Академический Документы
Профессиональный Документы
Культура Документы
This software and related documentation are provided under a license agreement containing restrictions on use and disclosure and are protected by intellectual
property laws. Except as expressly permitted in your license agreement or allowed by law, you may not use, copy, reproduce, translate, broadcast, modify, license,
transmit, distribute, exhibit, perform, publish, or display any part, in any form, or by any means. Reverse engineering, disassembly, or decompilation of this software,
unless required by law for interoperability, is prohibited.
The information contained herein is subject to change without notice and is not warranted to be error-free. If you find any errors, please report them to us in writing.
If this is software or related documentation that is delivered to the U.S. Government or anyone licensing it on behalf of the U.S. Government, the following notice is
applicable:
U.S. GOVERNMENT END USERS. Oracle programs, including any operating system, integrated software, any programs installed on the hardware, and/or
documentation, delivered to U.S. Government end users are "commercial computer software" pursuant to the applicable Federal Acquisition Regulation and
agency-specific supplemental regulations. As such, use, duplication, disclosure, modification, and adaptation of the programs, including any operating system,
integrated software, any programs installed on the hardware, and/or documentation, shall be subject to license terms and license restrictions applicable to the
programs. No other rights are granted to the U.S. Government.
This software or hardware is developed for general use in a variety of information management applications. It is not developed or intended for use in any inherently
dangerous applications, including applications that may create a risk of personal injury. If you use this software or hardware in dangerous applications, then you shall
be responsible to take all appropriate fail-safe, backup, redundancy, and other measures to ensure its safe use. Oracle Corporation and its affiliates disclaim any
liability for any damages caused by use of this software or hardware in dangerous applications.
Oracle and Java are registered trademarks of Oracle and/or its affiliates. Other names may be trademarks of their respective owners.
Intel and Intel Xeon are trademarks or registered trademarks of Intel Corporation. All SPARC trademarks are used under license and are trademarks or registered
trademarks of SPARC International, Inc. AMD, Opteron, the AMD logo, and the AMD Opteron logo are trademarks or registered trademarks of Advanced Micro
Devices. UNIX is a registered trademark of The Open Group.
This software or hardware and documentation may provide access to or information on content, products, and services from third parties. Oracle Corporation and
its affiliates are not responsible for and expressly disclaim all warranties of any kind with respect to third-party content, products, and services. Oracle Corporation
and its affiliates will not be responsible for any loss, costs, or damages incurred due to your access to or use of third-party content, products, or services.
Ce logiciel et la documentation qui l’accompagne sont protégés par les lois sur la propriété intellectuelle. Ils sont concédés sous licence et soumis à des restrictions
d’utilisation et de divulgation. Sauf disposition de votre contrat de licence ou de la loi, vous ne pouvez pas copier, reproduire, traduire, diffuser, modifier, breveter,
transmettre, distribuer, exposer, exécuter, publier ou afficher le logiciel, même partiellement, sous quelque forme et par quelque procédé que ce soit. Par ailleurs, il est
interdit de procéder à toute ingénierie inverse du logiciel, de le désassembler ou de le décompiler, excepté à des fins d’interopérabilité avec des logiciels tiers ou tel que
prescrit par la loi.
Les informations fournies dans ce document sont susceptibles de modification sans préavis. Par ailleurs, Oracle Corporation ne garantit pas qu’elles soient exemptes
d’erreurs et vous invite, le cas échéant, à lui en faire part par écrit.
Si ce logiciel, ou la documentation qui l’accompagne, est concédé sous licence au Gouvernement des Etats-Unis, ou à toute entité qui délivre la licence de ce logiciel
ou l’utilise pour le compte du Gouvernement des Etats-Unis, la notice suivante s’applique:
U.S. GOVERNMENT END USERS. Oracle programs, including any operating system, integrated software, any programs installed on the hardware, and/or
documentation, delivered to U.S. Government end users are "commercial computer software" pursuant to the applicable Federal Acquisition Regulation and
agency-specific supplemental regulations. As such, use, duplication, disclosure, modification, and adaptation of the programs, including any operating system,
integrated software, any programs installed on the hardware, and/or documentation, shall be subject to license terms and license restrictions applicable to the
programs. No other rights are granted to the U.S. Government.
Ce logiciel ou matériel a été développé pour un usage général dans le cadre d’applications de gestion des informations. Ce logiciel ou matériel n’est pas conçu ni n’est
destiné à être utilisé dans des applications à risque, notamment dans des applications pouvant causer des dommages corporels. Si vous utilisez ce logiciel ou matériel
dans le cadre d’applications dangereuses, il est de votre responsabilité de prendre toutes les mesures de secours, de sauvegarde, de redondance et autres mesures
nécessaires à son utilisation dans des conditions optimales de sécurité. Oracle Corporation et ses affiliés déclinent toute responsabilité quant aux dommages causés
par l’utilisation de ce logiciel ou matériel pour ce type d’applications.
Oracle et Java sont des marques déposées d’Oracle Corporation et/ou de ses affiliés. Tout autre nom mentionné peut correspondre à des marques appartenant à
d’autres propriétaires qu’Oracle.
Intel et Intel Xeon sont des marques ou des marques déposées d’Intel Corporation. Toutes les marques SPARC sont utilisées sous licence et sont des marques ou des
marques déposées de SPARC International, Inc. AMD, Opteron, le logo AMD et le logo AMD Opteron sont des marques ou des marques déposées d’Advanced Micro
Devices. UNIX est une marque déposée d’The Open Group.
Ce logiciel ou matériel et la documentation qui l’accompagne peuvent fournir des informations ou des liens donnant accès à des contenus, des produits et des services
émanant de tiers. Oracle Corporation et ses affiliés déclinent toute responsabilité ou garantie expresse quant aux contenus, produits ou services émanant de tiers. En
aucun cas, Oracle Corporation et ses affiliés ne sauraient être tenus pour responsables des pertes subies, des coûts occasionnés ou des dommages causés par l’accès à
des contenus, produits ou services tiers, ou à leur utilisation.
120929@25097
Contents
3
Contents
Index ......................................................................................................................................................79
4 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
Using This Documentation
This section provides product information, documentation and feedback links, and a document
change history.
■ “Sun Server X2-8 Name Change” on page 5
■ “Product Downloads” on page 5
■ “Documentation and Feedback” on page 6
■ “About This Documentation” on page 7
■ “Change History” on page 7
Product Downloads
You can find downloads for all Oracle x86 servers and server modules (blades) on Support
(MOS). On MOS you can find two type of downloads:
■ Software release bundles specific to the rackmount server, server module, modular system
(blade chassis), or NEM. These software release bundles include Oracle ILOM, Oracle
Hardware Installation Assistant and other platform software and firmware.
