Damped oscillatory wave simulator DOS 300

As per
CDN 405T8A1
> IEC 61000-4-18
> IEC 255-22-1
> GB/T 17626.12
S10 C15 > GB/T 14598.13
> ANSI C37.90

>

Description

DOS 300 damped oscillatory simulator can produce repeatable transient on HV or medium voltage power cord, control line and
signal line. It can meet the requirements of slow damped oscillatory test as per IEC 61000-4-18.

Features Industries

> 5.7 inch color touch screen front panel operation > Communication > IT
> compact simulator up to 3.3kV
> Telecom > Military
> internal single phase or three-phase CDN, current up to
> Medical > Avionics
16A

> external three-phase CDN, current up to 32A > Broadcast > New energy

> LAN Ethernet port for remote control > Railway


> Meet the requirements of immunity test equipments for

enterprise, institution and testing organization.

www.3ctest.cn 3ctest> 1/4


V1.0
For future modern equipments

General data
General data
Test voltage 0.2kV -3.3kV , ±10% (source port) Display
5.7 inch TFT touch screen
Polarity +/- Power supply AC 110V/220V , ±10% ,
Source
200ohm±10% 50/60Hz( default AC 220V 50Hz for
impedance
China mainland)
Rise time 75ns ±20% Fuse
6A
1-500HZ, Max power
Repeat 100W
Adjustable consumption
frequency
100HZ(1-50HZ);1MHZ(1-500HZ) Working indicator LED, LCD front panel display
Size 19 inch/6U/4U
Oscillatory
100kHz,1MHz±10%
frequency Weight approx.28Kg

Attenuated to 50% during third and sixth Temperature 15–35℃


Attenuation
cycle Humidity 45%–75%

Pulse duration 1~99s Air pressure 86kPa–106kPa

Pulse interval 1~99s Basic equipments

Number of Simulator, test cable, ground wire, fuse, factory test report,
1–999
repetition warranty report and user manual

Trigger mode Automatic, manual and external

synchronization 0°- 360°, 1°step or random

Internal three-phase AC CDN


CDN
AC 380V 16A Max:AC 450V

www.3ctest.cn 3ctest> 2/4


V1.0
For future modern equipments

Optional accessories

CDN

Unshielded asymmetric CDN


CDN 412AF2/412AF4(90V gas discharging tube coupling; test voltage: 4KV;AE/EUT port-RJ45; max. Withstand current: 1A;

decoupling residual value: 90V)

Unshielded asymmetric CDN


CDN 418AF4/418AF8(90V gas discharging tube coupling;test voltage: 4KV;AE/EUT port-RJ45; max. Withstand current: 1A;

decoupling residual value: 90V)

Unshielded symmetric CDN


CDN 418T4/418T8(90V gas discharging tube coupling;test voltage: 6KV;AE/EUT port -RJ45; max. Withstand current:

1A;decoupling residual value: 90V)

2. PC control software EMSLab

With PC installed WIN XP and WIN7, it can be easily operated to make the measurement, based on the customized test

program. It can identify any device with automatic configuration. It can easily generate test reports.