Вы находитесь на странице: 1из 8

PROJECT INFORMATION OF DIRECT FIRED ABSORPTION CHILLE

PROJECT
LOCATION (CITY / COUNTRY)
General
LOCAL AGENT
(Must)
QUANTITY
Bidding DATE / DELIVERY DATE
TYPE
COOLING CAPACITY
Capacity
HEATING CAPACITY
POWER
FLUID
INLET TEMP.
OUTLET TEMP.
Chilled
FAULING FACTOR
Water
PRESSURE DROP
WORKING PRESSURE
FLANGE TYPE
FLUID
INLET TEMP.
OUTLET TEMP.
Heating
FAULING FACTOR
Water
PRESSURE DROP
WORKING PRESSURE
FLANGE TYPE
FLUID
INLET TEMP.
OUTLET TEMP.
Cooling
FAULING FACTOR
Water
PRESSURE DROP
WORKING PRESSURE
FLANGE TYPE
FUEL
LOWER CALORIFIC VALUE (GAS)
Fuel
LOWER CALORIFIC VALUE (OIL)
GAS PRESSURE
Please for Gas Pressure considerate minimum

Special
Option
Special
Option
ON OF DIRECT FIRED ABSORPTION CHILLER/HEATER
MALL CAMINO REAL
LIMA - PERU

1 Unit(s)

WCDH (100~1500RT, COP 1.51, Water press. : 10k, Co.W : 32/37)

400 RT

- kcal/h

380 / 60 / 3 V / Hz / Ph

Water E.G or P.G concentration (%)

12 ℃

6.2 ℃

2E-05 m2∙℃∙h/kcal

By Model m H2O

By Model kg/Cm2∙G

ANSI
Water E.G or P.G concentration (%)

Realted with cooling water flow rates ℃

60 ℃

2E-05 m2∙℃∙h/kcal

By Model m H2O

By Model kg/Cm2∙G

ANSI
Water E.G or P.G concentration (%)

95 ℉

85 ℉

5E-05 m2∙℃∙h/kcal

By Model m H2O

By Model kg/Cm2∙G

ANSI
Gas(LNG)
0.04 kJ/Nm3 GJ/sm3
kcal/kg

mmHg

Please for Gas Pressure considerate minimum


Blank(gray colored) items be a LGE standard.
PROJECT INFORMATION OF DIRECT FIRED ABSORPTION CHILLE
PROJECT
LOCATION (CITY / COUNTRY)
General
LOCAL AGENT
(Must)
QUANTITY
Bidding DATE / DELIVERY DATE
TYPE
COOLING CAPACITY
Capacity
HEATING CAPACITY
POWER
FLUID
INLET TEMP.
OUTLET TEMP.
Chilled
FAULING FACTOR
Water
PRESSURE DROP
WORKING PRESSURE
FLANGE TYPE
FLUID
INLET TEMP.
OUTLET TEMP.
Heating
FAULING FACTOR
Water
PRESSURE DROP
WORKING PRESSURE
FLANGE TYPE
FLUID
INLET TEMP.
OUTLET TEMP.
Cooling
FAULING FACTOR
Water
PRESSURE DROP
WORKING PRESSURE
FLANGE TYPE
FUEL
LOWER CALORIFIC VALUE (GAS)
Fuel
LOWER CALORIFIC VALUE (OIL)
GAS PRESSURE
Please for Gas Pressure considerate minimum

Special
Option
Special
Option
ON OF DIRECT FIRED ABSORPTION CHILLER/HEATER
MALL CAMINO REAL
LIMA - PERU

2 Unit(s)

WCDH (100~1500RT, COP 1.51, Water press. : 10k, Co.W : 32/37)

900 RT

- kcal/h

380 / 60 / 3 V / Hz / Ph

Water E.G or P.G concentration (%)

12 ℃

6.2 ℃

2E-05 m2∙℃∙h/kcal

By Model m H2O

By Model kg/Cm2∙G

ANSI
Water E.G or P.G concentration (%)

Realted with cooling water flow rates ℃

60 ℃

2E-05 m2∙℃∙h/kcal

By Model m H2O

By Model kg/Cm2∙G

ANSI
Water E.G or P.G concentration (%)

95 ℉

85 ℉

5E-05 m2∙℃∙h/kcal

By Model m H2O

By Model kg/Cm2∙G

ANSI
Gas(LNG)
0.04 kJ/Nm3 GJ/sm3
kcal/kg

mmHg

Please for Gas Pressure considerate minimum


Blank(gray colored) items be a LGE standard.