Вы находитесь на странице: 1из 2

FASSADEN BEFAH RSYS'I

ma n ntech

MANNTECH Fassadenbefahrsysteme GmbH ' Mmesmannsrasse 5 ' D-82291Mmendorf

To whom it may concern

Yom reference/ Om referenc Telephone +49(0)8145 999- 100 Mmesmmstrasse 5


your message of Dept,/Participmt Telefax +49 (0) 8145 999 -222 82291 MamendorflGemmy
e-mail erich.dinkler@mamtech.de
18ft December 2010

Manntech statement for our Business Partners and Customers regarding the
accident in Dubai on 30th November 2010

On Tuesday evening, 30th November 2010 we received the following news from Dubai:

Two facade workers of Indian nationality, whilst working at a considerable height on the exterior
fagade of the Burj Dubai Plot 12 building for the firm Multiform, tragically fell to their deaths.
This greatly shocked us and we feel the deepest sympathy and sorrow for the workers and their
families.

Manntech immediately sent a third party inspector to Dubai GÜD. Presently, a detailed investi-
gation is ongoing. However, we would like to give all our business partners and customers the
information we do have regarding this situation in Dubai and how we are proceeding.

It will take some time to provide final clarification of the full causes of this incident. The chain of
parties involved is very long and includes the BMU manufacturer (Manntech), one of our special-
ist suppliers (hydraulic cylinders), our local partner, the customer, the company operating the
BMU and local authorities.

We have delivered a total of four static crane-type BMUs to the Burj Dubai Plots 12 and 13. Each
BMU is equipped with a telescopic mast and telescopic jib (a.k.a. boom or arm). These machines
have been in use since August 2010 for the purposes of facade installation at the customer's re-
quest. Manntech's local partner handed over the machines for temporary use during the construc-
tion phase, and with explicit operating restrictions regarding the use of the BMUs for the proposed
construction application.

Initial information received from the site is that one BMU had a failure within an already replaced
hydraulic cylinder operating the telescopic mast. We still have to establish the fulI circumstances
leading up to this component failure. However, it resulted in the telescopic mast suddenly retract-
ing vertically into itself, causing the jib to drop by approximately 3 meters.

Mmging Didor Edch Dinkls Telephme +49(0)8145-994 Banksincem&y: ßN BIC


Telefd: +49(0)8145-99-2s Sparfta*Fffiqfeldbnk AeoutNo-1428515 So(Cod€7m53070 DE4070053070m01428515 BYLADEMIFFB
H€dqM6: Mmendorf e-roil: ex?o(@,lwt6hd€ Hwovercinsbak, Olching Atroünt No. 87400557 So( Code 70O 202 70 DEr5 7002 0270 0087 4005 s7 TTYWDEW
Cmty Coü Muich: HRB 127884 IffiI: lütp://wv.lffi€h.de
USt-IdNr D8185996338

Certified according to DIN ISO 9001


FASSADEN BEFAH RSYST

ma n ntech

The telescopic jib was fully telescoped out and at its maximum reach dimension of 20 meters.
The telescopic jib absorbed the impact forces and remained in place. However the slewing head
connection at the end of the jib appears to have failed as the vertical movement of the combined
inner telescoping mast, telescoping jib, counterweight, slewing head and gondola came to an in-
stant stop by hitting the outer telescoping mast and main frame of the BMU.

As a precautionary measure, all BMU's with double action cylinders from the same specialist sup-
plier will be taken out of service until the final results of the investigation and thorough examina-
tion are received. This will be carried out by an independent institute as soon as we receive full
clearance to proceed from the local authorities.

There are just two further installations worldwide where components from the same specialist
supplier have been used in the BMU design and production. No BMUs supplied to your market
include components from this specialist supplier.

The BMUs MANNTECH, (formerly Mannesmann) products are very robust and are designed and
constructed according to all valid Industry Standards (Machinery Directive, harmonized European
Standard Norms e.g. EN 1808, local standards if requested) and are certified by the German Tech-
nical Supervision Authority according to DIN/EN/ISO 9001. An immediate review of all our doc-
uments (type testing documents, structural analysis, calculations, purchasing documents, work
shop test report) showed no breaches of the relevant standards and codes. Each Manntech Machine
is fully engineered and assembled in our factory, then tested in accordance with Manntech ISO
testing procedure. After testing it is disassembled for delivery to site.

We are still very proud of our company's continuous safety record of almost 60 years of age. Prior
to this accident we have supplied almost 8,000 fagade access systems all over the world, and have
no record of such an incident with one of our BMUs. We credit this safety record to our interna-
tionally recognized approach to high quality product design and manufacturing standards.

Please be assured that whatever circumstances may be established following the investigation of
this incident, we remain highly motivated and committed to our product quality and safety aware-
ness. We will continue to further improve and optimize our standards in design, safety and quality
as we have been doing for many years.

We look forward to receiving your continued trust and ongoing successful cooperation and sup-

c"u
Managing Director

Fassadenbefahrsysteme GmbH

Вам также может понравиться