Вы находитесь на странице: 1из 48

Towards leadership

through commitment

Reliable Range of AC Induction Motors


ISO 9001 - 2008

Motors, Encoder Motors and other special motors as


per the customer’s specifications.
General Engineering,
Material Handling Process Plants & Refineries

Machine Tools & Machinery Power Sector

Steel Plants & Forging Paper, Textile, Packaging


LHP - Motors & Drives. In every corner of India
and in almost every industry.

Faridabad

Ranchi
Rourkela

National Sales & Marketing Office Lhp / MKTG/WI7205/REV-8/01-05-12

Corporate office & manufacturing plant National Sales & Marketing office
Laxmi Hydraulics Pvt. Ltd. Laxmi Hydraulics Pvt. Ltd.
B-11, M.I.D.C. Chincholi, Solapur- 413255 INDIA A 502, G.O. Square, Wakad, Jagtap Dairy Road,
Tel.: +91-217-2357001 Fax : 2357006, Pune - 411057 Maharashtra - INDIA
Email : lhpindia@lhpmotor.com www.lhp.co.in Tel.: +91 9921488299 (Board)
Greetings to all. Quick Selection Guide to
With a glowing
heritage of 30 years,
LHP is an established
and recognised brand
of Motors & Drives
in India.

LHP provides a wide


range of products
and undertakes special
developmental Squirrel Cage
challenges of varied
customer requirements.
AC Induction Motors
Rating up to 315 kW (425 HP)
Today LHP is an acclaimed Pole : 2/4/6/8
Mounting : B3 / B5 / B6 / B7 / B8
'First Choice' of leading : B14 /B 35 /
companies in India. B 34 / V1 / V3 / V5 / V6 / V15 / V18 / V19 / V36

With this background, You are about to select


we are making news India's one of the most
into international reliable Induction Motors
markets and receiving which assures you
wider acceptance trouble-free
from companies performance.
across the world.
Selecting a LHP motor
LHP's right attitude of will keep your equipments
the highest quality in all running round the clock,
aspects is the assurance year after year, ensuring
of its becoming customer satisfaction.
a successful global brand.
This selection guide will
help you to find the
right motor for your
application. In case you
don't find one, do get in touch
with us.
Sharadkrishna Thakre
Managing Director We would be glad to Q Wide range

develop a Special Purpose


Motor specifically for you. Q Highly reliable
Contents

Range of Products : 1

Applicable Standards : 2

Standard Motors : Output Summary : 3

Mechanical Features : 4-5

Dimensions of Foot Maunted Motors (B-3 Mounting) as per IS : 1231 : 6

Dimensions of Face Mounted Motors (B-14 Mounting) as per IS: 2223 : 7

Dimensions of Flange Mounted Motors (B-5 Mounting) as per IS: 2223 : 8

Permissible radial load for Standard Motors : 9

Electrical Features : 10

Guidelines for Motors Protection fuse rating : 11

Electrical Performance Figures : 12-15

Brake Motors : 16-17

Crane Duty Motor : 18-19

20-22
Electrical performance Figures of standard TEFC Foot, flange & Face Mounted & :
Single phase motors.

Energy Efficient Motors (IE-2) : 23-25

Cooling Tower Motors : 26

Flame-proof Motors (Ex 'd' ) : 27-35

Roller Table Motors : 36

Non-Sparking Motors (Ex 'nA') : 37-38

Tolerance on Performance Values & Dimensions : 39-40

Shipping Specifications : 41

Information required along with Purchase Order / Enquiry : 42


2.0 Range of Products

Table No. -1

Sr. No. Motor Frame Size Type

01 Standard motors 63 to 90 (2 Pole)


A. Single Phase 63 to 100L (2 Pole) CSR

80 to 100L (4 Pole) CSIR

71 to 100L (4 Pole) CSCR

B. Three Phase 63 to 355L

02 Brake motors 63 to 200L

03 Crane & Hoist Duty Motors 63 to 160L

04 Flame-Proof Motors (Gas group I, II A, II B) 63 to 315L


Flame-Proof motors (Gas group IIC) 63 to 315 L
Flame-Proof Brake Motors 71 to 180 L
Flame-Proof Motors with CE ATEX 63 to 80

05 Non-Sparking motors 63 to 355L

06 Energy Efficient motor (IE-2) 71 to 355L

07 Roller Table motors 112 to 355L

08 Special Motors B. Mechanical


A. Electrical 01 Non-standard mounting dimensions
01 Dual speed motor 02 Special shaft extension
02 Dual voltage motor 03 Double extension
(1:2 OR 1:1.7321ratio) 04 Low vibration and noise motors
03 15 to 60 Hz. frequency motor 05 Non-standard paint shade
04 Other than standard 415V & 50 Hz 06 Special shaft material
frequency rated motor
07 Motors for cooling towers
05 High torque motor
08 Geared motor
06 H class motor
07 High slip motors
08 Special Performance Requirements.
09 Inverter duty motors
10 Cooling tower motors

1
3.0 Applicable Standards

The motors manufactured conform to the following National standards and equivalent International standards.

National
Title IEC
Standards

IS : 325 Three phase induction motors IEC 60034-1

IS : 4722 Rotating electrical machines ---------

IS : 12824 Types of duty & classes of rating assigned to rotating electrical machines ---------

IS : 4889 Methods of determination of efficiency of rotating electrical machines IEC 60034-2

IS : 4691 Degree of protection provided by enclosure for rotating electrical machinery IEC 60034-5

IS : 6362 Designation of methods of cooling of rotating electrical machines IEC 60034-6

IS : 2253 Designation for types of construction & mounting arrangements of IEC 60034-7
rotating electrical machines.

IS : 4728 Terminal marking & direction of rotation for rotating electrical machinery IEC 60034-8

IS : 12065 Permissible limits of noise levels for rotating electrical machines IEC 60034-9

IS : 12075 Mechanical vibration of rotating electrical machines with shaft height 56 mm IEC 60034-14
& higher measurement, evaluation & limits of vibration severity.

IS : 1231 Dimensions of three phase foot mounted induction motors IEC 60072-1

IS : 2223 Dimensions of flange mounted induction motors IEC 60072-1

IS : 8223 Dimensions and output series for rotating electrical machines IEC 60072-2

IS : 1271 Thermal evaluation and classification of electrical insulation IEC 60034-11

IS : 2148/IS/IEC-60029-1 Electrical Apparatus for Explosive Gas Atmospheres-Flame-proof enclosures 'd' IEC 60079-1

IS/IEC : 60079-15 Three phase Induction motors with type of protection (Ex 'nA') IEC 60079-15

IS : 12615 Specification for Energy Efficient Induction Motors IEC 60034-30

2
4.0 Standard Motors : Output Summary

Table No. - 2A
Frame output summary for LHP Three Phase Induction Motor

Pole-wise Frame Size


Output Standard, Brake & Non-sparking Crane Duty
Flame Proof Motor
(kw / HP) Induction Motor Motor
2 Pole 4 Pole 6 Pole 8 Pole 4 Pole 6 Pole 2 Pole 4 Pole 6 Pole 8 Pole
0.12/0.16 63 63 71 -- -- -- 63 63 71 --
0.18/0.25 63 63 71 80 -- -- 63 63 71 80
0.25/0.33 63 71 71 80 -- -- 63 71 71 80
0.37/0.50 71 71 80 90S 71 71 71 71 80 90S
0.55/0.75 71 80 80 90L 71 80 71 80 80 90L
0.75/1.00 80 80 90S 100L 80 80 80 80 90S 100L
1.10/1.50 80 90S 90L 100L 80 90S 90S 90S 90L 100L
1.50/2.00 90S 90L 100L 112M 90S 90L 90S 90L 100L 112M
2.20/3.00 90L 100L 112M 132S(112M) 90L 100L 90L 100L 112M 132S
3.70/5.00 100L 112M 132S 160M (132M) 100L 112M 100L 112M 132S 160M
5.50/7.50 132S (112M) 132S 132M 160M 112M 132S 132S 132S 132M 160M
7.50/10.00 132S 132M 160M 160L 132M 132M 132S 132M 160M 160L
9.30/12.50 (132M) (160M) (160L) 180L (132M) (160M) (132M) (160M) (160L) 180L
11.00/15.00 160M 160M 160L 180L 160M 160M 160M 160M 160L 180L
15.00/20.00 160M 160L 180L 200L 160M 160L 160M 160L 180L 200L
18.50/25.00 160L 180M 200L 225S 160L -- 160L 180M 200L 225S
22.00/30.00 180M 180L 200L 225M -- -- 180M 180L 200L 225M
30.00/40.00 200L 200L 225M 250M -- -- 200L 200L 225M 250M
37.00/50.00 200L 225S 250M 280S -- -- 200L 225S 250M 280S
45.00/60.00 225M 225M 280S 280M -- -- 225M 225M 280S 280M
55.00/75.00 250M 250M 280M 315S -- -- 250M 250M 280M 315S
75.00/100.00 280S 280S 315S 315S -- -- 280M 280S 315S 315S
90.00/120.00 280M 280M 315M 315L -- -- 280M 280M 315M 315M
110.00/150.00 315S 315S 315L 315L -- -- 315S 315S 315M 315M
125.00/170.00 315M 315M 315L 355L -- -- 315M 315M -- --
132.00/180.00 (315M) (315M) (355L) (355L) -- -- (315M) (315M) (315L) (315L)
160.00/215.00 (315L) (315L) (355L) (355L) -- -- (315L) (315L) (315L) (315L)
180.00/250.00 (315L) (315L) (355L) (355L) -- -- (315L) (315L) -- --
200.00/270.00 (315L) (315L) (355L) (355L) -- -- (315L) (315L) -- --
225.00/300.00 (355L) (355L) (355L) -- -- -- -- --
250.00/335.00 (355L) (355L) (355L) -- -- -- -- --
315.00/425.00 (355L) (355L) -- -- -- -- -- --
Note : Frame-wise ratings are as per IS standards except those ratings in bracket. These are as per LHP standard.
Table No. - 2B
Frame output summary for LHP Single Phase Induction Motor

For Metric Frame Motors


4-Pole Frame 2-Pole Frame 4-Pole Frame
Sr.No. kW/HP CSCR CSIR CSR CSR

1 0.18/0.25 71 80L 63 71
2 0.37/0.5 80L 80L 71 80L
3 0.55/0.75 80L 90L 71 80L
4 0.75/1.0 80L 90L 80L 80L
5 1.1/1.5 90L 90L 90L 90L
6 1.5/2 100L 100L 90L 100L
3
5.0 Mechanical Features

Sr. No. Features Standard Optional


1 Frames Motor frames from 63 to 112 frame are made of Aluminum Motors frames offered in Al.
pressure die cast bodies & 132S to 355L frames are made of pressure die cast can be offered
cast iron or M.S. fabricated. in cast iron also.
2 End Covers 63 to 90L frames are made of Aluminum pressure die cast. 63 to 90L frames can be offered in
All covers are with integral bearing housing bores. cast iron also.
3 Flanges- 63 to 90L frames flanges are in Aluminum PDC/GDC. All Special flanges can be offered.
D Type/C Type flanges are with integral bearing housing bores. 100 to 355L 63 to 90L frames flanges can be
frames flanges are in CI only. offered in CI
4 Terminal Box Construction : Terminal box with special material &
63 to 112 frame - Aluminum PDC/GDC special design can be offered on
132 to 180 frame - Pressed sheet metal / Cast Iron request.
200 to 355 frame- Pressed sheet metal / Cast Iron
5 Cable Entry All T. Boxes can be rotated in a step of 90° through 360° for
Position desired direction of cable entry. ---

6 T.Box Position Please see dimensional table for T.Box position. ---
7 Cable Gland Cable Gland holes are B.S. conduit threading. Cable glands of other conduit
For sizes & no. of entries please refer to dimensional table. threading like PG type/Metric
type can be offered.
8 Shaft Motor shafts are made of Carbon Steel 40C8/45C8 as per Shaft with other material like
IS:2073 OR as per BS 970 En 8/EN8D. All shafts have AISI-400, AISI-300, En 24 with heat
threaded center hole as per DIN-332 standard. treatment can be offered. Speical
Key & keyways on shaft are made as per IS:2048 keys & keyways can be offered.
9 Bearings 63 to 225M frame motors have double shielded deep Angular Contact ball bearings,
groove ball bearing (single row). Prelubricated for life taper roller bearings, spherical roller
250 to 355L frames motors have open type deep groove ball bearings, cyl. roller bearings, Insulated
Bearing on both end (See Table No. A) bearings can be offered. In 63 to 160
frame open bearing can be given.
10 Lubrication 63 to 112 frame motors are with medium temp. Pregreased Motors with greasing arrangement
132 to 225 frame motors are with high temperature pre-greased in 63 to 225 frame can be offered.
bearings. Online greasing arrangement is provided for motors
in 250 to 355L frames. with H. T. grease.
11 V Ring Seals 63 to 225 frame are with V ring seals. Motors with oil seals can be offered.
12 Oil Seals 250 to 355L frame are with Oil Seal and felt. 63 to 160 frame motor with oil seal can be given
13 Mounting 63 to 225 frames motors are suitable for both vertical and For vertical mounting motors in
Arrangement horizontal mounting arrangement 250 to 355L frame contact LHPL.
Foot mounting motors : B3, B6, B7, B8, V5 & V6
Flange (D Type Flange) Mounting motors : B5, VI, V3, B35,
V15 & V36
Flange (C Type Flange) Mounting motors : B14, V18, V19,
B34, V58 & V69
250 to 355L frame std. motors are suitable for horizontal
mounting only (B3,B6,B37,B8,B5 & B35)
14 Degree of IP : 55 IP :44, IP : 54, IP : 56, IP57, IP:65,
Protection IP:66, IP67, IP68 can be given
15 Noise Level Noise level of motors conform to IS:12065 specifications. Motors with low noise level can
(See Table No. B) be offered.
16 Vibration Vibration levels are maintained as per normal class of Precision class of vibration can
Level/Severity IS : 12075. (See Table No. C) be offered.
17 Paint (a) Flame-proof , Non-sparking & Anti Corrosive Epoxy Paint
Cooling Tower motors of RAL 7015 Slate Grey Shade.
Anti Corrosive Epoxy Paint Other types of Colors & Shades also
(b) Cooling Tower motors Blue M & P can be given as per standards.
(c) All other motors Anti Corrosive Polyurethine Paint
of RAL 7015 Slate Grey Shade.
4
Table No. - A Table No. - B
Frame wise bearing sizes Limiting Mean Sound Power Level Lw in dB (A)
for airborne noise emitted by rotating electrical machines

Frame Size Bearing No. Protection IP IP IP IP IP IP


DE NDE Enclosure 55 55 55 55 55 55

63 6201 ZZ 6201 ZZ Ratings in kV Rated Speed (rev./min.)

