Вы находитесь на странице: 1из 1

PVSYST V5.

59

Pumping system presizing


Geographical Site Khartoum Country Sudan

d e
o
Situation Latitude 15.6°N Longitude 32.5°E
Time defined as Solar Time Altitude 390 m

M
Collector Plane Orientation Tilt 30° Azimuth 0°

n
System pre-sizing evaluation
Average use of water Daily 400.0 m³/day Yearly 146400 m³

io
Required autonomy 5 days Tank volume 2000 m³

t
Loss-of-Load Time fraction 5.0 % Missing Water 7300 m³
Pumping head Average 50 meterW Maximum 50 meterW
Pumping system configuration
PV array
Economic gross evaluation

l u
Regulation
PV Nominal power
Investment
a MPPT-DC converter
28921 Wp
316327 US$
Layout
Pump Power 22896 W
Energy price
DeepWell

0.23 US$/m³

v
PV energy yield and water needs
a Tank Level and Missing Water Probability

E
250 500 120
Available Solar energy 163.7 kWh/day Av. tank filling state 44.7 %
Energy needs 170.1 kWh/day Missing water 5.0 %
Water needs 398.9 m3/day
100
200 400
Water needs [m3/day]

80
Energy [kWh/day]

150 300
Percent

60

100 200
40

50 100
20

0 0 0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Year

Incid. PV avail. PV needs PV Excess Pumped W. Missing W. Missing Fuel

kWh/m².day kWh/day kWh/day kWh/day m³/day m³/day % liter


Jan. 6.8 177.9 170.5 0.3 416.5 0.0 0.0 0.0
Feb. 7.1 183.7 170.5 9.1 409.5 0.0 0.0 0.0
Mar. 7.1 184.0 170.5 15.8 394.4 0.0 0.0 0.0
Apr. 6.6 170.7 170.5 0.0 400.4 0.0 0.0 0.0
May 5.6 146.1 170.5 0.0 342.7 0.0 0.0 0.0
June 5.3 138.8 170.5 0.0 325.6 72.3 18.1 616.6
July 5.2 135.5 170.5 0.0 317.8 82.2 20.6 724.4
Aug. 5.5 143.8 170.5 0.0 337.4 62.6 15.7 551.9
Sep. 6.2 161.4 170.5 0.0 378.7 21.3 5.3 181.8
Oct. 6.7 175.1 170.5 0.0 410.7 0.0 0.0 0.0
Nov. 7.0 181.1 170.5 0.0 424.9 0.0 0.0 0.0
Dec. 6.7 173.6 170.5 0.0 407.1 0.0 0.0 0.0
Year 6.3 164.2 170.5 2.1 380.2 20.0 5.0 2074.7