1 Service 2 Entry

Appl. Supervisor
Master
Standard
Mode
WTX110
< 3 seconds
WTX110 V#.#.#
< 3 seconds Navigation Pilot
Password General Products Weight Storage Logbook Software ID MAC-/IP-Address

Enter service
password
Date: Entry Target weight Search Date 3_ ... ID: ... M:
Time: Entry ... Id-No. 2_ ... IP:
… Weight not found 1_...
Brightness
Filler configuration; only info
Password parameter
only available note: only if
in filler application ALI available

Service Mode Application Mastermode

Interface General Calibration Config. Test Reset Network Backup General Setup Limit switches Digital IO Print Formats Factory defaults Mode: Info Mode: Adapt
(zero offset) (several
note: if „W1“ jumper filter settings)
is in position 1
Language only access, Scale Digital IO Reset Service IP Backup or Application LS1 – LS4 Source Input 1 – 4 Ticket Weight Load application
Com0 (Eth) Com1 (SIM1) Com6 (DWB) no changes possible
Keyboard Serial IO Mode Parameters? Mask Restore LS1 – LS4 Mode Output 1 – 4 Total Weight
Reset from USB
Time Zone (1) Calibrate Scale 1 Gate Ticket Count
Approved Wgt note: after
Time Zone (2) DNS change restart Total Count
Port Baud Baud only available in
Date (format only) NTP note: ETH required!
Protocol Databits Databits standard application
Time (format only) FTP pwd or USB option Language
Parity Parity note: only if
Mastermode error protocoll, required
Country Code ALI available PanelX access
Ctrl. Ctrl. note: alternative only info
Decimal char. access Access number
Protcl. Protcl.
Approval signs Set PanelX password
Tare mode Update SSL cert
Cont. out. Start auto ping
Light off (Min.) Terminal No.
Power off (Min.) Config. Config.
Config. Scale
Power Supply Digital IO Analog out
Serial No.

ADM PIM Non


HBM Modbus TCP DAU15
None SIO ...
None Aout 1: Mode
exception: back to „Select Group 1 – 9“ with
Aout 1: Output
not with the F1 button
Aout 1: Calibration

1 Scale 2 Calibration 3 Linearization 4 Zero Adjust 5 Adaption 6 High 7 Reset 8 Calculation 9 W&M Info
Select Group 1 – 9 Parameters Resolution Span

note: adapted parameters


must be saved to be valid!
Geo Value New Fixpoint 1? Motion Window Weight Reset Parameters? Calibrate Zero? W&M Setup ok
Calibrate Zero? Unload Scale Motion Counter Zero (mV/V)
Calibrate Load? Filter Size LC-Cap. (kg)
note: only
Auto Zero Range No. of LCs
calibration
... mV/V of LC1
Single Range Dual Range Triple Range Incline Switch
PowerUp Zero
Map symbology With Taring?
High Cap. High Cap. Underload Quick Start Guide for Calibration Setup
Two different possible entries High Int. High Int. Update Rate

A4855-1.0 7-2002.4855 HBM: public


Low Cap. Mid Cap.
1. Connect Sensor
Entry field F1 button level Low Int. Mid Int. 2.  go to “Calibration”\“1 Scale Parameters”
Unit Low Cap. and enter load cell parameters like Capacity, Interval, Unit
Subsequent field F1 button level Low Int. 3. Perform Calibration
Unit - with Calibration Weight go to “2 Calibration”
Related fields on F1 button level - without Calibration Weight go to “8 Calculation Span”
4. Enter further parameters like Dual Range, Linearization, etc.
Enter password / Unload Scale One Interval Two Intervals Three Intervals Two Intervals T+ Three Intervals T+
5. Save Calibration Parameters
Mastermode
Capacity High Cap. High Cap. High Cap. High Cap.
F1
Click F1 button Interval High Int. High Int. High Int. High Int.
Unit Low Cap. Mid Cap. Low Cap. Mid Cap.
F2 F3 F4 F5
Low Int. Mid Int. Low Int. Mid Int.
Click respective grey button
Unit Low Cap. Unit Low Cap.
Low Int. Low Int.
Notes