71 6203 ZZ 6203 ZZ 960 & below 961-1320 1321-1900 1901-2360 2361-3150 3150-3750

80 6204 ZZ 6204 ZZ Above Up to

90 S/L 6205 ZZ 6304/6205 ZZ -- 1.1 76 79 80 83 84 88

100 L 6206 ZZ 6206 ZZ 1.1 2.2 79 80 83 87 89 91

112 M 6306 ZZ 6206 ZZ 2.2 5.5 82 84 87 92 93 95

132 S/M 6308 ZZ C3 6208 ZZ C3 5.5 11 85 88 91 96 97 100


160 M/L 6309 ZZ C3 6209 ZZ C3 11 22 89 93 96 98 101 103
180 M 6310 ZZ C3 6210 ZZ C3 22 37 91 95 97 100 103 105
200 L 6312 ZZ C3 6312 ZZ C3 37 55 92 97 99 103 105 107
225 S/M 6313 ZZ C3 6313 ZZ C3 55 110 96 101 104 105 107 109
250 M 6314 C3 6214 C3 110 220 100 104 106 108 110 112
280 S/M 6318 C3 6316 C3 220 630 102 106 109 111 112 114
315 S/M/L 6319 C3 6219 C3
355 S/M/L 6322 C3 6322 C3

Table No. - C
Vibration Levels
Shaft center HT,
63 to 132 160 to 225 Above 225
H in mm
Range of speed 600 to 1500 Above 1500 & 600 to 1500 Above 1500 & 600 to 1500 Above 1500 &
up to 3000 up to 3000 up to 3000
class of
RMS value of vibration velocity, mm/s
vibration severity
Normal 1.8 1.8 1.8 1.8 2.8 4.5
Precision A 0.71 0.71 0.71 1.12 -- --
Precision B 0.45 0.45 0.45 0.71 -- --
Precision C 0.28 0.28 0.28 0.45 -- --
Vibration Severity
Shaft center Ht,
63 to 132 160 to 225 Above 225
H in mm
Pole 8 6 4 2 8 6 4 2 8 6 4 2
Speed, rpm 750 1000 1500 3000 750 1000 1500 3000 750 1000 1500 3000
Class of vibration
RMS value of vibration displacement, Microns
serverity
Normal 64 48 32 16 64 48 32 25 100 75 50 42
Precision A 24 18 12 6 24 18 2 10 -- -- -- --
Precision B 16 12 8 4 16 12 8 6 -- -- -- --
Precision C 10 8 5 2.5 10 8 5 4 -- -- -- --

5
6.0 Dimensions of Foot Maunted Motors (B-3 Mounting) as per IS : 1231
(Standard, Brake, Non-sparking & Crane, Hoist duty motors)

Table No. - 03
Frame CONT. H C A AB HA OK B BB AD OAC OD E F G GA TH L CG X For Brake For 10
Motor Motor T.Box
Size MAX MAX Nos. Position
AD L AD L
63 CI 63 40 100 120 8 7 80 97 121 116 11j6 23 4 8.5 12.5 M5 218 3/4"-1 -- -- -- -- RHS
63 AL PDC 63 40 100 118 8 7 80 97 105 116 11j6 23 4 8.5 12.5 M5 218 3/4"-1 106 276 -- -- TOP
71 CI 71 45 112 132 9 7 90 112 117 140 14j6 30 5 11.0 16.0 M5 254 3/4"-1 129 329 -- -- RHS
71 AL PDC 71 45 112 133 9 7 90 110 117 140 14j6 30 5 11.0 16.0 M5 254 3/4"-1 129 329 119 302 TOP
80 CI 80 50 125 151 10 10 100 124 122 158 19j6 40 6 15.5 21.5 M6 285 3/4"-1 135 380 -- -- RHS
80 AL PDC 80 50 125 153 12 10 100 124 110 158 19j6 40 6 15.5 21.5 M6 285 3/4"-1 151 380 114 347 TOP
90S CI 90 56 140 170 10 10 100 120 158 178 24j6 50 8 20.0 27.0 M8 321 3/4"-1 145 432 -- -- RHS
90S AL PDC 90 56 140 170 14 10 100 125 160 178 24j6 50 8 20.0 27.0 M8 341 3/4"-1 -- -- -- -- RHS
90L CI 90 56 140 170 10 10 125 145 158 178 24j6 50 8 20.0 27.0 M8 370 3/4"-1 145 452 159 386 RHS
90L AL PDC 90 56 140 170 13 10 125 146 137 178 24j6 50 8 20.0 27.0 M8 356 3/4"-1 165 427 -- -- TOP
100L CI 100 63 160 200 13 12 140 170 170 208 28j6 60 8 24.0 31.0 M10 389 3/4"-1 162 495 152 429 RHS
100L AL PDC 100 63 160 195 15 12 140 172 174 208 28j6 60 8 24.0 31.0 M10 396 3/4"-1 162 495 -- -- RHS
112M CI 112 70 190 230 15 12 140 170 185 224 28j6 60 8 24.0 31.0 M10 405 3/4"-1 175 511 -- -- RHS
112M AL PDC 112 70 190 172 12 12 140 202 179 214 28j6 60 8 24.0 31.0 M10 448 3/4"-1 179 580 -- -- RHS
132S CI 132 89 216 256 16 12 140 167 203 257 38k6 80 10 33.0 41.0 M12 463 3/4"-2 202 595 -- -- RHS
132M CI 132 89 216 256 16 12 178 205 203 257 38k6 80 10 33.0 41.0 M12 500 3/4"-2 202 629 -- -- RHS
132M(N) CI 132 89 216 256 16 12 178 245 203 257 38k6 80 10 33.0 41.0 M12 525 3/4"-2 202 655 -- -- RHS
160M CI 160 108 254 304 26 15 210 260 233 312 42k6 110 12 37.0 45.0 M16 623 1"-2 233 760 -- -- RHS
160L CI 160 108 254 304 26 15 254 304 233 312 42k6 110 12 37.0 45.0 M16 667 1"-2 233 803 -- -- RHS
180M CI 180 121 279 340 26 15 241 318 256 357 48k6 110 14 42.5 51.5 M16 721 1"-2 256 842 -- -- RHS
180L CI 180 121 279 340 26 15 279 318 256 357 48k6 110 14 42.5 51.5 M16 721 1"-2 256 842 -- -- RHS
200L CI 200 133 318 385 35 19 305 350 313 380 55m6 110 16 49.0 59.0 M20 800 2"-2 313 963 -- -- TOP
225S(2P) CI 225 149 356 348 35 19 286 370 370 446 55m6 110 16 49.0 59.0 M20 860 2"-2 -- -- -- -- TOP
225S(4,6,8 P) CI 225 149 356 348 35 19 286 370 370 446 60m6 140 18 53.0 64.0 M20 820 2"-2 -- -- -- -- TOP
225M(2P) CI 225 149 356 440 35 19 311 370 370 446 55m6 110 16 49.0 59.0 M20 900 2"-2 -- -- -- -- TOP
225M(4,6,8 P) CI 225 149 356 440 35 19 311 370 370 446 60m6 140 18 53.0 64.0 M20 860 2"-2 -- -- -- -- TOP
250M (2P) CI 250 168 406 500 43 24 349 425 412 485 60m6 140 18 53.0 64.0 M20 990 2"-2 -- -- -- -- TOP
250M (4,6,8 P) CI 250 168 406 500 43 24 349 425 412 485 65m6 140 18 58.0 69.0 M20 938 2"-2 -- -- -- -- TOP
280S (2P) CI 280 190 457 540 43 24 368 490 442 540 65m6 140 18 58.0 69.0 M20 1075 2"-2 -- -- -- -- TOP
280S(4,6,8 P) CI 280 190 457 540 43 24 368 490 442 540 75m6 140 20 67.5 79.5 M20 1033 2"-2 -- -- -- -- TOP
280M (2 P) CI 280 190 457 540 43 24 419 490 442 540 65m6 140 18 58.0 69.0 M20 1075 2"-2 -- -- -- -- TOP
280M (4,6,8 P) CI 280 190 457 540 43 24 419 490 442 540 75m6 140 20 67.5 79.5 M20 1037 2"-2 -- -- -- -- TOP
315S (2 P) CI 315 216 508 620 50 28 406 600 524 625 65m6 140 18 58.0 69.0 M20 1090 2"-2 -- -- -- -- TOP
315S (4,6,8 P) CI 315 216 508 620 50 28 406 600 524 625 80m6 170 22 71.0 85.0 M20 1065 2"-2 -- -- -- -- TOP
315M (2 P) CI 315 216 508 620 50 28 457 600 524 625 65m6 140 18 58.0 69.0 M20 1243 2"-2 -- -- -- -- TOP
315M (4,6,8 P) CI 315 216 508 620 50 28 457 600 524 625 80m6 170 22 71.0 85.0 M20 1218 2"-2 -- -- -- -- TOP
315L (2 P) CI 315 216 508 620 50 28 508 600 524 625 65m6 140 18 58.0 69.0 M20 1243 2"-2 -- -- -- -- TOP
315L (4,6,8 P) CI 315 216 508 620 50 28 508 600 524 625 80m6 170 22 71.0 85.0 M20 1218 2"-2 -- -- -- -- TOP
355S (2 P) CI 355 254 610 730 51 28 500 780 626 745 80m6 170 22 71.0 85.0 M20 1524 21/2"-2 -- -- -- -- TOP
355S (4,6,8 P) CI 355 254 610 730 51 28 500 780 626 745 100m6 210 28 90.0 106.0 M24 1491 21/2"-2 -- -- -- -- TOP
355M (2P) CI 355 254 610 730 51 28 560 780 626 745 80m6 170 22 71.0 85.0 M20 1524 21/2"-2 -- -- -- -- TOP
355M (4,6,8 P) CI 355 254 610 730 51 28 560 780 626 745 100m6 210 28 90.0 106.0 M24 1491 21/2"-2 -- -- -- -- TOP
355L (2 P) CI 355 254 610 730 51 28 630 780 626 745 80m6 170 22 71.0 85.0 M20 1524 21/2"-2 -- -- -- -- TOP
355L (4,6,8 P) CI 355 254 610 730 51 28 630 780 626 745 100m6 210 28 90.0 106.0 M24 1491 21/2"-2 -- -- -- -- TOP
6
7.0 Dimensions of Face Mounted Motors (B-14 Mounting) as per IS: 2223

(Standard, Brake, Non-sparking & Crane, Hoist duty motors)


AD
TD

OM GA

OD
ON G

OAC
OP TH
G
CG
T
E
L

CE - Cable entry in BSC

Table No. - 04
Frame Cont. Flange OM ON OP S TD T AD OAC OD E F G GA TH L CE X For Brake For 10
Size No. 0.3 j6 MAX MAX Nos. Motor Motor

AD L AD L

63 CI F75C 75 60 90 M5 6 2.5 120 116 11j6 23 4 8.5 12.5 M5 218 3/4"-1 121 276 -- --

63 AL.PDC F75C 75 60 90 M5 6 2.5 105 116 11j6 23 4 8.5 12.5 M5 218 3/4"-1 117 276 -- --

71 CI F85C 85 70 105 M6 8 2.5 115 140 14j6 30 5 11 16 M5 254 3/4"-1 129 325 -- --

71 AL.PDC F85C 85 70 107 M6 8 2.5 115 140 14j6 30 5 11 16 M5 254 3/4"-1 125 325 119 302

80 CI F100C 100 80 120 M6 8 3 125 158 19j6 40 6 15.5 21.5 M6 285 3/4"-1 127 380 -- --

80 AL.PDC F100C 100 80 120 M6 8 3 110 158 19j6 40 6 15.5 21.5 M6 285 3/4"-1 146 380 -- --

90S CI F115C 115 95 140 M8 10 3 160 178 24j6 50 8 20 27 M8 320 3/4"-1 152 435 -- --

90S AL.PDC F115C 115 95 140 M8 10 3 160 178 24j6 50 8 20 27 M8 340 3/4"-1 160 426 -- --

90L CI F115C 115 95 140 M8 10 3 160 178 24j6 50 8 20 27 M8 345 3/4"-1 152 454 152 395

90L AL.PDC F115C 115 95 140 M8 10 3 160 178 24j6 50 8 20 27 M8 355 3/4"-1 164 424 -- --

100L CI F130C 130 110 160 M8 10 3.5 158 208 28j6 60 8 24 31 M10 405 3/4"-1 158 510 152 435

100L AL.PDC F130C 130 110 160 M8 10 3.5 175 208 28j6 60 8 24 31 M10 395 3/4"-1 162 495 -- --

112M CI F130C 130 110 160 M8 10 3.5 185 225 28j6 60 8 24 31 M10 405 3/4"-1 171 510 -- --

112M AL.PDC F130C 130 110 160 M8 10 3.5 180 215 28j6 60 8 24 31 M10 430 3/4"-1 179 562 -- --

132S CI F165C 165 130 196 M12 14 3.5 210 260 38k6 80 10 33 41 M12 460 3/4"-2 202 586 -- --

132M CI F165C 165 130 196 M12 14 3.5 210 260 38k6 80 10 33 41 M12 500 3/4"-2 202 629 -- --

132M(N) CI F165C 165 130 196 M12 14 3.5 210 260 38k6 80 10 33 41 M12 525 3/4"-2 202 655 -- --

7
8.0 Dimensions of Flange Mounted Motors
(B-5 Mounting) as per IS : 2223

AD T
LD

GA
ON
F

OD
OP

OAC
OM

G OS

LA
E
L
CE - Cable entry size in BSC

Table No. - 05

AD OAC OD CE For For Single


Frame Cont. Flange OM j6 OP OS X NO. T LA LD E F G GA TH L Brake Phase
Size No. MAX MAX X Motor Motor
0.3 ON Nos.
AD L AD L

63 CI F115B 115 95 140 10 X 4 3 10 10 120 116 11j6 23 4 8.5 12.5 M5 218 3/4"-1 121 276 --- ---

63 AL.PDC F115B 115 95 140 10 X 4 3 10 10 105 116 11j6 23 4 8.5 12.5 M5 218 3/4"-1 117 276 --- ---

71 CI F130B 130 110 160 10 X 4 3.5 10 10 115 140 14j6 30 5 11 16 M5 254 3/4"-1 129 325 --- ---

71 AL.PDC F130B 130 110 160 10 X 4 3.5 10 20 115 140 14j6 30 5 11 16 M5 254 3/4"-1 125 325 119 302

80 CI F165B 165 130 200 12 X 4 3.5 11 16 125 158 19j6 40 6 15.5 21.5 M6 285 3/4"-1 127 380 ---- ---

80 AL.PDC F165B 165 130 200 12 X 4 3.5 11 16 110 158 19j6 40 6 15.5 21.5 M6 285 3/4"-1 146 380 114 348

90S CI F165B 165 130 200 12 X 4 3.5 11 22 160 178 24j6 50 8 20 27 M8 320 3/4"-1 152 435 --- ---

90S AL.PDC F165B 165 130 200 12 X 4 3.5 11 22 160 178 24j6 50 8 20 27 M8 340 3/4"-1 160 426 --- ---

90L CI F165B 165 130 200 12 X 4 3.5 11 22 160 178 24j6 50 8 20 27 M8 370 3/4"-1 152 456 152 395

90L AL.PDC F165B 165 130 200 12 X 4 3.5 11 22 160 178 24j6 50 8 20 27 M8 355 3/4"-1 164 424 --- ---

100L CI F215B 215 180 250 15 X 4 4 12 20 158 208 28j6 60 8 24 31 M10 405 3/4"-1 158 497 152 435

100L AL.PDC F215B 215 180 250 15 X 4 4 12 22 175 208 28j6 60 8 24 31 M10 395 3/4"-1 162 497 --- ---

112M CI F215B 215 180 250 15 X 4 4 12 23 185 225 28j6 60 8 24 31 M10 405 3/4"-1 189 510 --- ---

112M AL.PDC F215B 215 180 250 15 X 4 4 12 18 180 215 28j6 60 8 24 31 M10 430 3/4"-1 179 553 --- ---

132S CI F265B 265 230 300 15 X 4 4 13 47 210 260 38k6 80 10 33 41 M12 460 3/4"-2 202 595 --- ---

132M CI F265B 265 230 300 15 X 4 4 13 47 210 260 38k6 80 10 33 41 M12 500 3/4"-2 202 629 --- ---

132M (N) CI F265B 265 230 300 15 X 4 4 13 47 210 260 38k6 80 10 33 41 M12 525 3/4"-2 202 655 --- ---

160M CI F300B 300 250 350 19 X 4 5 14 54 230 312 42k6 110 12 37 45 M16 620 1"-2 233 760 --- ---

160L CI F300B 300 250 350 19 X 4 5 14 54 230 312 42k6 110 12 37 45 M16 660 1"-2 233 803 --- ---

180M/L CI F300B 300 250 350 19 X 4 5 14 72 255 360 48k6 110 14 42.5 51.5 M16 720 1"-2 835 725 --- ---

200L CI F350B 350 300 400 19 X 8 5 16 71 340 382 55m6 110 16 49 59 M20 780 2"-2 -- -- --- ---

225S/M (2P) CI F400B 400 350 450 19 X 8 5 16 71 375 445 55m6 110 16 49 59 M20 860 2"-2 -- -- --- ---

225S/M (4,6,8P) CI F400B 400 350 450 19 X 8 5 16 71 375 445 60m6 140 18 53 64 M20 820 2"-2 -- -- --- ---

250M (2P) CI F500B 500 450 550 19 X 8 5 19 65 410 485 60m6 140 18 53 64 M20 988 2"-2 -- -- --- ---

250M (4,6,8P) CI F500B 500 450 550 19 X 8 5 19 65 410 485 65m6 140 18 58 69 M20 938 2"-2 -- -- --- ---

280S/M (2P) CI F500B 500 450 550 19 X 8 5 22 50 430 540 65m6 140 18 58 69 M20 1075 2"-2 -- -- --- ---

280S/M (4,6,8P) CI F500B 500 450 550 19 X 8 5 22 50 430 540 75m6 140 20 67.5 79.5 M20 1045 2"-2 -- -- --- ---

315S/M/L (2P) CI F600B 600 550 660 24 X 8 6 22 50 520 625 65m6 140 18 58 69 M20 1240 2"-2 -- -- --- ---

315S/M/L (4,6,8P) CI F600B 600 550 660 24 X 8 6 22 50 520 625 80m6 170 22 71 85 M20 1245 2"-2 -- -- --- ---

355S/M/L (2P) CI F740B 740 680 800 24 X 8 6 25 45 625 745 80m6 170 22 71 85 M20 1570 1/2

2 -2 -- -- --- ---

355S/M/L (4,6,8P) CI F740B 740 680 800 24 X 8 6 25 45 625 745 100m6 210 28 90 106 M24 1600 1/2

2 -2 -- -- --- ---

8
9.0 Permissible radial load for Standard Motors

The radial load for a given motor depends on the type and size of pulley/pinion chosen and type of driven machine. Radial load
can be calculated using the following formula.

a x 973 x kW
p= +W Where, a = Belt Factor 2 to V belts
RPM x D/2
3for flat belts
kW = Output of the motor in kW.
RPM = Speed of the motor in Rev./Min.
D = Dia. of pulley in meters.
W = Weight of the pulley in kg.

