WIRE CAPACITY CALCULATION OF WINCHDRUM Date: 16/10/19

Project/yardno: 513520- Fore winch

Wire type: 130 m 88 mm synthetic rope

INPUT:
Wire diameter (dw) = 40 mm Type:Euroflex, friction wire, full first layer
Wire diameter (dw) = 88 mm Type:Strongline
Drum diameter (D) = 711 mm
Drum diameter (D), including friction wire
= 791 mm 9.0 x dw
Drum length (L) = 720 mm 8.2 x dw
Extra space on drum (for stretchers) = 140 mm
Pull 1st layer = 35.0 Ton (1) 8.50 Ton (2)
Speed 1st layer = 9.20 m/min (1) 28.00 m/min (2) [rpm] [sec]
Hold.force 1st layer = 150.0 Ton speed 1: 3.33 18.0
speed 2: 10.14 5.9
OUTPUT:
Layer Layer Store- Length Shield Pull Speed Pull Speed Holding
diam. length on drm diameter (1) (1) (2) (2) force
wire Total Minimal
mm m m mm ton m/min ton m/min ton

First 879 21 21 1247 35.0 9.2 8.5 28.0 150.0


Second (1st layer for towing)1031 25 46 1399 29.8 10.8 7.2 32.9 127.8
Third 1184 29 75 1552 26.0 12.4 6.3 37.7 111.4
Fourth 1336 32 107 1704 23.0 14.0 5.6 42.6 98.7
Fifth 1503 36 143 1871 20.5 15.7 5.0 47.9 87.8

Non prefered layers for fibre rope


Sixth 1655 40 183 2023 18.6 17.3 4.5 52.7 79.7
Seventh 1807 44 227 2175 17.0 18.9 4.1 57.6 73.0
Eighth 1960 47 274 2328 15.7 20.5 3.8 62.4 67.3

Non prefered layers for steel wire


Ninth 2112 51 325 2480 14.6 22.1 3.5 67.3 62.4
Tenth 2265 55 380 2633 13.6 23.7 3.3 72.1 58.2
Eleventh 2417 58 438 2785 12.7 25.3 3.1 77.0 54.5
Twelfth 2569 62 500 2937 12.0 26.9 2.9 81.8 51.3

Notes:
Maximum prefered number of layers is 5 for fibre rope & 8 for steel wire, see also drawing 500000-550-852
Minimum drum diameter for steel wire 13 x dw, for synthetic wire 5 x dw
Minimum shield diameter is based on : 140 mm extra space above the top layer
Prefered extra space for stretchers is 200mm
| |