Cross Flow
Induced Draft
Trust MESAN With
Your Evaporative Cooling Needs
Overview
The new MXH series is the most versatile one in our The MXH series is available in 33 box
product line up. It includes many different configurations sizes with 248 models in capacities
to fit multiple and varied applications like low profile ranging from 107 to 1,667 tons.
units, containerized towers, modular units, energy saving
models, space saving towers, which give the customer
the opportunity to choose the tower that better adapts to
C26F-12R02
their particular project, and all this with the high quality
C26H-12R01
CC2266CJ--01 86 R 0 8
0
Model Designation
Box Size Number
(It relates to footprint Numbers of Cells,
dimensions in meters) Fan Motor Power
eg. 2 cells per set
CTI STD-201
Certified Line
MXH 2252A 5.5/V S4 2
V - Velocity Recovery Stack F4 - for SS304 Casing & Structure
Q - Super Low Noise Fan F6 - for SS316 Casing & Structure
E - Drift Eliminator S4 - for FRP Casing & SS304 Structure
A - Louver S6 - for FRP Casing & SS316 Structure
G - for HDGS Casing & Structure
1
Advantages
Low Maintenance
Motors and drive components are located below the fan blades, with easy access from service
platform. Nozzle-free water distribution system. Sealed bearings rated for L10-80,000 hours ensure a
trouble-free, almost maintenance free, service life.
2
MXH SERIES
Tower Structure
01 Fan Guard
02 V-Belt Reducer 01 02 03 04 05
03 Motor
04 Fan
06 11
05 Fan Cylinder
06 Optional Handrails &
12
Safety Cage
07 Service Platform
08 Optional Drift Eliminator 13
07
09 Internal Walkway
10 Cold Water Basin 14
11 Water Inlet 15
08
12 Hot Water Basin
16
13 Motor Support
14 Structure 09
15 Access Door
10 17
16 Infill
17 Casing
Mechanical Components
Motor
TEAO type, IP55 enclosure, class F insulation, high efficiency, and
specially designed to operate within the high-humidity environment of a
cooling tower. IP65 motors are also available as an option.
Axial Fan
High efficiency, axial, aluminum alloy fans, with innovative low drag,
aerodynamic airfoil blade design, adjustable pitch blades and low-noise.
3
Casing and Structure
SS-304 or SS-316 stainless steel construction are also available for the
highest corrosion resistance.
Water Distribution
Infill
High efficiency infill, maximizes the contact surface between water and air, allowing for higher
evaporation rates and air flow, for reduced air pressure drop and lowest energy consumption.
Another feature of MESAN's infill is the built-in primary drift eliminators, that when coupled with the
optional secondary drift eliminators provide the lowest possible drift losses.
Factory Assembled
4
MXH SERIES
Product Technical Data
Models: 1739-3061C
Motor Nominal Dimensions
Model
kW Tons L(mm) W(mm) H(mm)
4 214
5.5 238
7.5 264
2753 11 300 2,780 5,300 3,725
15 333
18.5 357
22 378
4 191
5.5 211
7.5 235
2758A 11 266 2,780 5,880 3,275
15 295
18.5 316
22 335
4 222
5.5 247
Motor Nominal Dimensions 7.5 272
Model
kW Tons L(mm) W(mm) H(mm) 2758B 11 308 2,780 5,880 3,775
2.2 107 15 342
3 119 18.5 365
4 131 22 387
1739 1,740 3,920 3,725 4 251
5.5 145
7.5 161 5.5 279
11 183 7.5 308
2.2 123 2758C 11 349 2,780 5,880 4,275
3 137 15 387
4 151 18.5 414
2041 2,010 4,190 3,725
5.5 167 22 439
7.5 185 4 210
11 211
5.5 233
3 164
7.5 257
4 181
2244 5.5 201 2,280 4,470 3,725
3061A 11 292 3,040 6,110 3,275
7.5 223 15 323
11 253 18.5 346
3 142 22 365
4 156 4 247
2252A 5.5 172 2,280 5,210 3,225 5.5 273
7.5 191 7.5 302
11 216 3061B 11 343 3,040 6,110 3,775
3 173 15 380
4 192 18.5 407
2252B 5.5 213 2,280 5,210 3,725 22 432
7.5 236
4 285
11 267
5.5 316
3 179
7.5 349
4 197
5.5 219 11 396
3061C 3,040 6,110 4,325
2749 7.5 243 2,780 4,960 3,725 15 439
11 276 18.5 468
15 306 22 496
18.5 328 30 549
1 Nominal cooling capacity represents 35℃ EWT, 29.4℃ LWT with 25.6℃ WBT and 0.681m3/h per ton.
2 Optional velocity recovery cylinder (add suffix/ V) will increase the capacity by 2% to 7%, see selection table at www.mesanct.com for specified
capacity of each available configuration.
5 3 Satisfactory performance is based on precise selection, proper system design and installation in a clean and well-ventilated location.