It is recommended that the mounting of pulley/pinion be such that the load acts at the middle of extension of the shaft. For radial
loads other than those recommended in Table No. 06, customers are advised to consult LHP for maximum allowable loads.

Table No. - 06
Permissible Radial and Axial load on Motor
(At the center of extension (Std.) including weight of the pulley)

Synchronous RPM & Radial Load in Kg. Permissible Axial Recommended Pulley Size
Frame Size Load in Kg. Dia.x Width (D x W) in mm.
3000 1500 1000 750
63 30 30 30 30 10 52 x 30
71 35 35 35 35 12 60 x 40
80 50 60 60 60 20 100 x 50
90 55 55 65 75 25 125 x 60
100 70 80 80 100 35 150 x 80
112 95 110 110 110 40 200 x 100
132 150 175 200 210 50 225 x 125
160 260 300 325 350 70 275 x 140
180 325 350 400 400 80 315 x 160
200 425 500 575 575 100 355 x 200
225 450 600 650 650 100 400 x 200
250 600 800 900 900 110 400 x 200
280 650 1600 1800 1800 120 450 x 250
315 700 1800 1900 2000 130 500 x 280
355 600 2000 1500 600 150 550 x 300

9
10.0 Electrical Features

Sr. No. Features Standard Optional

1. Supply voltage and frequency 415 +


_ 10% and 50 Hz +
_ 5% with combined Voltage up to 660V AC and frequency
variations of +
_ 10% from 5Hz to 120 Hz

2. Winding and insulation class Core material is of low loss magnetic High grade steel and insulation class
silicon steel. H can be given on request. And Epoxy
Winding wound with polyester enameled Gel coat provided on winding.
copper wire and with F class insulating
material and vacuum impregnated with
class 155 (F) impregnating resins.

3. Rotor Aluminum die cast rotor dynamically Copper brazed Rotors


balanced with half key to have low vibration. can be given on request.
4. Starts 5 to 7 seconds for two consequent starts Other requirement can be given on
2
from cold condition. request. Customer shall specify GD
of load speed, period of acceleration,
speed torque curve of equipment and
method of breaking.

5. Duty Continuous (S1) Other duties S2 to S8 can be given on


request

6. Starting method Up to 100 Frame - DOL Starting (3 Pin T. Block) Up to 100 Frame - Start delta
Above 100 Frame - Star Delta starting (6 pin T. Block)
(6 pin T. Block)
* However, motors above 100 Frame can be
used for DOL starting by making suitable
connection.

7. Direction of rotation Bi-directional. ----

8. Earthing Provided on frame and inside the terminal box Can be given as per requirement.

9. Overload Withstood 160% of rated torque for 15 seconds. Other requirement can be given on
request.
10. Service factor 1.0 Other service factor can be given on
request
11. Accessories ---- BTD, Thermistor/space heater,
Thermotrip /Winding RTD'S can be
given on request

10.1 Permissible temperature rise : 10.2 Derating factors :


Standard LHP motors are manufactured with class F The rating of motor is reduced when ambient temperature
0
insulation and temperature rise restricted to class B exceeds 40 C and/or the altitude of the site is more than
insulation. 1000 meters above sea level.
Max. Permissible Temp. rise for Ambient % output Altitude above % output
0
Class of Max.permissible windings at Amb. Temp. in C temp. rise of motor sea level meters of motor
0
Insualtion Temp. Limit C
40 45 50 60 40 100 Up to 1000 100
B 130 80 75 70 60 45 98 Up to 2000 95
F 155 105 100 95 85 50 96 Up to 3000 85
H 180 125 120 115 105 60 90 Up to 4000 77

10
10.3 Guidelines for Motors Protection fuse rating

The motors are to be provided with back up fuse protection of suitable ratings in addition to starters (D.O.L. or Star/Delta)
being used to protect motors from overload and under voltage. The given below gives general guidelines for selection of
fuse ratings.

Table No. - 07 Fuse Rating


D.O.L. Starting

O/P Rating KW 0.37 0.55 0.75 1.1 1.5 2.2 3.7 5.5 7.5 9.3 11 15 18.5 22 30 37 45 55 75 90
HP 0.5 0.75 1 1.5 2 3 5 7.5 10 12.5 15 20 25 30 40 50 60 75 100 125
Average Value 1 1.3 1.9 2.6 3.7 4.8 7.8 11.2 15 18 21 27 33 39 53 65 78 96 131 156
in AMPS

Fuse Rating 4 6 6 6 10 16 16 25 25 32/35 32/35 50 63 63 100 100 160 160 200 250

Bi-Metal 0.5-1 1-2 1-2 1.5-3 2-4 3-6 6-12 6-12 10-16 18-24 18-24 16-32 24-45 24-45 32-63 50-90 50-90 70-110 90-135 140-170
Relay Range

Star-Delta Starting

O/P Rating KW 2.2 3.7 5.5 7.5 9.3 11 15 18.5 22 30 37 45 55 75 90 110 132
HP 3 5 7.5 10 12.5 15 20 25 30 40 50 60 75 100 125 150 180
Full Load Current
Line 4.8 7.8 11.2 15 18 21 27 33 39 53 65 78 96 131 156 185 220
Phase 2.8 4.5 6.5 9 11 12.7 16.8 20.2 23.2 30.6 37.5 46.4 54.5 74 88 107 127

Overload Relay 1.5-3 3-6 4-8 6-12 6-12 10-16 18-24 18.24 12.24 16-32 24-45 32-63 32.63 50-90 80-100 70-110 90-135
Range Fuse Rating 10 16 16 25 25 25 50 50 63 63 80 100 125 160 200 200 250
1. The abov eare recommended values for H.R.C. delayed action fuse for direct on line starting

11
Electrical Performance Figures

Table No. - 08
Electrical performance figures of Standard and Brake TEFC Foot, Flange & Face Mounted Three Phase
At 415 V +
_ 10%, 50 Hz +
_ 5% Two Pole Induction Motor

Rated Output Frame Rated Rated Rated Starting Starting Peak Efficiency % Power Factor Rotor Approx.
Size Current Speed Torque Current Torque Torque 2 Net
kW HP 100% 75% 50% 100% 75% 50% GD
Amps RPM kgm % of % of % of kg m sq Weight
Rated Rated Rated kg
Current Torque Torque AL/CI

0.18 0.25 63 0.60 2730 0.06 400 240 310 64 62 56 0.68 0.65 0.54 0.0009 6/10

0.25 0.33 71 0.70 2820 0.09 430 220 320 70 68 62 0.71 0.65 0.55 0.0015 8/14

0.37 0.5 71 1.10 2800 0.13 490 250 320 66.1 64.1 58.1 0.71 0.65 0.59 0.0015 8/14

0.55 0.75 71 1.45 2800 0.19 520 230 300 69.1 64.4 60.1 0.76 0.72 0.67 0.0021 8/14

0.75 1 80 1.70 2800 0.26 600 240 320 72.1 70.1 65.1 0.85 0.79 0.73 0.0036 12/18

1.1 1.5 80 2.55 2860 0.38 590 240 320 75 72 69 0.80 0.74 0.72 0.0036 12/18

1.5 2 90S 3.30 2860 0.51 580 240 300 77.2 76.2 73.2 0.81 0.78 0.72 0.0073 18/25

2.2 3 90L 4.60 2860 0.75 650 240 300 79.7 77.2 75.7 0.83 0.79 0.69 0.0089 18/25

3.7 5 100L 7.2 2880 1.25 600 220 300 82.7 80.7 75.7 0.86 0.83 0.76 0.022 30/40

5.5 7.5 112M 11.00 2900 1.85 650 220 280 84.7 82.7 76.7 0.82 0.80 0.75 0.028 40/50

5.5 7.5 132S 10.7 2900 1.84 650 200 250 84.7 84.7 82.2 0.84 0.83 0.75 0.052 55

7.5 10 132S 13.8 2900 2.52 650 200 250 86 86 86 0.88 0.83 0.74 0.068 58

9.3 12.5 132M 17.00 2900 3.13 650 210 280 87 87 83.3 0.87 0.85 0.79 0.080 65

11 15 132M 20.00 2900 3.70 650 200 300 87.6 87.6 84.2 0.87 0.84 0.76 0.085 67

11 15 160M 20.00 2900 3.70 650 200 300 87.6 85.6 83.6 0.87 0.82 0.76 0.17 82

15 20 160M 27.50 2920 5.01 650 220 300 88.7 85.7 83.7 0.85 0.81 0.77 0.22 105

18.5 25 160L 33.00 2910 6.20 680 220 300 89.3 86.8 84.8 0.87 0.85 0.77 0.28 125

22 30 180M 38.00 2940 7.30 650 230 300 89.9 89.9 86.9 0.89 0.85 0.79 0.42 184

30 40 200L 52.00 2940 9.95 620 220 300 90.7 89.7 87.7 0.88 0.86 0.80 0.64 240

37 50 200L 63.00 2955 12.44 700 270 300 91.2 90.7 89.7 0.89 0.88 0.84 0.75 ---

45 60 225M 75.00 2950 14.87 650 200 300 91.7 91.2 88.2 0.91 0.90 0.89 0.91 295

55 75 250M 92.00 2965 18.09 700 210 300 92.1 91.1 90.1 0.90 0.89 0.85 1.8 595

75 100 280S 126 2965 24.70 700 190 270 92.7 92.7 91.2 0.89 0.85 0.77 6.63 725

90 120 280M 158 2970 29.65 700 190 270 93 93 91.5 0.85 0.81 0.77 8.18 775

110 150 315S 183 2970 36.11 700 180 270 93.3 93.3 91.8 0.89 0.83 0.75 11.55 1000

125 170 315M 203 2970 41.04 700 180 270 93.4 93.4 91.9 0.92 0.88 0.80 12.7 1150

132 180 315M 218 2970 43.33 700 180 270 93.5 93.3 92 0.90 0.86 0.78 13.89 1250

160 215 315L 260 2980 52.35 700 180 270 93.8 93.8 92.3 0.91 0.89 0.87 14.3 1400

200 270 315L 320 2980 65.44 700 180 270 94 94 92.5 0.92 0.87 0.88 18.87 1650

250 335 355L 398 2982 81.7 700 160 280 94 94 91.5 0.93 0.90 0.85 23.4 2150

315 425 355L 502 2982 102.9 700 160 280 94 94 92.5 0.93 0.90 0.85 29.7 2150

Note :
1. Motors in 63 to 112M frame with die cast Aluminum & in 132 to 355 frame in cast iron construction.
2. Motors in frame 63 to 112M frame can be offered with cast iron construction on request at extra

12
Table No. - 09
Electrical performance figures of Standard and Brake TEFC Foot, Flange & Face Mounted Three Phase
At 415 V +
_ 10%, 50 Hz +
_ 5% Four Pole Induction Motor

Rated Output Frame Rated Rated Rated Starting Starting Peak Efficiency % Power Factor Rotor Approx.
Size Current Speed Torque Current Torque Torque 2 Net
kW HP 100% 75% 50% 100% 75% 50% GD
Amps RPM kgm % of % of % of kg m sq Weight
Rated Rated Rated kg
Current Torque Torque AL/CI
0.12 0.16 63 0.40 1325 0.09 300 200 280 60 54 50 0.74 0.70 0.54 0.0014 6/10

0.18 0.25 63 0.65 1340 0.13 310 210 280 63 56 52 0.65 0.60 0.50 0.0014 4/10

0.25 0.33 71 0.70 1360 0.18 320 200 260 68 68 60 0.73 0.65 0.55 0.0034 8/14

0.37 0.5 71 1.00 1390 0.26 450 200 260 65.1 64.1 59.1 0.79 0.74 0.60 0.0034 8/14

0.55 0.75 80 1.40 1420 0.38 480 200 250 69.1 68.1 65.1 0.79 0.73 0.57 0.0077 11/16

0.75 1 80 1.80 1410 0.52 450 200 240 72.1 72.1 70.1 0.80 0.76 0.67 0.0086 10/16

1.1 1.5 90S 2.50 1400 0.77 570 200 260 75 75 69 0.81 0.73 0.61 0.014 20/30

1.5 2 90L 3.40 1410 1.04 560 190 240 77.2 77.2 74.2 0.79 0.77 0.59 0.010 25/35

2.2 3 100L 4.80 1430 1.50 590 200 250 79.7 79.7 77.7 0.80 0.79 0.66 0.029 35/47

3.0 4 100L 6.40 1410 2.07 590 200 250 81.5 81.5 79.5 0.80 0.80 0.70 0.038 35/57

3.7 5 112M 7.70 1440 2.51 580 200 250 82.7 82.7 80.7 0.80 0.80 0.65 0.057 40/66

5.5 7.5 132S 11.00 1440 3.72 630 200 260 84.7 84.7 83.7 0.82 0.80 0.67 0.093 62

7.5 10 132M 14.50 1450 5.04 650 200 250 86 86 85 0.84 0.82 0.65 0.12 75

9.3 12.5 132M 20.00 1450 6.25 650 190 280 87.3 87.3 86.3 0.74 0.71 0.64 0.14 83

9.3 12.5 160M 18.50 1450 6.25 620 200 250 88.3 88.2 87.3 0.79 0.78 0.69 0.17 95

11 15 160M 22.00 1440 7.45 600 200 250 87.6 86.6 85.6 0.79 0.79 0.73 0.20 110

15 20 160L 28.50 1460 10.02 600 250 270 88.7 87.7 87.7 0.81 0.81 0.74 0.26 130

18.5 25 180M 34.00 1460 12.35 600 250 270 89.3 88.3 87.3 0.84 0.77 0.60 0.66 175

22 30 180L 40.00 1460 14.69 600 250 270 89.9 89.9 88.9 0.85 0.82 0.78 0.84 210

30 40 200L 54.00 1465 19.97 600 250 270 90.7 90.7 89.7 0.85 0.83 0.78 1.19 247

37 50 225S 66.00 1470 24.54 600 230 280 91.2 91.2 90.2 0.85 0.84 0.78 1.46 255

45 60 225M 78.00 1470 29.85 600 230 280 91.7 90.7 90.7 0.87 0.86 0.79 1.71 310

55 75 250M 96 1475 36.36 650 250 280 92.1 92.1 91.1 0.86 0.85 0.78 3.20 625

75 100 280S 131 1480 49.41 650 250 280 92.7 92.2 91.2 0.85 0.83 0.81 7.21 720

90 120 280M 156 1480 59.29 650 250 280 93 92.5 91.5 0.85 0.83 0.80 8.25 775

110 150 315S 191 1485 72.08 650 225 255 93.3 93.3 90.8 0.84 0.82 0.80 11.62 1000

125 170 315M 215 1485 81.91 650 225 255 93.4 93.4 90.9 0.86 0.84 0.82 12.8 1100

132 180 315M 227 1485 96.49 650 225 255 93.5 93 92.5 0.87 0.85 0.83 13.98 1225

160 215 315L 271 1485 105.05 650 250 280 93.8 93.5 92.5 0.87 0.83 0.75 27.88 1400

180 250 315L 314 1485 118.34 650 240 270 94 94 92.7 0.85 0.81 0.73 29.30 1650

200 270 315L 339 1485 131.31 650 250 280 94 94 92.5 0.87 0.82 0.75 30.74 1800

225 300 355L 378 1488 147 650 180 230 94.1 94.1 92.6 0.88 0.85 0.80 34.1 2000

250 335 355L 421 1488 163.4 650 180 230 94 94 93 0.88 0.85 0.81 38.1 2100

315 425 355L 531 1488 205.6 650 180 230 94 93.5 92.5 0.88 0.85 0.85 48.3 2150

Note :
1. Motors in 63 to 112M frame with die cast Aluminum & in 132 to 355 frame in cast iron construction.
2. Motors in 63 to 112M frame can be offered with cast iron construction on request at extra cost.

