TOP LIMIT STOP SWITCH


UP ARROW

FIRE CONTACT

DOOR LOCK CONTACT

DOOR CONTACT
DOWN ARROW REGISTER LAMP
24V/1W DIGITAL MACHINE ROOM
FLOOR 2

D DISPLAY D
OUT OF
SERVICE OVERSPEED
GOVERNOR

FIRE
CALL BUTTON

BUSY
+ MOTOR BRAKE Coil

FAN
M
UP ARROW 220V AC
REGISTER LAMP

DOOR LOCK CONTACT

DOOR CONTACT
24V/1W

DIGITAL THERMISTOR
FLOOR 1

DOWN ARROW DISPLAY

t
C CALL BUTTON C

OUT OF
SERVICE

EMERGENCY
REGISTER LAMP
24V/1W

STOP
BUSY +

CALL BUTTON

Overspeed governor rope


UP ARROW

tensioning weight
BOTTOM LIMIT
STOP SWITCH
24V
BOTTOM FLOOR

DIGITAL

DOOR LOCK CONTACT


REGISTER LAMP

DOOR CONTACT
DOWN ARROW 24V/1W
DISPLAY
24V
A
2B B
B F B
OUT OF

HYDRAULIC
2G G

BUFFER
SERVICE

STOP
24V
2C E C
CALL BUTTON D

PIT STOP
BUSY +
24V

AUTOMATIC DOOR
CONTACT
*DK100

190 (Simple Push Button)


100

1000
100

301 201 301 401


202 202 302 402
302
203 203 303 403

FULL
32
31
39
12

2BC(1)
2G(-)

1000
100

G
FIRE

.......

FAN
COLLECTIVE

T1
T2
Mp

840
2000
Earth

DOWN
COLLECTIVE
140
135

120
UP COLLECTIVE
130

113

110
112

111
A A

114
115
*DK100 : In duplex lift systems, landing button SIMPLE COLLECTIVE
register lamps common end is F/7.5.5.02.69
SIMPLE PUSH BUTTON
connected to DK100 terminal. This document is a sample for applications. All information contained in FLOOR CONNECTIONS
See ACT group connection diagram. these materials are subject to change by Aybey Elektronik without notice.

LIFT CONTROLLER Aybey Elektronik assumes no responsibility for any damage, liability, or
other loss rising from these inaccuracies or errors.
AYBEY
ELEKTRONİK
SERIES
PROJ.
REV.
ACT DRW. M. AKKUŞ
ACT002 APPRV. M. AYBEY
02 DATE 19 JAN 13
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

BATTERY

RELEVELLING ZONE SWITCH-2

RELEVELLING ZONE SWITCH-1


CHARGE CAR TOP
INSPECTION
AUTOMATIC
BOARD SWITCH

MINIMUM LOAD CONTACT


MAGNETIC STOP START DOOR

RETIRING CAM
(-)GND
SHALTERS 2 1 4 3 2 1 BOARD

OVERLOAD CONTACT

FULL LOAD CONTACT

+12V
SWITCH DOWN (KSR1)
HIGH SPEED LIMIT
SWITCH UP (KSR2)
HIGH SPEED LIMIT
UP
4 3 SUPPLY
CAR TOP

4 3
D 2 1 L-Phase D
COUNTER

DWN 220V AC

STOPPER
STOPPER

STOPPER
N-Neutral

DOWN
4 3
UP
PE

CLOSE
OPEN
EARTH

COM
Roof Exit Door
MKD

STOP Contact
MKU
MK
M0

SOCKET
ML2

ML1

Parachute
Contact
220V AC
KSR1

KSR2

REGISTER LAMP INTERCOM


Waitman Switch
BOARD

STOP
24V/1W
DIGITAL CABIN
C DISPLAY LAMP C
BUTTON 12V
A
+ - C D
2B B
Overload F 220V AC
CABIN

2G G
REGISTER LAMP Lamp 500W
24V/1W + 2C E C
D
DOOR OPEN BUTTON

DOOR CLOSE BUTTON

Automatic Door Contact


BUTTON 24V/2W

BUT
REGISTER LAMP BUT
BUZZER
24V/1W
INTERCOM
BUTTON
BUTTON
LED+
LED-
FLEX CABLE

B B

INT-A
INT-B
INT-C
INT-D
MKD***
MKU***

ML2**

WTM
MO

MK

ML1**

804
805
802
817*

818*

K20

DTS

120
117
116
115
Earth

1 (FAZ)

DCM
2

MP/N

OPN

CLS

2001
810
1 (2BC)
- (2G)

.........
401
402
403
501
500

35

G
869
1000
100

INTERCOM
PHONE
*817-818 : When mechanical switches are used as high speed switches in well, ignore

130 135
120 130
A these connections in cabin connections. Automatic Landing Door A

Semi-automatic Landing Door F/7.5.5.02.69


**ML1-ML2 : Use when Floor Selector is [A05] =0; pre-opening door or releveling
activated or UCM Controller [A17] is set to 4 or 6. Standard in hydraulic system.
LIFT CONTROLLER
This document is a sample for applications. All information contained in CAR CONNECTIONS
these materials are subject to change by Aybey Elektronik without notice. DRW. M. AKKUŞ
***MKU-MKD : Use when counter type (A05: 0 or 6) Aybey Elektronik assumes no responsibility for any damage, liability, or AYBEY SERIES ACT
PROJ. ACT001 APPRV. M. AYBEY
other loss rising from these inaccuracies or errors. ELEKTRONİK
REV. 02 DATE 24 JUN 14

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

SCC SCC BOARD SCC SCC CABIN BOARD


CAR TOP SCC-4 & ACC
BATTERY STOP AUTOMATIC

RELEVELLING ZONE SWITCH-2


CABIN BOARD

RELEVELLING ZONE SWITCH-1


BOARD REGISTER BOARD SERIAL INPUTS CHARGE 2 INSPECTION DOOR
1
OUTPUT CALLS COMMUNUCATION

DCM
SWITCH

OPN
BOARD BOARD

CLS
START

RETIRING CAM
O1/35

CO/401
SUPPLY

C2/403
C1/402

KA

KO

KK
MAGNETIC

I1/MO

I5/804

(-)GND

1
1

I2/869
I4/500
I3/501

2
WTM
2

SWITCH DOWN (KSR1)

DTS
K20

+12V
SHALTERS 4 3

HIGH SPEED LIMIT


SWITCH UP (KSR2)
HIGH SPEED LIMIT

GND
UP CLOSE

CL
CH
V+
CAR TOP

4 3
D 4 3
COM D
2 1
DWN OPEN
STOPPER
STOPPER

STOPPER

DOWN COUNTER
UP

4 3 SUPPLY
M0 220V AC

Neutral-N
Phase-L

PE
Roof Exit Door

Overload
Contact
MKD

STOP Contact
MKU

ML2

ML1
MK

KSR1

KSR2

Parachute
Contact
SOCKET
220V AC EARTH

REGISTER LAMP INTERCOM


24V/1W Overload
Lamp BOARD

STOP
C BUTTON + 12V C

+ - C D CABIN

SCC & ACC BOARD


TO DISP INPUT OF
24V/2W
LAMP

WAITMAN SWITCH
DOOR OPEN BUTTON

DOOR CLOSE BUTTON


CABIN

REGISTER LAMP
24V/1W
220V AC
500W

Automatic Door Contact


BUZZER
BUTTON

10 CC7D
REGISTER LAMP BUT
24V/1W BUT
INTERCOM
BUTTON
BUTTON LED+
LED-
DISPLAY
FLEX CABLE

B B

INT-A
INT-B
INT-C
INT-D
MKD***
MKU***

ML2**

CL0
CH0
ML1**

1000
100
MK

817*

818*
Earth

1 (PHASE)