■ Standalone software common across multiple types of hardware. This includes the
Hardware Management Pack and Hardware Management Connectors.
5
Documentation and Feedback
1 Go to http://support.oracle.com.
3 At the top of the page, click the Patches and Updates tab.
5 In the Product ? is field, type a full or partial product name, for example, Sun Server X2-8 until a
list of matches is displayed and select the product of interest.
7 In the window that appears, click the triangle (>) by the product folder icon to show the choices
and then select the release of interest and click Close.
9 Select the Patch name of interest, for example, 12684585, for the Sun Server X2-8 1.0 Firmware.
6 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
Change History
You can get a PDF that includes all information about a particular topic subject (such as
hardware installation or product notes) by clicking the PDF button on the top of the page.
Change History
The following lists the release history of this documentation set:
■ July 2011 – Initial publication.
■ October 2011 – Revised for SW1.1.
■ January 2012 – Revised for SW1.2.
■ April 2012 – Revised to add preinstalled Oracle VM, and additional rack mounting
instructions.
■ June 2012 – Revised to add the preinstalled Solaris 11 operating system.
■ July 2012 – Revised to change name and to add 32 Gb DIMMs.
7
8
Overview of the Diagnostics Guide
Description Link
Use Oracle ILOM to monitor the host. “Using Oracle ILOM to Monitor the Host” on page 31
Use SunVTS to diagnose server problems. “Using SunVTS Diagnostics Software ” on page 51
Use Pc-Check to diagnose server problems. “Performing Pc-Check Diagnostic Tests” on page 55
Note – The Sun Server X2-8 was formerly named the Sun Fire X4800 M2 server. This former
name might still appear in the product. The name change does not indicate any change in
system features or functionality.
9
10
Introduction to System Diagnostics
This section contains an introduction to the Oracle Sun Server X2-8 diagnostics and covers the
following topics:
■ “Troubleshooting Options” on page 11
■ “Diagnostic Tools” on page 12
Troubleshooting Options
The following table lists the suggested order of troubleshooting procedures when you have an
issue with the server.
1 Gather initial service visit information. “How to Gather Service Visit Information” on
page 13
3 Perform external visual inspection and “How to Externally Inspect the Server” on page 14
internal visual inspection.
“How to Internally Inspect the Server” on page 14
5 View BIOS event logs and POST messages. “BIOS POST” on page 27
6 View service processor logs and sensor “Using Oracle ILOM to Monitor the Host” on
information. page 31
7 Collect diagnostics data for Oracle Service. “Creating a Data Collector Snapshot” on page 47
11
Diagnostic Tools
Diagnostic Tools
The following diagnostic tools are available for the Sun Server X2-8.
BIOS POST
From the point that the host subsystem is powered on and begins executing code, BIOS code is
executed. The sequence that BIOS goes through, from the first point where code is executed to
the point that the operating system booting begins, is referred to as POST (power-on self-test).
POST works in conjunction with other processes to complete initialization and booting. POST
focuses on thoroughly testing devices as well as providing meaningful information to users
when errors occur. For more information about BIOS POST diagnostics, see “BIOS POST” on
page 27 .
SunVTS
SunVTS is the Sun Validation Test Suite, which provides a comprehensive diagnostic tool that
tests and validates Sun hardware by verifying the connectivity and functionality of most
hardware controllers and devices on Sun platforms. SunVTS software can be tailored with
modifiable test instances and processor affinity features.
For more information about using the Sun VTS to diagnose system issues, see “Using SunVTS
Diagnostics Software ” on page 51.
Pc-Check
The Pc-Check diagnostics can test and detect problems on all motherboard components, drives,
ports, and slots. This program can be accessed and executed from the Oracle ILOM. For more
information about using Pc-Check, see “Performing Pc-Check Diagnostic Tests” on page 55.
U-Boot Diagnostics
U-Boot diagnostics run automatically when the server is started or booted. However, to see the
output, you must connect a serial terminal to the SER MGT port on the SP. U-Boot tests basic
hardware functions to ensure that there is enough functionality to boot the SP. For more
information, see “U-Boot Diagnostic Start-Up Tests” on page 69.
12 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
Troubleshooting the Server
3 Take note of the results of any change you make. Include any errors or informational messages.
4 Check for potential device conflicts, especially if you have added a new device.
13
Troubleshooting the Server
■ Check that AC power cords are attached firmly to the server’s power supplies and to the AC
sources.
■ Check the PSU Fault LED on the power supplies. If any of them are ON, that power supply is in
a faulted state.
■ Check that the power OK LED on the server front panel is steady ON. If it is blinking, the
server is in standby power mode. For instructions to bring it to full power mode, see: .
“Powering the Server On and Off” in Sun Server X2-8 (formerly Sun Fire X4800 M2)
Installation Guide
2 Verify that nothing in the server environment is blocking air flow or making a contact that could
short out power.
3 If the problem is not evident, continue with “How to Internally Inspect the Server”on page 14.
14 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
Troubleshooting the Server
Caution – When you use the Power button to enter standby power mode, power is still
directed to the service processor board and power supply fans, indicated when the
Power/OK LED is flashing. To completely power off the server, you must disconnect the AC
power cords from the back panel of the server.
The following illustration shows the recessed Power button on the upper left-hand side of the
system front panel.
1 2
5-2M 5-2M
5-2M 5-2M
5-2M 5-2M
5-2M 5-2M
Label Description
1 Power/OK LED
2 Power button
3 Inspect the internal status indicator LEDs, which can indicate component malfunction.
For the LED locations and descriptions of their behavior, see “Troubleshooting DIMM
Problems” on page 17.
15
Troubleshooting the Server
5 Verify that all cable connectors inside the system are firmly and correctly attached to their
appropriate connectors.
7 Check that the installed DIMMs comply with the supported DIMM population rules and
configurations, as described in “Troubleshooting DIMM Problems”on page 17.
9 Repeat Step 2 through Step 8 for each CPU module that needs to be inspected.
10 To restore full power mode to the chassis, (all components powered on), press and release the
Power button on the server front panel.
When main power is applied to the full server, the Power/OK LED next to the Power button
blinks intermittently untill BIOS POST finishes.
11 If the problem with the server is not evident, you can try viewing the power-on self-test (POST)
messages and BIOS event logs during system startup.
Refer to the Sun Server X2-8 (formerly Sun Fire X4800 M2) Service Manual for more
information about POST and BIOS event logs.