13
Table No. - 10
Electrical performance figures of Standard and Brake TEFC Foot, Flange & Face Mounted Three Phase
At 415 V +
_ 10%, 50 Hz +
_ 5% Six Pole Induction Motor

Rated Output Frame Rated Rated Rated Starting Starting Peak Efficiency % Power Factor Rotor Approx.
kW HP Size Current Speed Torque Current Torque Torque 100% 75% 50% 100% 75% 50% GD Net
Amps RPM kgm % of % of % of kg m sq Weight
Rated Rated Rated kg
Current Torque Torque Al/CI
0.18 0.25 71 0.70 900 0.27 370 190 240 60 56 50 0.65 0.58 0.48 0.0044 7/10

0.25 0.33 71 1.00 890 0.36 340 190 240 60 58 50 0.60 0.58 0.52 0.0044 7/10

0.37 0.5 80 1.40 900 0.40 320 190 250 63 63 62 0.58 0.55 0.51 0.0070 10/16

0.55 0.75 80 1.80 900 0.60 320 190 260 67 66 63 0.63 0.58 0.54 0.0093 12/18

0.75 1 90S 2.10 950 0.77 400 200 280 70 69 89 0.70 0.64 0.57 0.016 16/26

1.1 1.5 90L 3.00 940 1.14 400 200 280 72.9 68.9 66.9 0.70 0.60 0.52 0.020 25/35

1.5 2 100L 3.70 930 1.57 400 190 290 75.2 72.2 66.2 0.75 0.67 0.59 0.032 33/45

2.2 3 112M 5.20 945 2.27 400 190 250 77.7 77.7 76.7 0.74 0.68 0.62 0.072 44/55

3.7 5 132S 8.00 960 3.76 450 190 250 80.9 80.9 79.9 0.79 0.75 0.69 0.13 62

5.5 7.5 132M 12.00 950 5.64 540 230 280 83.1 83.1 82.1 0.76 0.76 0.72 0.17 75

7.5 10 160M 15.50 960 7.62 600 200 250 84.7 84.7 83.7 0.79 0.73 0.64 0.43 81

9.3 12.5 160L 19.00 960 9.45 650 220 250 87 87 86 0.78 0.74 0.62 0.58 135

11 15 160L 21.00 970 11.06 650 220 300 86.4 86.4 85.7 0.84 0.75 0.62 0.66 144

15 20 180L 28.00 960 15.23 650 230 300 87.7 87.7 86.7 0.84 0.81 0.71 1.03 187

18.5 25 200L 34.00 980 18.41 600 230 300 88.6 88.6 87.6 0.84 0.79 0.73 1.43 233

22 30 200L 41.00 980 21.89 620 230 280 89.2 89.2 88.2 0.82 0.78 0.72 1.57 245

30 40 225M 55.00 980 29.85 600 210 250 90.2 90.2 89.2 0.84 0.80 0.74 2.30 310

37 50 250M 67.00 980 36.81 600 210 250 90.8 90.3 89.3 0.84 0.80 0.74 3.60 625

45 60 280S 80 980 44.77 600 230 260 91.4 91.4 89.4 0.85 0.82 0.73 8.01 720

55 75 280M 97 980 54.72 650 200 230 91.9 91.4 90.9 0.85 0.81 0.73 9.89 805

75 100 315S 131 985 74.62 650 225 255 92.6 92.1 91.1 0.86 0.82 0.74 14.12 1000

90 120 315M 157 985 89.09 650 225 255 92.9 92.4 91.7 0.85 0.81 0.73 17.0 1180

110 150 315M 191 985 108.88 650 225 255 93.3 93.3 92.3 0.86 0.82 0.70 18.98 1300

132 180 315L 229 985 130.66 650 230 280 93.5 93.5 92.5 0.87 0.83 0.75 29.94 1400

160 270 355L 351 988 196.57 650 160 200 94 93 90.5 0.84 0.81 0.72 37.5 2150

250 335 355L 434 990 245.2 650 160 200 94 93.5 92.5 0.85 0.82 0.73 46.6 2170

Note :
1. Motors in 63 to 112M frame with die cast Aluminum & in 132 to 355 frame in cast iron construction.
2. Motors in 63 to 112M frame can be offered with cast iron construction on request at extra cost.

14
Table No. - 11
Electrical performance figures of Standard and Brake TEFC Foot, Flange & Face Mounted Three Phase
At 415 V +
_ 10%, 50 Hz +
_ 5% Eight Pole Induction Motor
Rated Output Frame Rated Rated Rated Starting Starting Peak Efficiency % Power Factor Rotor Approx.
2
kW HP Size Current Speed Torque Current Torque Torque 100% 75% 50% 100% 75% 50% GD Net
Amps RPM kgm % of % of % of kg m sq Weight
Rated Rated Rated kg
Current Torque Torque AL/CI
0.18 0.25 80 1.00 660 0.27 200 180 240 50 48 44 0.50 0.47 0.42 0.0089 10/16

0.25 0.33 80 1.20 680 0.36 250 180 250 56 52 48 0.52 0.50 0.44 0.0089 12/18

0.37 0.50 90S 1.40 680 0.53 300 170 250 62 60 60 0.63 0.54 0.50 0.0158 18/26

0.55 0.75 90L 2.10 700 0.77 400 190 250 66 64 62 0.63 0.55 0.50 0.0196 27/35

0.75 1 100L 2.50 700 1.04 400 190 250 72 70 65 0.68 0.62 0.54 0.032 32/44

1.1 1.5 100L 3.30 710 1.51 400 190 250 74 74 72 0.69 0.62 0.54 0.042 37/50

1.5 2 112M 4.00 710 2.06 400 190 250 78 76 72 0.70 0.62 0.54 0.067 43/55

2.2 3 132S 5.40 710 3.02 450 200 260 82 81 79 0.66 0.68 0.60 0.12 66

3.7 5 132M 10.00 720 5.01 500 200 260 82 80 78 0.75 0.62 0.56 0.20 75

3.7 5 160M 8.20 720 5.01 500 200 260 84 83 82 0.73 0.70 0.64 0.37 85

5.5 7.5 160M 12.50 720 7.45 500 200 260 87 86 84 0.74 0.70 0.62 0.46 100

7.5 10 160L 16.00 720 10.16 500 210 240 88 86 84 0.77 0.70 0.63 0.57 125

11 15 180M 23.00 735 14.59 500 210 280 90 89 87 0.76 0.72 0.68 1.29 200

15 20 200L 32.00 735 19.90 500 210 290 90 89 88 0.76 0.72 0.64 1.70 258

18.5 25 225S 37.00 735 24.54 500 200 290 90 89 88 0.79 0.78 0.74 2.30 345

22 30 225M 43.00 735 29.18 500 200 260 90 89 88 0.80 0.78 0.74 2.60 375

30 40 250M 57.00 735 39.80 500 200 260 91 90 89 0.80 0.78 0.74 4.40 465

37 50 280S 71 735 49.08 500 210 260 91.5 91.5 89 0.79 0.76 0.67 8.01 600

45 60 280M 91 740 59.29 500 210 240 92 92 90.5 0.75 0.71 0.63 9.89 720

55 75 315S 106 740 72.47 600 200 240 92.5 92.5 91 0.78 0.74 0.66 14.12 900

75 100 315M 144 740 98.82 600 200 230 93 93 91.5 0.78 0.74 0.66 18.98 950

90 120 315L 171 740 118.58 600 250 230 94 94 92 0.78 0.74 0.66 29.94 1130

110 150 315L 209 740 144.93 600 250 280 94 94 92.5 0.78 0.74 0.66 29.94 1130

132 180 315L 250 740 173.92 600 250 280 94.5 94.5 92.5 0.78 0.74 0.66 33.28 1130

200 270 355L 403 745 261.48 600 185 200 94.5 94.5 92.5 0.73 0.66 0.56 37.5 2150

Note : 1. Motors in 63 to 112M frame with die cast Aluminum & in 132 to 355 frame in cast iron construction.
2. Motors in 63 to 112M frame can be offered with cast iron construction on request at extra cost.

15
11.0 Brake Motors

11.1 Salient Features


11.2 Construction
1. Simple construction and installation : The operation of the brake is fail-safe type i.e. Normally 'ON'. The brake is applied
when the power to the motor is cut off or power failure occurs. Being of simple and robust construction. these motors need
very little maintenance. In the rare event of failure it can be repaired easily and quickly. Spacial brake liners are used to
ensure that the braking torque remains constant throughout the use. Compensation for liner wear is very simple. Also the
torque adjustment is very easy. The breaking torque can be adjusted by rotating torque adjustment ring. The brake motor
facilitates easy replacement of armature disc in the event of wear and tear.
2. Manual Release is provided for brakes up to brakes up to 200 Frames. In case of power failure or in case of maintenance,
the manual release can be pushed back for releasing the brake.
3. Dust-Protecting seal is provided for protection of brake liners form dust.
4. The Switching Time of the brake motor is very fast, almost instantaneous.
5. The brake motor is provided with the rectifier unit. Therefore, no separate D.C. Supply is necessary for energizing the brake
coil. Varistor is provided across the D.C. Terminals to protect the brake coil and rectifier against line and induced voltages,
due to switching.
6. Normally 'OFF' type brakes can also be offered on request. These type of brakes are very compact in design & have high
operating reliability. The liners are made of special friction material & the brake is almost maintenance free.
7. A.C. Fail Safe brake motors can be offered on request.
8. DC side switching only for our geared brake motors.

11.3 Working
In the event of power failure, the braking torque in applied by an axial force of several compression springs. Pressing the
armature plate against the rotor. The rotor is then pushed against the mounting flange or a suitable face.

11.4 Switching
Our Brake motors require D.C. supply voltage, (190VDC) which can be obtained through A.C. Or D.C. rectification. Normally
switching is carried out on the A.C. side. However, for much faster engagement / disengagement time, switching is carried out on
the D.C. side for which a suitable arc suppressor and capacitor is a must to protect the coil and switching from high induction
voltage engagements and for switching purpose, please refer to brake coil connection diagram. For hoisting and lift application,
only DC side swithching is recommended.

11.5 Output Ratings


As per Table 02

11.6 Braking Torque


Braking-torque depends upon the output rating, speed and application of the motor. Therefore, customers are requested to
contact LHP for proper selection of the brake for intended application.

11.7 Dimensional Specifications

Please refer to table no. 3, 4, 5 for detailed dimensions of brake motors.

11.8 Connection Diagrams for Brake Coil

RYB C1 RYB C1 RYB C1


U MONITOR U U MONITOR
V V MONITOR V
W TERMINALS W TERMINALS W TERMINALS

C2 C2

BRAKE
BRAKE RECTIFIER COIL RECTIFIER
COIL D. C. BRAKE COIL
BRAKE SWITCHING ON A.C. SIDE BRAKE SWITCHING ON D.C. SIDE BRAKE SWITCHING ON D.C. SIDE

16
Selection of Brake size recommended by LHPL

The necessary torque for selecting the Brake size can be calculated by applying the
formula given below,

9550 x 0.75 x P
T= xK
RPM

Where T= Torque in N.M.


P= Power of Motor in HP.
RPM = Speed of Motor per minute
K= Safety factor, which is to be considered depending on load & inertia on motor.
For Typical applications K shall be selected as per guidelines given below.

Load Condition Safety Factor (K)


Low masses, equal loading & non-intermittent operation 2.0
Low masses, light shock loading & intermittent operation 2.5
Medium & large masses, light shock loading and intermittent operation 3.0
For Lifts & Hoist applications (Vertical & down movement)
3.0
Long travel or cross travel in cranes. 2.0

17
12.0 Crane Duty Motors

12.1 Special Features


1. Ideal for frequent starts / stops and reversing reversing operations in material handling, lifts cranes, hoists and rolling mills.
2. Positive locking between rotor and shaft is provided with a keyed joint.
3. Motors can be supplied with electromagnetic fail-safe D.C. brakes.
4. All crane duty motors are with D.O.L. Starting and F class Insulation.

12.2 Selection of Motors


The kilowatt requirement of the motor can be obtained by the following formula.
1. For Horizontal Motion :
Where :
P = Power required (kW)
FXV
P= F = Max. total load in kg
102 X n V = Hoisting speed in Mtrs./Sec.
n = O/A Eff. of the driving unit.
2. For Rotary Motion :
Where :
MXN
P = 975 X n kW M = Torque for movement in kg. m.
N = Motor speed in RPM
Ensure the rated output of motor is greater than the power PL.
Depending upon the duty classes usually required by the crane manufacturer as explained above, the motors are classified into
three classes of starting : 60 Stars / hr, 150 Starts / hr, 300 Starts / hr.
LHP Motors are standardized such that they are suitable for all the three classes of starting.
For purpose of thermal rating the equivalent duty is class S2 - 60 minutes.

12.3 Classes of Duty & Duty Cycles FIG. - 1


Motors are suitable for : N
A Continuous Duty (S1)
B Short Time Duty (S2) Load
C Intermittent Periodic Duty (S3)
D Intermittent Duty with Starting & Electrical
Braking (S5)
Electric
Losses

1. Continuous Duty O Max.


Operation of constant load of sufficient duration for Temp
thermal equilibrium to be reached.

Note : Crane Duty motors are suitable only for


continuous duty for 1 hour. TIME N : Operation at Constant Load
O : Maximum Temp. attained

2. Short Time Duty Period of cycle


The motor operated at a constant load for some FIG. - 2
specified time which is then followed by periods of rest. N

The period for load is so short that the motor cannot


reach its thermal equilibrium i.e. steady temp, rise Load
while the period for rest is so long that the motor temp.
drops to the ambient temp. The simplified diagram for
short time duty is shown in Flg. 02. Standard short time
Electric
rating are 10, 30 & 90 minutes. Losses

Temp O Max.

N : Operation at Constant Load


O : Maximum Temp. attained
0
during duty cycle in C
TIME

18
3. Intermittent Periodic Duty PERIOD OF CYCLE
On intermittent duty the period of constant load & rest with FIG. - 3
machine de-energised alternately. The load periods are too short N R
to allow the motor to reach its final thermal steady state value while
periods of rest are also too small to allow the motor to cool down to
the ambient temp. The simplified load for this type of duty is shown Load
in Fig. 3.
For evaluation of intensity of heating due to intermittent periodic
Electric
loads, duty factor is used. The duty factor (also called as cyclic Losses
duration factor) is generally defined as the ratio of the heating
period to the period of whole cycle.
Temp O Max.

N : Operation at constant Load


N R : Operation at rest &
So, Cycle Duration Factor = de-energized
N+R TIME O : Maximum Temp. attained
during duty cycle in 0c
X : Period of one cycle

PERIOD OF CYCLE
4. Intermittent Periodic Duty with Starting
FIG. - 4
This type of duty consists of a sequence of identical duty cycles, D N R
each consisting of starting a period, the operation & rest period are
too short to attain thermal equilibrium during cycle as shown in Load
Fig. 04.
In this duty, the stopping of the motor is obtained either by natural
deacceleration after disconnection of the electric supply or by Electric
means of breaking such as mechanical brake which does not Losses

cause additional heating of the motor.

Temp O Max.

D : Starting Period
N : Operation under rated
condition
TIME R : At rest & de-energized
O : Maximum Temp. attained
o
during duty cycle in C

The cycle D+N


duration =
5. Intermittent periodic Duty with Starting & Breaking factor D+N+R
PERIOD OF CYCLE
This type of duty consists of sequence of identical duty cycles each
consisting of a period of starting, a period of operation at constant D N R
load, a period of braking and a period of rest. The operating & rest FIG. - 5
periods are too short to obtain thermal equilibrium during one duty Load
cycle shown in Fig. no. 4. In this duty the braking is rapid & is
carried out by electrical means.
Electric
Losses
D+N+ F
The duty factor (CDF) =
D+N+F+R
Temp O Max.

D : Starting Period
N : Operation under rated
TIME condition
F : Braking period
R : At rest & de-energized
O : Maximum Temp. attained
o
during duty cycle in C
12.4 Dimensional Specification Data
Please refer to the table no. 3, 4 for detailed dimensions of crane duty motors.