2001
810
MP/N
116
120
117

115
INTERCOM
PHONE
*817-818 : When mechanical switches are used as high speed switches in well, ignore

130 135
120 130
A these connections in cabin connections. Automatic Landing Door A

Semi-automatic Landing Door


**ML1-ML2 : Use when Floor Selector is [A05] =0; pre-opening door or releveling
activated or UCM Controller [A17] is set to 4 or 6. Standard in hydraulic system.
LIFT CONTROLLER F/7.5.5.02.69

This document is a sample for applications. All information contained in SERIAL CAR CONNECTIONS
***MKU-MKD : Use when counter type (A05: 0 or 6) these materials are subject to change by Aybey Elektronik without notice. DRW. M. AKKUŞ
Aybey Elektronik assumes no responsibility for any damage, liability, or AYBEY SERIES ACT
PROJ. ACT029 APPRV. M. AYBEY
other loss rising from these inaccuracies or errors. ELEKTRONİK
REV. 05 DATE 24 JUN 14
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

TRAVEL
LAMP SAFETY
SOCKET INSPECTION BUTTON
(SOCKET) ALARM 220V AC SWITCH PARACHUTE
220V AC UP DOWN START STOP CONTACT
1 2
3 4 3 4 3 4 4 3 1 2
D D
3 4

1 2

24V DC
+100
-1000
1 869/INSPECTION
2 500/DOWN BUTTON
3 501/UP BUTTON
4 1 (Phase) 220V
5 Mp (Neutral) AC

115
C C
116 SAFETY
117 LINE
120

BATTERY
12V 1.2AH
- SPEAKER
+

B B

GONG

EXPLANATIONS SES (HELP)

HP+
Mp

AC
AC

DD
HP-
A+
1

A-
CAR ALARM
1. After assembling the system, connect the free pole of the battery to the system - + BUTTON
2. The system is designed to give 12VDC output at any case,whether there is VOLUME

line voltage or not EIK-2 AB EMERGENCY


AB
3.Even if there is no line voltage,alarm and ding-dong perform their functions. BOARD AL
LAMP

4. After line voltage is cut off, emergency light is on during next 12 minutes. AL
-
12V/MAX. 5W
After turning off, if one pushes the help button, it becomes on again. 12V
+ 12V DC
A
5. The battery of the system can feed the emergency lamp during 3 hours. A

F/7.5.5.02.69
This document is a sample for applications. All information contained in INSPECTION BOX
these materials are subject to change by Aybey Elektronik without notice.
SERIES ACT DRW. M. AKKUŞ
Aybey Elektronik assumes no responsibility for any damage, liability, or AYBEY
other loss rising from these inaccuracies or errors. PROJ. ACT051 APPRV. M. AYBEY
ELEKTRONİK
REV. 04 DATE 15 MAY 13

1 2 3 4 5 6 7 8
1 2 3 4

CFU & CDH BOARDS BUTTON CONNECTIONS

STOP SWITCH
V+
GND
CL
CH

1000
100
FLOOR 4

TOP LIMIT
DOOR CONTACT

V+
GND
CL
CH
DOOR LOCK
CFU

V+
GND
CL
CH
H H
KSR2
BUZZER

ON

1 2 345
CFU CDH
DB-
DL-
UB-
UL-
B+
L+

CAR
ON DSW* ON DSW*

BUZZER
AT TOP BUZZER
1 2 34 5 1 2 34 5
B-

DB-
DL-
UB-
UL-
B+

UB-
DL-
DB-
B+
L+

UL-
32
31

L+
B+
12
31
32
39
L-
L+

B-
G B+ G
FOR THIS LINE USE AT LEAST 2 x 0.75 CABLES

UP
L- CALL BUTTON
L+
V+
GND
CL
CH

B-
B+ DOWN
CFU L- CALL BUTTON
BUZZER

DOOR CONTACT
L+

DOOR LOCK
ON
FLOOR 3

1 23 45 DSW* : Set floor numbers using binary code.


DB-
DL-
UB-
UL-

1:LSB 5:MSB
B+
L+

B-
B+
L-
MACHINE ROOM
F L+ F
B-
B+
L-
L+
OVERSPEED
GOVERNOR
MAKE THIS CONNECTION FOR 16 OR MORE STOPS ONLY
POWER SUPPLY SUPPORT LINE

MOTOR BRAKE
FLOOR 2

V+
GND
CL
CH

FAN
CFU
DOOR CONTACT
DOOR LOCK

M
BUZZER

ON
E 1 2 3 45 220V AC E
DB-
DL-
UB-
UL-
B+
L+

THERMISTOR
B-

t
B+
L-
L+
B-
B+

EMERGENCY
L-
L+

STOP
D D
V+
GND
CL
CH

DOOR CONTACT
DOOR LOCK

CFU
Overspeed governor rope
FLOOR 1

BUZZER

ON
tensioning weight

1 23 45
DB-
DL-
UB-
UL-
B+
L+

B-
B+
L-
C L+ C
BOTTOM LIMIT

B-
STOP SWITCH

B+
L-
L+
DOOR CONTACT
DOOR LOCK
Red
Black
Green
Yellow

PIT STOP
BOTTOM FLOOR

HYDRAULIC

CAR AT
BUFFER
STOP
V+
GND
CL
CH

BOTTOM
CFU
BUZZER

ON KSR1
B B
1 2 3 45
DB-
DL-
UB-
UL-

FIRE CONTACT
B+
L+

CABIN DOOR
CONTACT

FIRE

B-
B+
FAN
T1
T2
Mp

840
2000
113

L-
110
112

111
115

114

L+
135

120
140

130
Yellow
Green
Black
Red

817/KSR1
818/KSR2
FIRE

1000

F/7.5.5.02.69
Earth

A A
This document is a sample for applications. All information contained in SERIAL FLOOR CONNECTIONS
100
1000
CL0
CH0

these materials are subject to change by Aybey Elektronik without notice. DRW. M. AKKUŞ
SERIES ACT
Aybey Elektronik assumes no responsibility for any damage, liability, or AYBEY
PROJ. ACT031 APPRV. M. AYBEY
other loss rising from these inaccuracies or errors. ELEKTRONİK
CONTROL PANEL 01 REV. DATE 27 DEC 12
1 2 3 4
1 2 3 4 5 6 7 8

TRAVEL
LAMP ALARM SOCKET
SAFETY
BUTTON
(SOCKET) 220V AC INSPECTION
220V AC UP DOWN START STOP
SWITCH PARACHUTE
3 4
3 4 3 4 4 3 1 2
CONTACT
1 2

D 3 4 D

1 2

4 1 (Phase) 220V
5 Mp (Neutral) AC
115
116 SAFETY
117 LINE
120

24V DC
+100
CALL -1000
BUTTON

BUTTON
BUT CH0 SERIAL
LAMP
BUT
CL0 COMMUNICATION
L+ LINE
C L- C
Earth
2 (Cabin Lamp)
BUZZER

CH
CL
GND
V+
CALLS 0-7 OPN
401 C0 DCM AUTOMATIC CAR
402 C1
CLS DOOR SIGNALS
CABIN 403
404
C2
C3
CALLS 0-7 SCC-4
CALLS
405 C4 EXTERNAL DISPLAY
406 C5
407 C6 (35) A
408 C7 (39) B A
C 2B B
F
(G3) D 2G G
CAR DISPLAY BOARD CALLS 8-15 (G2) E
(OPTIONAL) 409 C8 (2G) (G1) F BATTERY
**CALLS 8-15

