Вы находитесь на странице: 1из 1

500

100
300
400

900

300
1:8
1:5
PCC 300
M - 20
4 NO.
6190

6190
300 300 359 300 @ 100 C/C
300
900 500 560 1500 1197 700 1500

300
500 900

500 900
3460 3756 @ 130 C/C
@ 130 C/C
FDN. LVL. 144.815

4060 4356
700
200 mm Levelling
RETURN SECTION course M-15
ABUTMENT SECTION DETAILS OF ABUTMENT
CAP WITH DIRT WALL

4180 4180 NOTE :- Bed concrete outer line not shown in plan.

NOTES :-
300 300 300 300
1500 610 500 970 8460 970 500 610 1500
1. PROPER COMPACTION OF CONCRETE SHOULD BE DONE
2703

4500
204200

WITH VIBRATORS.

20
300

2. PROPERLY BRACED STEEL PLATES SHALL BE USED FOR


SHUTTERING.
3. WEARING COAT SHALL NOT BE LAID MONOLITHIC WITH THE
1197

DECK SLAB. THE THICKNESS OF R.C.C WEARING COAT


DIRT WALL
SHOULD BE 75 MM.
4. GRADE OF CONCRETE TO BE USED -
700

2410 A) FOR ABUTMENT& RETURN WALL M-20.


B) FOR ABUTMENT CAP & DIRT WALL M-25.
359

C) FOR DECK SLAB M-25 AS PER M.O.S.T. STANDARD.


4356
2859

5. ALL REINFORCING BARS SHALL BE HYSD BARS


1500

CONFORMING TO IS:1786 GRADE Fe 500.


6. CLEAR COVER TO ANY REINFORCEMENT
A) BASE RAFT - 75 MM
300

B) ALL OTHER COMPONENTS - 40 MM


12000 7. LAPPING SHOULD BE STAGGERED AND NOT MORE THAN
50% OF BAR SHOULD BE LAPPED AT A SECTION. LAP
PLAN OF ABUTMENT & RETURN LENGTH LENGTH SHOULD BE 76 TIMES DIA. OF BAR.
8. ANNULAR SPACE AROUND FOOTING UP TO TOP OF HARD
ROCK LEVEL IS FILLED BY M-15.

CLIENT :-
AMARWADA - RAMGARH ROAD
Executive Engineer M/s RAJARAM CONSTRUCTION
ISSUED ON 04-01-2020
MP PWD Division WORKING DRAWING OF ABUTMENT &
CHHINDWARA APPD : REVISION - RETURN WALL CH.- 4+541
SAWYTECH ENGINEERING SERVICES
Scale : NTS DRAWN BY A.A.R Dwg No. : MPPWDC / AR / 02 SUB ENG. SUB DIV. OFFICER EXECUTIVE ENG.

Вам также может понравиться