12.5 Electrical Performance


Please refer to the table no. 12 & 13

19
Table No. - 12
Electrical performance figures of Crane duty, TEFC, Foot, Flange and Face Mounted Three Phase
At 415 V, 50 Hz Four Pole Induction Motor
Rated Output Frame Rated Rated Rated Starting Starting Peak Efficiency Power Rotor Approx.
Size Current Speed Torque Current Torque Torque % Factor 2 Net
kW HP GD
Amps RPM kgm % of % of % of kg m sq Weight
Rated Rated Rated kg
Current Torque Torque
0.37 0.5 71 1.40 1320 0.27 300 240 300 62 0.59 0.0036 8

0.55 0.75 71 1.90 1300 0.41 300 200 300 62 0.65 0.0040 8

0.75 1.0 80 2.40 1320 0.55 250 200 300 70 0.62 0.0069 11

1.1 1.5 80 2.70 1250 0.86 400 200 300 71 0.80 0.010 14

1.5 2.0 90L 3.40 1380 1.06 450 200 300 74 0.83 0.011 25

2.2 3.0 90L 5.00 1350 1.59 450 220 300 76 0.81 0.013 26

3.0 4.0 100L 6.50 1410 2.07 600 200 300 80 0.80 0.029 32

3.7 5.0 100L 7.80 1420 2.54 600 220 300 82 0.80 0.041 38

5.5 7.5 112M 12.00 1390 3.86 500 200 300 84 0.76 0.053 46

7.5 10.0 132M 15.20 1390 5.26 500 200 300 84 0.82 0.12 71

9.3 12.5 132M 19.00 1420 6.39 500 220 300 86 0.79 0.15 80

11.0 15.0 160M 22.00 1450 7.40 500 230 300 86 0.81 0.30 90

15.0 20.0 160M 29.00 1450 10.09 500 200 300 88 0.82 0.33 100

Table No. - 13
Electrical performance figures of Crane duty, TEFC, Foot, Flange and Face Mounted Three Phase
At 415 V, 50 Hz Six Pole Induction Motor
Rated Output Frame Rated Rated Rated Starting Starting Peak Efficiency Power Rotor Approx.
kW HP Size Current Speed Torque Current Torque Torque % Factor GD Net
Amps RPM kgm % of % of % of kg m sq Weight
Rated Rated Rated kg
Current Torque Torque
0.18 0.25 71 0.82 880 0.28 300 200 300 60 0.51 0.0044 7

0.37 0.5 71 1.60 880 0.41 300 200 300 58 0.55 0.0044 7

0.55 0.75 80 2.00 880 0.61 300 200 300 65 0.59 0.007 12

0.75 1.0 80 2.60 900 0.81 300 200 300 71 0.57 0.011 14

1.1 1.5 90S 3.70 950 1.13 300 200 300 74 0.56 0.016 25

1.5 2.0 90L 4.60 920 1.59 350 210 300 74 0.61 0.020 27

2.2 3.0 100L 6.00 920 2.33 450 210 300 74 0.69 0.042 37

3.7 5.0 112M 9.20 920 3.92 400 200 300 78 0.72 0.077 46

5.5 7.5 132S 12.50 940 5.70 500 210 300 82 0.75 0.13 62

7.5 10.0 132M 17.00 920 7.95 500 200 300 82 0.75 0.19 80

9.3 12.5 160M 19.00 960 9.45 600 220 300 86 0.79 0.49 88

11.0 15.0 160M 22.50 910 11.79 600 240 300 85 0.80 0.49 100

15.0 20.0 160L 32.00 950 15.39 600 230 300 88 0.74 0.66 125

13.0 Dual Speed Motors


LHPL, developed Dual Speed Motor for polarity ratio - 2/4P, 4/8P, 6/8P,6/12P. The frame size outputs are confirmed subject to knowing :
a) Complete application details
b) Duty cycle/loading cycle
c) Method of braking
2
d) Load GD referred to motor shaft
Winding of dual speed motors : There are two types of winding techniques which are used in the motors :
a) Tapped winding (Also called Dahlandar winding) : where the two speeds are in ratio of 2 to 1
b) Separate windings : One for each speed, when the output speed is other than 2 to 1 ratio. The latter results in considerable reduction
in output rating.

20
Electrical performance Figures of standard TEFC Foot, flange & Face Mounted,
Single phase at 230V, 50HZ, S1 duty, IP : 55, F Class, 40°C Amd.

Table No. - 14 2 Pole - CSR


Sr. No. Parameters

1 KW/HP 0.18/0.25 0.37/0.5 0.55/0.75 0.75/1 1.1/1.5 1.5/2

2 Pole 2 2 2 2 2 2

3 Frame 63 71 71 80 90 90

4 Full Load RPM 2800 2800 2800 2800 2900 2820

5 Rated Current 1.8A 3A 3.8A 5.4A 8A 10A

6 Power Factor 0.99 0.98 0.99 0.99 0.98 0.92

7 Full Load Torque 0.05KGM 0.127KGM 0.19KGM 0.24KGM 0.37KGM 0.5KGM

8 % Starting Torque/Full Load Torque 50% 40% 40% 40% 40% 40%

9 Bearing DE 6201 6203 6203 6204 6205 6205

10 Bearing NDE 6201 6203 6203 6204 6205 6205

11 Ref. Std. IS:996 IS:996 IS:996 IS:996 IS:996 IS:996

Table No. - 15 4 Pole - CSR


Sr. No. Parameters

1 KW/HP 0.18/0.25 0.37/0.5 0.55/0.75 0.75/1 1.1/1.5 1.5/2

2 Pole 4 4 4 4 4 4

3 Frame 71 80 80 80 90 100

4 Full Load RPM 1400 1400 1440 1400 1360 1410

5 Rated Current 1.8A 2.5A 3.8A 5.2A 7A 11.5A

6 Power Factor 0.84 0.99 0.99 0.98 0.99 0.96

7 Full Load Torque 0.125KGM 0.25KGM 0.373KGM 0.51KGM 0.78KGM 1.01KGM

8 % Starting Torque/Full Load Torque 63% 45% 35% 40% 40% 40%

9 Bearing DE 6203 6204 6204 6205 6205 6206

10 Bearing NDE 6203 6204 6204 6205 6205 6206

11 Ref. Std. IS:996 IS:996 IS:996 IS:996 IS:996 IS:996

21
Electrical performance Figures of standard TEFC Foot, flange & Face Mounted,
0
Single phase at 230V, 50HZ, S1 duty, IP :55 F Class, 40 C Amd.

Table No. - 16 4 Pole - CSIR

Sr. No. Parameters

1 KW/HP 0.18/0.25 0.37/0.5 0.55/0.75 0.75/1 1.1/1.5 1.5/2

2 Pole 4 4 4 4 4 4

3 Frame 80 80 90L 90L 90L 100L

4 Full Load RPM 1400 1400 1400 1430 1410 1410

5 Rated Current 2.4A 4.2A 6A 7A 10A 14A

6 Power Factor 0.64 0.65 0.81 0.71 0.77 0.76

7 Full Load Torque 0.25KGM 0.25KGM 0.38KGM 0.51KGM 0.76KGM 1.03KGM

8 % Starting Torque/Full Load Torque 200% 180% 180% 190% 180% 190%

9 Bearing DE 6204 6204 6205 6205 6205 6205

10 Bearing NDE 6205 6205 6205 6205 6205 6205

11 Ref. Std. IS:996 IS:996 IS:996 IS:996 IS:996 IS:996

Table No. - 17
4 Pole - CSCR

Sr. No. Parameters

1 KW/HP 0.18/0.25 0.37/0.5 0.55/0.75 0.75/1 1.1/1.5 1.5/2

2 Pole 4 4 4 4 4 4

3 Frame 71 80 80 80 90L 100L

4 Full Load RPM 1420 1410 1410 1410 1385 1440

5 Rated Current 2.5A 3.6A 3.6A 6.2A 7.5A 11A

6 Power Factor 0.75 0.76 0.94 0.98 0.98 0.85

7 Full Load Torque 0.123KGM 0.25KGM 0.38KGM 0.51KGM 0.77KGM 1.02KGM

8 % Starting Torque/Full Load Torque 200% 180% 190% 190% 200% 196%

9 Bearing DE 6205 6205 6205 6205 6205 6206

10 Bearing NDE 6203 6204 6204 6204 6205 6205

11 Ref. Std. IS:996 IS:996 IS:996 IS:996 IS:996 IS:996

22
15.0 Energy Efficient Motors (IE-2)

LHP Energy Efficient Motors conform to Energy Efficiency


Level I (IS : 12615) Range Up to 315 kW
Suitable for continuous process industries where high energy RPM 3000, 1500, 1000, 750 (synchronous)
saving is essential Short payback period for replacement Mounting Foot (B-3), Flange (B-5), Face (B-14)
Enhanced motor life Less maintenance and combinations
Applications : Frame 71 to 355 L
Machine tools, Textile, Air conditioning, Diary equipment, Packing Protection IP 55
machinery, Material handling equipment, Geared Motors, Wood Insulation F class
seasoning plants, Solvent Extraction plants, Edible oil factories,
Voltage 415 V, 380 V or as per requirement
Cement, paper & steel plants.
Frequency 50 HZ / 60 HZ or as per requirement
Applicable Standards
IS : 4722 Specifications for rotating electrical machine
IS : 325 (IEC 34 - 1) Specifications for 3 phase induction motors
IS : 4691 (IEC 34 - 5) Degrees of protection provided by enclosure for rotating electrical machines
IS : 4889 (IEC 34 - 2) Method of determination of efficiency of rotating electrical machines
IS : 12615 (IEC 34-30) Specifications for Energy Efficiency Induction Motors
IS : 12824 Type of duty and class of rating assigned to rotating electrical machines

Table No. - 18
Performance figures of Energy Efficient Sq. Cage 2 Pole Induction Motors Conforming to IS : 12615 (IE-2)
Output Efficiency Power Factor
Frame Speed Current
kW HP FL 3/4 FL 1/2 FL FL 3/4 FL 1/2 FL
0.37 0.5 71 2800 72.2 72.2 70 0.75 0.73 0.64 0.95
0.55 0.75 71 2800 74.8 74.8 72.8 0.79 0.74 0.66 1.3
0.75 1 80 2800 77.4 76.4 74.4 0.82 0.82 0.72 1.65
1.1 1.5 80 2820 79.6 79.6 77.6 0.83 0.80 0.73 2.3
1.5 2 90S 2820 81.3 81.3 78 0.85 0.81 0.79 3
2.2 3 90L 2845 83.2 83.2 81.6 0.87 0.84 0.82 4.2
3.7 5 100L 2900 85.5 84.5 83 0.87 0.85 0.82 6.9
5.5 7.5 132S 2900 87 87 85 0.85 0.84 0.80 10.3
7.5 10 132S 2920 88.1 88.1 86.1 0.84 0.83 0.79 14
9.3 12.5 160M 2900 89.3 89.3 88.3 0.87 0.85 0.79 16.6
11 15 160M 2900 89.4 89.4 87.4 0.87 0.85 0.80 19.5
15 20 160M 2920 90.3 90.3 88.3 0.90 0.87 0.82 25.5
18.5 25 160L 2900 90.9 90.9 88.9 0.88 0.83 0.80 32
22 30 180M 2945 91.3 91.3 89.3 0.90 0.87 0.82 37
30 40 200L 2940 92 92 90 0.88 0.87 0.82 51.5
37 50 200L 2900 92.5 92.5 90.5 0.87 0.86 0.80 64
45 60 225M 2930 92.9 92.9 91.7 0.88 0.84 0.80 76
55 75 250M 2950 93.2 93.2 92.2 0.86 0.83 0.80 95
75 100 280S 2950 93.8 93.8 92.7 0.85 0.83 0.79 130
90 120 280M 2965 94.1 94.1 91.3 0.85 0.82 0.76 156
110 150 315S 2965 94.3 94.3 93.3 0.87 0.83 0.77 186
125 170 315M 2970 94.5 94.5 93.7 0.88 0.84 0.78 209
132 180 315M 2970 94.6 94.6 93.8 0.89 0.85 0.79 220
160 215 315L 2980 94.8 94.8 94 0.90 0.88 0.87 260

23
Table No. - 19
Performance figures of Energy Efficient 4 Pole Sq. Cage Induction Motors Conforming to IS : 12615 (IE-2)
Output Efficiency Power Factor
Frame Speed Current
kW HP FL 3/4 FL 1/2 FL FL 3/4 FL 1/2 FL
0.37 0.5 71 1340 70.1 70.1 69.1 0.73 0.69 0.66 1
0.55 0.75 80 1350 75.1 75.1 73.1 0.78 0.76 0.71 1.3
0.75 1 80 1385 79.6 79.6 76.1 0.72 0.70 0.60 1.8
1.1 1.5 90S 1435 81.4 81.4 80.6 0.69 0.68 0.65 2.7
1.5 2 90L 1430 82.8 82.8 80.3 0.72 0.70 0.66 3.5
2.2 3 100L 1450 84.3 84.3 82.3 0.80 0.78 0.74 4.5
3.7 5 112M 1445 86.3 86.3 84 0.78 0.76 0.72 7.6
5.5 7.5 132S 1450 87.7 87.7 86 0.85 0.83 0.77 10.2
7.5 10 132M 1450 88.7 88.7 87.6 0.84 0.80 0.73 14.0
9.3 12.5 160M 1455 89.8 89.8 89.3 0.84 0.82 0.75 17
11 15 160M 1460 89.8 89.8 89.1 0.85 0.83 0.79 20
15 20 160L 1465 90.6 90.6 90.1 0.82 0.80 0.75 28
18.5 25 180M 1455 91.2 91.2 89.6 0.85 0.83 0.79 33
22 30 180L 1460 91.6 91.6 91 0.83 0.80 0.74 40
30 40 200L 1450 92.3 92.3 91.1 0.87 0.85 0.76 52
37 50 225S 1475 92.7 92.7 92.2 0.85 0.82 0.74 65
45 60 225M 1475 93.1 93.1 92.4 0.88 0.83 0.77 76
55 75 250M 1470 93.5 93.5 91.3 0.87 0.85 0.76 94
75 100 280S 1480 94 94 92.3 0.82 0.79 0.72 135
90 125 280M 1480 94.2 94.2 92.7 0.85 0.83 0.74 155
110 150 315S 1485 94.5 94.5 93.2 0.85 0.83 0.74 190
125 170 315M 1485 94.6 94.6 93.2 0.85 0.82 0.72 215
132 180 315M 1485 94.7 94.7 93.2 0.86 0.84 0.85 225
160 215 315L 1487 94.9 94.8 93.6 0.87 0.84 0.75 269

24
Table No. - 20
Performance figures of Energy Efficient Sq. Cage 6 Pole Induction Motors Conforming to IS : 12615 (IE-2)
Output Efficiency Power Factor
Frame Speed Current
kW HP FL 3/4 FL 1/2 FL FL 3/4 FL 1/2 FL
0.37 0.5 80 900 69 69 67.6 0.57 0.54 0.50 1.3
0.55 0.75 80 900 72.9 72.9 70.4 0.62 0.59 0.54 1.7
0.75 1 90S 920 75.9 75.6 72.4 0.65 0.62 0.55 2.1
1.1 1.5 90L 920 78.1 78.1 71.1 0.70 0.67 0.61 2.8
1.5 2 100L 930 79.8 79.8 72.8 0.72 0.69 0.64 3.6
2.2 3 112M 945 81.8 81.8 77.8 0.72 0.68 0.62 5.2
3.7 5 132S 960 84.3 84.3 80.3 0.76 0.72 0.60 8
5.5 7.5 132M 950 86 86 83.2 0.74 0.69 0.61 12
7.5 10 160M 960 87.2 87.2 83.7 0.78 0.70 0.62 15.2
9.3 12.5 160L 960 88.5 88.5 85 0.81 0.75 0.65 18
11 15 160L 970 88.7 88.5 86.5 0.82 0.79 0.69 21
15 20 180L 960 89.7 89.7 88.2 0.83 0.79 0.79 28
18.5 25 200L 980 90.4 90.4 88.6 0.86 0.81 0.71 33
22 30 200L 980 90.9 90.7 88.9 0.84 0.79 0.66 40
30 40 225M 980 91.7 91.7 89.3 0.84 0.79 0.71 54
37 50 250M 980 92.2 92.2 90.2 0.82 0.78 0.71 68
45 60 280S 980 92.7 92.7 90.5 0.82 0.78 0.70 82
55 75 280M 985 93.1 93.1 89.6 0.88 0.80 0.70 98
75 100 315S 985 93.7 93.7 90.5 0.82 0.81 0.72 135
90 125 315M 985 94 94 91.7 0.78 0.77 0.70 169
110 150 315M 990 94.3 94.3 92.5 0.81 0.80 0.72 200
132 170 315L 990 94.6 94.6 93.2 0.82 0.80 0.73 235
Table No. - 21
Performance figures of Energy Efficient Sq. Cage 8 Pole Induction Motors
Output Efficiency Power Factor
Frame Speed Current
kW HP FL 3/4 FL 1/2 FL FL 3/4 FL 1/2 FL
0.37 0.5 90S 680 66.80 66.80 66.40 0.55 0.53 0.48 1.4
0.55 0.75 90L 700 71.10 71.10 70.00 0.54 0.52 0.48 2.0
0.75 1 100L 700 73.8 73.80 72.30 0.59 0.55 0.50 2.4
1.1 1.5 100L 710 76.20 76.20 75.40 0.65 0.62 0.58 3.1
1.5 2 112M 710 78.5 78.5 75.00 0.70 0.69 0.65 3.8
2.2 3 132S 710 80.50 80.50 77.80 0.66 0.60 0.55 5.8
3.7 5 160M 720 83.00 83.00 82.00 0.80 0.72 0.60 7.8
5.5 7.5 160L 720 85.10 85.10 84.00 0.82 0.74 0.60 11
7.5 10 160L 720 86.40 86.40 85.00 0.72 0.66 0.60 16.7
9.3 12.5 180M 730 87.30 87.30 86.00 0.73 0.66 0.60 20.3
11 15 180L 735 88.10 88.10 87.00 0.75 0.68 0.58 23
15 20 200L 735 89.00 89.00 87.30 0.71 0.66 0.58 33
18.5 25 225S 735 89.80 89.80 88.20 0.82 0.76 0.66 35
22 30 225M 730 90.20 90.20 88.50 0.79 0.76 0.68 43
30 40 250M 730 91.50 91.50 88.70 0.79 0.76 0.66 58
37 50 280S 735 91.90 91.90 89.00 0.78 0.75 0.68 71
45 60 280M 735 92.40 92.40 89.20 0.78 0.75 0.66 87
55 75 315S 735 92.80 92.80 89.30 0.82 0.80 0.70 102
75 100 315M 735 93.50 93.50 89.30 0.80 0.78 0.68 138
90 125 315L 730 93.90 93.90 90.00 0.81 0.78 0.68 165
110 150 315L 735 94.30 94.30 90.60 0.81 0.78 0.68 200
25
Cooling Tower Motors