Product Technical Data
Models: 3668A-4273B
Motor Nominal Dimensions
Model
kW Tons L(mm) W(mm) H(mm)
7.5 484
11 549
15 608
18.5 652
3668E 3,660 6,860 5,385
22 690
30 763
37 818
45 872
7.5 520
11 590
15 653
18.5 700
3668F 3,660 6,860 5,885
22 741
30 820
37 879
45 939
7.5 536
11 609
15 675
18.5 724
Motor Nominal Dimensions 3668G 22 767 3,660 6,860 6,385
Model
kW Tons L(mm) W(mm) H(mm) 30 850
7.5 295 37 912
11 336 45 973
15 371 55 1,041
3668A 18.5 398 3,660 6,860 3,375
7.5 592
22 420
30 465 11 672
37 499 15 745
7.5 351 18.5 799
11 398 3668H 22 847 3,660 6,860 7,435
15 440 30 939
18.5 471 37 1,007
3668B 3,660 6,860 3,875
22 499
45 1,075
30 552
37 592 55 1,149
45 631 11 436
7.5 399 15 483
11 452 18.5 517
15 501 4273A 22 547 4,270 7,310 3,875
18.5 536 30 606
3668C 3,660 6,860 4,375
22 567
37 650
30 627
37 672 45 693
45 716 11 498
7.5 442 15 550
11 501 18.5 590
15 555 22 624
18.5 594 4273B 4,270 7,310 4,375
3668D 3,660 6,860 4,885 30 691
22 628
30 697 37 741
37 747 45 791
45 790 55 845
1 Nominal cooling capacity represents 35℃ EWT, 29.4℃ LWT with 25.6℃ WBT and 0.681m3/h per ton.
2 Optional velocity recovery cylinder (add suffix/ V) will increase the capacity by 2% to 7%, see selection table at www.mesanct.com for specified
capacity of each available configuration.
3 Satisfactory performance is based on precise selection, proper system design and installation in a clean and well-ventilated location. 6
MXH SERIES
Product Technical Data
Models: 4273C-5182E
Piping
Model WI WO Overflow Drain M-U Model WI WO Overflow Drain M-U
1739 DN125×2 DN150 DN50 DN40 DN20 3668E DN150×4 DN300 DN100 DN100 DN50
2041 DN125×2 DN150 DN50 DN40 DN20 3668F DN150×4 DN300 DN100 DN100 DN50
2244 DN150×2 DN200 DN50 DN40 DN20 3668G DN150×4 DN300 DN100 DN100 DN50
2252A DN125×2 DN150 DN50 DN40 DN20 3668H DN200×4 DN350 DN100 DN100 DN50
2252B DN150×2 DN200 DN50 DN40 DN20 4273A DN150×4 DN300 DN100 DN100 DN50
2749 DN150×2 DN200 DN50 DN40 DN20
4273B DN150×4 DN300 DN100 DN100 DN50
2753 DN150×2 DN200 DN80 DN40 DN20
4273C DN150×4 DN300 DN100 DN100 DN50
2758A DN150×2 DN200 DN50 DN40 DN20
4273D DN200×4 DN350 DN100 DN100 DN50
2758B DN150×2 DN200 DN80 DN40 DN20
4273E DN200×4 DN350 DN100 DN100 DN50
2758C DN200×2 DN250 DN80 DN40 DN20
4273F DN200×4 DN350 DN100 DN100 DN50
3061A DN200×2 DN250 DN80 DN50 DN40
4273G DN200×4 DN350 DN100 DN100 DN50
3061B DN200×2 DN250 DN80 DN50 DN40
5182A DN200×4 DN350 DN100 DN100 DN50
3061C DN200×2 DN250 DN80 DN50 DN40
3668A DN125×4 DN250 DN80 DN50 DN40 5182B DN200×4 DN350 DN100 DN100 DN50
3668B DN125×4 DN250 DN80 DN50 DN40 5182C DN200×4 DN350 DN100 DN100 DN50
3668C DN125×4 DN250 DN80 DN50 DN40 5182D DN200×4 DN350 DN100 DN100 DN50
3668D DN150×4 DN300 DN80 DN50 DN40 5182E DN250×4 DN400 DN100 DN100 DN50 8
MXH SERIES
Mesan offers pre-installed basin sweeping piping system for our cooling towers to work with VAFTM
filtration system to minimize legionella contamination in building water systems and make water
treatment more effective.
(XTM System)
9
MESAN guarantees the thermal performance of its CTI certified products. All CTI
models are fully compliant with ASHRAE 90.1. Cooling Technology Institute (CTI)
is dedicated to promoting truthful rating of cooling tower capacity, by providing a
third party independent verification and periodic monitoring of the products thermal
efficiency. Having CTI certified products eliminates the need for costly onsite field
test and ensures that the system performance will meet the design objectives, for
the benefit of the building owners, operators and public.
10