2C E C
(G0) G
410 C9 (G)-G0 (-) D 12V 1.2AH
411 C10 (F)-G1
(31) 2G
(1)
-
+ SPEAKER
(32) 2C
PROGRAMMABLE 412 C11 (E)-G2
RELAY OUTPUT BOARD 413 C12 (D)-31
*SDC (+)
COM
(OPTION)
(OPTIONAL) 414 C13 (C)-32
B 415 C14 (B)-39 B
EOR CC7D 416 C15 (A)-35
DISP

GONG
INPUTS
O1
O2
O3
O4

O5
O6
O7
O8
C1

C2

COM

(HELP)
KO
KA
KK
O1
I1
I2
I3
I4
I5
I6
I7
I8

2
1

CAR ALARM

MP

HP+
AC
AC

DD
1

HP-
A+
- +

A-
BUTTON
DTS/I7
MO/I1

K20/I6
869/I2
501/I3
500/I4
804/I5

I8

VOLUME
COMMON

COMMON
O1
O2
O3
O4

O5
O6
O7
O8

AB
EIK-2 AB
EMERGENCY
LAMP
INPUTS

35
BOARD AL
AL 12V/MAX. 5W
35 : Over load lamp -
12V
** CALLS 8-15: These terminals are used as call inputs, gray code output or 7 + 12V DC
A segment digital display output depending on number of stops. A
Between C8 and C15 terminals can used as gray code outputs or 7 segment display
output if system is less 8 stops. F/7.5.5.02.69
*SDC : SDC board is used as 7 segment digital display output above 8 stops.
G0, G1, G2,G3 : Optional gray code outputs. This document is a sample for applications. All information contained in SERIAL COMMUNICATION INSPECTION BOX
these materials are subject to change by Aybey Elektronik without notice.
SERIES ACT DRW. M. AKKUS
Aybey Elektronik assumes no responsibility for any damage, liability, or AYBEY
PROJ. ACT026 APPRV. M. AYBEY
other loss rising from these inaccuracies or errors. ELEKTRONİK
REV. 05 DATE 15 MAY 13

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

LAMP TRAVEL
SOCKET INSPECTION SAFETY
(SOCKET) ALARM 220V AC BUTTON
220V AC
SWITCH UP DOWN START STOP PARACHUTE
3 4 CONTACT
1 2
3 4 3 4
4 3 1 2
D 3 4 D
1 2

4 1 (Phase) 220V
5 Mp (Neutral) AC
115
116 SAFETY
117 LINE
120
+100
24V DC
-1000
CH0 SERIAL
CL0 COMMUNICATION
(+) LINE
(HELP) (-) 12V DC
SPEAKER EMERGENCY
CAR ALARM +
C
BUTTON SPK+ BATTERY - LAMP C

- (0V)
+12V

CH
CL
GND
V+

EL+
CALL SPK-

EL-
BAT-
BAT+
+
BUTTON AB-
BUT AB+ 12V 1.2AH
BUTTON
BUT SES 12V/MAX. 5W
LAMP 401 C0
L+ - +
402 C1

CALLS 0-7
L- *SCF : When AFM (Announcer) board is added to SCE board,
CABIN
CALLS
403
404
405
C2
C3
C4
VOLUME SCE/*SCF SCE board's name changes as SCF board.
406 C5
407 C6 EXTERNAL DISPLAY
C2 (35) A
408 C7 O8 (39) B A
409 C8 (2G) O7
**CALLS 8-15

C 2B B
410 C9 (G)-G0 O6 F
(G3) D 2G
C1 G
411 C10 (F)-G1 (G2) E
412 C11 (E)-G2 O5 (G1) F
O4 (G0) G 2C E C
413 C12 (D)-31 (-)
O3 (31) 2G D
CAR DISPLAY BOARD 414 C13 (C)-32 (1)
O2 (32) 2C
415 C14 (B)-39
(OPTIONAL) O1
416 C15 (A)-35 **SDE *SDC (+)
COM
B (OPTIONAL) B
(OPTIONAL)
(OPTINAL)

PROG.
I12 I4
INPS

PROGRAMMABLE INPUTS I11 I3 *SDC : SDC board is used (for 8 and above stops) for 7 segment display connection. According to
I10 I2 AFM [B38] parameter value, it can give out Gray Code or Binary Code. (Output type is NPN)
RELAY OUTPUT BOARD (OPTIONAL) ANNOUNCER
(OPTIONAL) I9 I1 (OPTIONAL) **SDE : Programmable relay output board. It works parallel with EOR board. C1 terminal is
I-BUTTON Black common terminal of 5 relays on the board (O1...O5). C2 terminal is common terminal of other 3
EOR CC7D READER Gray
IB-
relays on the board (O6,O7,O8). Max. switching current of relays is 100mA.
IB+
(OPTIONAL) INPUTS NOTE: SDC and SDE boards can't t be used together on SCE board.
COM

KO
KA
KK
DISP

O1
I1
I2
I3
I4
I5
I6
I7
I8

2
1
O1
O2
O3
O4

O5
O6
O7
O8
C1

C2

(Cabin Lamp)
I1-1/MO
I2-3/869
I3-13/501
I4-12/500
I5-7/804
I6-4/K20
I7-5/DTS
I8-0/FREE

O1-65/OVERLOAD LAMP

2
COM1

COM2

OPN (Open) AUTOMATIC DOOR


O1
O2
O3
O4

O5
O6
O7
O8

INPUTS DCM (Com) BOARD SIGNALS


** CALLS 8-15: These terminals are used as call inputs, gray code output or 7 segment CLS ( Close)
digital display output depending on number of stops.
A Between C8 and C15 terminals can used as gray code outputs or 7 segment display 35 : Overload Lamp A

output if system is less 8 stops.


Set the PRMT. B38-( CAR DISPLAY OUTPUT) F/7.5.5.02.69
Signal Lamps SCE BOARD WITH
This document is a sample for applications. All information contained in
39 : Out of service SERIAL COMMUNICATION INSPECTION BOX
*G0-G1-G2-G3-G4 : Optional Gray Code Outputs. 35 : Overload
these materials are subject to change by Aybey Elektronik without notice.
SERIES ACT DRW. M. AKKUŞ
*B0-B1-B2-B3-B4 : Optional Binary Code Outputs. 32 : Up arrow Aybey Elektronik assumes no responsibility for any damage, liability, or AYBEY
24V DC PROJ. ACT026 APPRV. M. AYBEY
max. 2W 31 : Down arrow other loss rising from these inaccuracies or errors. ELEKTRONİK
REV. 10 DATE 19 OCT 16
1 2 3 4 5 6 7 8
1 2 3 4

AC AC
CONTROLLER-1 CONTROLLER-2
H H

16 WIRES FLAT DATA CABLE

CSI
CAN1

CSI

CAN1
CH

CH
CL

CL
AC AC
COMMUNICATION

COMMUNICATION
Board Board
GROUP

(CALLS) (CALLS)

GROUP
1N5408
G G
1N5408

GROUP
8
PANEL

7 8

GROUP
PANEL
7
6 9 6 9
5 10 5 10
4 11 4 11

ON
ON

ON
ON
3 12 3 12
13

DK100
DK100

2 2 13
1 GPC 14 1 GPC 14

1000
1000

0 15 15
100

100
C14
C10
C11
C12
C13

C15

C14
C10
C11
C12
C13

C15
C0

C2
C1

C3
C4
C5
C6
C7
C8
C9

C0

C2
C1

C3
C4
C5
C6
C7
C8
C9
CL1
CH1
CH1

CL1

GROUP
COMMUNICATION
CABLE

401
402
403
404
405
406
401
402
403
404
405
406

CABIN CALLS
F F
CABIN CALLS

NOTE : Cabin and landing call button


connections are suitable for parallel system in
this drawing.
UP B- L+
UP
Cabin calls are connected to cabin
DOWN B+ L-
DOWN communication board if system is cabin serial
BUSY landings parallel.
BUSY
INS.
INS.