Range Up to 270 HP (200 kw) Applicable Standards


R.P.M. 1500, 1000, 750 Specifications for rotating electrical
IS - 4722
Pole 4/6/8 machine
Mounting B5 / Shaft downward position V1 IS - 325 (IEC 34 - 1) Specifications for 3 phase induction
Frame 71 to 315 L machine
IS - 4691 (IEC 34 - 5) Degree of protection provided by
Protection IP 55
enclosure for rotating electrical machines
Insulation F Class
IS - 4889 (IEC 34 - 2) Method of determination of efficiency of
Voltage 415 V, 380 V or as per requirment rotating electrical machines
Frequency 50 Hz / 60 Hz Dimensions of 3 phase flange mounted
IS - 2223 (IEC 72 - 1)
Duty S1 induction motors
Paint With Anti corrosive Epoxy paint

Table No. - 22
Frame
size M N P S X NO. T LA LB AD F G GA OD1 L1 D2 L2 D3 L3 X OA B
j6
71 130 110 160 10X4 3.5 10 180 115 5 11 16 17 55 14 25 M12 30 20 --- ---
j6
80 165 130 200 12X4 3.5 10 200 120 6 15.5 21.5 20 60 19 50 M16 30 45 --- ---
j6
90S 165 130 200 12X4 3.5 12 235 160 8 24 31 30 60 28 50 M24 50 45 5 8

90L 165 130 200 12X4 3.5 12 255 160 8 24 31 30 60 28j6 50 M24 50 45 5 8
k6
100L 215 180 250 15X4 4.0 12 270 155 8 24 31 30 60 28 50 M24 50 45 5 8

112M 215 180 250 15X4 4.0 12 280 170 8 24 31 30 60 28k6 50 M24 50 45 5 8
k6
132S 265 230 300 15X4 4.0 12 310 210 10 33 41 40 90 38 75 M30 50 65 5 8
k6
132M 265 230 300 15X4 4.0 12 350 210 10 33 41 40 90 38 75 M30 50 65 5 8

132M(N) 265 230 300 15X4 4.0 12 375 210 10 33 41 40 90 38k6 75 M30 50 65 5 8
k6
160M 300 250 350 19X4 5.0 13 420 233 12 37 45 45 90 42 75 M30 50 70 5 8
k6
160L 300 250 350 19X4 5.0 13 462 233 12 37 45 45 90 42 75 M30 50 70 5 8
k6
180M/L 300 250 350 19X4 5.0 13 520 256 14 42.5 51.5 50 100 48 105 M30 50 90 5 8
m6
200L 350 300 400 19X4 5.0 15 570 313 16 49 59 60 100 55 105 M30 50 95 5 10

2255/M 400 350 450 19X8 5.0 16 605 370 18 53 64 65 100 60m6 115 M30 50 100 5 10
m6
250M 500 450 550 19X8 5.0 22 695 415 18 58 69 70 100 65 115 M40 60 100 5 10
m6
280S/M 500 450 550 19X8 5.0 22 785 430 20 67.5 79.5 90 120 75 120 M40 60 100 5 10
m6
315L 600 550 660 24X8 6.0 22 935 520 22 71 85 95 130 80 120 M40 60 120 5 10

26
16.0 Flame - Proof Motors
16.1 Salient Features
1. LHP Flame - Proof motors are suitable for GAS GROUP I. IIA, IIB and IIC applications.
2. Suitable for temperature class T6 for motors in up to 90 frame size & T4 for motors in 100 & above frame sizes.
3. Motors are designed for continuous operation in explosive or inflammable atmosphere in coal mines. Chemical,
Petrochemical Industries, fertilizers & pharmaceutical industries.
4. Flame-Proof motors comply with IS/IEC 60079-1 specifications and rating performance as per IS : 325
5. Motors are suitable for horizontal & vertical mounting as per IS : 1231 & IS : 2223 & IEC 60072-2
6. Motor frames & end shields are made of grey cast iron with sturdy design & have high strength to prevent internal
explosion due to the external inflammable gas.
7. All fasteners used are provided with shrouds around their heads to prevent from opening easily i.e. Tamper-proof and
to maintain the graphs as specified. Also they are of a high tensile material (Minimum tensile strength 400 N/min2)
8. Motors terminals studs are of brass suitable for D.O.L. Strating up to 3HP (3 terminals) & above 3HP Star / Delta starting
provision is made (6 terminals). The insulating material of Terminal Studs is made up of Dough Moulding compound.
9. Motors with mining application (gas group - I) are provided with cable entries either with compound filling sealing box
or with Flameproof wiping type cable glands or with FLP Plug & Socket as required.
10. Flame-Proof compression glands suitable for armoured or unarmoured Copper or Alluminium cables can be given.
11. All motors are with top terminal box.
16.2 Approval / Certification
A.Flame - Proof motors carry the BIS mark (IS : 2148, IS/IEC60079- 0&1) and are tested by ERTL- Kolkata, CIMFR- Danbad
& Karandikar Test Lab., Mumbai.
B. Approval certifications of following are taken based on the test report issued by ERTL Kolkata & CIMFR, Danbad,
KLPL Mumbai.
1. Petroleum & Explosives Safety Organisation (PESO), Nagpur.
2. Directorate General of Mines Safety (DGMS), Dhanbad.
C. CE ATEX
16.3 Dimensional Details
Please refer to Table No. 22, 23 & 24

16.4 Electrical Performance


Please refer to Table No. 25, 26, 27 & 28
16.5 Frame - wise Outpur
Please refer to Table No. 2A
16.6 Frame wise Bearing sizes

Frame Bearing No.


Size DE NDE
63 6201 ZZ 6201 ZZ
71 6203 ZZ 6203 ZZ
80 6204 ZZ 6204 ZZ
90S/L 6205 ZZ 6205 ZZ
100L 6206 ZZ 6206 ZZ
112M 6306 ZZ 6206 ZZ
132S/M 6308 ZZ C3 6208 ZZ C3/6308 ZZ C3
160M/L 6309 ZZ C3 6309 ZZ C3/6209 ZZ C3
180M/L 6310 ZZ C3 6310 ZZ C3
200L 6312 ZZ C3 6312 ZZ C3
225S/M 6313 ZZ C3 6313 ZZ C3
250M 6314 C3 6314 C3
280S/M 6318 C3 6415 C3
315S/M/L 6319 C3 6319 C3
27
17.0 Dimensions of Foot Mounted Flame-Proof Motors (B-3 Mounting) as per IS : 1231

LF-90 to LF-160 Frame LF-71 to LF-160 Frame LF-90 to LF-315 Frame

LF-180 to LF-225 Frame

28
Dimensions of Foot Mounted Flame - Proof Motor (B3 MOUNTING As per IS : 1231)
Table No. - 23
Frame Size H C A AB HA OK B BB AD AD* OAC OD E F G GA TH L L MAX CG (METRIC) X
0.5 MAX MAX MAX For Brake Motor NOS.
63M 63 40 100 125 10 7 80 100 125 125 130 11j6 23 4 8.5 12.5 M5 250 -- M20 X 1
71M 71 45 112 140 10 7 90 115 135 135 145 14j6 30 5 11.0 16.0 M5 275 372 M20 X 1
80M 80 50 125 165 10 10 100 140 145 145 180 19j6 40 6 15.5 21.5 M6 300 415 M20 X 1
90S 90 56 140 180 12 10 100 170 247 243 192 24j6 50 8 20.0 27.0 M8 377 517 M20 X 1
90L 90 56 140 180 12 10 125 170 247 243 192 24j6 50 8 20.0 27.0 M8 377 517 M20 X 1
100L 100 63 160 208 13 12 140 188 262 258 217 28j6 60 8 24.0 31.0 M10 439 551 M20 X 1
112M 112 70 190 240 15 12 140 190 277 274 240 28j6 60 8 24.0 31.0 M10 462 588 M25 X 1
132S 132 89 216 265 16 12 140 240 294 291 272 38k6 80 10 33.0 41.0 M12 590 749 M25 X 1
132M 132 89 216 265 16 12 178 240 294 291 272 38k6 80 10 33.0 41.0 M12 590 749 M25 X 1
160M 160 108 254 314 18 15 210 314 319 320 316 42k6 110 12 37.0 45.0 M16 708 877 M40 X 2
160L 160 108 254 314 18 15 254 314 319 320 316 42k6 110 12 37.0 45.0 M16 708 877 M40 X 2
180M 180 121 279 340 25 15 241 340 413 360 358 48k6 110 14 42.5 51.5 M16 735 924 M40 X 2
180L 180 121 279 340 25 15 279 340 413 360 358 48k6 110 14 42.5 51.5 M16 735 924 M40 X 2
200L 200 133 318 390 25 19 305 380 413 415 381 55m6 110 16 49.0 59.0 M20 825 -- M40 X 2
225S (2P) 225 149 356 440 32 19 286 375 458 447 55m6 110 16 49.0 59.0 M20 850 -- M40 X 2
225S (4,6&8P) 225 149 356 440 32 19 286 375 458 447 60m6 140 18 53.0 64.0 M20 882 -- M40 X 2
225M (2P) 225 149 356 440 32 19 311 375 458 447 55m6 110 16 49.0 59.0 M20 850 -- M40 X 2
225M (4,6&8P) 225 149 356 440 32 19 311 375 458 447 60m6 140 18 53.0 64.0 M20 882 -- M40 X 2
250M (2P) 250 168 406 500 35 24 349 425 527 525 484 60m6 140 18 53.0 64.0 M20 987 -- M50 X 2
250M (4,6&8P) 250 168 406 500 35 24 349 425 527 525 484 65m6 140 18 58.0 69.0 M20 937 -- M50 X 2
280S (2P) 280 190 457 540 40 24 368 490 558 540 65m6 140 18 58.0 69.0 M20 1120 -- M50 X 2
280S (4,6&8P) 280 190 457 540 40 24 368 490 558 540 75m6 140 20 67.5 79.5 M20 1045 -- M50 X 2
280M (2P) 280 190 457 540 40 24 419 490 558 540 65m6 140 18 58.0 69.0 M20 1120 -- M50 X 2
280M (4,6&8P) 280 190 457 540 40 24 419 490 558 540 75m6 140 20 67.5 79.5 M20 1045 -- M50 X 2
315S (2P) 315 216 508 620 50 28 406 600 602 625 65m6 140 18 58.0 69.0 M20 1247 -- M50 X 2
315S (4,6&8P) 315 216 508 620 50 28 406 600 602 625 80m6 170 22 71.0 85.0 M20 1252 -- M50 X 2
315M (2P) 315 216 508 620 50 28 457 600 602 625 65m6 140 18 58.0 69.0 M20 1247 -- M50 X 2
315M (4,6&8P) 315 216 508 620 50 28 457 600 602 625 80m6 170 22 71.0 85.0 M20 1252 -- M50 X 2
315 (2P) 315 216 508 620 50 28 508 600 602 625 65m6 140 18 58.0 69.0 M20 1247 -- M50 X 2
315L (4,6&8P) 315 216 508 620 50 28 508 600 602 625 80m6 170 22 71.0 85.0 M20 1252 -- M50 X 2

* MARKED DIMENSION IS FOR GAS GROUP IIC APPLICATION MOTOR & OTHER DIMENSIONS ARE SAME AS ABOVE.
Note : Cable Gland size may be changed according to cable size as per customer requirement.
LF-250 to LF-315 Frame

29
18.0 Dimensions of Flange Mounted Flame-Proof Motors (B-5 Mounting) as per IS:2223
LF-63 to LF-80 Frame (IIA, IIB & IIC)

LF-90 to LF-160 Frame LF-71 to LF-160 Frame LF-90 to LF-315 Frame

LF-180 to LF-225 Frame

30
18.0 DIMENSIONS FOR FLANGE MOUNTED MOTORS (B5 MOUNTING) AS PER IS-2223
Table No. - 24
Frame Size Flange OM ON OP OS X T LA LD AD AD* OAC OD E F G GA TH L BRAKE MOTOR CG (METRIC)
No. 0.3 j6 MIN NO. MAX MAX MAX L MAX X NOS

63M F115B 115 95 140 10X4 3 10 -- 125 125 130 11j6 23 4 8.5 12.5 M5 250 -- M20 X 1
71M F130B 130 110 160 10X4 3.5 10 19 135 135 145 14j6 30 5 11 16 M5 280 372 M20 X 1
80M F165B 165 130 200 12X4 3.5 10 16 145 145 180 19j6 40 6 15.5 21.5 M6 305 415 M20 X 1
90S/L F165B 165 130 200 12X4 3.5 10 21 247 243 192 24j6 50 8 20 27 M8 377 517 M20 X 1
100L F215B 215 180 250 15X4 4 11 23 262 258 217 28j6 60 8 24 31 M10 439 551 M20 X 1
112M F215B 215 180 250 15X4 4 11 27 277 274 240 28j6 60 8 24 31 M10 462 588 M25 X 1
132S/M F265B 265 230 300 15X4 4 12 34 294 291 272 38k6 80 10 33 41 M12 590 749 M25 X 1
160M/L F300B 300 250 350 19X4 5 13 35 319 320 316 42k6 110 12 37 45 M16 708 877 M40 X 2
180M/L F300B 300 250 350 19X4 5 13 55 413 360 358 48k6 110 14 42.5 51.5 M16 735 924 M40 X 2
200L F350B 350 300 400 19X4 5 16 52 413 415 381 55m6 110 16 49 59 M20 825 --- M40 X 2
225S/M (2P) F400B 400 350 450 19X8 5 16 48 458 447 55m6 110 16 49 59 M20 850 --- M40 X 2
225S/M (4,6&8P) F400B 400 350 450 19X8 5 16 48 458 447 60m6 140 18 53 64 M20 882 --- M40 X 2
250M (2P) F500B 500 450 550 19X8 5 22 55 527 525 484 60m6 140 18 53 64 M20 987 --- M50 X 2
250M (4,6&8P) F500B 500 450 550 19X8 5 22 55 527 525 484 65m6 140 18 58 69 M20 937 --- M50 X 2
280S/M (2P) F500B 500 450 550 19X8 5 22 50 558 540 65m6 140 18 58 69 M20 1120 --- M50 X 2
280S/M/L (4,6&8P) F500B 500 450 550 19X8 5 22 50 558 625 75m6 140 20 67.5 79.5 M20 1045 --- M50 X 2
315S/M/L (2P) F600B 600 550 660 24X8 6 22 45 602 625 65m6 140 18 58 69 M20 1247 --- M50 X 2
315S/M/L (4,6&8P) F600B 600 550 660 24X8 6 22 45 602 625 80m6 170 22 71 85 M20 1252 --- M50 X 2

* MARKED DIMENSION IS FOR GAS GROUP IIC APPLICATION MOTOR & OTHER DIMENSIONS ARE SAME AS ABOVE.
Note : Cable Gland size may be changed according to cable size as per customer requirement.

