In Q.2, you have written only mathematical equations. Add some theory part like...

Area for the


compression cycle is given by...

Volumetric efficiency you have calculated in Q. 5 is wrong

Gap between the rotor and casing of root blower should not be there.

Volumetric efficiency you have calculated is wrong. Actually volumetric efficiency is coming as negative
due to very large pressure ratio.

Value of mass flow rate in Q.5 and pressure P2 in Q. 4 is wrong