FLOOR 5 FLOOR 5
E E
WARNING !
For group lifts according to EN81-1 and EN81-2
B- L+ matter 14.2.4.3:
UP B+ L- NOTE:For groups of lifts, position indicators on
UP
DOWN B- L+ DOWN
the landings are not recommended.
BUSY B+ L- BUSY However, it is recommended that the arrival of a
INS.
INS. car be preceded by an audible signal.
FLOOR 4 FLOOR 4
Connections on this diagram are for full collective
systems.
D
For simple collective, simple push-button and D
UP
B- L+ one-way collective systems connect only one button.
B+ L- UP
DOWN
DOWN
BUSY B- L+
BUSY
INS. B+ L-
INS.

FLOOR 3 FLOOR INDICATOR


FLOOR 3

UP
UP
DOWN
B- L+ DOWN
BUSY B+ L-
C BUSY C
INS. BUSY
INS.
B- L+
FLOOR 2 B+ L-
FLOOR 2
OUT OF
SERVICE

UP : Up Arrow (32)
DOWN : Down Arrow (31)
UP BUSY : Busy (12)
UP
DOWN
BUSY B-
DOWN INS. : Out Of Service (39)
L+ BUSY
INS. B+ L-
INS.
B- L+
B
FLOOR 1 B+ L- FLOOR 1
B- L+ UP CALL B
B+ L- BUTTON

B- L+ DOWN CALL
B+ L- BUTTON
CALL
BUTTON
B+ 401
BUTTON
B- 1000
UP LAMP
B- DOWN L+ DK100
L+
BUSY L-
UP B+ L-
DOWN INS.
BUSY

A
INS. BOTTOM FLOOR F/7.5.5.02.67
A
BOTTOM FLOOR This document is a sample for applications. All information contained in AC DUPLEX CONNECTIONS
these materials are subject to change by Aybey Elektronik without notice.
SERIES AC DRW. M. AKKUŞ
Aybey Elektronik assumes no responsibility for any damage, liability, or AYBEY
other loss rising from these inaccuracies or errors. PROJ. AC033 APPRV. M. AYBEY
ELEKTRONİK
REV. 01 DATE 06 JULY 11

1 2 3 4
1 2 3 4

CONTROL CONTROL CONTROL CONTROL


PANEL-1 PANEL-2 PANEL-3 PANEL-4

COMMUNICATION CH0
COMMUNICATION CH0

COMMUNICATION CH0

COMMUNICATION CH1
COMMUNICATION CH1

COMMUNICATION CH1

COMMUNICATION CH0

COMMUNICATION CH1
H H

SERIAL
SERIAL

SERIAL
SERIAL

GROUP
GROUP

GROUP
GROUP

1000

1000
1000

1000

CL0

CL0
CL0

CL0

CL1

CL1
CL1

CL1

100

100
100

100
G G
black
red

green
yellow

black

black
red

black
red
green

green

green
yellow

yellow

yellow
red
GND

GND
V+

CL
CH

GND

V+

CL
CH

GND
V+

CL
CH

V+

CL
CH
FLOOR 3 FLOOR 3 FLOOR 3 FLOOR 3
CFU

CFU
CFU

CFU
OUT OF
SERVICE
OUT OF
SERVICE
OUT OF
SERVICE
SDS
UP ARR B- L+ UP ARR UP ARR B- L+
Y.OK
F HP DOWN ARR HP DOWN ARR HP DOWN ARR HP A.OK F
HP
BUSY B+ L- HP BUSY
HP
BUSY B+ L- HP MS
DB-

DB-
DL-
UB-
UL-

DB-

DL-
UB-
UL-

DB-
32
31

DL-
UB-
UL-

32
31

DL-
UB-
UL-
32
31

32
31
B+

B+
L+

B+

L+

B+
L+

L+
GND

GND
V+

CL
CH

GND

V+

CL
CH

GND
V+

CL
CH

V+

CL
CH
FLOOR 2 FLOOR 2 FLOOR 2
FLOOR 2
CFU

CFU
CFU

CFU
E B- L+ B- L+ E
OUT OF OUT OF OUT OF OUT OF
SERVICE B+ L- SERVICE SERVICE B+ L- SERVICE
UP ARR UP ARR UP ARR UP ARR
HP DOWN ARR HP DOWN ARR HP DOWN ARR HP DOWN ARR
HP BUSY
B- L+ HP HP BUSY
B- L+ HP
BUSY BUSY
B+ L- B+ L-
DB-

DB-
DL-
UB-
UL-

DB-

DL-
UB-
UL-

DB-
32
31

DL-
UB-
UL-

32
31

DL-
UB-
UL-
32
31

32
31
B+

B+
L+

B+

L+

B+
L+

L+
D D
GND

GND
V+

CL
CH

GND

V+

CL
CH

GND
V+

CL
CH

V+

CL
CH
FLOOR 1 FLOOR 1 FLOOR 1 FLOOR 1
CFU

CFU
CFU

CFU
OUT OF B- L+ OUT OF
B- L+
OUT OF OUT OF
SERVICE B+ L- SERVICE SERVICE B+ L- SERVICE
UP ARR UP ARR UP ARR UP ARR
HP DOWN ARR HP DOWN ARR HP DOWN ARR HP DOWN ARR
HP BUSY B- L+ HP BUSY HP BUSY B- L+ HP BUSY
B+ L- B+ L-
DB-

DB-
DL-
UB-
UL-

DB-

DL-
UB-
UL-

DB-
32
31

DL-
UB-
UL-

32
31

DL-
UB-
UL-
32
31

32
31
B+

B+
L+

B+

L+

B+
L+

L+

C C
GND

GND
V+

CL
CH

GND

V+

CL
CH

GND

BOTTOM
V+

CL
CH

V+

CL
CH

FLOOR BOTTOM BOTTOM


BOTTOM
CFU

CFU
CFU

CFU

FLOOR FLOOR
OUT OF OUT OF OUT OF OUT OF
FLOOR
SERVICE SERVICE SERVICE SERVICE
UP ARR UP ARR UP ARR UP ARR
HP DOWN ARR
B- L+ HP DOWN ARR HP DOWN ARR
B- L+ HP DOWN ARR
HP BUSY B+ L- HP BUSY HP BUSY B+ L- HP BUSY
DB-

DB-
DL-
UB-
UL-

DB-

DL-
UB-
UL-

DB-
32
31

DL-
UB-
UL-

32
31

DL-
UB-
UL-
32
31

32
31
B+

B+
L+

B+

L+

B+
L+

L+

B B

WARNING ! DB-
For group lifts according to EN81-1 and EN81-2 DL- CALL
CH UB-
article 14.2.4.3: CL CDH UL-
B+
BUTTON
B+ B+
NOTE:For groups of lifts, position indicators GND L+ BUTTON
B- UB-/DB-
on the landings are not recommended. V+ 39
OUT OF SERVICE (39) LAMP
HP

