SimPlex™
The New Simplicity in Web Guiding Systems
FEATURES
• Operator Adjustments: • Displays a code to identify the system self-diagnostic
• Automatic status:
• Servo Center • Detector Inputs--Proper range, shorted or open
• Manual Jog signal
• Detector Select--Detector 1, Detector 2, Center- • Actuator--Open or shorted connection, stall
guide condition
• Web Setup (Calibrate detector on Web) • Communications--Interruption
• Gain adjust • Checksum of communications
• International symbols on keypad and display
• Display symbols indicate mode of operation
DIMENSIONS
inches (mm)
47
/
13 1
6 (11 /16
3 .8) 2.7
)
( 6
9
Cable may be routed
out of any one of the four
sides or downward
thru a panel hole.
25/8
(66.7)
Note: The panel cutout size for flush mounting is 4" (101.6)
wide × 33/8" (85.8) high.
SPECIFICATIONS
FEATURES
• Externally trigger servo center through an AC input • Two EIA-485 serial inputs allow remote computer
DeviceNet™ network access to the following features:
• Line run AC input to inhibit automatic operation
• All keyboard functions on H6415-DSP
• Relay contacts (one NO and one NC) provided for • Save/recall "job-specific" settings (detector
annunciation of fault conditions setup, controller gain, and offset)
• Monitor system status codes
• Operator can remotely adjust guide point using locally • Monitor line run AC input status
mounted handheld device • Monitor servo center AC input status
• The controller automatically identifies the type/size
• Select detectors
of actuator connected
• Calibrate detectors
DIMENSIONS
inches (mm)
Door swing
73/4
7 8) (196.8)
7.
1 1
( 7 (30 12
3 1
1
6 4
9 7
2 2
4.8
)
5
/16 (7.9)
9
Customers (228.6)
power line 6 1/
47/8 (165 2
.1)
(123.8)
(35 14
5.6
) 7
/8 (22.2) dia.
15
(38 4 / .3) conduit knockout
1 2
1) 4
(11 7 )
7.8
(17
115/230
H6425-AMP-00
/16 (7.9) dia.
5
37/8
4 mounting holes (98.4)
SPECIFICATIONS
Model Number: H6425-AMP-00 Frequency Response: –3dB at 20 Hz
Power Requirements: 102-132 or 204-264 V ac Fault / Alarm Contacts: (1) Normally open and
Switch selectable (1) Normally closed
50-60 Hz, 400 VA max Rated 1 A at 230 V ac
Actual Power Output: 300 watts continuous
Power Output (to detectors): 15 V dc at 150 mA
Pulse width modulated
AC Input (Line Run Relay, Servo Center) Housing Material: Anodized aluminum
Input: 102-264 V ac
Input Impedance: 28 kΩ Size: 15" (381) L × 7" (177.8) W × 47/8" (123.8) H
Maximum input allowed for no output: 70 V ac,
2.5 mA Weight: 16.1 lb (7.3kg)
Allowable Ambient Temperature: 0-50 C (32-122 F) Serial Ports: (2) EIA-485 (RS485)
Bulletin 10028/10.00 Page 3
Bulletin 10028/10.00
Page 4
FEATURES
• Offsets ±35% of field of view
/
7 8
2/1 2
(22.2)
(63.5) • Light and compact for ease-of-use
• Plug-in connection
5
(127)
SPECIFICATIONS
Power Requirements: 5 V dc
Potentiometer Value: 1 kΩ to 10 kΩ
Dimensions
Cable Length: 15 ft cable
inches (mm)
Extension Cable (15 ft): H6415-DETEXT-15
DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSTION, INC.
IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL.
ACCESSORIES