Specifications:
PE 4710 Resin formulation listed in PPI TR4
Hydrostatic Design Basis: 1600 psi @ 73° F, 1000 psi @ 140° F
Cell Classification per ASTM D3350 = 445574C and 445576C
¾” – 3” pipe: ASTM D3035 and AWWA/ANSI C901
4” – 24” pipe: ASTM F714 and AWWA/ANSI C906
Pipe is made from an NSF listed resin formulation
Pressure Ratings:
If temperatures exceed 80ºF, contact Charter Plastics for a working pressure de-rating.
Joining:
Charter Plastics Green Stripe IPS pipe is based on outside diameter. Heat fusion is the preferred method for joining
this pipe. All personnel conducting heat fusions should be experienced and follow guidelines published by the pipe
manufacturer or by PPI in TR 33.
IPS may also be joined with OD Mechanical fittings designed for pipe made to ASTM F714 or ASTM D3035 Standards.
A stiffener should be inserted when using OD Compression type fittings on pipe < 2”.
Never use any lubricant on the pipe. Do not expose the pipe to direct flame.
Installing:
All Charter Plastics IPS pipe can be direct buried and can be installed with a vibrating plow, pulled or horizontally
directionally drilled. Buried pipe must be supported by proper embedment material like sand or gravel. Refer to PPI’s
Pipe for a New World.
“Handbook of Polyethylene Pipe” and follow as local, state or federal guidelines.
To safely handle and store polyethylene, refer to PPI’s Material Handling Guide.
*This pipe is not designed for use inside the building or for hot water applications.
Testing:
All pipe should be hydrostatically tested after installation.
Pneumatic testing is not recommended.
Refer to PPI’s Handbook of Polyethylene Pipe for Guidelines.
PE 4710 IPS – SEWER PIPE
Information provided in this document is accurate and reliable to the best of our knowledge. The user of such information assumes all risk connected with the use thereof. Charter Plastics Inc. assumes no responsibility for the use of information
presented here in and disclaim all liability in regard to such use. For the most accurate and updated document, please refer to the latest version available online at www.charterplastics.com. Release date of this document is 4/19/18.
SEWER
14’ or
NOTE: Canadian PVC sewer pipe specifications are available upon request. This
Engineering submittal specification is for products delivered in the U.S. only.
Page 1 of 2
Updated 1/3/18
SEWER
14’ or
NOTE: This engineering submittal specification is for products delivered in the U.S. only.
Page 2 of 2 Updated
10/12/15
Marking Tape, Detectable - Omega Marking Co.
OMEGA MARKING COMPANY
P.O. Box 655 Beaver Dam, WI 53916
Voice: 920-478-4922 Fax; 920-478-4893
MANUFACTURING SPECIFICATIONS
• Subsurface graphics
• Triple-layer lamination
APPLICATIONS
• Detectable warning tape is used for protection, early identification, and accurately
locating underground utility installations
• Use appropriate legend & A.P.W.A. colored tape to specify the type of utility being
protected
• A.P.W.A. color code denotes: Orange--Telecommunication and CATV Lines, Blue--
Water Lines, Green--Sewer Lines, , Purple--Reclaimed Water Lines, Red--Electrical
Lines, Yellow--Gas Lines
PRODUCT ANALYSIS
ATTRIBUTE PROCEDURE VALUE*
Thickness ASTM D 2103 5.0 Overall Thickness
Elongation ASTM D 88280A
MD 80%
TD 139%
Density ASTM D 792-66 1.090 (gm/cc)
Coefficient of Friction ASTM D 3248-73 Static 0.247
Tensile Strength ASTM D 882 5,800 PSI
Printability ASTM D 2578 Min .45 Dynes
Flexibility ASTM D 671-76 Pliable Hand
Graphic Repeat MFRG. SPECS Repeat Every 23”
ENDORSEMENTS
• Meets federal gas safety regulation S-192-321(E)
• Meets OSHA regulation 1926-956 (C) (I) covering the location of underground utility
lines