However, it is recommended that the 32 L+ L+


31 UP ARROW (32) L- UL-/DL-
arrival of a car be preceded by an 12
DOWN ARROW (31)
audible signal. BUSY (12)
CDH Board Button connections are the same with CFU board.
F/7.5.5.02.67
A
Connections on this diagram are for A
full collective systems. SERIAL COMMUNICATION GROUP LIFT
This document is a sample for applications. All information contained in LANDING PUSH-BUTTON CONNECTIONS
For simple collective, simple push-button and these materials are subject to change by Aybey Elektronik without notice. DRW. M. AKKUŞ
one-way collective systems Aybey Elektronik assumes no responsibility for any damage, liability, or AYBEY SERIES AC
connect only one button. PROJ. AC037 APPRV. M. AYBEY
other loss rising from these inaccuracies or errors. ELEKTRONİK
REV. 01 DATE 01 SEP 15

1 2 3 4
1 2 3 4 5 6 7 8

LINE AC SERIES SAFETY LINE FOR INSPECTION BOX AND EMERGENCY ELECTRICAL OPERATOR
PE N/Mp L1/R
MACHINE ROOM EMERGENCY ELECTRICAL
OPERATOR SYSTEM CONNECTION OKK : Cabin Door Contact.

1000
TRANSFORMER

869
870

550
551

501

500
220V
EMERGENCY ELECTRICAL KK : Landing Doors Lock.
OV

OPERATOR SWITCH Up Motion

100W
D
Button D
STOP
0V

220V
230V
1.3 1.4 1.3 1.4

(OPTIONAL) 2.3 2.4 2.3 2.4


FWCX-1A

1 2 Down Motion
Button

1.3 1.4

2.3 2.4
4

FTKR GROUND FAULT


3

BREAKER
(30mA)

CIRCUIT

120

130

140
117
C C
111

112

114

115

116
113
150

110

Counter Weight

STOP
Cabin Cabin Roof Exit Door
Buffer Contact

Parachute
Well Limit

Contact
Stop Up
Governor Contact

Cabin Door Contact

Top Floor
KK...n
Emergency Stop
Machine Room

OKK-1
Overspeed

STOP Contact
Well Limit
Stop Down

Cabin Buffer
Contact

Middle Floors
KK-n
Overspeed Governor
Tensioning Weight
Loose Rope
Contact

B B
Rope

Cabin Top
STOP

Bottom Floors
Inspection Motion

KK1
INSPECTION Safety Button
START
SWITCH 3 4
STOP

Up
Pit

1.1 1.2
Button
3 4
3 4
2.1 2.2
Down
Button

3 4
A A

F/7.5.5.02.67
INSPECTION BOX ACT SERIES SAFETY LINE CONNECTIONS
This document is a sample for applications. All information contained in DOOR TYPE : AUTOMATIC DOOR
CONNECTION these materials are subject to change by Aybey Elektronik without notice. DRW. M. AKKUŞ
Aybey Elektronik assumes no responsibility for any damage, liability, or AYBEY SERIES AC
PROJ. AC196 APPRV. M. AYBEY
other loss rising from these inaccuracies or errors. ELEKTRONİK
REV. 04 DATE 21 JUN 16
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

LINE AC SERIES SAFETY LINE FOR INSPECTION BOX AND EMERGENCY ELECTRICAL OPERATOR
PE N/Mp L1/R
MACHINE ROOM EMERGENCY ELECTRICAL FK : Landing Door Contacts
OPERATOR SYSTEM CONNECTION KK : Landing Door Locks

1000
TRANSFORMER

869
870

550
551

501

500
220V
EMERGENCY ELECTRICAL 135* : This input is used in cabin door automatic landing
OV

OPERATOR SWITCH Up Motion doors manual systems.


100W
D
Button D
STOP If automatic cabin door is not used, 130 and 135
terminals must be short-circuited.
0V

220V
230V
1.3 1.4 1.3 1.4

(OPTIONAL) 2.3 2.4 2.3 2.4


FWCX-1A

1 2 Down Motion
Button

1.3 1.4

2.3 2.4
4

FTKR GROUND FAULT


3

BREAKER
(30mA)

CIRCUIT

135*
130

140
120
117
C C
111

112

114

115

116
113
150

110

Counter Weight

STOP
Cabin Cabin Roof Exit Door
Buffer Contact

Parachute
Well Limit

Contact
Stop Up
Governor Contact

Top Floor
TOP Floor

KK...n
FK...n
Emergency Stop
Machine Room

Overspeed

Cabin Door Contact


STOP Contact
Well Limit
Stop Down

Cabin Buffer

Middle Floors

Middle Floors
Contact

FK-n

KK-n
Overspeed Governor
Tensioning Weight
Loose Rope
Contact

B B
Rope

Cabin Top
STOP

Bottom Floors
Bottom Floor

KK1
Inspection Motion

FK1
INSPECTION Safety Button
START
SWITCH 3 4
STOP

Up
Pit

1.1 1.2
Button
3 4
3 4
2.1 2.2
Down
Button

3 4
A A

F/7.5.5.02.67
INSPECTION BOX AC SERIES SAFETY LINE CONNECTIONS
This document is a sample for applications. All information contained in DOOR TYPE : SWING DOOR
CONNECTION these materials are subject to change by Aybey Elektronik without notice. DRW. M. AKKUŞ
Aybey Elektronik assumes no responsibility for any damage, liability, or AYBEY SERIES AC
PROJ. AC196 APPRV. M. AYBEY
other loss rising from these inaccuracies or errors. ELEKTRONİK
REV. 03 DATE 21 JUN 16
1 2 3 4 5 6 7 8
1 2 3 4

d1 : The distance between two magnets in case there is


not rail between them.
7 d2 : The distance between magnet and magnetic shalter.
H H
d1 = min.100mm d2
d2 = 10-30 mm
KSR2 818
COMPULSORY
TOP LIMIT M?
CAR SWITCH
AT TOP d1 d2

MK
6 M0
Rail

G G
Magnet

BLACK SIDE OF MAGNET

RED SIDE OF MAGNET


5

F
818 F

818/KSR2

817

4 817/KSR1

USE MECHANICAL SHALTERS AS


1000 817 (KSR1) AND 818(KSR2) LIMIT SWITCHES
E E

MK
3
MK
UP COUNTER MAGNET
M0

D
M0 D
DOWN COUNTER MAGNET

1000
2
M0 AND MK ARE BI-STABLE SHALTERS

M0 AND MK ARE TRANSMITTED FROM


CAR TOP TO CONTROL PANEL BY FLEX CABLE

LOCATE MAGNETS AS IN THE FIGURE


C C
ACCORDING TO NUMBER OF STOPS
AUTOMATIC DOOR
OPEN ZONE 1
CAR
AT BOTTOM COMPULSORY
BOTTOM LIMIT
SWITCH
KSR1 817
B
! DO NOT USE MK SHALTER IN ONE SPEED SYSTEM B

M0
0 IF NO AUTOMATIC DOOR IS USED
MK
818
817
MK

M0
COUNTER

!
STOPPER

F/7.5.5.02.67
A A
This document is a sample for applications. All information contained in COUNTER SYSTEM MAGNET MAP
these materials are subject to change by Aybey Elektronik without notice. WITH LIMIT SHALTERS
SERIES AC DRW. M. AKKUŞ
Aybey Elektronik assumes no responsibility for any damage, liability, or AYBEY
other loss rising from these inaccuracies or errors. PROJ. AC003 APPRV. M. AYBEY
ELEKTRONİK 00
REV. DATE 22 JUN 12

1 2 3 4
1 2 3 4

d1 : The distance between two magnets in case there is


not rail between them.

