City of Columbus CITY OF COLUMBUS PERMIT NO: NEWC1802381

Mayor Andrew J. Ginther DEPARTMENT OF BUILDING AND ZONING SERVICES


Issue Date: 12/18/2018
111 N. Front Street, Columbus, OH 43215

BUILDING PERMIT
Commercial : Structural : New Structure

CONTRACTOR INFORMATION
LICENSE: G02084
PHONE: (614) 356-5502
FAX: (614) 356-5660

MAILING ADDRESS OWNER OF RECORD


BPI ASSOCIATES LLC THE ALEXANDER LLC
600 STONEHENGE PARKWAY MATT CANTERBURY
DUBLIN, OH 43017 985 N HIGH ST STE 200
COLUMBUS OH 43215, OH

ADDRESS AND PROJECT INFORMATION SUBCONTRACTORS

PERMIT NUMBER: NEWC1802381


PARCEL NUMBER: 010034340
PROJECT ADDRESS: 265 E STATE ST

OBC

COST OF CONST.: $50,000,000


USE GROUP:
CONST. TYPE:
SQ. FT.: 271580

WORK DESCRIPTION
Plan Approval:
Conditional
Reviewed for compliance under: 2017 OBC and ICC A117.1-2009 with modifications in OBC 1112.0.
Work not included in this approval: Pool, Fire Alarm, & Fire Suppression
Separate permits required for these items.
Use/Occupancy Group: The building is separated by a 3 Hr. barrier (Podium Building).
Occupancies below the podium are S-2 (parking garage), B, A-2, or M.
Occupancies above the podium are R-2 dwelling units with A-3 spaces.
Construction Type: I-A, Below 3 hour podium
III-A, Above 3 hour podium
Description of work: New Construction of 6 story w/basement podium building. Gross area for all stories is 279,913 S.F. Floor area varies per story. Building includes 2 levels of for parking, pool,
courtyard, diesel backup generator, amenity areas (assembly), and fitness center. A walk out terrace provided on the second floor is accessible only to maintenance personnel and to the enclosed boundaries
provided to the adjacent dwelling units. The vacant spaces below the podium will require a separate permit for occupancy. Tenant usage may require additional MEP requirements not validated under this
permit.
Conditions of the occupancy: 1.In accordance with section 1001.4 Fire Safety and Evacuation Plans must be provided for all occupancies and buildings, such fire safety and evacuation plans shall comply
with the applicable provisions of sections 401.2 and 404 of the fire code and be approved by the division of fire.
2.Separate occupancy permits required for vacant spaces on first floor.
Occupant Load: Below podium gross occupants: 693
Above podium gross occupants: 1,890
Maximum cap card:18-5581-A, Room Numbers 228,229A,229B, and 230: 218 Occupants
18-5581-B, Amenity Deck, Room 253: 180 Occupants
18-5581-C, Enclosed Pool Area: 184 Occupants
Fire Suppression System:

***IT SHALL BE UNLAWFUL TO REMOVE THIS PERMIT FROM THE JOB SITE***
Additional permits may be required. Permit holder is responsible to obtain all required permits and inspections including the final inspection . Failure to obtain
final inspections for all work may result in the expiration of this permit as outlined below.

EXPIRATION
In accordance with Section 105 of the Ohio Building Code/Residential Code of Ohio and Section 4113.03 of the Columbus Building Code, a permit/plan
approval is invalid if construction, erection, alteration or other work upon the bulding has not commenced within 12 months of the approval of the
permit/plan approval OR if during the course of construction, work is delayed or suspended for a period of more than 6 months. Any request for an extension
must be submitted at least 10 days in advance of the expiration of the permit/plan approval.
City of Columbus CITY OF COLUMBUS PERMIT NO: NEWC1802381
Mayor Andrew J. Ginther DEPARTMENT OF BUILDING AND ZONING SERVICES Issue Date: 12/18/2018
111 N. Front Street, Columbus, OH 43215 Site: 265 E STATE ST

INSPECTION RECORD

INSPECTION REQUESTS
OWNER OF RECORD
Phone: (614) 645-8235 The Alexander Llc
Life Safety Fax: (614) 645-2434 -or- Matt Canterbury
Fax: (614) 645-2433 BZSCFDInspectionRequests@columbus.gov 985 N HIGH ST STE 200
Online: Columbus.Gov/Inspection COLUMBUS OH 43215
OH
Cancel or Reschedule: (614) 645-7847 General Questions: (614) 645-5698

Inspection Type Approval Inspection Type Rough Approval Final Approval

FOOTING HVAC

FOUNDATION FUEL-GAS PIPING

PLUMBING UNDERGROUND REFRIGERATION/HYDRONICS

INTERIOR DRAINAGE EXHAUST


(1,2,3 FAMILY)

SLAB INSULATION FIREPLACE/WOOD BURNING


STOVE (FACTORY BUILT)

FRAMING ELECTRIC

FIRE RATED ASSEMBLY PLUMBING

INSULATION FIREPLACE (MASONRY)


(WALLS, CEILINGS, ETC.)

DOMESTIC WATER SERVICE FIRE SUPRESSION


P: (614) 645-5781 (ALTERNATIVE)

SEWER SERVICE FIRE SUPPRESSION


P: (614) 645-7490

FIRE ALARM
SPECIAL CONDITIONS

CERTIFICATE OF COMPLETION / OCCUPANCY - FINAL


THE SIGNATURE FOR FINAL INSPECTION IN THE BOX
TO THE RIGHT REPRESENTS AN APPROVAL OF A
CERTIFICATE OF COMPLETION PER THE OBC/RCO. CERTIFICATE OF COMPLETION / OCCUPANCY - FINAL

PLAN DISCREPANCY SUBMITTED TO STRUCTURAL ELECTRICAL MECHANICAL PLUMBING


CHIEF BUILDING OFFICIAL?

INSPECTORS WILL NOT INSPECT ANY STRUCTURE THAT TO THEIR KNOWLEDGE IS NOT IN COMPLIANCE WITH LOCAL, STATE AND FEDERAL SAFETY AND HEALTH LAWS AND OSHA REGULATIONS.

***IT SHALL BE UNLAWFUL TO REMOVE THIS INSPECTION RECORD FROM THE JOB SITE***
Additional permits may be required. Permit holder is responsible to obtain all required permits and inspections including the final inspection . Failure to obtain
final inspections for all work may result in the expiration of this permit as outlined below.

EXPIRATION
In accordance with Section 105 of the Ohio Building Code/Residential Code of Ohio and Section 4113.03 of the Columbus Building Code, a permit/plan approval is invalid if construction,
erection, alteration or other work upon the bulding has not commenced within 12 months of the approval of the permit/plan approval OR if during the course of construction, work is
delayed or suspended for a period of more than 6 months. Any request for an extension must be submitted at least 10 days in advance of the expiration of the permit/plan approval.