16 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
Troubleshooting DIMM Problems
In this section, the term “CPU module” or CMOD refers to a full CPU blade, including all CPUs
and DIMMs on the blade. The term “CPU” refers to a single CPU.
Note – For information about Oracle’s DIMM replacement policy for x86 servers, contact your
Oracle Service representative.
All DIMMs are configured, identified, and replaced in pairs. When there is a fault in a DIMM,
you must replace both the faulty DIMM and the other DIMM in the pair. To identify DIMM
pairings, see “DIMM Hardware” on page 24.
Because of the server's architecture, when the server detects a faulty DIMM, it disables other
DIMM pairs as well. When the Oracle ILOM displays the faulty DIMMs, it also displays the
disabled DIMMs. However, they are clearly identified as disabled, not faulty. When the faulty
DIMMs are repaired, the server automatically places the disabled DIMMS back into service.
17
Troubleshooting DIMM Problems
Caution – Before handling components, attach an antistatic wrist strap to a chassis ground (any
unpainted metal surface). The system’s printed circuit boards and hard disk drives contain
components that are extremely sensitive to static electricity.
Before You Begin This task requires access to the Oracle ILOM and the ability to remove a CMOD from the
server. It also requires that you have a pair of DIMMs to replace the faulty pair.
1 Use the Oracle ILOM CLI or web interface to identify the CMOD and the faulty DIMMs.
■ From the CLI:
Enter the show faulty command.
If the system has detected a faulty DIMM pair, the output contains one or more entries
similar to the following:
Target | Property | Value
--------------------+------------------------+---------------------------------
/SP/faultmgmt/0 | fru | /SYS/BL0/P0/D0
/SP/faultmgmt/0/ | class | fault.memory.intel.dimm_ue
faults/0 | |
This identifies the faulty pair as DIMM 0 and DIMM 4 on CPU 0 of CMOD 0 (BL0).
Note – This display might include other DIMM pairs that have been temporarily disabled.
These are automatically returned to service when the faulty DIMM pair is repaired.
18 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
Troubleshooting DIMM Problems
Note – This display might include other DIMM pairs that have been temporarily disabled. These
are automatically returned to service when the faulty DIMM pair is repaired.
2 Remove the CMOD that has the faulty DIMMs, and then remove the CMOD cover.
Refer to “Adding, Removing, and Installing a CMOD (CRU)” in Sun Server X2-8 (formerly Sun
Fire X4800 M2) Service Manual.
3 Press the Fault Remind button on the CMOD to light the DIMM fault LEDs for any faulty DIMM
pairs.
The LEDs on the board adjacent to the DIMM slots light to identify faulty DIMM pairs.
For the locations of DIMM fault LEDs, DIMM pairs, and the fault remind button, see “DIMM
Hardware” on page 24.
19
Troubleshooting DIMM Problems
Note – If the DIMM fault LEDs do not identify the same DIMM pair as the Oracle ILOM, contact
Oracle Service.
4 Visually inspect the DIMMs and the DIMM slots for damage or contamination.
■ If a DIMM is damaged, replace the DIMM pair.
■ If the DIMM slot is cracked or broken, contact Oracle Service.
■ If there is dirt or other contamination on the DIMM or on the slot, you might choose to
clean it, reseat the DIMMs, and check the system again.
Refer to “Removing and Installing DIMMs (CRU)” in Sun Server X2-8 (formerly Sun Fire X4800
M2) Service Manual for additional information.
7 If the problem persists, run the following Oracle ILOM command sequence for each faulty DIMM:
—> set /SYS/MB/Px/Dy clear_fault_action=true
Are you sure you want to clear /SYS/MB/Px/Dx (y/n) y
Set ’clear_fault_action’ to true
Where x is the node number and y is the DIMM number.
This command clears the DIMM of random information that might be interpreted as faulty
data.
8 If the problem persists, see “How to Isolate and Correct Persistent DIMM Errors”on page 21.
See Also ■ “How to Isolate and Correct Persistent DIMM Errors” on page 21
■ “DIMM Hardware” on page 24
20 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
Troubleshooting DIMM Problems
Caution – Before handling components, attach an antistatic wrist strap to a chassis ground (any
unpainted metal surface). The system’s printed circuit boards and hard drives contain
components that are extremely sensitive to static electricity.
1 If you have not already done so, shut down the system to standby power mode, remove the
CMOD, and remove the cover of the CMOD.
Refer to “Adding, Removing, and Installing a CMOD (CRU)” in Sun Server X2-8 (formerly Sun
Fire X4800 M2) Service Manual.
2 Exchange the DIMM pairs between the two CPU slots. Ensure that they are inserted correctly
with the ejector latches secured.
For example, if the faulty pair is DIMM 0 and DIMM 4 on CPU 0:
21
Additional Tests
See Also ■ “How to Detect DIMM Errors Using BIOS POST and the Oracle ILOM SEL” on page 22
■ “How to Detect DIMM Errors Using the CE Log” on page 23
■ “DIMM Hardware” on page 24
Additional Tests
This section provides two alternative methods of detecting DIMM errors. They include:
■ “How to Detect DIMM Errors Using BIOS POST and the Oracle ILOM SEL” on page 22
■ “How to Detect DIMM Errors Using the CE Log” on page 23
▼ How to Detect DIMM Errors Using BIOS POST and the Oracle ILOM SEL
When the server is started or rebooted, the BIOS POST tests memory by performing a
write/read test of every location using the pattern 55aa. Then BIOS polls the memory
controllers for both correctable and non correctable memory errors, and logs those errors into
the SP SEL.
For more information about BIOS POST, see “BIOS POST” on page 27.
1 Log in to the Oracle ILOM and access the system event log using the web interface or CLI.
See “Viewing the Oracle ILOM System Event Log” on page 39.
22 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
Additional Tests
Consider the data from the preceding sample (0x12). In binary, it is 0001,0010.
■ Bits 6-7 = 00. This identifies the error as an ECC memory error. It should not change.
■ Bits 4-5 = 01. This identifies the memory branch. This number is unused in this context.
■ Bits 0-3 = 0010. Converted to decimal, these identify CPU node 2.
Nodes map to CPUs as follows:
The following table shows the mapping of nodes to CMODs and CPUs. In the physical
system, CMOD 0 is on the bottom, and CMOD 3 is on the top.
2 3 0
3 1
6 2 0
7 1
4 1 0
5 1
0 0 0
1 1
BIOS updates the CE log every five minutes. After changing something, you must wait five
minutes to ensure that the data in the CE log reflects the results of that change.