5 d2 : The distance between magnet and magnetic shalter.


d2
H H
COMPULSORY
TOP LIMIT d1 = min.100mm
SWITCH
d2 = 6-15 mm M?
KSR2 818
d1 d2
CAR ML2
AT TOP ML2 MKD
MKD
ML1
100 ML1 Rail
MKU MKU
1000

G Magnet G

UP STOPPER
818
MAGNET
DOWN STOPPER 4
MAGNET 818/KSR2
817

817/KSR1

1000
USE MECHANICAL SWITCHES
F F
AS 817 (KSR1) AND 818(KSR2) LIMIT SWITCHES

Stopping Distance AYBEY KPM 206 MONO STABLE MAGNET SWITCH


in Down Direction
Stopping Distance 3 Plase strip magnet in front of ML1 and
ML2 switches.
CONTACT
STATE
in Up Direction
Slowing Distance
MAGNET 'N' POLE

30cm
in Up Direction
(Strip Magnet)
UP DIRECTION
COUNTER MAGNET
E NO MAGNET E
DOWN DIRECTION
COUNTER MAGNET
MAGNET 'S' POLE
Slowing Distance (Strip Magnet)
in Down Direction

SAFE ZONE LIMIT


ML2
FOR RELEVELLING 2 ML2
ML1
100 ML1
D D

ML1 and ML2 Floor level sensors that detect the


unlocking zone must comply with EN81-1 and
EN81-2 article14.1.2.5
CONTACT
STATE
15cm
FOR AUTOMATIC
10cm

MAGNET 'N' POLE


DOOR OPEN
ZONE LIMIT
1 (Strip Magnet)

NO MAGNET
C C
10cm
10cm

CAR MAGNET 'S' POLE


AT BOTTOM (Strip Magnet)

MKU
10cm KSR1 817
COMPULSORY
BOTTOM LIMIT MKU
SWITCH MKD

B 30cm
15cm 10cm
10cm
0 MKD B

1000
ML2
MKD MKU ML1, ML2, MKU AND MKD ARE PLACED ON
817
818

ML1
CARTOP FOR HIGHER NUMBER OF STOPS THE
MKU COUNTER
MKD COUNTER
ML2
ML1

MAP REPEATS ITSELF.


STOPPER

UP
STOPPER

DOWN

SAFE ZONE LIMIT F/7.5.5.02.67


A SENSOR FOR OPEN AC SERIES COUNTER SYSTEM MAGNET
A
DOOR LEVELLING This document is a sample for applications. All information contained in LOCATION MAP WITH MONO-STABLE SWITCHES
AND RELEVELLING. these materials are subject to change by Aybey Elektronik without notice. DRW. M. AKKUŞ
AYBEY SERIES AC
AND

Aybey Elektronik assumes no responsibility for any damage, liability, or


AND

PROJ. AC180 APPRV. M. AYBEY


other loss rising from these inaccuracies or errors. ELEKTRONİK
REV. 00 DATE 20 JUN 12

1 2 3 4
1 2 3 4

d1 : The distance between two magnets in case there is


no rail between them.
5 d2 : The distance between magnet and magnetic shalter.
d2
H H
COMPULSORY
TOP LIMIT d1 = min.100mm
SWITCH
d2 = 6-15 mm M?
KSR2 818
d1 d2
CAR AT ML2
ML2 MKD
TOP MKD
ML1
100 ML1
MKU
Rail
1000
MKU

G G
Magnet
UP STOPPER
818
MAGNET
DOWN STOPPER 4
MAGNET 818/KSR2
UP DIRECTION 817
DECELERATION
DISTANCE
817/KSR1
DECELERATION 2
(K7-GENERAL PULSE)
1000
USE MECHANICAL SWITCHES
F F
DOWN DIRECTION AS 817 (KSR1) AND 818(KSR2) LIMIT SWITCHES
DECELERATION
DISTANCE

UP RELEVELING AYBEY KPM 206 MONO STABLE MAGNET SWITCH


MAGNET
DOWN RELEVELING 3 Place strip magnet in front of ML1 and
ML2 switches.
CONTACT
STATE
MAGNET

MAGNET 'N' POLE

30cm
(Strip Magnet)

E NO MAGNET E

MAGNET 'S' POLE


(Strip Magnet)

SAFE ZONE LIMIT ML2


FOR RELEVELLING 2 ML2
ML1
100 ML1
D D

ML1 and ML2 Floor level sensors that detect the


unlocking zone must comply with EN81-2 article
14.1.2.5
CONTACT
15cm STATE
10cm

FOR AUTOMATIC 10cm MAGNET 'N' POLE


DOOR OPEN
ZONE LIMIT 10cm
1 (Strip Magnet)

NO MAGNET
C C
10cm

CAR AT MAGNET 'S' POLE


BOTTOM (Strip Magnet)

KSR1 817 MKU


COMPULSORY
BOTTOM LIMIT
MKU
SWITCH
MKD
B 30cm
15cm 10cm
10cm
0 1000 MKD B

ML2
MKD MKU
817
818

ML1
MKU
MKD
ML2
ML1

ML1, ML2, MKU AND MKD ARE PLACED ON CARTOP.


FOR HIGHER NUMBER OF STOPS THE MAP REPEATS ITSELF. (PRM-A05:006)
SAFE ZONE LIMIT F/7.5.5.02.67
STOPPER
STOPPER

A SENSOR FOR A
DOWN

DOOR-OPEN ENCODER COUNTER WITH MONO-STABLE


UP

This document is a sample for applications. All information contained in SHALTER CONNECTION DIAGRAM
LEVELLING AND these materials are subject to change by Aybey Elektronik without notice. DRW. M. AKKUŞ
RELEVELLING. Aybey Elektronik assumes no responsibility for any damage, liability, or AYBEY SERIES AC
PROJ. AC202 APPRV. M. AYBEY
other loss rising from these inaccuracies or errors. ELEKTRONİK
REV. 00 DATE 16 JULY 13

1 2 3 4
1 2 3 4

d1 : The distance between two magnets in case there is


not rail between them.
30cm d2 : The distance between magnet and magnetic shalter.
d2
H 4cm 7 H
COMPULSORY d1 = min.100mm
TOP LIMIT M?
SWITCH d2 = 6-15 mm
KSR2 818 d1 d2
ML2
ML2
CAR ML1-2
AT TOP ML1
100 ML1
MK
Rail
1000 MK

6 Magnet
G UP DIRECTION G
DECELERATION
DISTANCE
818 818/KSR2
DECELERATION-2
(K7-GENERAL PULSE)
817 817/KSR1
DOWN DIRECTION
DECELERATION
DISTANCE USE MECHANICAL SHALTERS AS
5 1000 817 (KSR1) AND 818(KSR2) LIMIT SWITCHES

AYBEY KPM 206 MONO-STABLE MAGNETIC SHALTER


F F
Strip magnet is placed for ML1, ML2 and STATE
MK magnetic shalters. CONTACT

30cm
'N' POLE OF MAGNET
(30cm strip magnet)

NO MAGNET
SAFE ZONE LIMIT
FOR RELEVELING 4

30cm
'S' POLE OF MAGNET
(30cm strip magnet)

E NO MAGNET E

'N' POLE OF MAGNET 8cm


(Strip magnet)

NO MAGNET
4cm
3 'S' POLE OF MAGNET 8cm
(Strip magnet)

ML2
ML2
D
ML1 D

100 ML1
MK
30cm 8cm 2 1000 MK
ENCODER ML1 and ML2 Floor level sensors that detect the unlocking
ROPE
zone must comply with EN81-1 and EN81-2 article14.1.2.5

SHAFT ENCODER
ENCODER ROPE
C C
TOP SHAFT
15cm CABIN ENCODER
DOOR OPEN ZONE

K7-GENERAL PULSE
1 ENCODER CONNECTION
DOOR ZONE PANEL
CAR ENKODER (NEMICON)
100 Pulse
AT BOTTOM 5-30V DC
CABIN VCC
(Red)
100
(Black)
GND
(Blue)
1000
KSR1 817 A
B (White) E1/ENA
B COMPULSORY E2/ENB B
BOTTOM LIMIT
SWITCH Earth
4cm
15cm
0 WARNING !!!
30cm If parameter A17-UCM CONTROL : 4 then locate ML1 and ML2 shalters approriate
818
817

ML2 with schematics.


