Вы находитесь на странице: 1из 2

Inverter

Type Fronius ECO 25.0-3-S


Min. MPP voltage Max. MPP voltage Max. DC voltage
[V] [V] [V]
580 850 1000

Module
Type Jinko JKM 260PP
MPP voltage (STC) Open-circuit voltage (STC) Max. DC voltage
[V] [V] [V]
31.1 38.1 1000

Temperature coefficient of Open-circuit voltage (no load)


NOCT Ctuoc b
[°C] [%/°C] [V/°C]
44 -0.3 -0.1143
=(b/Uoc)*100 =(Uoc*Ctuoc)/100

Temperatures
Tair,max Tair,min
[°C] [°C]
50 0
Tcell,max Tcell,min Delta_Tcell,min
[°C] [°C] [°C]
80 0 0
=Tair,max + (NOCT - 20) / 0,8

String
Nm (number of modules in a string)
24

Min. MPP voltage @80°C Max. MPP voltage @0°C Max. Uoc voltage @0°C
[V] [V] [V]
595.52 814.98 982.98

= Nm*[Umpp+ = Nm*[Umpp+ = Nm*[Uoc+


Uoc*Ctuoc*(Tcell,max-25)/100] Uoc*Ctuoc*(Tcell,min-25)/100] Uoc*Ctuoc*(Tcell,min-25)/100]

>= Min. MPP voltage (inverter) <= Max. MPP voltage (inverter) <= Max. DC voltage (inverter)
<= Max. DC voltage (module)
Voltage drop
Bala:
1 0.9 to 1

Min. MPP voltage @°C


[V]
595.52

= Nm*[Umpp*volt drop+
Uoc*Ctuoc*(Tcell,max-25)/100]