23
DIMM Hardware
2 3 0
3 1
6 2 0
7 1
4 1 0
5 1
0 0 0
1 1
The preceding example identifies the faulty DIMM pair as DIMMs 0,3 in CPU 0 of CMOD 2.
DIMM Hardware
This section shows the locations of DIMM pairs, DIMM fault LEDs, and the fault remind
button.
24 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
DIMM Hardware
Label Description
The following illustration shows the mapping of the DIMMs on the CMOD.
25
DIMM Hardware
D12
D13
D14
D15
D7
D6 2
D5
D4
D0 D11
D1 D10
D2 D9
3 D3 D8
D11 D15
D10 D14
D9 D13
D8 D12
1
D3 D7
D2 D6
D1 D5
D0 D4
Label Description
1 DIMMs on CPU 0
2 DIMMs on CPU 1
26 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
BIOS POST
This section contains information about BIOS POST diagnostics. This section includes the
following topics:
■ “Default BIOS Power-On Self-Test (POST) Events” on page 27
■ “BIOS POST Errors” on page 28
Correctable ECC Correctable ECC (error correction code) error detected. Yes
No usable system memory All installed memory has experienced an unrecoverable failure. No
27
BIOS POST Errors
Initiated by warm reset Boot process started by warm reset. Does not apply
PCI resource initialization BIOS initializes PCI resources. Does not apply
USB resource configuration BIOS configures USB resources. Does not apply
Option ROM initialization BIOS initializes Option ROMs. Does not apply
System firmware progress.
Not enough option ROM space allocated for BIOS cannot copy an option ROMs content to the memory. This Maybe booting over
device is likely due to a large number of EMs (express modules) attached an EM not possible.
to the system.
User initiated system set up End user initiated access to BIOS setup utility. Does not apply
System firmware progress.
PXE server not found Boot error - PXE server not found. No
ACPI power state Soft-off power on (S0) or off (S5). Does not apply
Not enough IO address space allocated for Cannot allocate resources to an on-board device (PEM, REM, Yes
device FEM), and slot is disabled.
28 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
BIOS POST Errors
The following table lists some of the error messages that might appear during the POST
diagnostics, and provides instructions for resolving the errors.
Note – Contact Oracle Service for information about interpreting and applying the Oracle ILOM
log information that you receive on these errors.
Uncorrectable Error Detected on Last Boot:IOH(0) Protocol IOH error Check the SP event log in Oracle ILOM for more
Error (Please Check SP Log for more Details) details.
Uncorrectable Error Detected on Last Boot:IOH(0) QPI [x] IOH error Check the fault management function and the SP
Error (Please Check SP Log for more Details) event log in Oracle ILOM for more details.
Note – Where QPI [ x] equals 0 for QPI Link 0 or 1 for QPI
Link 1.
Uncorrectable Error Detected on Last Boot:IOH(0) PCI-E [x] IOH error Check the fault management function and the SP
Error (Please Check SP Log for more Details) event log in Oracle ILOM for more details.
Note – Where PCI-E [ x] port number can range from 1 to 10
depending on the PCI root port on IOH.
Uncorrectable Error Detected on Last Boot:IOH(0) ESI Error IOH error Check the fault management function and the SP
(Please Check SP Log for more Details) event log in Oracle ILOM for more details.
Uncorrectable Error Detected on Last Boot:IOH(0) Thermal IOH error Check the fault management function and the SP
Error (Please Check SP Log for more Details) event log in Oracle ILOM for more details.
Uncorrectable Error Detected on Last Boot:IOH(0) IOH error Check the fault management function and the SP
Miscellaneous Error (Please Check SP Log for more Details) event log in Oracle ILOM for more details.
Uncorrectable Error Detected on Last Boot:IOH(0) VT-d IOH error Check the SP event log in Oracle ILOM for more
Error (Please Check SP Log for more Details) details.
BMC Not Responding ILOM error This error message might appear if an internal error
occurs during the SP/BIOS communication. This
error might require you to restart the SP.
Hard disk error SAS error Check the SP event log in Oracle ILOM for more
details.
Note – These error messages appear when the BIOS is
attempting to configure SAS devices in POST.
Bad PBR sig Hard disk error This is caused by a corrupted or nonexistent
partition table on the disk drive. A disk utility
(Oracle Solaris format or Linux fdisk) must be used
to format the tables again.
29
BIOS POST Errors
RAM R/W test failed Memory test Check the SP event log in Oracle ILOM for more
failure details.
Note – This type of error typically indicates that the
RAM read/write test failed.
CMOS Battery Low CMOS battery ■ Check the SP event log in Oracle ILOM for more
error details.
■ If necessary, replace CMOS battery.
■ CMOS Checksum Bad CMOS error Check the SP event log in Oracle ILOM for more
■ CMOS Date/Time Not Set details.
Password check failed Password Check the SP event log in Oracle ILOM for more
check error details.
Note – This type of error indicates that the password
entered does not match the password specified in the
BIOS setup utility. This condition might occur for
both Supervisor and User password verification.
30 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
Using Oracle ILOM to Monitor the Host
This section describes how to view server sensor readings and view the system event log.
This section contains the following procedures:
■ “Viewing the Oracle ILOM Sensor Readings” on page 31
■ “Viewing Fault Status” on page 34
■ “Clearing Faults” on page 38
■ “Viewing the Oracle ILOM System Event Log” on page 39
■ “Clearing the System Event Log” on page 43
■ “Interpreting Event Log Time Stamps” on page 45
■ “Resetting the SP” on page 45
▼ How to Use the Oracle ILOM Web Interface to View the Sensor Readings
Before You Begin This procedure requires Read Only (o) permission.
1 To reach the Oracle ILOM web interface, log in to the SP as Administrator or Operator:
31
Viewing the Oracle ILOM Sensor Readings
Note – If the server is powered off, many components will have no readings.
32 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
Viewing the Oracle ILOM Sensor Readings
b. Click the name of the sensor to view the property values associated with that sensor.
For specific details about the type of discrete sensor targets you can access, as well as the
paths to access them, refer to the Oracle Integrated Lights Out Manager (ILOM) 3.0
Supplement for the Sun Server X2-8 (formerly Sun Fire X4800 M2).
4 If the problem with the server is not evident after you view the sensor readings information,
continue with “Using SunVTS Diagnostics Software ”on page 51.
2 Type the following commands to navigate to the sensor target and then to view the sensor
properties:
->cd target
->show
where target is the sensor that you want to view.