LF-250 to LF-315 Frame

31
19.0 Dimensions of Face Mounted Flame-Proof Motors (B-14 Mounting) as per IS : 2223

LF-90 to LF-132 Frame LF-71 to LF-132 Frame LF-90 to LF-132 Frame

Table No. - 25

Frame Size Flange OM ON OP S T AD AD* OAC OD E F G GA TH L BRAKE MOTOR CG (METRIC)


No. 0.3 j6 MIN MAX MAX MAX L MAX X NO.S

63M F75C 75 60 90 M5 2.5 125 125 130 11j6 23 4 8.5 12.5 M5 250 -- M20 X 1
71M F85C 85 70 105 M6 2.5 135 135 145 14j6 30 5 11 16 M5 280 375 M20 X 1
80M F100C 100 80 120 M6 3 145 145 180 19j6 40 6 15.5 21.5 M6 305 420 M20 X 1
90S/L F115C 115 95 140 M8 3.5 247 243 192 24j6 50 8 20 27 M8 375 527 M20 X 1
100L F130C 130 110 160 M8 3.5 259 258 217 28j6 60 8 24 31 M10 435 550 M20 X 1
112M F130C 130 110 160 M8 3.5 274 274 240 28j6 60 8 24 31 M10 460 590 M25 X 1
132S/M F165C 165 130 200 M12 3.5 296 291 272 38k6 80 10 33 41 M12 588 745 M25 X 1

* MARKED DIMENSION IS FOR GAS GROUP IIC APPLICATION MOTOR & OTHER DIMENSIONS ARE SAME AS ABOVE.
Note : Cable Gland size may be changed according to cable size as per customer requirement.

32
Table No. - 26
Electrical performance figures of Flame-Proof, TEFC, Foot, Flange and Face Mounted Three Phase
At 415 V, 50Hz, Two Pole Induction Motor

Rated Output Frame Rated Rated Rated Starting Starting Peak Efficiency % Power Factor Rotor Approx.
kW HP Size Current Speed Torque Current Torque Torque GD 2 Net
Amps RPM kgm % of % of % of 100% 75% 50% 100% 75% 50% kg m sq Weight
Rated Rated Rated kg
Current Torque Torque
0.18 0.25 63 0.60 2730 0.06 400 240 310 64 62 56 0.68 0.65 0.54 0.0016 11

0.25 0.33 71 0.70 2820 0.09 430 220 320 70 68 62 0.71 0.65 0.55 0.0016 12

0.37 0.50 71 1.10 2800 0.13 490 250 320 66.1 64.1 58.1 0.71 0.65 0.59 0.0016 17

0.55 0.75 71 1.45 2800 0.19 520 230 300 69.1 64.4 60.1 0.76 0.72 0.67 0.0021 18

0.75 1.0 80 1.70 2840 0.26 600 240 320 72.1 70.1 65.1 0.85 0.79 0.73 0.0127 24

1.1 1.5 90S 2.50 2840 0.38 530 200 250 75 72 69 0.80 0.74 0.72 0.0136 45

1.5 2.0 90S 3.30 2860 0.51 580 240 300 77.2 76.2 73.2 0.81 0.78 0.72 0.0219 46

2.2 3.0 90L 4.60 2860 0.75 660 240 300 79.7 77.2 75.7 0.83 0.79 0.69 0.0246 48

3.7 5.0 100L 7.72 2880 1.25 600 220 300 82.7 80.7 75.7 0.86 0.83 0.76 0.038 59

5.5 7.5 132S 11.0 2900 1.85 650 200 250 84.7 84.7 82.2 0.84 0.83 0.75 0.159 103

7.5 10.0 132S 14.0 2900 2.52 650 200 250 86 86 86 0.88 0.83 0.74 0.185 111

9.3 12.5 160M 17.0 2900 3.13 650 210 280 87 87 83.3 0.87 0.85 0.79 0.219 122

11.0 15.0 160M 20.0 2900 3.70 650 200 300 87.6 85.6 83.6 0.87 0.82 0.76 0.30 159

15.0 20.0 160L 27.5 2920 5.01 650 220 300 88.7 85.7 83.7 0.85 0.81 0.77 0.35 177

18.5 25.0 180M 33.0 2910 6.20 680 220 300 89.3 86.8 84.8 0.87 0.85 0.77 0.39 200

22.0 30.0 200L 38.0 2940 7.30 650 230 300 89.9 89.9 86.9 0.89 0.85 0.79 0.64 250

30.0 40.0 200L 52.0 2940 9.95 620 220 300 90.7 89.7 87.7 0.88 0.86 0.80 0.87 300

37.0 50.0 225M 64.0 2900 12.44 650 200 300 91.2 90.7 89.7 0.89 0.88 0.84 0.98 --

45.0 60.0 250M 78.0 2950 14.87 550 200 300 91.7 91.2 88.2 0.91 0.90 0.89 1.05 --

55.0 75.0 280S 92.0 2965 18.09 700 210 300 92.1 91.1 90.1 0.90 0.89 0.85 1.8 --

75.0 100.0 280M 126 2965 24.70 700 190 270 92.7 92.7 91.2 0.89 0.85 0.77 6.63 --

90.0 120.0 315S 158 2970 29.65 700 190 270 93 93 91.5 0.85 0.81 0.77 8.18 --

110.0 150.0 315S 183 2970 36.11 700 180 270 93.3 93.3 91.8 0.89 0.83 0.75 11.55 --

125.0 170.0 315M 206 2970 41.04 700 180 270 93.4 93.4 91.9 0.92 0.88 0.80 12.7 --

132.0 180.0 315M 218 2970 43.33 700 180 270 93.5 93.3 92 0.90 0.86 0.78 13.89 --

160.0 215.0 315L 260 2980 52.35 700 180 270 93.8 93.8 92.3 0.91 0.89 0.87 14.3 --

200.0 270.0 315L 320 2980 65.44 700 180 270 94 94 92.5 0.92 0.87 0.88 18.87 --

33
Table No. - 27
Electrical performance figures of Flame-Proof, TEFC, Foot, Flange and Face Mounted Three Phase
At 415 V, 50Hz, Four Pole Induction Motor

Rated Output Frame Rated Rated Rated Starting Starting Peak Efficiency % Power Factor Rotor Approx.
2
kW HP Size Current Speed Torque Current Torque Torque GD Net
Amps RPM kgm % of % of % of 100% 75% 50% 100% 75% 50% kg m sq Weight
Rated Rated Rated kg
Current Torque Torque
0.12 0.16 63 0.40 1325 0.09 300 200 280 60 54 50 0.74 0.70 0.54 0.0035 11

0.18 0.25 63 0.65 1340 0.13 310 210 280 63 56 52 0.65 0.60 0.50 0.0035 12

0.25 0.33 71 0.70 1360 0.18 400 200 260 68 68 60 0.73 0.65 0.55 0.0035 18

0.37 0.50 71 1.00 1390 0.26 450 200 260 65.1 64.1 59.1 0.79 0.74 0.60 0.0035 20

0.55 0.75 80 1.40 1420 0.38 480 200 250 69.1 68.1 65.1 0.79 0.73 0.57 0.0130 24

0.75 1.0 80 1.80 1410 0.52 450 200 240 72.1 72.1 70.1 0.80 0.76 0.67 0.0140 25

1.1 1.5 90S 2.50 1400 0.77 570 200 260 75 75 69 0.81 0.73 0.61 0.059 44

1.5 2.0 90L 3.40 1410 1.04 560 190 240 77.2 77.2 74.2 0.79 0.77 0.59 0.055 46

2.2 3.0 100L 4.80 1430 1.50 590 200 250 79.7 79.7 77.7 0.80 0.79 0.66 0.045 57

3.0 4.0 100L 6.40 1410 2.07 590 200 250 81.5 81.5 79.5 0.80 0.80 0.70 0.054 62

3.7 5.0 112M 7.70 1440 2.51 580 200 250 82.7 82.7 80.7 0.80 0.80 0.65 0.084 77

5.5 7.5 132S 11.0 1440 3.72 630 200 260 84.7 84.7 83.7 0.82 0.80 0.67 0.170 108

7.5 10.0 132M 14.5 1450 5.04 650 200 250 86 86 85 0.84 0.82 0.65 0.20 115

9.3 12.5 132M 20.0 1450 6.25 650 190 280 87.3 87.3 86.3 0.74 0.71 0.64 0.22 125

9.3 12.5 160M 18.5 1450 6.25 620 200 250 88.3 88.2 87.3 0.79 0.78 0.69 0.38 148

11.0 15.0 160M 22.0 1460 7.45 600 200 250 87.6 86.6 85.6 0.79 0.79 0.73 0.42 155

15.0 20.0 160L 28.5 1460 10.02 600 250 270 88.7 87.7 87.7 0.81 0.81 0.74 0.53 174

18.5 25.0 180M 34.0 1460 12.35 600 250 270 89.3 88.3 87.3 0.84 0.77 0.60 0.87 250

22.0 30.0 180L 40.0 1460 14.69 600 250 270 89.9 89.9 88.9 0.85 0.82 0.78 1.06 260

30.0 40.0 200L 54.0 1465 19.97 600 250 270 90.7 90.7 89.7 0.85 0.83 0.78 1.42 325

37.0 50.0 225S 67.0 1470 24.54 600 230 280 91.2 91.2 90.2 0.85 0.84 0.78 1.60 460

45.0 60.0 225M 79.0 1470 29.85 600 230 280 91.7 90.7 90.7 0.87 0.86 0.79 1.85 480

55 75 250M 96 1475 36.36 650 250 280 92.1 92.1 91.1 0.86 0.85 0.78 3.20 570

75 100 280S 131 1480 49.41 650 250 280 92.7 92.2 91.2 0.85 0.83 0.81 7.21 750

90 120 280M 156 1480 59.29 650 250 280 93 92.5 91.5 0.85 0.83 0.80 8.25 800

110 150 315S 191 1485 72.08 650 225 255 93.3 93.3 90.8 0.84 0.82 0.80 11.62 --

125 170 315M 215 1485 81.91 650 225 255 93.4 93.4 90.9 0.86 0.84 0.82 12.8 --

132 180 315M 227 1485 86.49 650 225 255 93.5 93 92.5 0.87 0.85 0.83 13.98 --

160 215 315L 271 1485 105.05 650 250 280 93.8 93.5 92.5 0.87 0.83 0.75 27.88 --

180 250 315L 314 1485 118.34 650 240 270 94 94 92.7 0.85 0.81 0.73 29.30 --

200 270 315L 339 1485 131.31 650 250 280 94 94 92.5 0.87 0.82 0.75 30.74 --

34
Table No. - 28
Electrical performance figures of Flame-Proof, TEFC, Foot, Flange and Face Mounted Three Phase
At 415 V, 50Hz, Six Pole Induction Motor

Rated Output Frame Rated Rated Rated Starting Starting Peak Efficiency % Power Factor Rotor Approx.
kW HP Size Current Speed Torque Current Torque Torque GD 2 Net
Amps RPM kgm % of % of % of 100% 75% 50% 100% 75% 50% kg m sq Weight
Rated Rated Rated kg
Current Torque Torque
0.18 0.25 71 0.70 900 0.27 370 190 240 60 56 50 0.65 0.58 0.48 0.0044 18

0.25 0.33 71 1.00 890 0.36 340 190 240 60 58 50 0.60 0.58 0.52 0.0044 20

0.37 0.50 80 1.40 900 0.40 320 190 250 63 63 62 0.58 0.55 0.51 0.0123 24

0.55 0.75 80 1.80 900 0.60 320 190 260 67 66 63 0.63 0.58 0.54 0.0146 25

0.75 1.0 90S 2.10 950 0.77 400 200 280 70 69 89 0.70 0.64 0.57 0.028 46

1.1 1.5 90L 3.00 940 1.14 400 200 280 72.9 68.9 66.9 0.70 0.60 0.52 0.032 48

1.5 2.0 100L 3.70 930 1.57 400 190 290 75.2 72.2 66.2 0.75 0.67 0.59 0.048 56

2.2 3.0 112M 5.20 945 2.27 400 190 250 77.7 77.7 76.7 0.74 0.68 0.62 0.098 79

3.7 5.0 132S 8.00 960 3.76 450 190 250 80.9 80.9 79.9 0.79 0.75 0.69 0.21 107

5.5 7.5 132M 12.0 950 5.64 540 230 280 83.1 83.1 82.1 0.76 0.76 0.72 0.25 115

7.5 10.0 160M 15.5 960 7.62 600 200 250 84.7 84.7 83.7 0.79 0.73 0.64 0.56 158

9.3 12.5 160L 19.0 960 9.45 650 220 250 87 87 86 0.78 0.74 0.62 0.71 173

11.0 15.0 160L 21.0 970 11.06 650 220 300 86.4 86.4 85.7 0.84 0.75 0.62 0.78 183

15.0 20.0 180L 28.0 960 15.23 650 230 300 87.7 87.7 86.7 0.84 0.81 0.71 1.24 310

18.5 25.0 200L 34.0 980 18.41 600 230 300 88.6 88.6 87.6 0.84 0.79 0.73 1.66 --

22.0 30.0 200L 41.0 980 21.89 620 230 280 89.2 89.2 88.2 0.82 0.78 0.72 1.79 --

30.0 40.0 225M 55.0 980 29.85 600 210 250 90.2 90.2 89.2 0.84 0.80 0.79 2.40 --

37 50 250M 67 980 36.81 600 210 250 90.8 90.3 89.3 0.84 0.80 0.74 3.60 --

45 60 280S 80 980 44.77 600 230 260 91.4 91.4 89.4 0.85 0.82 0.73 8.01 --

55 75 280M 97 980 54.72 650 200 230 91.9 91.4 90.9 0.85 0.81 0.73 9.89 --

75 100 315S 131 985 74.62 650 225 255 92.6 92.1 91.1 0.86 0.82 0.74 14.12 --

90 120 315M 157 985 98.09 650 225 255 92.9 92.4 91.7 0.85 0.81 0.73 17.0 --

110 150 315M 191 985 108.88 650 225 255 93.3 93.3 92.3 0.86 0.82 0.70 18.98 --

132 180 315L 229 985 130.66 650 230 280 93.5 93.5 92.5 0.87 0.83 0.75 29.94 --

160 215 315L 276 985 157.58 650 210 260 94.5 94.5 93.5 0.85 0.81 0.73 29.94 --

35
Roller Table Motors

Table No. - 29
Electrical performance figures of Flame-Proof, TEFC, Foot, Flange and Face Mounted Three Phase
At 415 V, 50Hz, Eight Pole Induction Motor

Rated Output Frame Rated Rated Rated Starting Starting Peak Efficiency % Power Factor Rotor Approx.
kW HP Size Current Speed Torque Current Torque Torque GD 2 Net
Amps RPM kgm % of % of % of 100% 75% 50% 100% 75% 50% kg m sq Weight
Rated Rated Rated kg
Current Torque Torque
0.18 0.25 80 1.00 616 0.27 200 180 240 49 47 43 0.50 0.47 0.42 0.0143 25

0.25 0.33 80 1.20 680 0.36 250 180 250 55 51 47 0.52 0.50 0.44 0.0143 26

0.37 0.50 90S 1.40 680 0.53 300 170 250 61 59 59 0.63 0.54 0.50 0.0283 45

0.55 0.75 90L 2.10 700 0.77 400 190 250 65 63 61 0.63 0.55 0.50 0.0322 48

0.75 1.0 100L 2.50 700 1.04 400 190 250 71 69 64 0.65 0.62 0.54 0.049 56

1.1 1.5 100L 3.30 710 1.51 400 190 250 73 73 71 0.68 0.62 0.54 0.058 60

1.5 2.0 112M 4.00 710 2.06 400 190 250 77 75 71 0.69 0.62 0.54 0.093 77

2.2 3.0 132S 5.40 710 3.02 450 200 260 81 80 78 0.70 0.68 0.60 0.20 110

3.7 5.0 132M 10.00 720 5.01 500 200 260 81 79 77 0.66 0.62 0.56 0.28 120

3.7 5.0 160M 8.20 720 5.01 500 200 260 83 82 81 0.75 0.70 0.64 0.50 146

5.5 7.5 160M 12.50 720 7.45 500 200 240 86 85 83 0.73 0.70 0.62 0.58 155

7.5 10.0 160L 16.00 720 10.16 500 210 280 87 85 83 0.74 0.70 0.63 0.70 165

11.0 15.0 180M 23.00 735 14.59 500 210 290 89 88 86 0.77 0.72 0.68 1.51 180

15.0 20.0 200L 32.00 735 19.90 500 210 290 89 88 87 0.76 0.72 0.67 1.93 265

18.5 25.0 225S 37.00 735 24.5 500 200 260 89 88 87 0.79 0.78 0.74 2.30 300

22.0 30.0 225M 43.00 735 29.18 500 200 260 89 88 87 0.80 0.78 0.74 2.60 325

30.0 40.0 250M 57.00 735 39.80 500 200 260 91 90 89 0.80 0.78 0.74 4.40 400

37.0 50.0 280S 75.00 735 49.08 500 210 240 91.5 91.5 89.5 0.75 0.71 0.63 8.01 600

45.0 60.0 280M 91.00 740 59.29 500 210 240 92 92 90.5 0.75 0.71 0.63 9.89 630

55.0 75.0 315S 106.00 740 72.47 600 200 230 92.5 92.5 91 0.78 0.74 0.66 14.12 1300

75.0 100.0 315M 144.00 740 98.82 600 200 230 93 93 91.5 0.78 0.74 0.66 18.98 1450

90.0 120.0 315L 171.00 740 118.58 600 250 280 94 94 92 0.78 0.74 0.66 29.94 1600

110.0 150.0 315L 209.00 740 144.93 600 250 280 94 94 92.5 0.78 0.74 0.66 29.94 1700

132.0 180.0 315L 250.00 740 173.92 600 250 280 94.5 94.5 92.5 0.78 0.74 0.66 33.28 1850

Range Torque : 1Kgm - 35.5kgm


Roller Table Motors
Pole 4/6/8
LHP Roller Table Motors are designed taking into consideration the
experience of users in steel plants over the years. Mounting Standard / Special as per IPSS