If parameter A17-UCM CONTROL : 3 and preopening door and releveling functions
ML2
ML1

ML1 aredisabled then do not use ML1 and ML2 shalters.

MK
ML1, ML2 AND MK ARE PLACED ON CARTOP FOR HIGHER NUMBER OF STOPS (PRM-A05:003)
MK

THE MAP REPEATS ITSELF.


SAFE ZONE LIMIT F/7.5.5.02.67
A A
SENSOR FOR OPEN SHAFT ENCODER MAGNET LOCATION DIAGRAM
This document is a sample for applications. All information contained in
DOOR REVELELING FOR PRE-OPENING DOOR
these materials are subject to change by Aybey Elektronik without notice.
AND RELEVELING. SERIES AC DRW. M. AKKUŞ
Aybey Elektronik assumes no responsibility for any damage, liability, or AYBEY
other loss rising from these inaccuracies or errors. PROJ. AC146 APPRV. M. AYBEY
ELEKTRONİK
REV. 01 DATE 20 JUN 12
1 2 3 4
1 2 3 4 5 6 7 8

AC SERIES CONTROL PANEL SAFETY LINE


D PIT STOP D

110

111
OVERSPEED GOVERNOR
112
NC
113
Overspeed Governor
Door Contacts NC
120 Safety Contact
120
CONTROL BOARD 130 Landing Door Locks
130
SAFETY LINE
140
140

C C

SG1 SG1
OVERSPEED GOVERNOR Overspeed
A3 CONTROL COIL SUPPLY SG2 SG2 Governor
A3 Coil

SGO : Programmable Input Code 53 SGO


*SGO : Overspeed Governor A3 1000
Coil Checking Input
SGO SGO NO
(INPS Board I1 Input) *SGO
Overspeed Governor A3 Coil
SGC Control Contacts
140
NC
B B
141 SGC
**141
**141 : Contactor Supply
Terminal
100

ML1 ML1

ML2 ML2

ML1-ML2 : Door Zone Switches

M2-PARAMETERS
A P1- MAIN PARAMETERS A

A17 : UCM CONTROLLER / 004 (SPEED GOVERNOR-1) F/7.5.5.02.67

This document is a sample for applications. All information contained in OVERSPEED GOVERNOR (A3 TYPE) CONNECTIONS
these materials are subject to change by Aybey Elektronik without notice.
SERIES AC DRW. M. AKKUŞ
Aybey Elektronik assumes no responsibility for any damage, liability, or AYBEY
other loss rising from these inaccuracies or errors. PROJ. AC192 APPRV. M. AYBEY
ELEKTRONİK
REV. 03 DATE 15 SEP 14

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

AC SERIES CONTROL PANEL

PE PE GEARLESS MACHINE
D D
U U

V V Motor
Coils
W W

2000 BR
2000
840 BRAKE-1
840 BR
COIL
BRAKE COILS
2000 1NC
SUPPLY CIRCUIT 2000
840 1C NC BRAKE-1
840 C
CONTROL CONTACT
C 1NO NO C

(INPS Board I1-Input) BR1


CONTROL BOARD BR1
BRAKE CONTROL BR2 BR
(INPS Board I2-Input)
FEEDBACK INPUTS BR2
BRAKE-2
1000 BR
COIL
1000
2NC
2C NC BRAKE-2
C
CONTROL CONTACT
2NO NO
BR1: Programmable Input Code 50: (Brake Contact 1)
BR2: Programmable Input Code 51: (Brake Contact 2)
T1 TR
*T1
B T2 TR THERMISTOR B
*T2

*T1-T2 : Motor Temperature


Monitoring Circuit
100

ML1 ML1

ML2 ML2

ML1-ML2 : Door Zone Switches

M2-PARAMETERS
P1- MAIN PARAMETERS
A A
A17 : UCM CONTROLLER / 003 (GEARLESS) F/7.5.5.02.69

This document is a sample for applications. All information contained in GEARLESS MACHINE (A3 TYPE)
these materials are subject to change by Aybey Elektronik without notice. CONNECTION DIAGRAM
SERIES ACT DRW. M. AKKUŞ
Aybey Elektronik assumes no responsibility for any damage, liability, or AYBEY
other loss rising from these inaccuracies or errors. PROJ. ACT193 APPRV. M. AYBEY
ELEKTRONİK
REV. 01 DATE 15 OCT 12

1 2 3 4 5 6 7 8
1 2 3 4

PARALLEL SYSTEM PI CALL REGISTER BOARD CONFIGURATIONS


ACB
(Jumper Settings) (Jumper Settings)
J1 J1

UART
SP1
PB
J2

26

26
J2

26

26

26
16
H J3 J3 H
J4 J4

150 16
UART Parallel Bus

100
PI

1000
120 10AC
PI
CNT
N/Mp

Driver
L2/S
S41
S44

L1/R
L3/T

SP1
130
140
151
ML2 ACT

INPUTS & SIGNAL


ML1

L10
L11
L12
L13
L14
L15
L10
L11
L12
L13
L14
L15

100 L0
1000 L1
L2
L3
L4
L5
L6
L7
L8
L9
100 L0
1000 L1
L2
L3
L4
L5
L6
L7
L8
L9
S14
S11
LCD

40
G G
R
2
HXKL

KA
KO 24V DC
KK ESC ENT 100
RU 1000
REV/ INSP.
RD
I
RH CALLS
RF O
16
VK NORM

F CABIN CALLS : 401-402........400n PI-C PI-C PI-C F

DOWN CALLS : 201-202........200n


C10
C11
C12
C13
C14
C15

C10
C11
C12
C13
C14
C15
C10
C11
C12
C13
C14
C15
UP CALLS : 301-302........300n
C8
C9

C8
C9
C0
C1
C2
C3
C4
C5
C6
C7

C8
C9

C0
C1
C2
C3
C4
C5
C6
C7
C0
C1
C2
C3
C4
C5
C6
C7
16 STOP SIMPLE PUSH BUTTON
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416

417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
32 STOP SIMPLE COLLECTIVE
401
402
403
404
405
406
407
408
409
410
411
412
201
202
203
204

205
206
207
208
209
210
211
212
12 STOP DOWN COLLECTIVE
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416