For example, you can specify the following path to view a temperature reading of the system's
ambient air intake:
->cd /SYS/T_AMB
->show
The properties that describes the sensor target appear. For example:
Properties:
type = Temperature
33
Viewing Fault Status
ipmi_name = T_AMB
class = Threshold Sensor
value = 18.000 degree C
upper_nonrecov_threshold = 45.000 degree C
upper_critical_threshold = 40.000 degree C
upper_noncritical_threshold = N/A
lower_noncritical_threshold = N/A
lower_critical_threshold = N/A
lower_nonrecov_threshold = N/A
alarm_status = cleared
34 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
Viewing Fault Status
▼ How to View Fault Status Using the Oracle ILOM Web Interface
Before You Begin To view fault status, you need the Read Only (o) role enabled.
2 There are two ways to view faults through the web interface:
The Fault Management screen lists faulted components by ID, FRU, and time stamp. You
can access additional information about the faulted component by clicking the faulted
component ID.
35
Viewing Fault Status
For more information about an item that has Faulted status, click the component name.
36 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
Viewing Fault Status
37
Clearing Faults
Clearing Faults
You can clear a fault from Oracle ILOM after the fault has been corrected.
3 Locate the component that is in the Faulted state and select the radio button to the left of the
component name.
38 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
Viewing the Oracle ILOM System Event Log
2 Use the following command to clear the fault for a specific component.
–>set pathtocomponent clear_fault_action=true
where pathtocomponent is the path to the component for which you want to clear the fault.
For example:
set /SYS/BL0/P0/D0 clear_fault_action=true
▼ How to View the System Event Log Using the Oracle ILOM Web Interface
Events are notifications that occur in response to some actions. The IPMI system event log
(SEL) provides status information about the server’s hardware and software to the Oracle ILOM
software, which displays the events in the Oracle ILOM web interface.
39
Viewing the Oracle ILOM System Event Log
1 Log in to the SP as Administrator or Operator to reach the Oracle ILOM web interface:
40 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
Viewing the Oracle ILOM System Event Log
Note – Selecting a greater number of entries might cause the web interface to respond more
slowly than if you select fewer entries.
■ View the entries in the display by scrolling through the list – the following table provides
descriptions about each column appearing in the log.
Date/Time The day and time the event occurred. If the Network
Time Protocol (NTP) server is enabled to set the
Oracle ILOM time, the Oracle ILOM clock uses
Universal Coordinated Time (UTC).
Note – The Oracle ILOM event log accumulates many types of events, including copies of IPMI
entries. Clearing the Oracle ILOM event log clears all entries in the log, including the IPMI
entries. However, clearing the Oracle ILOM event log entries does not clear the actual entries
posted directly to an IPMI log.
41
Viewing the Oracle ILOM System Event Log
▼ How to View the System Event Log With the Oracle ILOM
Command-Line Interface
Before You Begin This procedure requires Administration (a) permission.
1 Establish a local serial console connection or SSH connection to the server SP.
Refer to Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Server X2-8
(formerly Sun Fire X4800 M2) for more information.
42 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
Clearing the System Event Log
4 To scroll down the list to view entries, press any key except q. The following table provides
descriptions about each column appearing in the log.
Date/Time The day and time the event occurred. If the Network Time Protocol (NTP) server is
enabled to set the Oracle ILOM time, the Oracle ILOM clock uses Universal
Coordinated Time (UTC).
5 To dismiss the event log (stop displaying the log), press the q key.
43
Clearing the System Event Log
▼ How to Clear the System Event Log Using the Oracle ILOM Web
Interface
1 Navigate to the Event Log from the Oracle ILOM System Monitoring tab.
2 Click the Clear Log button on the bottom of the Event Log screen.
▼ How to Clear the System Event Log Using the Oracle ILOM
Command-Line Interface
1 Type the following command:
cd /SP/logs/event/
set clear=true
A confirmation message appears.
44 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
Resetting the SP
Resetting the SP
If you need to reset your Oracle ILOM service processor (SP), you can do so without affecting
the host OS. However, resetting an SP disconnects your current Oracle ILOM session and
renders the SP unmanageable during reset.
45
Resetting the SP
46 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
Creating a Data Collector Snapshot
The Oracle ILOM Service Snapshot utility is used to collect data for use by Oracle Services
personnel, who use the data to diagnose system problems. You should not run this utility unless
requested to do so by Oracle Services.
Caution – You should not run this utility unless requested to do so by Oracle Services.
47
Creating a Data Collector Snapshot
3 Select the data set you want: Normal, FRU ID, Full, or Custom.
■ Normal – Specifies that Oracle ILOM, operating system, and hardware information is
collected.
■ Full – Specifies that all data is collected. Selecting Full might reset the system.
■ Custom – Allows you to choose one or more of the following data sets:
■ Oracle ILOM data
■ Hardware data
■ Basic OS data
■ Diagnostic data
4 Select the Enabled check box if you want to collect only log files from the data set.
5 Select the Enabled check box if you want to encrypt the output file.
48 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
Creating a Data Collector Snapshot
7 Click Run.
A Save As dialog box appears.
8 In the dialog box, specify the directory to which to save the file and the file name.
9 Click OK.
The utility places a zip file in the specified directory.
Caution – You should not run this utility unless requested to do so by Oracle Services.
Before You Begin To collect SP data using the Service Snapshot utility, you need the Admin (a) role enabled.
49
Creating a Data Collector Snapshot
URI Any valid target Specifies the URI of the target directory. The URI
directory format is as follows:
location protocol://username:password@host/directory
where protocol can be one of these transfer
methods: SFTP or FTP.
For example, to store the snapshot information in
the directory named data on the host, define the
URI as follows:
ftp://joe:mypasswd@host_ip_address/data
The directory data is relative to the user login, so
the directory would probably be /home/joe/data.
50 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
Using SunVTS Diagnostics Software
The Sun Validation Test Suite (SunVTS) provides a comprehensive diagnostic tool that tests
and validates Oracle hardware by verifying the connectivity and functionality of most hardware
controllers and devices on Oracle platforms.
SunVTS provides a comprehensive diagnostic tool that tests and validates Oracle hardware by
verifying the connectivity and functionality of most hardware controllers and devices on Oracle
platforms.
SunVTS software has a graphical user interface (GUI) that provides test configuration and
status monitoring. The user interface can be run on one system to display the SunVTS testing of
another system on the network. SunVTS software also provides a TTY-mode interface for
situations in which running a GUI is not possible.
51
SunVTS Log Files
■ HBA
SunVTS Documentation
For the most up-to-date information about SunVTS, go to:
http://download.oracle.com/docs/cd/E19719-01/index.html
■ On any system:
■ Download the SunVTS ISO file. See your server download page for details.