Applications specifications
In steel plants for conveying steel billets for Frame Upto 355L
processing through roller mills Voltage 415V AC or (upto 660V)
Suitable for Geared Motors operating with VVVF source Frequency 50Hz
Applicable Standards Stalled rotor Up to 15 minutes max or as per
IPSS - 1-03-007 Inter plant standard for steel industries withstand time customer requirement
Insulation H Class
IPSS - 325 (IEC 34-1) Specifications for 3 phase induction motors
Duty S3, S4, S1,S5,S6 & S7
Degrees of protection provided by enclosure for
IPSS -4691 (IEC 34-5) rotating electrical machinery Frame with circular fines disign

36
Non-Sparking Motors (Ex 'nA')

Design and constructional features :


No. Parameters Standard Features Optional Features

1 Construction : Motor Frame, End The components of these motors are made of cast Iron Aluminum having The components fabricated from steel

Shields, Flanges, Bearing cover sufficient strength and dimensional stability. with necessary re-inforcement

Motors are designed with F class insulation & temp. rise is limited to the H class but temp. rise will be limited to B, F class

values specified in IS/IEC 600 79-15 Windings are impregnated with with special insulating varnish/ impregnating

2 Winding insulating varnish & baked. Overhang of the winding is treated with epoxy resign with tropical & fungicidal treatment

gel coat to give mechanical, electrical and thermal stability and strength

3 Rotor Rotors are made of die cast Aluminum with squirrel cage construction Copper die cast of brazed rotors

4 Output Rating / Poles Please refer to table - 1 -

5 Eye bolts Eye bolts are made of forged steel S.S. / Alloy steel

6 Shaft Shafts are made of carbon steel (40C8 grade IS 2073 / EN-8 BS : 970) Shaft with other material like S.S. / Alloy steel etc.

7 Shaft extension Motors are supplied with standard extension on drive end as per Motors with both side extension / special extension.

IS : 1231 / IS : 2223 (Pls refer table 3,4,5)

8 Terminal box Assembly Terminal box & cover are made of cast iron Aluminum Fabricated from steel.

T. Box can be rotated through 360 in steps of 90 . positions like LH. & RH. & Top.

Clearance & creepage distances are maintained as per IS / IEC : 60079-15

& IS : 6381. Terminal studs & its accessories are made from brass / s.s. and -

are nicket plated. Terminal blocks are made from DMC / Epoxy or HD T. studs & its accessories in special material

Compressed type-II of IS : 3513 Part-I or P-120 grade Bakelite & are

non-hygroscopic. Cable lugs of terminal connections are anti-loosening T. blocks in porcelain or special insulating material.

& are non-loosening & anti-vibration type.


9 Cable Entry Standard entry with 3/4" B.S.C. 01 no up to 132 frame Other entries in metric & PG type threads with other

Std. Entry with Standard entry with 1" B.S.C. -02 no 160 to 180 frame entry sizes/nos. The clearance & creepage distances

3/4" BSC for 132 fr. Standard entry with 2" B.S.C. -01 no 200 to 355 frame
10 Dimensions Mounting dimensions of motor frame, flangers & shafts are as per Special dimensions with special flanges/frames.

IS : 1231 / IS : 2223 (Pl. Refer Table 3,4,5)


11 Bearings Motors are designed with single row double shielded deep groove ball Motors with other type of bearings (angular contact

bearings and are pre-greased with high temp. grease for life up to 225 ball bearings, cylindrical/taper roller bearing etc.)

frame. For 250 to 315 frame bearing are provided with greasing Motors with online greasing arrangement.

arrangement Bearing life is 40,000 Hrs.

Motors are offered with foot mounting, flange mounting with B type flange Motors with special foot/flange for horizontal

12 Mounting & Mounting & flange mounting with C type flange mounting. Motors are suitable for & vertical mounting

Position horizontal (B3, B5, B6, B7, B8) & vertical (V1, V3, V5, V6, V18, V19) mounting

position as per IS : 2253


13 Fan Fan is made from Cast iron / M. S.
14 Fan cover Fan cover is made of M.S. sheet metal pressed / welded. Made from fabricated steel, S.S.

15 Supply voltage & frequency Motors are designed for 415V 10% with 50HZ 5% supply Other on request upto 660V

16 Performance Performance of motors as per IS : 325 Special requirement if any.

17 Duty S1 (continuous) Other duties - S1 to S9

18 Method of Starting Motor up to 5 HP are suitable to DOL starting Motors above

5 HP are suitable for Star Delta connection


19 Method of Cooling Standard motors are Totally Enclosed Fan Cooled (TEFC) Totally Enclosed Naturally Cooled (TENC) / Air Over

Motors (AOM) or forced cooled with auxiliary blower

37
No. Parameters Standard Features Optional Features

20 Surface Temp. The surface temp. is limited to Lan T3 Temp clan (200 C) Other temp. class on request.

(Temp. calss T3) under normal operating condition to prevent

thermal ignition in surrounding explosive atmosphere.


21 Noise & Vibration Motors are with noise level maintained as per IS : 12065 & vibration Motors with low noise level & precision

level of normal class as per IS : 12075. class of vibration.


22 Protection IP : 55 for Motor enclosure & T. Box Superior protection as per IS : 4691.
23 Environment Condition Amb. Temp.: 50 C, Any special environment condition.

Relative Humidity : 95% max.


24 Space heater On request. Space heater & Thermistor provided with

separate T Box for connection


25 Hardware All hardware (fasteners0 are Zinc plated to prevent Special hardware with special

from corrosion. Material, grade, type & plating.


26 Drain hole Drain hole with plug screw on end shields to remove condensate -

water for motor 180 & above frames.


27 Paint Motors are painted with one coat of primer followed Motors with special paint & shade.

by two coasts of anti-corrosive paint.

Specifications Non-sparking (Type-'nA')

1 Output Range : 0.12/315 kW (0.16/425 HP) Pole-wise frame sizes


2 Poles : 2,4,6 & 8 Output
(kW/HP) 2 Pole 4 Pole 6 Pole 8 Pole 2 Pole 4 Pole 6 Pole 8 Pole
3 Standard Specifications
0.12/0.16 71 71 71 - 63 63 71 71
Voltage : 415 V 10% 0.18/0.25 71 71 71 80 63 63 71 80
Frequency : 50 Hz 5% 0.25/0.33 71 71 71 80 63 71 71 80
Phase : 3 0.37/0.50 71 71 80 90S 71 71 80 90S
0.55/0.75 71 80 80 90L 71 80 80 90L
Insulation Class : F 0.75/1.00 80 80 90S 100L 80 80 90S 100L
Mounting : Foot, Flange & face mounted 1.10/1.50 80 90S 90L 100L 80 90S 90L 100L
1.50/2.00 90S 90L 100L 112M 90S 90L 100L 112M
Ambient Temp. : 40 C
2.20/3.00 90L 100L 112M 132S 90L 100L 112M 132S
3.70/5.0 100L 112M 132S 160M 100L 112M 132S 160M
Protection : IP-55 5.50/7.50 132S 132S 132M 160M 132S 132S 132M 160M
7.50/10.00 132S 132M 160M 160L 132S 132M 160M 160L
Duty : S1 9.30/12.50 132M 160M 160L 180M 132M 160M 160L 180M
Method of cooling : TEFC 11.00/15.00 160M 160M 160L 180L 160M 160M 160L 180L
Mounting position : B3, B5, B14, B34, B35 15.00/20.00 160M 160L 200L 200L 160M 160L 200L 200L
18.50/25.00 160L 180M 200L 225S 160L 180M 200L 225S
V1, V3, V5, V6, V18 & V19 22 / 30 180L 180L 225M 225M 180L 180L 225M 225M
Dimensions : As per IS: 1231/IS-2223 30 / 40 200L 200L 225M 250M 200L 200L 225M 250M
37 / 50 225S 225S 250M 280S 200L 225S 250M 280S
Performance : As per IS-325, IS/IEC 60079-15
45 / 60 250M 225M 280S 280M 225M 225M 280S 280M
Reference Standards : IS/IEC 60079-15 (Ex 'nA') 55 / 75 250M 250M 280M 315S 250M 250M 280M 315S
75 / 100 280S 280S 315S 315S 280S 280S 315S 315S
90 /120 280M 280M 315M 315M 280M 280M 315M 315M
Certification : Tested by ERTL Kolkata
110 / 150 315S 315S 315M 315M 315S 315S 315M 315M
Approved by PESO, Nagpur 125 / 170 315M 315M - - 315M 315M - -
Application : Suitable for zone-2 132 / 180 315M 315M 315L 315L 315M 315M 315L 315L
160 / 215 315L 315L 315L 315L 315L 315L 315L 315L
classification of 180 / 250 315L 315L - - 315L 315L - 355L
hazardous area 200 / 270 315L 315L - - 315L 315L 355L 355L
235/300 355L 355L 355L -
250/335 355L 355L 355L -
315/425 355L 355L - -

38
20.00 Tolerance on Performance Values & Dimensions

The electrical performance data (for Standard, Crane & Flame-Pfoof motors) namely current, power factor, efficiency, full load speed
and torque at full load, starting torque & pull out torque are given in the table, These values are subjected to the following tolerances
Beside these, values are given for information & guidance.

Electrical Parameters

i. Efficiency (n) :
a) By summation of losses :
Motors up to 50 kW -15 percent of (1-n)
Motors above 50 kW -10 percent of (1-n)
b) By input-Output test -15 percent of (1-n)
ii. Total losses applicable to motors above 50 kW* + 10 percent of the total losses
iii. Power factor (Cos O) -1/6 of (1 Cos O) Min. 0.02 and Max. 0.07
iv. Slip at full load and at working temperature + 20 percent of the guaranteed slip
v. Breakaway starting current of squirrel cage + 20 percent of the guaranteed starting current (no negative tolerance)
Induction motors with short-circuit rotor and
with any specified starting apparatus.
vi. Breakaway torque - 15 percent to + 25 percent of the guaranteed torque (+ 25 percent
may be exceeded by agreement)
vii. Pull out toque -10 percent of the guaranteed torque except that after allowing for this
tolerance, the torque shall be not less than 1.6 or 1.5 times the rated torque

Mechanical Parameters

Dimensions Talerance
Flame size H > 250 0, -0.5 mm
< 355 0, -1 mm
Diameter O of shaft exiension :
(i) 11 to 28 mm j6
(ii) 32 to 48 mm k6
(iii) 55 mm and over m6
Diameter N of Flange spigot : j6 up to F 740 B
Key with h9
Width of drive shaft keyway (normal keying) N9
Key depth :
(i) Square section h9
(ii) Rectangular section h1 1

39
Table No. - 30
Diameter of shaft extension run out of motoers

Over Up to Normal Precision Class


0 10 0.030 0.015

10 18 0.035 0.018

18 30 0.040 0.021

30 50 0.050 0.025

50 80 0.060 0.030

80 120 0.070 0.035

Concentricity of spigot diameter and perpendicularily of mounting surface of flange with respect to shaft
Flange No. Spigot Dia. Normal Class Precision Class
F65 50 0.080 0.040

F75 60 0.080 0.040

F85 70 0.080 0.040

F100 80 0.080 0.040

0115 95 0.080 0.040

F130 110 0.100 0.050

F165 130 0.100 0.050

F215 180 0.100 0.050

F265 230 0.100 0.050

F300 250 0.125 0.063

F350 300 0.125 0.063

F400 350 0.125 0.063

F500 450 0.125 0.063

F600 550 0.160 0.080

40
Shipping Specifications

Table No. - 31
For Three Phase Standard Induction Motors

Fame Size Type of Packing Net Weight in kg (Max.) Gross Weight in kg (Max.) L x B x HT. in mm (Max.)
63 Thermocole (EPS) 8.5 10 245 x 180 x 195

71 Thermocole (EPS) 8.5 12.5 280 x 195 x 220

80 Thermocole (EPS) 18 20 230 x 250 x 250

90 Thermocole (EPS) 28 30 425 x 250 x 305

100 Thermocole (EPS) 40 58 480 x 320 x 295

112 Thermocole (EPS) 50 68 650 x 395 x 480

132 Wooden Box 80 106 700 x 495 x 495

160 Wooden Box 133 173 875 x 650 x 610

180 Wooden Box 174 214 875 x 650 x 610

200225 Wooden Box 280 330 940 x 790 x 790

250 Wooden Box 325 385 1170 x 920 x 920

280 Wooden Box 770 1150 1320 x 970 x 970

315 Wooden Box 1500 1950 1475 x 965 x 1095

355 Wooden Box 2050 2500 2020 x 1225 x 1310

Brake Motors
63 Wooden Box 13 15 425 x 250 x 305

71 17 19 425 x 250 x 305

80 Corrugated 25 40 425 x 250 x 305

90 Corrugated 42 60 570 x 355 x 420

100 Corrugated 50 70 650 x 395 x 480

112 Wooden Box 60 90 700 x 495 x 585

132 Wooden Box 100 125 800 x 520 x 535

160 Wooden Box 150 200 875 x 650 x 610

180 Wooden Box 200 250 940 x 790 x 790

Flame - Proof Motors

80 Wooden Box 35 45 580 x 355 x 420

90 Wooden Box 45 60 650 x 395 x 480

100 Wooden Box 60 80 650 x 395 x 480

112 Wooden Box 80 100 700 x 495 x 585

132 Wooden Box 100 125 700 x 495 x 585

160 Wooden Box 150 200 940 x 790 x 790

180 Wooden Box 225 275 940 x 790 x 790

200 Wooden Box 250 300 940 x 790 x 790

225 Wooden Box 290 350 1070 x 940 x 790

250 Wooden Box 350 400 1475 x 965 x 1095

280 Wooden Box 950 1200 1475 x 965 x 1095

315 Wooden Box 1600 2000 1475 x 965 x 1095

41
Information required along with Purchase Order / Enquiry

Certain information is necessary to offer the right type of motor for desired application. The necessary information to be funished
along with Enquiry / Purchase Order is as follows.

Standard / Crane and Hoist Duty Motors

01. Name of Customer :


02. Address :
03. Output / kW :
04. Speed :
05. Frame Size :
06. Construction :
07. Application :
08. Type of duty & Frequency :
09 Method of Cooling :
10. Supply Voltage & Frequency :
11. Amb. Temp. & Type of protection required :
12. No. of starts / stops per hour with duty & CDF :
13. Load Torque :
14. Duty cycle if other than those given in diagram :
15. Any specified requirement - related to
Amb. Temp., Starting Current & Torque :

Additional information for Brake Motors

01. Brake Type :


Brake Size :
02.
Coil Operating Voltage :
03.
Hub Bore :
04. Whether rectifier is required :

05. (All other information similar to standard motors):


Additional information for Flame-Proof Motors / Increased Safety / Non-Sparking motors
Gas group I, IIA or IIB :
Application for which motors are used :
01. Classification of Hazardous area :
Load GD2 :
02.
Cable Arrangements :
03.
Compression Gland Size / Type :
04. No. of cable entries :

05. Whether sealing box is required :


(All other relevant information similar to standard motors) :

Note : You are requested to fill in a photo-copy of the enquiry form and send it to us.