417
418
201
202
203
204
205
206
207
208
209
210
211
212
213
214

215
216
217
218
18 STOP DOWN COLLECTIVE
401
402
403
404
405
406
407
408
301
302
303
304
305
306
307
308

8 STOP UP COLLECTIVE
401
402
403
404
405
406
202
203
204
205
206
301
302
303
304
305

6 STOP FULL COLLECTIVE


E E
401
402
403
404
405
406
407
408
409
410
202
203
204
205
206
207

208
209
210
301
302
303
304
305
306
307
308
309
10 STOP FULL COLLECTIVE
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416

202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
301

302
303
304
305
306
307
308
309
310
311
312
313
314
315
16 STOP FULL COLLECTIVE

CABIN SERIAL AND LANDING PARALLEL SYSTEM PI CALL REGISTER BOARD CONFIGURATIONS
ACB
(Jumper Settings) (Jumper Settings)
J1 J1
UART
SP1
PB

J2
26

26

J2
26

26

26
16

J3 J3
J4 J4

150 16
D UART Parallel Bus D
100

PI
1000

120 10AC
PI
CNT
N/Mp

Driver
L2/S
S41
S44

L1/R
L3/T

SP1
130
140
151
ML2 ACT
INPUTS & SIGNAL

ML1
L10
L11
L12
L13
L14
L15
L10
L11
L12
L13
L14
L15

100 L0
1000 L1
L2
L3
L4
L5
L6
L7
L8
L9
100 L0
1000 L1
L2
L3
L4
L5
L6
L7
L8
L9

S14
S11
LCD
40

R
2
HXKL

KA
C KO 24V DC C
KK ESC ENT 100
RU 1000
REV/ INSP.
RD
I
RH CALLS
RF O
16
VK NORM

CABIN CALLS : 401-402........400n PI-C PI-C PI-C


DOWN CALLS : 201-202........200n
C10
C11
C12
C13
C14
C15

C10
C11
C12
C13
C14
C15
C10
C11
C12
C13
C14
C15

UP CALLS : 301-302........300n
C8
C9

C8
C9
C0
C1
C2
C3
C4
C5
C6
C7

C8
C9

C0
C1
C2
C3
C4
C5
C6
C7
C0
C1
C2
C3
C4
C5
C6
C7

B B

16 STOP SIMPLE PUSH BUTTON


201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216

217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232

32 STOP SIMPLE COLLECTIVE


201
202
203
204
205
206
207
208
209
210
211
212
213
214

14 STOP DOWN COLLECTIVE


201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216

217
218
219
220
221
222
223
224

24 STOP DOWN COLLECTIVE


301
302
303
304
305
306
307
308
309
310

10 STOP UP COLLECTIVE
202
203
204
205
206
207
208
209
301
302
303
304
305
306
307
308

9 STOP FULL COLLECTIVE


202
203
204
205
206
207
208
209
210
211
212
301
302
303
304
305

306
307
308
309
310
311

12 STOP FULL COLLECTIVE


202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217

218
219
220
221
222
223
224
301
302
303
304
305
306
307
308
309

310
311
312
313
314
315
316
317
318
319
320
321
322
323

24 STOP FULL COLLECTIVE


F/7.5.5.02.67
A A
This document is a sample for applications. All information contained in ACT BOARD I/O CONFIGURATIONS
these materials are subject to change by Aybey Elektronik without notice. AND CONNECTION DIAGRAM
SERIES AC DRW. M. AKKUŞ
Aybey Elektronik assumes no responsibility for any damage, liability, or AYBEY
other loss rising from these inaccuracies or errors. PROJ. AC008 APPRV. M. AYBEY
ELEKTRONİK
REV. 01 DATE 20 JUN 12

1 2 3 4
1 2 3 4 5 6 7 8

SAFETY LINE PARAMETER SETTINGS


M2 : PARAMETERS
SLB SAFETY LINE
P1 : MAIN PARAMETER

Door Contacts
SIGNAL SUPPLY

Door Locks
A06 : PRE OPENING DOORS
SUPPLY 1 ( YES)
24V DC

STOP
D P6 : OUTPUT DEFINE D
(+) (-) O1-50/DOOR BRIDGING
O2-66/SLOW OR STOP
SFR-C SFR-B SFR-A
RSB

110

130

140
120
P7 : INPUT DEFINE
I1-25/FREQUENCY OK

RSB

SF1
SF2
V+

A0
V-
B0
**I1 : PROGRAMMABLE INPUT
***O1-O2 : PROGRAMMABLE OUTPUTS

150

100
1000
10AC

N/Mp
S41

L1/R
CNT

L2/S
L3/T
S44
C 120 C

130
140
VVVF 151

INVERTER ML2
ML1

S14
ACT/ACS
S11
R
2
KA
KO

INPUTS & SIGNAL


B KK B
OUT
(Optional)
Up-FWD

40
RU
Down-REV RD
REV/ INSP.
Fast-X1 INP
RH (OPTIONAL) I

COM
Slow-X2 RF

C4
I4
I3
I2
I1

04

03
02
01
O
Common-CM VK
NORM

25- (FDT) FREQUENCY OK


FDTR

O2-66 /SLOW OR STOP


O1-50-/DOOR BRIDGING
COM
11 12
FDT 1N4007

A2
FDTR A1
24V DC
Relay ML1 and ML2 Floor level sensors that detect the
1000

ML1
ML2
100

A
unlocking zone must comply with EN81-2 A
NOTE: article14.1.2.5
FDTR Relay must be energized when car speed is over 0.3 m/s. F/7.5.5.02.67
FDTR relay is not used when inverter support this relay under the speed 0.30m/s. SLB DOOR BRIDGING BOARD AND PRE-OPENING
This document is a sample for applications. All information contained in DOOR CONNECTIONS WITH INVERTER
ML2

ML1

these materials are subject to change by Aybey Elektronik without notice. DRW. M. AKKUS
Aybey Elektronik assumes no responsibility for any damage, liability, or AYBEY SERIES AC
PROJ. AC016 APPRV. M. AYBEY
other loss rising from these inaccuracies or errors. ELEKTRONİK
REV. 00 DATE 03 MAY 12
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

AC SERIES COMPUTER CONNECTIONS


PARAMETER SETTINGS
AC SERIES *SP : AC Series serial port channels.
CONTROL CARD M2 : PARAMETERS
SP1 (B13 - SERIAL PORT 1)
D *SP SP2 (B14 - SERIAL PORT 2) P2 : AUX. PARAMETERS D
SP3 (B15 - SERIAL PORT 3) B13 : SERI PORT 1
ETH SP4 (B16 - SERIAL PORT 4) Code : 001 (PC COMMUNICATION)
DIRECT COMPUTER CONNECTION *SPx.. : 1 ( PC COMMUNICATION)
USB
B14 : SERI PORT 2
COMPUTER B15 : SERI PORT 3
B16 : SERI PORT 4
RJ45 SOCKET

CONNECTION THROUGH INTERNET

USB CABLE
INTERNET
C C

COMPUTER-1

RJ45
ETHERNET SWITCH
ADSL MODEM

* Internet IP address must be static


B B

LOCAL CONNECTION THROUGH ETHERNET


COMPUTER-N

COMPUTER-1 COMPUTER-N
COMPUTER-2

A A

F/7.5.5.02.67

This document is a sample for applications. All information contained in AC SERIES COMPUTER CONNECTION DIAGRAM
these materials are subject to change by Aybey Elektronik without notice.
SERIES AC DRW. M. AKKUS
Aybey Elektronik assumes no responsibility for any damage, liability, or AYBEY
PROJ. AC109 APPRV. M. AYBEY
other loss rising from these inaccuracies or errors. ELEKTRONİK
REV. 00 DATE 20 JUN 12
1 2 3 4 5 6 7 8