52 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
SunVTS Documentation
■ After downloading the ISO file, copy it to a local drive or a to a CD/DVD, and use Oracle
ILOM redirection to boot it. See your Oracle ILOM documentation for information
about redirection.
2 Press Enter or click the Start button when you are prompted to start the tests.
The test suite runs until it encounters an error or the test is completed.
3 When the test stops, review the log files generated during the test.
For a description of the log files, see “SunVTS Log Files” on page 52.
To view a log file:
b. Specify the log file that you want to view by selecting it from the Log file windows.
The content of the selected log file appears in the windows.
53
54
Performing Pc-Check Diagnostic Tests
This section describes how to use the Pc-Check diagnostic tests for the Sun Server X2-8,
provided through the Oracle Integrated Lights Out Manager (Oracle ILOM).
To run Pc-Check, you can use Oracle ILOM to select one of the following options, then boot the
server:
■ Manual – Runs Pc-Check in manual mode and brings you to a Pc-Check menu.
■ Enabled – Runs basic diagnostics and takes about 3 minutes.
■ Extended – Runs detailed diagnostics and takes about 30 minutes.
■ Disabled – Pc-Check does not run. Use this selection for normal system operation.
The only way you can see the results of Pc-Check diagnosis is to run Pc-Check in Manual mode.
The output is displayed on a monitor or serial console connected to the system. See “Viewing
the Pc-Check Results” on page 64. The results of the Enabled and Extended tests are also
written to nonvolatile memory on the SP, where Oracle Services can access them.
55
Pc-Check Diagnostics Overview
Note – On some systems with eight Combo GbE/8Gb FC Express Module HBA cards and four
Sun Dual 10GbE 12 SFP+ PCIe 2.0 cards, Pc-Check incorrectly reports network card test
failures. If this occurs, turn off SR-IOV in BIOS by setting Advanced > I/O Virtualization >
SR-IOV >Disabled. Be sure to re-enable SR-IOV when you are done.
3 Click the Remote Control tab and then the Diagnostics tab.
The Diagnostics screen appears.
4 From the Run Diagnostics on Boot drop-down list, select the level of Pc-Check diagnostics to be
run.
Note – If you select Enabled or Extended, there is no need to perform step 6, step 8, or step 9. No
Pc-Check menus will be available. Instead, to view the results of the Pc-Check tests, see
“Viewing the Pc-Check Results” on page 64.
56 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
Pc-Check Diagnostics Overview
a. Click the Remote Control tab, and then click the Remote Power Control tab.
The Server Power Control window appears.
c. Click Save.
The host begins its startup sequence.
57
Pc-Check Main Menu
Option Description
System Overview Menu Includes basic information about your system, motherboard, BIOS,
processor, memory cache, drives, video, modem, network, buses, and ports.
58 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
System Information Menu
Option Description
Component Audit Menu Enables you to create an XML or .txt document describing your system.
System Management Info Provides information about the BIOS type, system, motherboard, enclosure,
processors, memory modules, cache, slots, system event log, memory array,
memory devices, memory device mapped addresses, and system boot.
PCI Bus Info Includes details about specific devices from pci-config space within the
system, similar to the System Management Information section.
APM Info Enables you to test and configure the Advanced Power Management (APM)
capabilities of the system. You can choose to change the power state, view the
power status, indicate CPU usage, get a power management event, or change
the interface mode.
I/O Port Browser Shows the I/O port assignment for the hardware devices on the system.
Memory Browser Enables you to view the mapped memory for the entire system.
Sector Browser Reads sector information from the hard disks sector by sector.
Start-Up Options Enables you to set up startup options for diagnostics testing.
Note – The Text File Editor command in the System Information Menu Options is of special
importance. You use it to view the results of Pc-Check tests. This is described in “How to View
Pc-Check Files With the Text File Editor” on page 64.
59
Advanced Diagnostics
Advanced Diagnostics
Advanced Diagnostics are used to test an individual device on the system. Most of the selections
on this menu display information about the corresponding devices, and then offer a menu of
testing options. For example, to test CPU 0, you can select Advanced Diagnostics Tests, and
then select Processor, and then select CPU0.
Note – If you do not know which device to test, see “Burn-In Testing” on page 61.
The following table gives the name and a brief description of many of the selections in the
Advanced Diagnostics Tests menu.
Note – Some of the tests in the table might not be applicable for your server.
Option Description
Memory Displays information about the memory, and includes tests for the
different types of system memory.
Hard Disks Displays information about the hard disk, and includes a Hard Disk
Tests menu.
Serial Ports Displays information about the serial ports and includes a Serial Port
Tests menu.
ATA Includes an ATA Test menu. Select the serial ATA driver to test.
USB Displays information about the USB devices on the system and
includes a USB Tests menu.
60 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
Standard Scripts
Option Description
SCSI Displays information about SCSI devices and includes a SCSI Test
menu.
System Stress Test Exercises and checks the CPU, memory, and hard drive.
Keyboard Includes a Keyboard Test menu with options for performing different
tests on the keyboard.
Mouse Displays information about the mouse and includes a menu to test the
mouse on the system.
Video Displays information about the video card. Initially, the monitor might
flicker, but then the system brings up a Video Test Options menu that
enables you to perform various video tests.
Burn-In Testing
Burn-in testing enables you to run test scripts and to create new scripts.
The main menu provides two burn-in selections, Immediate Burn-In Testing and Deferred
Burn-In Testing.
Standard Scripts
Oracle provides three ready-made scripts designed to test the general health of the devices on
your system. These scripts include:
■ quick.tst
This script performs a series of tests that require you to interact with the test software. When
they require a user interaction, they stop and do not time out. These tests are faster than the
full.tst, but they are less thorough. For example, they do not run all the tests associated with a
DIMM.
■ noinput.tst
61
Standard Scripts
This script performs a non detailed test of most hardware components, excluding those
components that require user input (keyboard, mouse, sound, and video). This test does not
require user input. It is normally the first test performed for hardware-related problems.
■ full.tst
This script performs a detailed and comprehensive test on all hardware components,
including those that require user input. It includes external port tests and requires loopback
connectors on COM ports, parallel ports, and USB ports. You must interact with the test
utility to progress through these interactive tests.
3 Type the name of the script you want to run, for example:quick.tst, noinput.tst, or
full.tst.
4 To change any of the options, at the bottom of the screen, click Change Options.
This opens the Burn-In Options menu, which enables you to modify the options listed in the
following table for the currently loaded test script.
