Академический Документы
Профессиональный Документы
Культура Документы
2015-9-30
Zhang Hualong
Contents
3 Engineering scenarios
4 Output Documents
Internal use only▲
Engineering Scope
ZTE MTS
TSSR
MTS Cell Data certificate
and sign
Cell Data
confirmed
Information
Cell data TSSR and collection
ZTE Check and
Connection
drawing check
evaluate and approve
Diagram End
BOM output
TSSR and
Subcon drawing
output
Site information
Cell data
TSSR and Form
Output Doc. drawing
Connection BOM
Diagram
3 Engineering scenarios
4 Output Documents
Internal use only▲
SA
CC
Board Description
CC Control and Clock Module
FS Fabric Switch Module
PM Power Module
SA Site Alarm Module
FAN Fan Module
UPBG Universal Baseband Processing for GSM
BPK Baseband Processing Board Type K
Specifications of B8200
Dimension 88.4mm(H) x 482.6mm(W) x 197(D)
Weight 8.75kg
Typical Power
240W
consumption
DC Requirement 10A
DCPD6
DCPD6
1,DC input interface Dimensions: 43.6 (h) x 482.6 (w) x 228 (d)
2,Switch for DC output for 9 paths(20A*9 paths) (That means 1U space standard)
3,Connector for DC output 9 paths Weight: 5.0kg
4,LP_ALM provides lighting protection alarm(Dry contact output)
DCPD7
DCPD7
1,DC input interface Dimensions: 43.6 (h) x 482.6 (w) x 228 (d)
2,Switch for DC output for 10 paths(25A*10 paths) (That means 1U space standard)
3,Connector for DC output 10 paths Weight: 5.0kg
4,LP_ALM provides lighting protection alarm(Dry contact output)
R8881,G(120
RRU type R8861, G R8863 G R8862, D R8882,D R8863,D R8861, U R8863 U
W)
Dimensions
Type Weight
(H*W*D)mm
R8882 23Kg 480x320x150
R8881 R8882
Dimensions
Type Weight
(H*W*D)mm
R8881 18Kg 370x320x170
R8861
R8863
Two core DC power cable with shield layer will be used for connection
between DCPD6 and RRU. Size of power cable as choosed below:
Power Max. cable run Max. cable run Max. cable run Max. cable run Max. cable run
Cable for for for for for
Size R8881 R8882 R8861 R8862 R8863
4mm2 >0m =<80m >0m =<55m >0m =<80m >0m =<55m >0m =<30m
6mm2 >80m =<120m >55m =<80m >80m =<120m >55m =<80m >30m =<45m
10mm2 >120m =<205m >80m =<145m >120m =<205m >80m =<145m >45m =<80m
ODCPD1 needed
for R886X if
2*10mm DC
cables used.
Cell 3 Ant
Cell 1 Ant
Cell 2 Ant
AISG Only
for UMTS
R R R
E E E
T T T
AISG
AISG
AISG
Cell 1 Ant
Cell 2 Ant
Cell 3 Ant
R R R
E E E
T T T
AISG
AISG
AISG
ASBT ASBT ASBT
AISG
AISG
AISG TX/RX RX AISG TX/RX RX AISG TX/RX RX
R8861 installed not close to Antenna-More than 20m © ZTE All rights reserved
23
Internal use only▲
Cell 3 Ant
Cell 1 Ant
Cell 2 Ant
R R R
E E E
T T T
AISG cascading AISG cascading
AISG
R8863
Cell 1 Ant
Cell 2 Ant
Cell 3 Ant
R R R
E E E
T T T
AISG cascading AISG cascading
AISG
ASBT
NSBT
AISG
3 Engineering scenarios
4 Output Documents
Internal use only▲
2 DG 18 1 8 5 3 1
3 DGU 125 13 69 17 15 11
4 DU 184 12 130 26 14 2
5 G 58 31 27
6 GU 5 1 3 1
7 U 19 19
Total 464 85 212 103 35 18 11
Connection diagram
sample
Swap procedure
BBU
DCPD7/6
Scenario
Scenario Description Scenario Ratio
No.
1 Shelter + Monopole 34%
+30.000
Антени МТС
DCS/UMTS
UMTS
50
12
Фідерний міст
Приміщення
котельні
Контейнер МТС
2300
2600
3 Engineering scenarios
4 Output Documents
Internal use only▲
Documents output
Survey Photos
Cell Data
TSSR(.Doc)
Drawing(.Dwg or .Vsd)
Scaned TSSR with MTS signature
© ZTE All rights reserved
41
Internal use only▲
Documents output
LVI_SNB_MUK.p
LVI SNB df
MUK_ок.
Other Photos
© ZTE All rights reserved
42
Internal use only▲
Till 2015-10-4
Site Qty of TSSR&Drawing TSSR&Drawing
PO Batch Region Site Qty. of Region TSS Done BOM finished
PO Batch prepared Signed
Uzhorod 87 87 87 87 87
PO_1 133
Mukachevo 46 46 46 46 46
PO_2 80 Lviv 80 80 80 80 80
Lviv 62 62 61 61 62
PO_3 166 Rovno 58 58 57 57
Vinnytsa 46 46 46 46
Ternopil 53 53 53 53
PO_4 85
Khmelnytskiy 32 32 25 24
Total 464 - 464 464 455 454 275
Completion Ratio
© ZTE All rights reserved
43
Internal use only▲