec 5sec 5sec 5sec match the room environment. At the start of cooling
measurement measurement measurement measurement
operation, the airflow is set to high-speed to quickly cool the
“Sensible temperature control” prevents excessive cooling room. When the room temperature reaches the desired
through pioneering control technology setting, the airflow speed is decreased automatically for stable
By measuring the inlet temperature and floor temperature, comfortable cooling operation.
temperatures felt by the human body (sensible
temperature) will be computed. This allows the proper
Strong Gentle
sensible temperature to always be maintained through the
suppression of excessive cooling.
After room
(For simultaneous twin operation, please install the i-see Sensor corner panel on both indoor units.) Start of cooling… temperature is stabilised…
without the i-see Sensor and automatic air- speed adjustment mode 0
32˚C
Fixed condition Fixed condition
23˚C
intake –50
–100
–150
Units are equipped with –200 PC-P30/36/42KAK
Felt temperature: 26.5˚C Felt temperature: 28˚C 14˚C –250 PC-P18/24KAK
a knock-out hole that –300
Floor temperature
Fixed condition
Floor temperature
Fixed condition
enables the induction of 0 1 2 3 4
Airflow volume (m 3/min)
Felt temperature Felt temperature
fresh outside-air.
28˚C 28˚C
26.5˚C 26.5˚C
Flockless vanes
Inlet temperatureFelt temperature drops Inlet temperature
No drops in felt temperature
30 minutes 30 minutes
The felt temperature drops according to the drop in Air temperature is adjusted according to the floor
floor-level temperature. If the floor-level temperature temperature to keep the felt temperature at 28°C.
is not monitored during long cooling operation, the With the adoption of flockless vanes, dirt and other impurities
felt temperature becomes chilly.
can be cleaned off easily with mild household detergent.