62 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
Standard Scripts
Journal Options Failed Tests All Tests, Absent Devices, Failed Tests, All Tests,
and Test Summary Absent Devices, and Test
Summary
Pause on Fail N N Y or N
POST Card N N Y or N
Beep Codes N N Y or N
■ Change Options
Opens the Burn-in Options menu, which enables you to modify the various options listed in
the table in“How to Perform Immediate Burn-In Testing” on page 62 for the currently
loaded test script.
■ Select Tests
Opens a listing of all the possible types of tests available for you to run for the currently
loaded test script.
3 When you are done, choose Save Burn-in Script and type the name for the new script.
Enter d:\testname.tst where testname is the name of the script that you have created.
63
Viewing the Pc-Check Results
4 To run the newly created script, go to Immediate Burn-in Testing and run the script.
See “How to Perform Immediate Burn-In Testing” on page 62.
Other files are named PCCHECK.xxx, for example, PCCHECK.JNL or PCCHECK.HII. The .HII file is
especially important because it shows the entire host configuration at the time of failure.
64 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
Viewing the Pc-Check Results
1 On the Pc-Check main menu, select System Information Menu and press Enter.
The System Information Menu appears:
3 Type in the file name (for example, PCCHECK.JNL) and press Enter.
The editor opens with the file displayed, as shown here:
65
Viewing the Pc-Check Results
This section shows the following tests conducted against the processor: Core Processor
Tests, AMD 64-Bit Core Tests, Math Co-Processor Tests – Pentium Class FDIV and
Pentium Class FIST, MMX Operation, 3DNow! Operation, SSE Instruction Set, SSE2
Instruction Set, and MP Symmetry.
■ Motherboard
This section shows the following tests conducted against the motherboard: DMA Controller
Tests, System Timer Tests, Interrupt Test, Keyboard Controller Tests, PCI Bus Tests, and
CMOS RAM/Clock Tests.
■ Memory, Cache Memory, and Video Memory
This section shows the following tests conducted against the various types of memory:
Inversion Test Tree, Progressive Inversion Test, Chaotic Addressing Test, and Block
Rotation Test.
■ Input Device
This section shows the following tests conducted against the input device: Verify Device,
Keyboard Repeat, and Keyboard LEDs.
■ Mouse
This section shows the following tests conducted against the mouse: Buttons, Ballistics, Text
Mode Positioning, Text Mode Area Redefine, Graphics Mode Positions, Graphics Area
Redefine, and Graphics Cursor Redefine.
■ Video
This section shows the following tests conducted against the video: Color Purity Test, True
Color Test, Alignment Test, LCD Test, and Test Cord Test.
■ Multimedia
This section shows the following tests conducted against the multimedia components:
Internal Speaker Test, FM Synthesizer Test, PCM Sample Test, CD/DVD Drive Read Test,
CD/DVD Transfer (KB/Sec), CD/DVD Transfer Rating, CD/DVD Drive Seek Test,
CD/DVD Seek Time (ms), CD/DVD Test Disk Read, and CD/DVD Tray Test.
■ ATAPI Devices
This section shows the following tests conducted against ATAPI devices: Linear Read Test,
Non-Destructive Write, and Random Read/Write Test.
■ Hard Disk
This section shows the following tests conducted against the hard disk: Read Test, Read
Verify Test, Non-Destructive Write Test, Destructive Write Test, Mechanics Stress Test,
and Internal Cache Test.
■ USB
This section shows the following tests conducted against the USB: Controller Tests and
Functional Tests.
■ Hardware ID
66 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
Viewing the Pc-Check Results
The compare test is used to determine the machine ID for the system. This test is not
available for this server.
2 Choose the Print Results Report option from the Main Menu to print diagnostic test results.
67
68
U-Boot Diagnostic Start-Up Tests
This section describes how to configure the U-Boot diagnostics test mode and how to read the
results.
The U-Boot diagnostic tests run automatically when the server is started or rebooted. They test
the hardware to ensure that enough functionality is present to allow the SP to boot.
69
Running the U-Boot Diagnostic Tests and Viewing the Results
Memory Data Bus Test X X X Checks for opens/shorts on SP memory data bus.
Real Time Clock Test X X Checks functionality of the real-time clock on the
SP.
USB 1.1 BIST X X Runs internal USB 1.1 built-in self-test (BIST).
BIOS Flash ID Test X X Verifies ability to read from the BIOS flash.
Serial Presence Detect X Verifies DIMM SPD access along with checksum
(SPD) Access Test and prints SPD information.
70 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
U-Boot Diagnostic Test Output
To run the tests, see “How to Run the U-Boot Diagnostic Tests” on page 71.
4 Read the output, as described in “U-Boot Diagnostic Test Output”on page 71.
If any test fails, the test stops at that test, and the SP does not boot. Contact Oracle support.
For instructions to run the U-Boot diagnostics test, see “Running the U-Boot Diagnostic Tests
and Viewing the Results” on page 70.
U-Boot 1.1.4
Custom AST2100 U-Boot 2.0 (Jan 26 2009 - 10:29:26) r41480
DRAM: 119 MB
71
U-Boot Diagnostic Test Output
Flash bank 0 at 10000000 has 0x2000000 bytes in 256 sectors (chipSize 1--25,
size_ratio 1).
Flash: 32 MB
readonly: ethaddr=00:14:4F:CA:B5:10
readonly: eth1addr=00:14:4F:CA:B5:11
VUART1 already enabled at port 0x03f8, SerIRQ[4] rise
Protecting U-Boot flash sectors; monitor_base=100a0000.
Negating BIOS_TOP_BLOCK_LOCK signal.
H/W: Sun Fire X4800 M2 Service Processor; SOC: AST2100 Rev. 02 (’A3’)
PWC_SP_Broken_OD = 0; ARM restart caused by: watch-dog ExtRst# pin
The host is OFF(S5) (hostWantsPwr=0, powerGood=0,
allowPwrOn=0|0, outOfReset=0, fatalError=0).
Reset straps=0x88819180, def. H-PLL=264 MHz, CPU/AHB=2:1, boot CS0# normal speed
PCI w/VGA noVBIOS; DRAM clock is M-PLL: 264 MHz (DDR2-528)
DRAM: 128MB data - 8MB VGA, 32-bit noECC, 2 BA 10 CA, CL=4 BL=4 ap=1, 61440 us refr
Board Revision - cc
Net: faradaynic#0, faradaynic#1
Enter Diagnostics Mode [’q’uick/’n’ormal(default)/e’x’tended(manufacturing mode)].....0
Diagnostics Mode - QUICK
DIAGS Memory Data Bus Test ... PASSED
DIAGS Memory Address Bus Test ... PASSED
DIAGS PHY #0 R/W Test ... PASSED
DIAGS PHY #0 Link Status ... PASSED
DIAGS Testing PowerCPLD version ... PASSED
Booting linux in 3 seconds...
U-Boot 1.1.4
Custom AST2100 U-Boot 2.0 (Jan 26 2009 - 10:29:26) r41480
DRAM: 119 MB
Flash bank 0 at 10000000 has 0x2000000 bytes in 256 sectors
(chipSize 1--25, size_ratio 1).
Flash: 32 MB
readonly: ethaddr=00:14:4F:CA:B5:10
readonly: eth1addr=00:14:4F:CA:B5:11
VUART1 already enabled at port 0x03f8, SerIRQ[4] rise
Protecting U-Boot flash sectors; monitor_base=100a0000.
Negating BIOS_TOP_BLOCK_LOCK signal.
H/W: Sun Fire X4800 M2 Service Processor; SOC: AST2100 Rev. 02 (’A3’)
72 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
U-Boot Diagnostic Test Output
U-Boot 1.1.4
Custom AST2100 U-Boot 2.0 (Jan 26 2009 - 10:29:26) r41480
DRAM: 119 MB
Flash bank 0 at 10000000 has 0x2000000 bytes in 256 sectors(chipSize 1-25,
size_ratio 1).
Flash: 32 MB
readonly: ethaddr=00:14:4F:CA:B5:10
readonly: eth1addr=00:14:4F:CA:B5:11
VUART1 already enabled at port 0x03f8, SerIRQ[4] rise
Protecting U-Boot flash sectors; monitor_base=100a0000.
Negating BIOS_TOP_BLOCK_LOCK signal.
H/W: Sun Fire X4800 M2 Service Processor; SOC: AST2100 Rev. 02 (’A3’)
PWC_SP_Broken_OD = 0; ARM restart caused by: watch-dog ExtRst# pin
The host is OFF(S5) (hostWantsPwr=0, powerGood=0,
allowPwrOn=0|0, outOfReset=0, fatalError=0).
Reset straps=0x88819180, def. H-PLL=264 MHz, CPU/AHB=2:1, boot CS0#
normal speed
PCI w/VGA noVBIOS; DRAM clock is M-PLL: 264 MHz (DDR2-528)
DRAM: 128MB data - 8MB VGA, 32-bit noECC, 2 BA 10 CA, CL=4 BL=4 ap=1,
61440 us refr
Board Revision - cc
Net: faradaynic#0, faradaynic#1
Enter Diagnostics Mode
[’q’uick/’n’ormal(default)/e’x’tended(manufacturing mode)] 0
73
U-Boot Diagnostic Test Output
74 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
U-Boot Diagnostic Test Output
Fan Module 0
Bus Device Address Results
============================================
1 3 FM 0 FRUID (U0203) 0xAC PASSED
1 3 FM 0 PCA9555 (U0201) 0x42 PASSED
1 3 FM 0 ADT7462 (U0202) 0xB8 PASSED
16 Disk Backplane
Bus Device Address Results
============================================
1 4 BP MAX7313 (U1801) 0x44 PASSED
1 4 BP FRUID (U2102) 0xAC PASSED
Paddle Card
Bus Device Address Results
============================================
1 4 EXP FRUID (U0401) 0xAE PASSED
DIAGS PHY #0 R/W Test ... PASSED
DIAGS PHY #0 Link Status ... PASSED
DIAGS ETHERNET PHY #0, Internal Loopback Test ... PASSED
DIAGSTesting RTC ... PASSED
DIAGS USB 1.1 Register Test ... PASSED
DIAGS USB2.0 Register Test ... PASSED
DIAGS USB 1.1 Test ... PASSED
DIAGSAccess to BIOS Flash ... PASSED
CPU0 D0 ... Not Present
CPU0 D1 ... Not Present
CPU0 D2 ... Present
DIAGS>Verifying DIMM SPD Checksum on CPU0 D2 ... PASSED
SDRAM DEVICE DDR3 SDRAM
MODULE TYPE RDIMM
SDRAM SIZE 2 GB
NUMBER OF ROWS & COLUMNS 14 Row x 11 Column
CYCLE TIME DDR3 533Mhz clock(1066data rate)
MANUFACTURER_JEDEC_ID_CODE Micron
MANUFACTURED DATE Week 18 of ’08
MODULE SERIAL NUMBER EA09445A
MODULE_PART_NUMBER 18JSF25672PY-1G1D
CPU0 D3 ... Not Present
CPU0 D4 ... Not Present
CPU0 D5 ... Not Present
CPU0 D6 ... Not Present
CPU0 D7 ... Not Present
CPU0 D8 ... Not Present
CPU1 D0 ... Not Present
CPU1 D1 ... Not Present
PU1 D2 ... Present
DIAGSVerifying DIMM SPD Checksum on CPU1 D2 ... PASSED
75
Sample SP Environmental Variables Showing U-Boot Test Status
Note – The SP does not boot if the U-Boot test fails, so you will not be able to see the
environmental variables until it can be made to pass.
preboot- uboot
WARNING: Will reboot after 300 seconds of idle time.
=- showenv
bootcmd=bootpkg
bootdelay=10
loads_echo=1
autoload=no
number_of_loops=1
netretry=no
update_flash=protect off all; erase 100a0000 ${flash_top};
tftp 100a0000 ${bootfile}; setenv preserve_conf no; saveenv
update_uboot=protect off all; erase 100a0000 100fffff; tftp 100a0000 ${ubootfile}
erase_perm=protect off all; cp.b 10000000 42000000 20000; erase 10000000 1001ffff;
cp.b 42000000 10000000 18000
bootfile=nightly-virgo-rom.flash
netmask=255.255.255.0
ipaddr=10.8.185.77
serverip=129.148.40.42
gatewayip=10.8.185.254
76 Sun Server X2-8 (formerly Sun Fire X4800 M2) Diagnostics Guide • July 2012
Sample SP Environmental Variables Showing U-Boot Test Status
ubootfile=/tftpboot/sm158724/virgo-u-boot.bin
flash_top=11ffffff
ethact=faradaynic#0
diags_result=Diags .. PASSED
preserve_users=no
preserve_conf=yes
set_factory_defaults=no
serial_is_host=0
upgrade_bios=yes
baudrate=9600
ethaddr=00:14:4F:CA:16:0A
eth1addr=00:14:4F:CA:16:0B
stdin=serial
stdout=serial
stderr=serial
i2c_bus=2
77